Configuration Guide Comtech EF Data Satellite Modems

Similar documents
DATUM SYSTEMS Appendix A

DM240XR Digital Video Broadcast Modulator With AutoEQ. Satellite Modems

DM240XR Digital Video Broadcast Modulator with AutoEQ

DATUM SYSTEMS Preliminary Appendix A

Challenge Series Satellite High Speed DVB-S2 Modulator. 70/140 MHz IF Output L-Band Output. VideoACM. Flexibility, backward compatibility

Higher-Order Modulation and Turbo Coding Options for the CDM-600 Satellite Modem

Compatibility Notes for. P300 & P400 Series Satellite Modems

Challenge Series Satellite High Speed DVB-S2 Modulator-Block Upconverter

Configuration Vestas VMP3500

Challenge Series Satellite High Speed DVB-S2 IP Modem SK-IP / SK-DV

CDM-600L. Part Number MN/CDM600L.IOM Revision 2

CDM-600L. Part Number MN/CDM600L.IOM Revision 2

The new standard for customer entertainment

TV4U QUAD DVB-S2 to DVB-C TRANSMODULATOR

Professional Radio TV, SAT & CATV Probe with IP Encap/Decap, ASI output, T.S. Analysis, HDSD SDI Output, Remote control with NMS & SNMP.

TDH 700 Main and sub unit for digital headend

Ultra-ViewRF 8HD Director Monitor. User Operation Manual

Design and Use of a DTV Monitoring System consisting of DVQ(M), DVMD/DVRM and DVRG

MyM-3S Micro Master. Installation Guide. English. design for TV

DMD20/DMD20 LBST Universal Satellite Modem Installation and Operation Manual

Professional Media Server Quick Start Guide

Simple Media Platform Quick Installation Guide V1.0-N. Simple Media Platform. Quick Installation Guide

Rack-Mount Receiver Analyzer 101

The new standard for customer entertainment

RADview-PC/TDM. Network Management System for TDM Applications Megaplex-2100/ RAD Data Communications Publication 06/03

User Instruction Manual IQDBT105. DVB-T/T2 Terrestrial Receiver & Monitor.

DVB-S2 Modem SK-IP / SK-DV / SK-TS

VIDEO ALARM VERIFICATION UNIT VIVER

RDS: The RDS, or Radio Data System, is supported in the g! interface where available.

INT-DS2 DVB-S/S2 SATELLITE MODULATOR DVB MODULATOR

Digital TV Transmitter

Dragon. manual version 1.6

L-BAND FREQUENCY CONVERTER

User Manual. TCU/RCU RF Head Control Units. TCU/RCU Analogue 11/6/

Frequently Asked Questions UDM. June 2006

T3316 IP QAM Modulator User Manual

DVB Satellite Modulator-Upconverter Wide C-, X-, Ku-, K-, Ka-band

<EDGE Looped based BER and TX measurements using ARB files on the R&S CMW 500> Products: R&S CMW500 R&S CMW- KW200 R&S CMW- KM200. <Application Note>

DigiPoints Volume 2. Student Workbook. Module 5 Headend Digital Video Processing

Digital TV Transmitter

X-Band Redundant LNB Systems

DXI SAC Software: Configuring a CCTV Switcher. Table of Contents

SD4650 DVB-T HD MODULATOR. User Manual

Operation and Installation Guide

R5 RIC Quickstart R5 RIC. R5 RIC Quickstart. Saab TransponderTech AB. Appendices. Project designation. Document title. Page 1 (25)

G.709 FEC testing Guaranteeing correct FEC behavior

Professional 4-Channel DVB Receiver and Transmodulator Item: 5213

HD4112 Quad HDMI MPEG2 HD DVBT Encoder Modulator U S E R M A N U A L

MultiMode FOMs -ST and -SMA

DataSAT ACU-2 Controller Wiring Configuration - Operation

Installation & Operational Manual

8-Way Professional Demodulator & IPTV Streamer

Optical Signals Application Plug-in Programmer Manual

5620 SAM SERVICE AWARE MANAGER MPTGS Driver Version Guide

N+1 Redundancy with the VCom HD4040 Upconverter

RADview-PC/TDM. Network Management System for TDM Applications Megaplex RAD Data Communications Publication No.

