Model JDF Field Indicator

Similar documents
DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Wall-/Pipe-Mount Level Indicator

PMG. Vibration Energy Harvesters

ABB MEASUREMENT & ANALYTICS DATA SHEET. AZ100 series Zirconia oxygen analyzer for small boiler applications

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

General Specifications

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Inductive sensor BI1.5-EG08K-Y1

Pendant Light Fitting IEC Series 6470/2

SAFJ HI-LUMEN LED S A H I L U M. LED Area Lighting for Hazardous Locations

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor With analog output BI15-M30-LI-EXI

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

DMP 331i / DMP 333i LMP 331 i

General Specifications

PROPORTIONAL VALVES Sentronic plus

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

Inductive sensor NI10-M18-Y1X-H1141

Material: Weight: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

TFR5 Room or outdoor temperature sensor. CombiTemp TM

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

TFRN Industrial RTD temperature sensor. CombiTemp TM

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

associates APPLICATION GUIDE AG334 Externally powered pulse input Rate Totalisers For models with an 'E' or 'G' suffix

TFRH Hygienic RTD temperature sensor. CombiTemp TM

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Micro-DCI 53ML5100 Manual Loader

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

TFRN Industrial RTD temperature sensor. CombiTemp TM

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Pendant Light Fittings Series 6050

Explosion Proof Audible Signal db(a) Series YA60

GOYEN PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS PRODUCT LEAFLET

Pressure transmitter For applications in hazardous areas Model IS-3

RMA 3000 Remote Meter Assemblies Specifications

EXPlora. Introduction

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

TFR5 Room or outdoor temperature sensor. CombiTemp TM

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

Operating instructions

EXLUX ECOLUX C-LUX 6480 Series

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

DATA SHEET Panorama Rudder Indicator, TRI-2

EXLUX ECOLUX 6480 Series

IEPE Premium Accelerometer, Top Connector

Rosemount 1151 Smart Pressure Transmitter

DS 201. Electronic Pressure Switch. Ceramic Sensor. accuracy according to IEC 60770: 0.5 % FSO

RIA46. Technical Information. Field meter Digital field meter with control unit for monitoring and visualizing analog measured values

Process transmitter RMA422

IEPE Premium Accelerometer, Side Connector

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

Safety Light Curtain Orion1 Extended

SQM40/41 Actuators for air and gas dampers

Thermoacoustics Technical Brochure. Product Line for Combustion Dynamics on Gas Turbine.

Modular Lube Lubrication Systems System Controls

ScreenMaster and ControlMaster Process recorders, controllers and indicator

Process Transmitter RMA 422

Viper Ex the hazard free way to precise weighing results. Ex ia. The intrinsically safe compact scales combine leadingedge

3 Cleaning. 4 Technical data

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

Explosion Proof Audible Signal db(a) Series YA60

7 Lighting Technology

SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

Pilot Valves and Nema 4 Enclosures. Innovative Environmental Solutions

Installation instructions Cable transit device Roxtec RS ES Ex

Flow Measurement SITRANS F M

RIA45. Technical Information. Panel meter Digital panel meter with control unit for monitoring and visualizing analog measured values

The full range of performance

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.

Panel-mounting Thermostats EM Series

Capacitance Level Measurement Electronic insert FEC 12

XML LED X M L L E D. Explosionproof Linear LED Lighting

Installation instructions Ex frames

Pressure Measurement Transmitters for applications with advanced requirements (Advanced)

Horn loudspeaker, Ex proof, short/long flare

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Circuit-Breakers for Motor Protection Series 8523/8

Lighting: Fluorescent Lighting FD Series: Cylindrical Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Flameproof

Datasheet EC-750 Ex DOME Camera

Liquid Level Sensor Type AKS 4100U

Champ-Pak Wall Pack Luminares

Ultrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD

Chromalog T. Technical Information. Paper recorder Mulit-channel strip chart recorder with digital measured value display

Transcription:

