DATA SHEET Panorama Rudder Indicator, TRI-2

Similar documents
DATA SHEET. Synchronisers, FAS-113DG ANSI code 25

LAUREL ELECTRONICS, INC.

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

02/11/2015

Contactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Linear encoders without bearings incremental System for linear motion feedback

AMU2-2MHD+ Audio monitoring Unit

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Process transmitter RMA422

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

Contactless encoder RI360P0-QR24M0-INCRX2-H1181

LOW-COST, 3 1/2 DIGIT DC VOLTMETERS MODEL 201A & 201AN OPTION 201AN-AC / 301AN

Contactless Encoder SSI RI360P0-QR24M0-HESG25X3-H1181

Material: Weight: IP Rating: Cable: Connector:

TFRN Industrial RTD temperature sensor. CombiTemp TM

CEDES. Functional description CEDES 7-Segment Double Digit Indicator (CAN) Functional description 7-Segment Double Digit Indicator (CAN)

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

Proportional output thumbwheels - sprung to centre

Contactless Encoder Analog RI360P0-QR24M0-ELIU5X2-H1151

Contactless encoder Ri360P0-QR24M0-HESG25X3-H1181

Single Point Flow Monitor SW118 SW119

Linear flow control with actuator IFC

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

Simple all-in-one design style with front stereo speakers and natural ventilation system

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

Panel-mounting thermostats, type series EM

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

TECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT

Absolute Encoders Multiturn

Artistic Licence. moody & moody cv. User Guide. Download the user guide by scanning the following QR code: moody & moody cv User Guide.

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Manual. Analog (U/I) Sendix M3661 / M3681. Sendix M3661R. Sendix M5861. Absolute multiturn encoder. Order code: 8.M36X1.XXXX.XX12

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

SCALE & WEIGHT DISPLAYS

Display Information Type Backlit blue on white STN Type

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Displays Open Frame Monitor Model Number: AND-TFT-150Bxx

Manual. Simrad IS80 Heading Repeater HR80. English

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

Manual. Simrad IS80 Wind Instrument WI80. English

Micro-DCI 53ML5100 Manual Loader

Touch Panel Display Module

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Process Transmitter RMA 422

263 Series LED Bargraph Indicator and Controllers

Photoelectrics Through-beam Type PA18C.T..., DC

TFRH Hygienic RTD temperature sensor. CombiTemp TM

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

Safety Light Curtains GuardShield

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

Absolute Rotary Encoder E6CP

Series SM ø12 mm. Inductive Position Transducer. ranges mm. linearity 0,2/0,3% ø12 mm, clamp-ø8 mm h6. out: AC, V, V, 4...

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

TFRN Industrial RTD temperature sensor. CombiTemp TM

Label Applicator HERMA 400

Contactless Encoder IO-Link Ri360P0-QR24M0-IOLX2-H1141

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Linear flow controls VFC Linear flow controls with actuator IFC

BL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC

1440/2880 HP RGB+WW+CW

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5

AMU1-BHD+ Audio monitoring Unit

5700 series Displays PERFORMANCE MADE SMARTER TEMPERATURE I.S. INTERFACES COMMUNICATION INTERFACES MULTIFUNCTIONAL ISOLATION DISPLAY

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

Intelligent Security and Fire Ltd

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

Actuators IC 20, IC 40

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

TECHNICAL DATASHEET Absolute Encoder AC 58 - SSI-P

Standard RS232 RS ma

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

Absolute encoders multiturn

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

SERIES 400 SERIES 620

FLAT DISPLAY TECHNOLOGY

AVMU2-BHD+/3G Audio monitoring Unit

Magnetic and Hydraulic-Magnetic Circuit Breaker

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

E3/DS3 Fibre Extender

SY-HDBT-100 Extender Set

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

48x24. Options ORDER NUMBER OF TYPE PFL B

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

SDI-MP1010-GM-60P-M-RA 3G/HD-SDI Output Video Transceiver. SDI-MP1010-GM-60P-M-RA Features. Block Diagram SDI-MP1010-GM-60P-M-RA.

