Network Records NetMAP Symbols Booklet - South East England

Similar documents
Identification of LV Cables

Transmission Cables Overhead/Underground Guidance

ECS COMBINED CUT-OUT AND CT CHAMBER INSTALLATION

MESP TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 400mm 2 ALUMINIUM CONDUCTOR 1.9kV XLPE INSULATED WITHOUT METALLIC SCREEN

Identification - electrical services

For reference, here is a shop drawing of how feed through lugs is shown by a manufacturer:

Metal Theft Taskforce Identification Booklet. Version 2

ECS INSTALLATION OF SERVICE WAYS AND CABLES (SCHNEIDER ELECTRIC)

ENCAPSULATED TRANSFORMERS FOR HARSH LOCATIONS

EE028: Practical High Voltage Cable Jointing and Termination

Reference Parameters for Digital Terrestrial Television Transmissions in the United Kingdom

220KV EHV NETWORK AT RELIANCE JAMNAGAR REFINERY COMPLEX

Engineering Instruction

TRANSMISSION ENGINEERING STANDARD TES-P , Rev. 0 TABLE OF CONTENTS 1.0 SCOPE 2.0 CABLES SPLICES

SECTION 5900 TRAFFIC SIGNALS CITY OF LEE S SUMMIT, MISSOURI DESIGN CRITERIA

Metal Theft Taskforce Identification Booklet

EXHIBIT A Zones Zone 1 (Urban): Zone 2 (Suburban): Zone 3 (Exurban) Blended Rates/Multiple Zones:

7 Lighting Technology

Undergrounding HV and EHV Window of Opportunity Opens

INSTRUCTION DE SÉCURITÉ SAFETY INSTRUCTION Mandatory as defined in SAPOCO/42 FIRE PREVENTION FOR CABLES, CABLE TRAYS AND CONDUITS

Friday 23 May 2014 Afternoon

DESIGN PRACTICE NOTE SIGNALLING AND HIGH VOLTAGE EQUIPMENT ENCLOSURE NOMENCLATURE REQUIREMENTS

SWA Cable - BS5467 Steel Wire Armoured PVC Eland Product Group A9S

SWA Cable BS6724 Steel Wire Armoured LSZH Eland Product Group A9L

Dynatel Advanced Cable Locator 2250

Effective earthing of screened cables

Küba compact DF. The space-saving helper in filling stations, gastronomy and the trade

Küba comfort DP. Draught-free ventilation and extremely quiet operation

ADDENDUM NO. 6 PORT OF NOME SECURITY CAMERA PROJECT RFP

Alberta Electric System Operator

Draft for Public Comment

Emtelle Aerial Blown Fibre

BJCP: Instructions to Authors. Reviews

Above Ground Cable Installation Systems Selection Guide

Installation of Optical Fiber

Introduction. Page 1. Welcome to the signage guidelines for St John Ambulance premises, updated as of May 2013.

Revision of Qualification Procedures for High Voltage and Extra High Voltage AC Extruded Underground Cable Systems

Guide for. Fibre To The Home network constructors

Thermoacoustics Technical Brochure. Product Line for Combustion Dynamics on Gas Turbine.

British Signalling What the driver sees

Cables: Positive Identification and Spiking. Approval: EO Production Revision: A

CLP s first 400kV XLPE cable application

About Us. Agenda 11/12/2014. Maximizing Benefits from Telephone and Cable Agreements. Municipal Association of South Carolina November 12, 2014

Small System Packages. Strand Dimming Systems

Dick Loveless. 20 November 2008 SLHC Workshop. Dick Loveless SLHC Workshop 20 Nov

Guidelines for using Which? Best Buy logos July 2014

Linea 75 MLM Fixed. product datasheet. Downlights IP20 IP44. Specifications ECO. Colour white. Matte white RAL 9016 (XX=MW) Colour black

VS-TV. User manual. Virtual Matrix ENGLISH

SAMPLE COURSE OUTLINE VISUAL ARTS ATAR YEAR 11

POLICY & APPLICATION GUIDE FOR 11kV POLYMERIC CABLES

Wi-Fi Lighting Controls ELECTRONIC GMBH

Electrical Services. The MCCA offers a variety of electrical services through our experienced in-house team of electricians.