Data Sheet DS/JDF-EN Rev. F Model JDF Field Indicator Engineered solutions for all applications Measurement made easy Digital LCD provides reliable and clear indications Flexible configuration facilities provided locally via local LCD keypad, with 1 or 2 lines numeric indication and Easy setup menu Signal characterization improves local indication by selectable transfer function Rugged, compact, lightweight, enclosure to IP67 and Nema 4x enables installation in industrial environments High reliability redundant acquisition system ensures enhanced dependability Comprehensive certification approvals give extended applicability in plant hazardous areas Compatible with all 4 to 20 ma, 2-wire systems Product in compliance with Directive 2011/65/UE (RoHS II)

Model JDF Field Indicator Field indication as you need Model JDF field indicator provides simple and low cost remote indication of a process variable on an easy to read meter, ensuring the most useful display for any specific application. A reliable measurement is implemented by a redundant acquisition chain and by a diagnostic process that guarantee always the correct output value. In addition to parallel wiring to the transmitter, JDF200 allows series mode wiring, acting as junction box facility. JDF200 features a programmable signal display, providing alphanumeric plus bargraph indications: Two 5-digit numeric indication One graphic bargraph indication one 8-digit alphanumeric TAG indication a membrane keypad with 4 tactile feedback keys The functionality as METER is achieved by the graphic bargraph which gives an analog 0-100% indication and by the 5-digit display which gives a digital indication selectable from the following options: 4 to 20 ma 0 to 100% engineering unit Functional Specifications Input range 4 to 20 ma nominal Operating range 3.2 to 23 ma (current less than 3.2 ma will blank the display) Maximum overload 400 ma up to 30 minutes Maximum voltage drop 2.4 V DC @ full scale range (5.6 V DC in case of hardware failure) Update time 0.5 sec. Transfer functions (input to indication) User-selectable for indication as linear or square root, power of 3 / 2 or 5 / 2, horizontal or spherical tank. Predefined 22 points linearization table available on request. Operative limits Temperature limits C ( F) : Ambient The operating temperature is: 20 to 70 C ( 4 to 158 F). Loop integrity is granted without damage to the field indicator in the range 40 to 85 C ( 40 to 185 F), with display not clearly readable or blank. IMPORTANT For Hazardous Atmosphere applications see the temperature range specified on the certificate/approval relevant to the aimed type of protection. Storage 40 to 85 C ( 40 to 185 F) 2 DS/JDF-EN Rev. F Field Indicator JDF