Quick Operation Guide of LTN7700/7600 Series NVR

Bimetal Temperature Switch

Transcription:

DATA SHEET Panorama Rudder Indicator, TRI-2 Class 1 accuracy on CAN version Readable from up to 5 metres Single and dual CAN or analogue interface LED illumination DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com www.deif.com Document no.: 4921250066D SW version: N/A

1. General information 1.1. Technology and application...3 1.1.1. Technology...3 1.1.2. Application... 3 1.2. Scale colour, illumination and dimming... 4 1.2.1. Scale colour...4 1.2.2. Illumination...4 1.2.3. Dimmer... 4 1.2.4. CAN dimming...4 1.3. Mounting, cabling and labelling...4 1.3.1. Mounting...4 1.3.2. Cable entry... 4 2. Technical information 2.1. Terminals and technical specifications... 5 2.1.1. Terminals, CAN version... 5 2.1.2. Terminals, analogue version...6 2.1.3. Technical specifications... 7 3. Ordering information 3.1. Order specifications and disclaimer... 9 3.1.1. Order specifications...9 3.1.2. Order steps of TRI-2 CAN... 9 3.1.3. Disclaimer...10 DEIF A/S Page 2 of 10

General information 1. General information 1.1 Technology and application 1.1.1 Technology DEIF s TRI-2 panorama rudder angle indicator is based on a well-known moving coil system which secures a fast response. In the CAN version, a micro controller ensures class 1 accuracy and even opens up for an expanded scale centre to achieve better readout accuracy around rudder zero. The below example illustrates a scale with an expanded mid section. 40.30.20.10.5.0.5.10.20.30.40 Versions and dimensions Two basic versions are available: TRI-2 Analogue (standard voltage and current inputs, 3-wire rudder interface) TRI-2 CAN (single and dual CAN) The type label is located at the base of the indicator. Therefore it is recommended to note the order number before mounting the indicator. If service is needed later on, the order number will be required to identify the instrument. 1.1.2 Application The panorama rudder angle indicator type TRI-2 is applied for the indication of the rudder position on the bridge. The TRI-2 is CE-marked for marine, residential, commercial and light industry plus industrial environment. It is housed in a matt black, splash-proof case for deck-head suspension. Equipped with three large scales, the TRI-2 ensures quick and easy reading of the rudder position from any angle up to 250 and from a distance of up to 5 metres. DEIF A/S Page 3 of 10

General information 1.2 Scale colour, illumination and dimming 1.2.1 Scale colour The indicator is available with two scale types: 1. White scales with black figures, division lines and black pointer. 2. Black scales where the figures, division lines and the pointer are yellow. On both white and black scales, starboard is marked with a green section (to the right), port with a red section (to the left) underneath the division lines. Reversed scales and scales with centre expansion are available on request. 1.2.2 Illumination The TRI-2 is equipped with long-life LEDs, ensuring easy and clear reading of the scales in the dim light on the bridge. The standard colour is yellow. On the CAN version it can be set up to red or advanced dimmer function where the light changes to red colour at low settings for better night vision. Notice that if red illumination is used, the green colour looks black. White scales are translucent, implying that the division lines and the figures are clearly visible, and that the pointer is seen clearly as a shadow. On black scales, the figures, the division lines and a broad, yellow section underneath these are translucent and illuminated. The pointer is clearly visible as a shadow against this yellow section. 1.2.3 Dimmer The light intensity can be changed by means of a built-in dimmer, accessible on the rear plate of the indicator. If remote dimming is preferred, the built-in dimmer potentiometer may be removed from the indicator (after dismantling of the rear plate) and mounted e.g. in a control panel. The maximum cable length is 100 m. A plug for sealing of the hole in the rear plate is included in the delivery. 1.2.4 CAN dimming Dimming may also be controlled from the CANbus, in this case the built-in analogue dimmer is inhibited (custom-specific CAN option). 1.3 Mounting, cabling and labelling 1.3.1 Mounting The TRI-2 is intended for mounting on the deck head by means of six 5 mm screws. It is important that the deck is level so the instrument is not deformed when the screws are fastened. Note that if extra holes are drilled, the warranty will no longer be valid. 1.3.2 Cable entry Cable entry via PG 13.5 cable glands. DEIF A/S Page 4 of 10