Digital Transcoder. Input: 1x QPSK/8PSK Output: 1x QAM

Digital Audio Broadcast Store and Forward System Technical Description

Sola-Sat DVB-S2 Modulator Model MS2-L

DiD. LCD Video Monitor & Video Wall Universal User Manual. Digital Information Display

Ku-Band Redundant LNB Systems

WNE CLIENT V.4.2 EMR CONFIGURATION GUIDE SEPTEMBER 30, 2010

MyM Pro 3S/6S Installation guide

AVE HOME FAGOR CVBS TO DVB-T ENCODER MODULATOR. Fagor Electr6nica

Introduction This application note describes the XTREME-1000E 8VSB Digital Exciter and its applications.

C-Band Redundant LNB Systems

Cisco D9865 Satellite Receiver

BecauseRFL andhubbel haveapolicyofcontinuousproductimprovement,wereservetherighttochangedesignsandspecificationswithoutnotice.

SQTR-2M ADS-B Squitter Generator

Cisco D9865 Satellite Receiver

AMD-53-C TWIN MODULATOR / MULTIPLEXER AMD-53-C DVB-C MODULATOR / MULTIPLEXER INSTRUCTION MANUAL

Noise Detector ND-1 Operating Manual

DX3316 IP QAM Modulator User Manual

Cisco RF Gateway 10 QAM Replication Configuration Guide

MS8631 RF WIDEBAND AMPLIFIER. MS RACK ADAPTER for Digi-8

User manual Transmodulators. Ref. 5103S/5103T/5103Q/5130

SDM-100A. Satellite Modem Installation and Operation Manual. Part Number MN/SDM100A.IOM Revision 0

A LOW COST TRANSPORT STREAM (TS) GENERATOR USED IN DIGITAL VIDEO BROADCASTING EQUIPMENT MEASUREMENTS

Operation and Installation Guide

CM 3S-TC. Triple Transmodulator 8PSK-COFDM/QAM. User manual

RSS-2T RF Broadband Automatic Switching Station

9 Analyzing Digital Sources and Cables

MANUAL ENG DT-2100 ENGLISH QPSK

V pro8 QUICK START GUIDE

TDX Headend. Quite simply a revolution

ADR-1000AS Compact Modular SMATV Headend

Commsonic. (Tail-biting) Viterbi Decoder CMS0008. Contact information. Advanced Tail-Biting Architecture yields high coding gain and low delay.

TV & Media Streaming by Ixanon

CompactMax-2 DVB-S/S2 TO DVB-T2 TRANSMODULATOR - 0 MI2100 -

S7000L. TV & Satellite Analyzer. All IN ONE. Satellite & Terrestrial. Key Features. Model Guide

1Chapter INTRODUCTION. This chapter describes the CST-5000 C-Band satellite terminal, referred to in this manual as the CST-5000 (Figure 1-1).

DVB Satellite Modulator-Upconverter Wide C-, X-, Ku-, K-, Ka-band

DVISm. DVISm - Mini Digital Video Insertion System. Quick Start Guide. Patent Pending

Miniature Synchronous/Asynchronous Fiber Optic Modems

Professional 8-in-1 TS Processor MX5308 USER MANUAL 2015/06

MyM Pro T2 Installation guide

NDS3542 Encoder Modulator Low Delay

Broadcast Satellite Modulator

QAM HD Integrated Receiver Decoder with SDI/HDMI/ASI/IP Signal Outputs. User Manual B-IRD-HD-PRO-Q HD IRD

Model 5240 Digital to Analog Key Converter Data Pack

Transcription:

Configuration Guide Comtech EF Data Satellite Modems Written for RMOS 4.3 October 2010 About this Guide The purpose of this guide is to describe the procedures for installing and configuring Comtech EF data satellite modems for use with all Uplogix appliances. Supported Models The Uplogix RMOS revision 4.3 includes support for the following Comtech EF Data Satellite Modems CDM-550 CDM-570/L CDM-570/L-IP CDM-570/L-IPEN CDM-625 Physical Installation The Remote Control (RS232) port of the Comtech modem will be connected to the Uplogix appliance using a DB-9 - > RJ-45 adapter. Connect the adapter to a serial port on the appliance using standard CAT5 cable. If you are using a 430, you will need a rolled cable. Enabling Serial Remote Mode In order for the Uplogix appliance to manage the Comtech EF Data satellite modem, the modem must be in Serial Remote Mode. Both Local Mode and Ethernet Remote Mode are unsupported. From a configured port: [admin@u3200 (port1/2)]# device execute LRS=1 From the terminal: <0000/LRS=1 From the editor: [admin@u3200 (port1/2)]# edit run current [comtech] Local = Serial Remote [comtech] exit

saving config as candidate... [admin@u3200 (port1/2)]# push run candidate pushing running-config... running-config saved to archive as current. Configuring the Comtech EF Data satellite modem 1. Use a workstation to open a terminal or SSH session to the Uplogix appliance. 2. Issue the port command to switch to the appropriate port: [admin@u3200]# port1/2 native {use the port that your Comtech modem is connected to} [admin@u3200 (port1/2)]# 3. Use the config init command to configure the satellite modem. [admin@u3200 (port1/2)]# config init --- Enter New Values --- description: []: Comtech make: [embedded]: Comtech model: CDM 550 {enter your device type- CDM 550, CDM 570, or CDM 625} os: []: os version: []: management IP: []: configure dedicated ethernet port? (y/n) [n]: console username: []: console password []: enable username: []: enable password []: serial bit rate [38400]: 9600 serial data bit [8]: serial parity [none]: serial stop bit [1]: serial flow control [none]: use null modem (rolled cable to device)? (y/n): n Do you want to commit these changes? (y/n): y 4. Issue the terminal command to start a terminal session with the modem. [admin@u3200 (port1/2)]# terminal Press ~[ENTER] to exit Connecting... Console session started. 5. Issue the <0/TFT? command to verify communication with the modem. You should see the following response: <0/TFT? >0000/TFT=2 Configuration Guide - Comtech EF Data Satellite Modems 4.3 2

Editing Comtech Configurations Accessing the Configuration Editor To begin working with the Configuration Editor, navigate to the configured Comtech port and enter the command: [admin@u3200 (port1/2)]# edit running-config <option> In this instance, we ve elected to edit the current configuration. However, you can choose to edit the previous configuration or any of the archive configurations stored on the Uplogix appliance with the same command. [admin@u3200 (port1/2)]# edit running-config? edit running-config <candidate current previous archive #> Editor Help Within the editor, using the? will provide a list of the available commands. [comtech]? <parameter> - displays parameter information and its current value <parameter> = <value> - sets parameter to value enclose value in quotes ('' or "") to preserve spaces show - shows current configuration exit - exits shell, saving config as candidate if changed Modem configuration parameters can be accessed using the three letter Comtech EF Data command or via the description. Entering a partial description will result in a list of matching parameters [comtech] tx similar parameters: Tx Interface Type Tx Framing Mode Tx FEC Type Tx Modulation Type Tx FEC Code Rate Tx Sub-Mux on/off Tx Sub-Mux Ratio Tx Data Invert Tx Reed-Solomon Encoding Tx Spectrum Invert Tx Scrambler Tx Carrier State Tx Clock Source Tx Clock Invert Tx Ternary Code Tx BERT State Tx BERT Pattern Tx Frequency Tx Power Level Tx Data Rate Tx Audio Volume Control Tx Drop Timeslot Tx LO Frequency Configuration Guide - Comtech EF Data Satellite Modems 4.3 3

