Operating Manual B 300

Similar documents
Users Manual FWI HiDef Sync Stripper

Operating instructions Electronic preset counter Type series 717

Intelligent Pendulum Hardness Tester BEVS 1306 User Manual

The measurements are stored in non-volatile memory, which retains data even when the power down.

Revision 1.2d

INSTRUCTIONAL MANUAL FOR LCD ZOOM MICROSCOPE

Series 1100 ColorTS Servo Manual Registration System

STX Stairs lighting controller.

SDC-500 Digital Optical Chopper Operating Instructions

2013, 2014 Hewlett-Packard Development Company, L.P.

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Multi Channel Programmable Filter-Amplifier. User Manual I-II III V-U SAT. Stop Channel SAT Slope Start Channel SAT ON / OFF.

Manual placement system MPL3100. for BGA, CSP and Fine-Pitch components

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

CHRONOSCOPE M1. Instruction Manual. Witschi Electronic Ltd. Document Nr D35e Rel CH 3294 Büren a/aare Switzerland

Technical Description

F90 Series (Rate Indicators / Controllers) INSTRUCTION MANUAL

ASSEMBLY AND CALIBRATION

Flat-Bed Module Recorders

Quick Start Function Summary Instructions for ASHCROFT GC52 Differential Pressure Transmitter Version 6.03 Rev. B

Ocean Sensor Systems, Inc. Wave Staff, OSSI F, Water Level Sensor With 0-5V, RS232 & Alarm Outputs, 1 to 20 Meter Staff

USER MANUEL. SNIPE 2 Ref R13

Multifunction devices

GEOSATpro GS120. DiSEqC 1.2 Motorized H-H H Motor

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Burlington County College INSTRUCTION GUIDE. for the. Hewlett Packard. FUNCTION GENERATOR Model #33120A. and. Tektronix

High Performance (Gold Plus) Spliceable Tape Feeder Part Number: Part Number: Revision 3 Jun 2008 No.

1. Power supply 100, 110, 200, 220, 230 V AC (as designated), 50/60 Hz, single phase.

AFM1 Imaging Operation Procedure (Tapping Mode or Contact Mode)

SIMET AVIKO D INSTRUCTION MANUAL SORTING Solutions, Ltd.

10MHz Source/Inserter

P701 Installation Guide 70 LCD Display Rev 1.3

ImproX SupaGate 4-Channel Controller INSTALLATION MANUAL

K Service Source. Apple High-Res Monochrome Monitor

Marine LCD Display MV-1504/1704/1904/2104

ivw-fd122 Video Wall Controller MODEL: ivw-fd122 Video Wall Controller Supports 2 x 2 Video Wall Array User Manual Page i Rev. 1.

OWNER S MANUAL LCD MONITOR ENGLISH. Please read this manual carefully before operating your set and retain it for future reference.

Installation and Setting up Instructions for the 990 Signal Conditioning Instrument

Label Applicator HERMA 400

Single Axis Position Controller

OWNER S MANUAL MOTORIZED 7 WIDE TFT LCD COLOR MONITOR CNT-701

P401 Installation Guide 40 LCD Display Rev 1.3

Technical data. General specifications. Indicators/operating means

Application Note: Using the Turner Designs Model 10-AU Fluorometer to Perform Flow Measurements in Sanitary Sewers by Dye Dilution

LCD4215 Installation Guide 42 LCD Display Rev 1.1

American DJ. Show Designer. Software Revision 2.08

Introduction Display...1 Mounting...1 Firmware Version...2. ADL Operation... 3

PLL1920M LED LCD Monitor

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Boulder 1010 Preamplifier

Noise Detector ND-1 Operating Manual

Version 1.10 CRANE SONG LTD East 5th Street Superior, WI USA tel: fax:

miniature TEM sampler manual

FCC Compliance Statement

DCD-24 Word Clock Distributor

Manual. Analog (U/I) Sendix M3661 / M3681. Sendix M3661R. Sendix M5861. Absolute multiturn encoder. Order code: 8.M36X1.XXXX.XX12

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Lecture 14: Computer Peripherals

DTA INSTALLATION PROCESS & USER GUIDE FOR SPECTRUM BUSINESS CUSTOMERS

User Manual MODEL: KK1500-TR. Touch Display LCD Monitor. Installation Guide. 15 Resistive Touch LCD Monitor

Hour Meters / Timers, electronic

SonoruS Audio. ATR10 Analog Tape Reproducer. Operating Manual

DGC-1000A CLAMP-ON GROUND RESISTANCE TESTER

RMS 8424S Quick Start

EM1. Transmissive Optical Encoder Module Page 1 of 8. Description. Features

EM1. Transmissive Optical Encoder Module Page 1 of 9. Description. Features

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

Model: DT-X24H 23.8" Broadcast Studio LCD Monitor. User Manual. Ver:V1.0.0V00. Please read this User Manual throughout before using.