Technical information 2. Technical information 2.1 Terminals and technical specifications 2.1.1 Terminals, CAN version Pin no. Function CANopen Note 1 Supply voltage +12 V-24V DC Consumption 12 V 300 ma/24 V 150 ma 2 " 0V DC " 3 CAN connection CAN 2 H input CAN 2 line 4 " CAN 2 L input " 5 " CAN 2 GND " 6 " NC " 7 " CAN 1 H input CAN 1 line 8 " CAN 1 L input " 9 " CAN 1 GND " 10 Illumination Dimmer wiper Dimmer control via 1k ohm 2 W potentiometer 11 " Dimmer ref. " Label The connection terminals are located under the rear plate. A fumble wheel (integrated push-button/rotating switch) is located between the two sets of connectors. The wheel is used for the entire setup together with the two LEDs marked 1 and 2 located on each side of the switch. DEIF A/S Page 5 of 10

Technical information The following can be set using the fumble wheel: 1. Zero adjustment (centre point on the scale). Max. adjustment (end point on the scale). 2. Reverse the pointer direction CW or CCW. Selection of CAN ID. 3. Dimmer select group 1..8 and the CAN protocol to be used. Backlight colour, yellow, red or auto shift. For further details regarding the set-up, see the installation manual on www.deif.com. 2.1.2 Terminals, analogue version The connection terminals are located under the rear plate. For general current/voltage: For 3-wire rudder interface: Measuring ranges (DC input only): Voltage Lowest: Highest: Load: 0...4 V 0...100 V 0.7 kω/v -2...0...2 V -100...0...100 V 1.4 kω/v Current Lowest: Highest: Load: 0...1 ma 0...100 ma 3.0 V -1...0...1 ma -100...0...100 ma 1.5 V 4...12...20 ma 4.0 V DEIF A/S Page 6 of 10

Technical information 2.1.3 Technical specifications TRI-2 has been designed according to the below standards Standards/remarks Power supply 12 V or 24V DC (9.0 to 31.2V DC) Only CAN version Power consumption 24V AC/DC -25/+30% for illumination < 4 W with full illumination Analogue version Interface Single CAN and dual CAN CAN version Galvanic separation Standard analogue interface or 3-wire rudder interface 600 V, 50 Hz, 1 minute between: Power supply, CAN 1, CAN 2 Analogue version, see measuring range table Safety Cat. III, poll. dg. 2, 550V AC rms, 50 Hz, 1 minute EN 61010-1 Accuracy (CAN) Class 1 in the range -10 15 30 55 C IEC/EN 60051 Accuracy (analogue) Class 1.5 in the range -10 15 30 55 C IEC/EN 60051 Pointer Increasing positive input moves pointer CW CW: Left to right Extended accuracy Improved accuracy around zero can be achieved by expanding the centre of the scale (partial linear scale) The feature is optional Temperature -10 to +55 C nominal, -25 to +70 C operating, -25 to +70 C storage Only CAN version EN 60051 Start-up time < 5 sec. from power on to valid pointer position Only CAN version Cable dimension 0.2 to 2.5 mm 2 Cable entries Mounting Compass safety distance Two PG13.5 cable outer diameter 6 to 12 mm 6 x ø5.5 mm holes 1 metre (40 inch) IEC/EN 60945 Protection IP54 IEC/EN 60529 Relative humidity 0 to 95% without condensation IEC/EN 60068-1/2 Pressure Vibration EMC Housing Weight 600 to 1100 hpa 3 to 13.2 Hz: 2 mm (peak-peak) 13.2 to 100 Hz: 0.7 g CE-marked for marine, light industrial and industrial environment Plastic housing: Polycarbonate +10% glass fibre Metal parts: Made out of corrosion-resistant materials 2080 g EN IEC 60945, EN/IEC60068-2-6 and DNV Class A IEC 60945, EN 61000-6-1/2/3/4 60255-22-1 UL94 V0 DEIF A/S Page 7 of 10