[comtech] tx fec similar parameters: Tx FEC Type Tx FEC Code Rate Entering the full parameter name without value will display the possible parameter values and help information if there is any available. For example: [comtech] tx fec code rate # Parameter: Tx FEC Code Rate # Tx FEC Code Rate, where # 0=Rate 1/2 # 1=Rate 3/4 # 2=Rate 7/8 # 3=Rate 2/3 (8-PSK TCM or LDPC only) # 4=Rate 1/1 (Uncoded or No FEC) # 5=Rate 21/44 (Turbo Only) # 6=Rate 5/16 (Turbo Only) # 7=Rate 0.95 (Turbo Only) (aka 17/18) # A=VersaFEC CCM ModCode 0 - BPSK 0.488 # B=VersaFEC CCM ModCode 1 - QPSK 0.533 # C=VersaFEC CCM ModCode 2 - QPSK 0.631 # D=VersaFEC CCM ModCode 3 - QPSK 0.706 # E=VersaFEC CCM ModCode 4 - QPSK 0.803 # F=VersaFEC CCM ModCode 5-8-QAM 0.642 # G=VersaFEC CCM ModCode 6-8-QAM 0.711 # H=VersaFEC CCM ModCode 7-8-QAM 0.780 # I=VersaFEC CCM ModCode 8-16-QAM 0.731 # J=VersaFEC CCM ModCode 9-16-QAM 0.780 # K=VersaFEC CCM ModCode 10-16-QAM 0.829 # L=VersaFEC CCM ModCode 11-16-QAM 0.853 # Depending on FEC type, not all of these selections will be valid # Example: TCR=1 (which is Rate 3/4) Tx FEC Code Rate=Rate 1/1 (Uncoded or No FEC) Help text is specific to modem type. Entering the name of a parameter that does not exist will result in a no such parameter response. [comtech] alpha? no such parameter Setting Parameter Values To set the value, enter the parameter name with value as shown in the example below: [comtech] tx fec code rate=1 The TX FEC Rate has now been set to 3/4. If a user attempts to set a parameter to a value not possible for the parameter, the appliance will respond with Invalid input value, display the set of possible parameter values and the current parameter value. In the example below, the user attempted to set the TX FEC Code Rate to 8 which is not a possible value for this parameter. Configuration Guide - Comtech EF Data Satellite Modems 4.3 4

[comtech] tx fec code rate=8 Invalid input value: 8 # Parameter: Tx FEC Code Rate # Tx FEC Code Rate, where # 0=Rate 1/2 # 1=Rate 3/4 # 2=Rate 7/8 # 3=Rate 2/3 (8-PSK TCM or LDPC only) # 4=Rate 1/1 (Uncoded or No FEC) # 5=Rate 21/44 (Turbo Only) # 6=Rate 5/16 (Turbo Only) # 7=Rate 0.95 (Turbo Only) (aka 17/18) # A=VersaFEC CCM ModCode 0 - BPSK 0.488 # B=VersaFEC CCM ModCode 1 - QPSK 0.533 # C=VersaFEC CCM ModCode 2 - QPSK 0.631 # D=VersaFEC CCM ModCode 3 - QPSK 0.706 # E=VersaFEC CCM ModCode 4 - QPSK 0.803 # F=VersaFEC CCM ModCode 5-8-QAM 0.642 # G=VersaFEC CCM ModCode 6-8-QAM 0.711 # H=VersaFEC CCM ModCode 7-8-QAM 0.780 # I=VersaFEC CCM ModCode 8-16-QAM 0.731 # J=VersaFEC CCM ModCode 9-16-QAM 0.780 # K=VersaFEC CCM ModCode 10-16-QAM 0.829 # L=VersaFEC CCM ModCode 11-16-QAM 0.853 # Depending on FEC type, not all of these selections will be valid # Example: TCR=1 (which is Rate 3/4) Tx FEC Code Rate=Rate 1/1 (Uncoded or No FEC) Exiting the Editor Type exit to leave the Configuration Editor. Upon exit you will notice the configuration you edited is now saved as candidate. [comtech] exit saving config as candidate... Device execute The device execute command allows Comtech commands to pass directly from the port command line to the modem. Using the device execute command will make changes to the current running configuration on the modem. The Uplogix appliance will archive the current version of the configuration prior to p. The current version is archived in case the command places the modem in a bad state which would require a configuration rollback. Using Device Execute To change parameter values using device execute, enter the three letter Comtech command and the new value: [admin@u3200 (port1/2)]# device execute EBA=02.0 running-config saved to archive as current. EBA= [admin@u3200 (port1/2)]# device execute EBA? running-config saved to archive as current. Configuration Guide - Comtech EF Data Satellite Modems 4.3 5