Intra-oral X-ray unit with high frequency DC generator. Product Data

TABLE OF CONTENTS. Instructions:

Industriefunkuhren. Technical Manual. OEM Sync-Module FE1000 (IRIG-B) ENGLISH

Digital Real Time Recording VCR

800 Displaying Series Flowmeter

Figure 1. MFP-3D software tray

1000TII TURNING CNC CONTROLLER

Re:connect M 203. RS232 Interface Revox. Dominating Entertainment. Revox of Switzerland. E 2.03

AE SERIES GPS MASTER CLOCK SYSTEMS

Hardware & software Specifications

Magnetic Rower. Manual Jetstream JMR-5000

Model: S-1071H 7" Broadcast On-camera 3GSDI&HDMI LCD Monitor. User Manual. Please read this User Manual throughout before using.

TV Synchronism Generation with PIC Microcontroller

DTL-4800P. Digital Real Time Recording VCR

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

LCD VALUE SERIES (32 inches)

ivw-fd133 Video Wall Controller MODEL: ivw-fd133 Video Wall Controller Supports 3 x 3 and 2 x 2 Video Wall Array User Manual Page i Rev. 1.

FREQUENCY COUNTERS TO 18 GHZ USING THE DATUM FREQUENCY STANDARD

Video Wall Installation Guide User Guide

DCL9AW. User Manual. English

Overview E248W-19203R. LED Panel. Features

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA

SBL /SBLG Series Wireless Clock

AC334A. VGA-Video Ultimate BLACK BOX Remote Control. Back Panel View. Side View MOUSE DC IN BLACK BOX ZOOM/FREEZE POWER

Jinyoung Contech Co., Ltd DAEWON B/D, JAMWON-DONG, SEOCHO-KU, SEOUL, KOREA

Multi channel programmable Filter-Amplifier

K Service Source. Apple High-Res Monochrome Monitor

2002 Martin Professional A/S, Denmark.

NETWORK COMPASS USER MANUAL CONTENTS

INSTRUCTION MANUAL. MODEL Downconverter

Chapter Medical Table of Contents

Evolution Digital HD Set-Top Box Important Safety Instructions

Transcription:

Greiner vibrograf A.G. Mittelstrasse 2 CH - 4900 Langenthal Switzerland Tel. ++41 62 923 44 33 Fax ++41 62 923 18 46 info@greinervibrograf.ch www.greinervibrograf.com B 300 MANUAL Operating Manual B 300

CONTENTS Contents --------------------------------------------------- Preface ----------------------------------------------------- The B300 presents itself ------------------------------ Control and Display ------------------------------------ Test of mechanical watches ------------------------- Test of quartz crystal watches (LCD) ----------- Test of quartz crystal watches (analog type) Alphanumeric print ------------------------------------- Insert paper roll ------------------------------------------ Change ink roll cassette ------------------------------ Technical data ------------------------------------------- Computer connection ( RS - 232 ) ----------------- Help ---------------------------------------------------------- page 1 page 2 page 3 pages 4-6 page 7 page 8 page 9 page 10 page 11 page 12 page 13 page 14 page 15 Operating Manual B 300 page 1

PREFACE You are the proud owner of a B 300. Congratulations, you made the right choice. You probably know that Greiner vibrograf has a long standing tradition in the manufacture of watch timing devices. A very important factor is the tremendous development, the electronic field went through. A multitude of new components, miniaturization, new technologies and automatisation demanded the continuous adaptation of the present testing machines. We believe the B 300 presents an electronic apparatus that not only contains the "State of the Art" in electronics but also a combination of principles which formerly could only be realized by several individual machines. The B 300 allows to test practically all existing watches! The measured parameters can be recorded visually, printed by the recording mechanism or displayed on a computer screen. The design consumes very little benchspace, has very low noise emission and is easy to read. Completely new realized demands on the accuracy of the time standard allow to measure the perfection of timing obtained with quartz crystal controlled watches. Just imagine that accuracy in the range of 10-8 are the values, figures that are a couple of magnitudes better than the earth rotation! Assuming that you selected the B 300, proves to us that we are on the right track with our development. The excellent quality of the apparatus will serve you the best! Let us briefly familiarize you with the many possibilities. This manual is thought of being a guide to navigate you through the use, maintanance and interpretation of the results.? Should you still have any questions, please call us directly or one of our service agencies. Greiner vibrograf AG Mittelstrasse 2 CH - 4900 LANGENTHAL TEL. ++41 62 923 44 33 Fax. ++ 41 62 923 18 46 Operating Manual B 300 page 2