Transmission Conference

COLOUR CHANGING USB LAMP KIT

If you want to get an official version of this User Network Interface Specification, please order it by sending your request to:

Pendant Light Fitting IEC Series 6470/2

Update Cable Management for Laboratory Workstations

AUSTRALIAN STANDARD AS/ACIF S008:2006 Requirements for customer cabling products

Fluxe 90 LV/RGB Adjustable

OPTICAL FIBRE CABLES. for very-high bit transmission and FTTx networks

Joint paper: Feasibility and technical aspects of partial undergrounding of extra high voltage power transmission lines

PEP-II Disassembly Technical Systems

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5

LED LOWBAY I-VALO DORA

Small System Packages. Strand Dimming Systems

TELECOMMUNICATIONS V S WATER UTILITIES NATURE STRIP CONGESTION. Leigh Trevaskis. Riverina Water County Council

Lab NotesIssue. The Unified Glare Rating System UGR as a Productivity Tool

Contact Details. British Transport Police: (24 hours) Crimestoppers: In association with:

POINTS POSITION INDICATOR PPI4

The Tego Ceiling System

1C.5.1 Voltage Fluctuation and Flicker

Residential Case Study ELECTRIC INTERIORS. MARLBOROUGH

March 4 th, Addendum No. 1. Brooklyn College Systems Integrator Broadcast Television Equipment Project No: BY019/

Custom Cabling for Entertainment, Film and TV

Dual Link DVI Receiver Implementation

Confirmed Action Notes of the DG Technical Forum meeting. April Held at ENA commencing 10:30 Attendees:

SECTION MEDIUM VOLTAGE CABLE INSTALLATION. 1. Section Underground Ducts and Manholes.

ICOMOS Charter for the Interpretation and Presentation of Cultural Heritage Sites

Data sheet: Wilo-Drain TP 50 E 101/5,5 (1~230 V)

Analogue output module DAO 081

Remote Voltage Detector - JET (RVD) Medium and High Voltage kV AC

Speed sensor MiniCoder GEL 2471

LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56

USER MANUAL. WARNING Read the instructions before using the machine. EN (Original Instruction) / 1704

HXi High Performance Power Supply Series Corsair HX1000i Power Supply

Outside Plant. A comprehensive range of splice closures fully mechanical sealed for use underground, wall mounted and pole mounted.

Updated June 2007 ARTISTIC EVALUATION. Taigh Chearsabhagh. Date of Visit: Monday 30th July 2007

BBC S RELEASE POLICY FOR SECONDARY TELEVISION AND COMMERCIAL VIDEO-ON-DEMAND PROGRAMMING IN THE UK

BRG Precision Products Title: Time Zone Styles Quick Reference Quide Document #: TZStyles_ReferenceQuide Revision: 2 Date: 01/29/2009

2.1 Introduction. [ Team LiB ] [ Team LiB ] 1 of 1 4/16/12 11:10 AM

42 LCD Overhead Video Display Support Specifications (No Electrical required on rear curtain wall)

REQUEST FOR INFORMATION

IndyGo Facility Upgrades Project 35671EE

CALL FOR POSTER PAPERS. Subsidiary Body on Scientific, Technical and Technological Advice (SBSTTA) Montreal, Canada, 10 to 14 March 2003

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

ULTRASONIC. Distance and Proximity Sensors. UFP / UPA Series. Key-Features:

Cambridge International Examinations Cambridge International General Certificate of Secondary Education

MultiMac SM. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

HVDC cable accessories

Data sheet: Wilo-Drain TP 65 E 114/11 (1~230 V)

Transcription:

Index:- Page no: Contents: 1... Guidance notes. 2... The area covered by this guide. Network Records NetMAP Symbols Booklet - South East England Version 1.2 Released October 2010 Always check with your local Network Records office or the UK Power Networks server to ensure that you are using the most up to date copy of this booklet - Tel: 08000 565866 (i) 3 1:500 (& 1:1250) view Scenery. 4 Scenery (UK Power Networks use only). 7 Primary distribution line route (EHV). 8 Secondary distribution cables (HV/LV). 9 Secondary distribution cable terminology. 12 Cable ducts. 13 Poles. 14 EHV, HV and LV sites. 15 Joints. 16 Street furniture 17 Miscellaneous. 18 Connectivity. 19 Abbreviations. 20 Cable phasing. 21 Operational status colours. 22 1:2500 view (UK Power Networks use only). Notes. 23 Primary distribution line route. 24 Secondary distribution cables. 25 Primary and secondary sites. 27 Switch types. 28 1:10000 view (UK Power Networks use only). Notes. 29 Secondary distribution cables. 30 Primary and secondary sites. (ii)