EBA=02.0 In the example above you can see the Eb/No Alarm Point value has been changed to 2.0. When entering commands using device execute, the command must be in the format specified in the Comtech manual. Device execute does not correct parameter formatting like the Configuration Editor does. For example setting the CID parameter requires 24 characters to work correctly - also note to end the CID command with spaces the whole command must be surrounded by quotes: [admin@u3200 (port1/2)]# device execute "CID=COMTECH TEST " Querying Parameter Values with Device Execute To query the current value of a Comtech parameter, follow the three letter Comtech command with a? as in the example below: [admin@u3200 (port1/2)]# device execute EBA? running-config saved to archive as current. EBA=01.9 Pushing Candidate Configurations to the Comtech Modem To push a candidate file to the modem, begin by reviewing the configuration to ensure all parameters are set correctly using the show running-config command. This command displays the device's current configuration. Using the -t extension displays the configuration in a terse format. [admin@u3200 (port1/2)]# show running-config candidate t Tx Interface Type = RS422 Tx Framing Mode = Unframed Tx FEC Type = None (uncoded) with differential enconding ON Tx Modulation Type = QPSK Tx FEC Code Rate = Rate 1/1 (Uncoded or No FEC) Tx Sub-Mux on/off = Off Tx Sub-Mux Ratio = 1/9 Tx Data Invert = Normal Tx Reed-Solomon Encoding = Normal (based on the Open Network framing selected) Tx Spectrum Invert = Normal Tx Scrambler = Normal Tx Carrier State = OFF due to front panel or remote control command Power Level Mode = MANUAL mode (AUPC disabled). Tx Clock Source = Internal Tx Clock Invert = Normal Transmit Terrestrial Alarm Mask = Alarm is masked. Drop Type = T1-D4 Tx Ternary Code = B8ZS Transmit Backward Alarms Enable = 0000 Transmit ESC Type = 64k data channel Rx Interface Type = RS422 Rx Framing Mode = Unframed Rx FEC Type = Viterbi Rx Modulation Type = QPSK Rx FEC Code Rate = Rate 1/2 Rx Sub-Mux on/off = Off Rx Sub-Mux Ratio = 1/9 Configuration Guide - Comtech EF Data Satellite Modems 4.3 6

Rx Data Invert = Normal Rx Reed-Solomon Decoding = Normal (based on the Open Network framing selected) Rx Spectrum Invert = Normal Rx Descrambler = Normal Rx Clock Source = Rc Satellite Rx Clock Invert = Normal Receive Terrestrial Alarm Enable = Disables the alarm Insert Type = T1-D4 Rx Ternary Code = B8ZS Receive Backward Alarms Enable = 0000 Receive ESC Type = 64k data channel Receive Equalizer Enable = disabled Local/Remote Status = Serial Remote (RS-232/RS-485) EDMAC Framing Mode = EDMAC OFF (Idle Mode) Engineering Service Channel = Disable the high-rate ESC External Frequency Reference = Internal 10 MHz (default) Warm-up Delay = Delay off (instant on) Unit Test Mode = Normal Mode (no test) Attach a summary LNB fault to the Rx FLT status = Tx FLT status unaffected by LNB fault) Outdoor Unit Comms enable = Disabled 1:N (One For N) control = Disabled Request to Send = RTS/CTS Loop, No Action. RTS and CTS are looped, so that CTS echoes the state of RTS, but RTS does not control the ON/OFF state of the carrier HSSI Handshake Control = TA to CA loop (default) POCO feature (Power-On Carrier-Off) = POCO disabled (normal operation) DoubleTalk Carrier-in-Carrier (CnC) Mode = Off DoubleTalk Carrier-in-Carrier (CnC) PMSI Mode = Idle Tx BERT State = Off Rx BERT State = Off Tx BERT Pattern = 2047 (default) Rx BERT Pattern = 2047 (default) BERT 10E-3 Error Insert = Off BUC Power Supply enable = Disable the BUC DC Power Supply BUC 10 MHz Reference = Off BUC Output Power Enable = Off LNB DC Power Control = OFF LNB Reference = Disable LNB Reference Tx Frequency = 0070.0000 Tx Power Level = 10.0 Rx Frequency = 0070.0000 Eb/No Alarm Point = 00.1 Rx Sweep Width = 010 Rx Buffer Size = 00016 EDMAC Slave Address Range = 0020 Statistics Sampling Interval = 0 CnC Frequency Range/offset = 030 BUC Current Low Limit = 0000 BUC Current High Limit = 2000 BUC Address = 01 LNB Low Current Limit = 000 LNB High Current Limit = 500 Tx Data Rate = 00064.000 Configuration Guide - Comtech EF Data Satellite Modems 4.3 7