THE B 300 PRESENTS ITSELF Front-view Pushbuttons to open cover Preselect field with impuls buttons Display field Volume adjusting knob for mechanical watches Selecting button for mechanical or quartz watches Paper guide and paper cutting Index disk Paper ribbon diagram and alphanumeric recording Connection for earphone Pressure roller for paper feed Back view Type label Cable throughput for paper rolling device Connection for quartz microphone (Pick-up) Connection for microphone for mechanical watches Fixing points for paper rolling device Computer interface RS 232 Main connection Fuse box Main switch Fuse insert for fuse box Operating Manual B 300 page 3

CONTROL AND DISPLAY DIAG Recording on paper ON / OFF The light is on for activated recording The paper advance starts automatically as soon as a watch signal is detected. The paper advance stops if no watch signal is detected (machine standby). CONT This button has 2 functions Short push ON / short push OFF : Continuous recording of the measured values and continuous paper advance Push and hold: Amplitude, Repère and Beat deviation are printed alphanumerically. AUTO Automatic beat selection The light is on for activated beat selection. The beat of the watch is selected, displayed and locked in. MAN Manual beat selection The light is on if manual beat selection is in service. The desired standard beat can be adjusted between 3600 and 36000. (Standard beat list see page 13 ) Note: We use the french word " Repère " to indicate the value in ms (milliseconds) a watch or clock is "not in beat", as it is known a watch or clock to limp. The french word seems to be traditionally the best term to describe this failure of adjustment. Operating Manual B 300 page 4

CONTROL AND DISPLAY FREQ SEL Measured beat If the button is pushed, the currently measured beat is registered to indicate the beat deviation from zero The recording locks now into this frequency and the recording is a straight line. Push again makes a reset and the new current beat is registered again. The light is on if a beat frequency is locked in. The indicated beat can be changed by pushing SEL and then adjusted to the desired value by pushing the beat button up or down. Short push, changes beat by beat. Push and hold, changes beat value fast. Takes over measured beat The indicated beat measured by AUTO, MAN, or FREQ. can be taken over by activating SEL and adjusted between 3590 and 36100 by pushing the beat button up or down. Short push, changes beat by beat. Push and hold, changes beat value fast. LIFT Selection of lift angle By the buttons up or down, the lift angle can be adjusted between 30 and 70 degrees. It is displayed in angular degrees ( ). Short push, changes degree by degree. Push and hold, changes degree value fast. RESOL Resolution of the printed recording By the buttons up or down,the resolution of scale factor can be changed between 0,5 and 50. IMPORTANT: 0,5 corresponds with resolution by factor 1 50 corresponds with resolution by factor 100 ( List see page 13 ) TIME BEAT Measuring time By the buttons up or down, the measuring time interval can be adjusted between 2 and 60 sec. The results of Amplitude and Repère are displayed after 2 seconds. The result of beat deviation is displayed the first time after the countdown of the selected measuring time interval and then again every 2 seconds. Beat selection By the buttons up or down, the beat frequency can be adjusted between 3590 and 36100 These buttons are only effective if MAN or SEL are active. Short push, changes beat by beat. Push and hold, changes beat value fast and continuously. The selected Beat is displayed as Beat / h Volume adjusting for mechanical watches The watch beat reception is visible on the green LED beside the button. Volume increase: clockwise rotation.this includes volume in the earphone. Standard setting on vertical line I / 0 Preselect line on display ON / OFF The preselect line (upper display line ) ON / OFF Operating Manual B 300 page 5

CONTROL AND DISPLAY Selection of microphone Lamp ON = Microphone (Pick- up) for Quartz crystal watch is active. Lamp OFF = Microphone for mechanical watch is active. SCALE Selection of indication in display field [ SEC/DAY ] Lamp ON = Display of electronically calculated beat deviation in the field. Lamp OFF = Display of value adjusted by the index scale in the field. DISPLAY Divided into 2 lines Upper line = Preselection values Lower line = indication of the measured values Amplitude, Repère, Beat deviation Upper line [ ] Degrees of lift angle 30-70 [ x ] Display of scale factor 0,5-50 [SEC] Measure time interval 2-60 sec. [ BEAT/h ] Display of selected beat 3590-36100 Lower line [ ] Display of amplitude (mechanical watches only) [ MS ] Display of repère (mechanical watches only) milliseconds [SEC/DAY] Display of beat deviation for mechanical and Quartz crystal watches Receptacle for ear phone Operating Manual B 300 page 6