Guidance notes. The area covered by this guide: Important notice: If you do not understand the NetMAP record that you are using, please contact the UK Power Networks Network Records team for guidance on Tel: 08000 565866. The position of apparatus shown on NetMAP is believed to be correct, but the original landmarks may have altered since the apparatus was installed. It must be assumed that there is at least one service to each property, lamp column, street sign etc. Third party cables are not usually shown. When viewed in black and white, the line-style indicates the voltage. All LV cables are 4 core and all HV cables are 3 core unless otherwise stated. All cables are copper unless otherwise stated. Plan Provision Team and CableWatch Fore Hamlet Ipswich Suffolk IP3 8AA Tel: 08000 565866 UK Power Networks London UK Power Networks South East England. This is the only area where this booklet applies UK Power Networks East of England c Crown Copyright 1 2

1:500 (& 1:1250) view Scenery Scenery for UK Power Networks use only - boxed in red UK Power Networks / SPN licence Inset Network Contact xxxx IDNO for further information Area of inset network - not the asset of UK Power Networks Proposed Cross Rail route High pressure pipelines in the general vicinity Note: Pipelines are only viewable on NetMAP by UK Power Networks staff and their immediate contractors. Do not carry out any excavation without consent from the relevant agency - legally protected high pressure petroleum products pipeline route in the general vicinity - consult www.linewatch.co.uk for contacts and guidance. Pipeline contact numbers can also be found on the intranet out of hours, contact our Control Centre. Water - surface water Water - Source Protection Zone 1 Water - Source Protection Zone 2 Water - Source Protection Zone 3 section continued on next page 3 4

Scenery for UK Power Networks use only - boxed in red Scenery for UK Power Networks use only - boxed in red Historical - Scheduled Monuments Nature - Local Nature Reserve Historical - Parks and Gardens Nature - National Nature Reserve Historical - Areas of Archaeological Potential (AAP) Immediate contractors) Nature - Area of Outstanding Natural Beauty (AONB) immediate contractors) Nature - Ramsar Wetlands of International Importance Nature - National Park Nature - Special Area of Conservation (SAC) Nature - Special Protected Area (SPA) section continued on next page Nature - Site of Special and Scientific Interest (SSSI) immediate contractors) Fluid filled cables - very high sensitivity Fluid filled cables - high sensitivity Fluid filled cables - medium sensitivity Fluid filled cables - low sensitivity 5 6

Primary distribution line route (1:500 view) Secondary distribution cables (1:500 view) 7 8

Secondary distribution cable terminology (1:500 view) HV underground Secondary distribution cable terminology continued (1:500 view) LV underground mains and services HV overhead Overhead line materials LV overhead mains and services section continued on next page section continued on next page 9 10

Secondary distribution cable terminology continued (1:500 view) Various annotation Cable ducts (1:500 view).1 185 a ITC Cable size (sq. inches) Cable size (sq. millimetres) Aluminium Instrument traced cable or ITC - cable traced electronically using Cable Avoidance Tool (CAT) or similar Duct materials 11 12

Poles (1:500 view) EHV, HV and LV sites (1:500 view) 13 14

Joints (1:500 view) Street furniture (1:500 view) 15 16

Miscellaneous (1:500 view) Connectivity (1:500 view) Contaminated land reference 17 18

Abbreviations (1:500 view) Cable phasing (1:500 view) 19 20

Operational status colours (1:500 view) 1:2500 view Overhead - for lines UK Power Networks use only - boxed red Notes 21 22

Primary distribution line route (1:2500 view) Secondary distribution cables (1:2500 view) 23 24

Primary and secondary sites (1:2500 view) Primary and secondary sites continued (1:2500 view) section continued on next page 25 26

Switch types (1:2500 view) 1:10000 view - for UK Power Networks use only - boxed red Notes 27 28

Secondary distribution cables (1:10000 view) Primary and secondary sites (1:10000 view) 29 30