AUPC Parameter Setup = 004.03 Tx Audio Volume Control = +0+0 Tx Drop Timeslot = 100000000000000000000000 Tx LO Frequency = 00000- Rx Data Rate = 00064.000 Rx Audio Volume Control = +0+0 Insert Timeslot = 100000000000000000000000 Rx LO Frequency = 00000- Circuit ID String = "----------------------------------------" ESC Parameters = 300 Adjustment for the Internal 10MHz-High-stability Reference = +396 Unit Alarm Mask = 1100100000000 IP Address = 192.001.001.001.24 IP Gateway = 192.001.001.100 Traffic IP Address = 192.168.001.003 CnC Min/Max Search Delay = 010290 G.703 Clock Extension = 00 Once you have verified the candidate configuration is acceptable, you are ready to push the candidate file to the modem using the command push running-config candidate. The push commands allow you to write a previously saved configuration to a device. [admin@u3200 (port1/2)]# push running-config candidate pushing running-config... running-config saved to archive as current. When the file transfer is complete, you can view the new running configuration using the show running-config current command. [admin@u3200 (port1/2)]# show running-config current-t Tx Interface Type = RS422 Tx Framing Mode = Unframed Tx FEC Type = None (uncoded) with differential enconding ON Tx Modulation Type = QPSK Tx FEC Code Rate = Rate 1/1 (Uncoded or No FEC) Tx Sub-Mux on/off = Off Tx Sub-Mux Ratio = 1/9 Tx Data Invert = Normal Tx Reed-Solomon Encoding = Normal (based on the Open Network framing selected) Tx Spectrum Invert = Normal Tx Scrambler = Normal Tx Carrier State = OFF due to front panel or remote control command Power Level Mode = MANUAL mode (AUPC disabled). Tx Clock Source = Internal Tx Clock Invert = Normal Transmit Terrestrial Alarm Mask = Alarm is masked. Drop Type = T1-D4 Tx Ternary Code = B8ZS Transmit Backward Alarms Enable = 0000 Transmit ESC Type = 64k data channel Rx Interface Type = RS422 Rx Framing Mode = Unframed Rx FEC Type = Viterbi Configuration Guide - Comtech EF Data Satellite Modems 4.3 8

Rx Modulation Type = QPSK -- Output abbreviated in this example Rolling Back to a Previous Configuration If you need to roll back to a previous configuration on the Comtech, first identify the correct configuration. To view a listing of running configurations saved on the appliance run the show directory command: [admin@u3200 (port1/2)]# show directory Type Version Name ------- --------- ------------ Config Running Candidate running-config Current running-config Previous running-config You can confirm the configuration you would like to roll back to by reviewing the configuration by running the command show running-config <configuration name>. This command displays the device's current configuration. [admin@a210210014 (port1/3)]# show running-config previous -t Tx Interface Type = RS422 Tx Framing Mode = Unframed Tx FEC Type = None (uncoded) with differential enconding ON Tx Modulation Type = QPSK Tx FEC Code Rate = 2/3 (8-PSK TCM or LDPC only) Tx Sub-Mux on/off = Off Tx Sub-Mux Ratio = 1/9 Tx Data Invert = Normal Tx Reed-Solomon Encoding = Normal (based on the Open Network framing selected) Tx Spectrum Invert = Normal Tx Scrambler = Normal Tx Carrier State = OFF due to front panel or remote control command Power Level Mode = MANUAL mode (AUPC disabled). Tx Clock Source = Internal Tx Clock Invert = Normal Transmit Terrestrial Alarm Mask = Alarm is masked. Drop Type = T1-D4 Tx Ternary Code = B8ZS Transmit Backward Alarms Enable = 0000 Transmit ESC Type = 64k data channel Rx Interface Type = RS422 Rx Framing Mode = Unframed Rx FEC Type = Viterbi -- Output abbreviated in this example Once you have verified the configuration is acceptable, you are ready to push the file to the modem using the command push running-config <configuration name>. The push commands allow you to write a previously saved configuration to a device. The example below shows rolling back to the previous configuration version. [admin@a210210014 (port1/3)]# push running-config previous pushing running-config... running-config saved to archive as current. Configuration Guide - Comtech EF Data Satellite Modems 4.3 9