TEST OF MECHANICAL WATCHES Watch to be tested Make sure the watch casing or the winding crown touches the active fork. Only this guarantees proper recording of the signals. 1 2 Preset the machine for recording mechanical watches ( ) lamp OFF 1. The beats are recorded on the paper if the button DIAG is activated. 2. Push AUTO for automatic beat. 3 6 5 3. Adjust lift angle.(most standard watches use 52 ). 4. If the watch signals come out weak,turn volume control knob clockwise to increase amplification until the light blinks at I/0. 4 6 5 Note: As soon as the apparatus receives a correct signal,it calculates the beat and selects the closest standard beat rate.(see standard beat list page xx ).It locks then onto this beat and starts displaying the beat with the deviation. 6. By pushing the button I/O the preselect (upper display line) can be faded out. 7. The resolution on the paper can be selected by changing the value [ X ]. (See page xx for stored values.) 8. The measuring time interval can be selected by changing the value [ SEC ]. (See page xx for stored values.) 5. Value of the beat deviation ( SEC/DAY ) by adjusting the index scale onto the recorded dot line on the paper. To measure the beat deviation in this mode,the light Scale has to be ON. Otherwise the calculated value will be on the display no matter where the index scale stands. Operating Manual B 300 page 7

TEST OF QUARTZ CRYSTAL WATCHES (LCD) General : Most of the analog quartz watches with stepper motor can be recorded acoustically on a microphone for mechanical watches ( MP 86 or other ) as well as on the Pick-up microphone for quartz crystal watches. With microphone for mechanical watch, follow instructions on page 7. With electronic Pick-up, follow instructions on page 9 MP 86 Pick - up Test and record a quartz crystal LCD watch by electronic Pick - up microphone Preset the machine for recording quartz watches. ( ) Lamp ON. First lamp on Pick-up on. Top view of Pick - up Button to select Pick - up mode Acoustical pick- up. First lamp on. (for quartz 32 khz) Push once, inductive pick-up. Second lamp on. For stepper motor ( 1-60 cycles ) Push twice, capacitive pick-up. Third lamp on. For LCD watches with 32 khz and4.19 mhz Measuring pad. Lay watch onto pad, pin in center makes contact to receive acoustical signals. Black pad receives inductive and capacitive signals 1. Place watch onto measuring pad of the Pick-up 2. Push button twice to select pick- up capacitive mode for LCD watch. 3. If necessary find best position on pad indicated by blinking lamp. 4. Push AUTO, MAN, or FREQ on B 300, the measured result will then be displayed automatically. 5. Push button DIAG if recording on paper is desired. 6. Adjust resolution by RESOL to desired value. Normal scale factor for quartz watches is 100. Only effective if recording on paper. 7. Adjust measuring time interval by TIME to the desired value. Long duration is needed to check the watches of inhibitus type. Operating Manual B 300 page 8

TEST OF QUARTZ CRYSTAL WATCHES (ANALOG TYPE) Top view of Pick - up A. Acoustic measurement by quartz frequency Button to select Pick - up mode Acoustical pick-up. First lamp on. (for quartz 32 khz) Push once, inductive pick-up. Second lamp on. For stepper motor ( 1-60 cycles ) Push twice, capacitive pick-up. Third lamp on. For LCD watches with 32 khz and4.19 mhz Measuring pad. Lay watch onto pad, pin in center makes contact to receive acoustical signals. Black pad receives inductive and capacitive signals Preset the machine for recording quartz watches. ( ) Lamp ON First lamp on Pick-up on. 1. Place watch onto measuring pad of the Pick- up 2. Push button to select acoustical Pick- up mode to test the quartzfrequency of the watch. 3. If necessary, find best position on pad indicated by blinking lamp. 4. Push AUTO, or FREQ on B 300, the measured result will then be displayed automatically. 5. Push button DIAG if recording on paper is desired. 6. Adjust resolution by RESOL to desired value. Normal scale factor for quartz watches is 100. Only effective if recording on paper. 7. Adjust measuring time interval by TIME to the desired value. Long duration is needed to check the watches of inhibitus type. B. Measure by inductivity of the stepper motor. Key test for watches with inhibition. 1. Same as above QUARTZ 0.012 2. Push button to select inductive pick- up mode until lamp light is on. 3. Same as above 4. Same as above 5. Same as above 6. Same as above 7. Same as above Operating Manual B 300 page 9