Technical information TRI-2 has been designed according to the below standards Dimensions, cardboard box 380 x 380 x 145 mm Standards/remarks Approvals Type-approved according to: MED Directive DEIF A/S Page 8 of 10

Ordering information 3. Ordering information 3.1 Order specifications and disclaimer 3.1.1 Order specifications Mandatory information Item no. Type (housing) Variant no. Protection Input type Input range 1) Scale design 2) Mandatory information Item no. Variant no. Type (housing) Protection 2951460020 TRI-2 01 IP54 Analogue, single Input type Input range 1) Scale design 2) 2951460020 TRI-2 02 IP54 CANopen All versions included 0...1 V 4155110751 4155110751 Notes: 1) Input range must be selected within the range stated in the table in paragraph 2.1.2. Input range 0...1 V is used as an example. 2) Scale design must be selected from DEIF's range of standard designs (document no. 4921290030), or a new custom design must be made. Design 4155110751 is used as an example. 3.1.2 Order steps of TRI-2 CAN To order a TRI-2 CAN, the following parameters must be defined: Source ID CAN transmitter bit resolution CAN zero angle Pointer direction Backlight Dimmer group Select source node ID The source ID is used to define from which transmitter the TRI-2 will listen for data. The source node ID (sid) value can be set from 1 to 127, default value is 1. The TRI-2 receives pointer data from TPDO 0x180 + "Source Node ID" + Offset. The offset can only be set at the menu in the TRI-2 during installation and can be set from 0 to 7. Offset default value is 0. Example: CAN encoder RTC 300 or RTC 600 with default settings from DEIF. DEIF A/S Page 9 of 10

Ordering information The CAN encoder transmits data on 0x181 as a 16 byte value with data in byte 0 and 1. The TRI-2 now receives data from the CAN encoder. Adjustment in the TRI-2 menu makes it possible to set the TRI-2 to receive data from another TPDO than 0x181 if needed. The range in this example will be from 0x181 to 0x188 (0x181+0x7). Order the TRI-2 with source node ID 1 to receive CAN data from TPDO 0x181, from for instance DEIF RTC 300 or DEIF RTC 600. Select resolution of encoder Define the resolution of the CAN encoder values to select from: 12-bit, 13-bit, 14-bit, 15-bit or 16-bit. CAN zero angle It is possible to define which CAN value should be used as 0. It is possible to select between Zero and Half range. 1. Zero: when the CAN value 0 is transmitted to the TRI-2, the pointer will be positioned at 0 deg. Use this if a DEIF RTC encoder is used in the application. 2. Half range: if a 12-bit encoder is used, the value of 2047 (0x7FF, half range) is required to position the TRI-2 pointer at zero. For a 16-bit encoder, the half range value is 32767 (0x7FFF) which will position the pointer at zero. Pointer direction Define direction CW or CCW. Default is CW. Scale number Select from predefined scales, see the document "Illuminated indicators, standard scale designs 4921290030 UK" on www.deif.com for further info. Backlight Select the desired colour of the LED to be used for backlight: "Auto", "Red" or "Yellow" (Yellow is default). 3.1.3 Disclaimer DEIF A/S reserves the right to change any of the contents of this document without prior notice. The English version of this document always contains the most recent and up-to-date information about the product. DEIF does not take responsibility for the accuracy of translations, and translations might not be updated at the same time as the English document. If there is a discrepancy, the English version prevails. DEIF A/S Page 10 of 10