When the file transfer is complete, you can view the new running configuration using the show running-config current command. [admin@a210210014 (port1/3)]# show running-config current Tx Interface Type = RS422 Tx Framing Mode = Unframed Tx FEC Type = None (uncoded) with differential enconding ON Tx Modulation Type = QPSK Tx FEC Code Rate = 2/3 (8-PSK TCM or LDPC only) Tx Sub-Mux on/off = Off Tx Sub-Mux Ratio = 1/9 Tx Data Invert = Normal Tx Reed-Solomon Encoding = Normal (based on the Open Network framing selected) Tx Spectrum Invert = Normal Tx Scrambler = Normal Tx Carrier State = OFF due to front panel or remote control command Power Level Mode = MANUAL mode (AUPC disabled). Tx Clock Source = Internal Tx Clock Invert = Normal Transmit Terrestrial Alarm Mask = Alarm is masked. Drop Type = T1-D4 Tx Ternary Code = B8ZS Transmit Backward Alarms Enable = 0000 Transmit ESC Type = 64k data channel Rx Interface Type = RS422 Rx Framing Mode = Unframed Rx FEC Type = Viterbi -- Output abbreviated in this example -- For further details and instructions for your Comtech EF Data satellite modem, please consult the manual, which can be found here: http://www.comtechefdata.com/modemdocs.asp#manuals Configuring Uplogix monitors Uplogix monitors collect chassis and interface data from supported network devices. There are two monitors that have been implemented for the Comtech EF Data modem: chassis and remotestate. Once the modem has been initialized using the config init command, these monitors will be created with a 30 second interval. Both monitors can be run with two options: -n <count> to display multiple chronological values, and -t which will add an elapsed time value to the results. [admin@u3200 (port1/2)]# show chassis -n 4 -t Time elapsed: 0:21 Temperature: 37.0 degrees Time elapsed: 0:51 Temperature: 37.0 degrees Time elapsed: 1:21 Temperature: 37.0 degrees Time elapsed: 1:51 Temperature: 37.0 degrees Configuration Guide - Comtech EF Data Satellite Modems 4.3 10

[admin@u3200 (port1/2)]# show remotestate Eb/No: 99.9 db Remote Eb/No: -1.0 db Transmit Power Level Increase: -1.0 db Receive Frequency Offset: 99999.0 khz Buffer Fill State: 0 % Receive Bit Error Ratio: 99999.0 Information collected in monitors is available for use with the Uplogix rules engine. The rules engine can be used to create customized rules to evaluate conditions and take actions. Configuration Guide - Comtech EF Data Satellite Modems 4.3 11

Receiving technical support The Uplogix technical support website allows you to open and review support requests, browse the knowledge base and download software updates. You must have a user account to view this site. To create an account, send an email to support@uplogix.com with the subject line create account. Include this information: Organization name Account user s email address User s general contact information You may request up to 10 accounts. If you need to contact Uplogix customer support, please provide this information: Product model Serial number and software version (use the show version command from the RMOS command line) Phone: 512-857-7070 Fax: 512-857-7002 Email: support@uplogix.com URL: www.uplogix.com/support Trademark and copyright information Information in this document is subject to change without notice. 2010 Uplogix, Inc. All Rights Reserved. Uplogix, the Uplogix logo, and SurgicalRollback are trademarks of Uplogix, Inc. in the United States and other jurisdictions. All other marks referenced are those of their respective owners. Configuration Guide - Comtech EF Data Satellite Modems 4.3 12