ALPHANUMERIC PRINT The indicated results of the display on the B 300 can be printed in alphanumeric form on the paper. This enables you to use the paper as a documentary for your files or records for the customer. Procedure: Simply push and hold button CONT for 2 seconds. The recording of dots will be stopped while the alphanumeric data is printed. Alphanumeric print The printed values are always the actual values on the display. Scale disk: The lines on the disk must be adjusted to the diagram. SCALE OFF SCALE ON A: 237 R: 0, 2 ms M:- 10, 26 s A: 237 R: 0, 2 ms D: + 4 s Important: The number of decimals of time deviation on the display and for result printing depends of the setting by Resolution (x). See page 13 ( technical data ). Operating Manual B 300 page 10

INSERT PAPER ROLL The spring blade will push the paper against the gliding roller by closing the cover.this is to keep the paper stretched while recording. Pass the paper over the gliding roller. B 300 requires 36 mm width paper, available from your Greiner vibrograf dealer. Thread the paper between ink ribbon and anvil cylinder. Now tilt the frontplate slowly back, so that the paper can curl back by itself. If necessary, help to tighten the paper by rolling back the excessive paper. Now close the upper cover. Make sure it snaps in correctly. Pass the paper under the index scale. Lift the pressure roller and insert the paper. Pull paper under the tear - off bar. Operating Manual B 300 page 11

CHANGE INK ROLL CASSETTE Important : The quality of the diagram is only guaranteed by using genuine ink roll cassettes by GREINER. Removal of the cassette 1. Open cover and tilt front plate forward. 2. Release the blade spring on the left side of the cassette and remove it. blade spring guide roller and guide pin (B) guide rollers (A) Mount new cassette 1. Pull ink ribbon approx. 8 cm ( 3 inch ) out of the cassette. 2. Thread the extending ink ribbon loop around the guide rollers (A ) and between the the guide roller and the guide pin (B) as shown in the picture. 3. Push cassette into its holder until the blade-springs snap. In case the drive shaft under the cassette does not engage properly, remove the cassette 2 cm and twist the knob on the cassette ccw until it does. Operating Manual B 300 page 12

TECHNICAL DATA The selectable values for : Beat selection Lift angle Resolution Time Standard beat values : adjustable with button (MAN) or, on AUTO MODE if a watch signal is present. 36 000 28 800 21 600 19 800 18 000 16 200 14 400 12 000 10 800 9 000 7 200 3 600 Beat values : Adjustable by the push button (SEL) If the light (SEL) is on, all the Beat values between 3 590 und 36 100 can be adjusted by the button (SEL) TIME : 2 sec. 4 sec. 10 sec. 20 sec. 60 sec. RESOL : for mechanical watches : No zeros are displayed in front of the result. Selectable values: on Display : Factor : Result s/d : 0.5 = 1 ± xx 1 = 2 ± xx 2 = 4 ± xx.x 4 = 8 ± xx.x 10 = 20 ± xx.xx 50 = 100 ± xx.xx 0.5 * = 1 ± xx.xx 1 * = 2 ± xx.xx 2 * = 4 ± xx.xx 4 * = 8 ± xx.xx 10 * = 20 ± xx.xx 50 * = 100 ± xx.xx RESOL: If Quartz mode is selected: Selectable values: on Display : Factor : Result s/d : 0.5 = 1 ± xx.xx 1 = 2 ± xx.xx 2 = 4 ± xx.xx 4 = 8 ± xx.xx 10 = 20 ± xx.xx 50 = 100 ± xx.xx Lift angle : 30 bis 70 Precision of B 300 Quartz : f = 9.216 MHz (tk = ± 1ppm bei 0-8 0 ) Calibration : with DCF77 radio clock < ± 0.01 s/d over several hours Operating Manual B 300 page 13

COMPUTER CONNECTION ( RS- 232 ) The back side of B 300 is equipped with a 9 pin (RS -232) serial interface for computer connection. Baud-rate 4800 Total bits 8 Stop bits 1 Parity no Connection cable between B 300 and computer : Use a direct standard cable (COM 1 - B 300 ) Current protocol : Send (upper case o and return ) " O Return " (actual display:) B 300 returns: Nummer : _ Vorwahlen : HW = 52, MZ = 2, SZ = 21600 Messwerte : A = 283, R = 0.2, M = +4 Software available: B300COMM.EXE Operating Manual B 300 page 14

HELP Informations on display: Informations or error messages on display are selfexplanatory. B 300 is out of operation: Switch off main power and wait 10 seconds before switching on again. This will reset the machine and sets all internal values back to initial setting. Checking if microprocessor is in normal operation. Check if the run lamp is blinking. Run lamp Operating Manual B 300 page 15