Environmental limits Electromagnetic compatibility (EMC) Comply with EN 61326-1. Surge immunity level: 2 kv (according to IEC 61000-4 5 EN 61000 4 5) Humidity Relative humidity: up to 100 % Condensing, icing: admissible Vibration resistance Accelerations up to 2 g at frequency up to 1000 Hz (according to IEC 60068 2 6) Shock resistance Acceleration: 50 g Duration: 11 ms (according to IEC 60068 2 27) Wet and dust-laden atmospheres The transmitter is dust and sand tight and protected against immersion effects as defined by IEC 60529 (2001) to IP 67 (IP 68 on request) or by NEMA Type 4X. Aluminium and AISI housings as barrel version also comply to IP 66 as defined by IEC 60529 (2001). Hazardous atmospheres INTRINSIC SAFETY: ATEX Europe (code E1) approval II 1G Ex ia IIC Tx Ga and II 1D Ex ta IIIC Tx Da IP67 and II 1D Ex ia IIIC Tx Da IP67. IECEx (code E8) approval Ex ia IIC Tx Ga and Ex ta IIIC Tx Da IP67 and Ex ia IIIC Tx Da IP67 EXPLOSION PROOF: ATEX Europe (code E2) approval II 2G Ex db IIC Tx Gb and II 2D Ex tb IIIC Tx Db IP67 IECEx (code E9) approval Ex db IIC Tx Gb and Ex tb IIIC Tx Db IP67 Type n and Intrinsically safe Ex ic: ATEX Europe (code E3 ) type examination II 3G Ex na IIC Tx Gc and II 3G Ex ic IIC Tx Gc and II 3D Ex tc IIIC Tx Dc IP67 IECEx (code ER) type examination Ex na IIC Tx Gc and Ex ic IIC Tx Gc and Ex tc IIIC Tx Dc IP67 Intertek US (code EV) and Intertek Canada (code EU): Explosionproof US: Canada: Non-sparking US: Canada: Intrinsically safe US: Canada: Enclosure type 4X Class I, Div. 2, Groups A, B, C, D T6...T4 Class II, Div 2 Groups F, G T6...T4 Class I, Zone 1 AEx d IIC T6...T4 Gb Class II, Div 1 Groups E, F, G T6...T4 Zone 20 AEx ta IIIC T85 C...T135 C Da Ex d IIC T6...T4 Gb Ex tb IIIC T85 C...T135 C Db Ex ta IIIC Tx Da IP67 Class I, Zone 2 AEx na IIC T6...T4 Gc Class I, Div 2 Groups ABCD T6...T4 Ex na IIC T6...T4 Gc Class I, Zone 0 AEx ia IIC T6...T4 Ga Class I, Division 1 Groups A, B, C, D T6...T4 Class II, Division 1 Groups E, F, G T6...T4 When connected per drawing No. DH3260 Class I, Division 2 Groups A, B, C, D T6...T4 Class I, Zone 2 AEx ic IIC T6...T4 Gc When connected per drawing No. DH3260 Ex ia IIC T6...T4 Ga Ex ia IIIC T85 C...T135 C Da When connected per drawing No. DH3260 Ex ic IIC T6...T4 Gc When connected per drawing No. DH3260 COMBINED ATEX (code EW = E1 + E2 + E3), (code E7 = E1 + E2) COMBINED ATEX, Intertek, IECEx (code E5 = EW + EV + EU+ EI) COMBINED Intertek Approvals US and Canada Intrinsically safe (code EJ) Explosionproof (code EK) Nonincendive (code EL) COMBINED IECEx (code EH = E8 + E9), (code EI = E8 + E9 + ER) Kosha (Korea) Intrinsic Safety, Explosion Proof. REFER TO CERTIFICATES OR OPERATING INSTRUCTIONS FOR AMBIENT TEMPERATURE RANGES (WITHIN THE LIMITS OF -50 TO 85 C) RELATED TO THE DIFFERENT TEMPERATURE CLASSES DS/JDF-EN Rev. F Field Indicator JDF 3

Model JDF Field Indicator Electrical Characteristics and Options Optional indicator Integral display with integral keypad (code L1) Wide screen LCD, 128 x 64 pixel, 52.5 x 27.2 mm (2.06 x 1.07 in.) dot matrix. Multilanguage. Four keys for configuration and management of device. Easy setup for quick commissioning. User selectable application-specific visualizations. Display may also indicate customizable diagnostic messages and provides configuration facilities. The indicator is user orientable, selecting one of 4 possible positions at 90. Indications The LCD display provides the following vizualizations: 8-digit alphanumeric for tag, in the top line (left corner) one line of 6-digit with height of 8 mm. or two lines of 8-digit with height of 5 mm., including decimal point, for numeric indication of variables, selectable between current or other 2 process values, plus relevant engineering units a bargraph of 30 mm. for indication of the input current signal in percentage with 0 to 100%. Performance specifications Stated at reference condition to IEC 60770 ambient temperature of 20 C (68 F), relative humidity of 65 %, atmospheric pressure of 1013 hpa (1013 mbar). Indication accuracy digital: ±0.10 % of span (16 ma) ± 1 digit. bargraph: ±1 % Resolution 16-bit conversion. Ambient temperature effect ±0.15 % of span (16 ma), for a temperature variation from 20 C (68 F) to the operating temperature limits of 20 or 70 C ( 4 or 158 F) Electromagnetic field Meets all the requirements of EN 61326-1. 4 DS/JDF-EN Rev. F Field Indicator JDF

Physical Specification (Refer to ordering information sheets for variant availability) Materials Electronic housing and covers Aluminium alloy (copper content 0.3 %) with baked epoxy finish (colour RAL9002); AISI 316 L ss. Covers O-ring Buna N. Kit for pipe mounting AISI 316 L ss V-bolt with nuts and washers allowing installation on vertical and horizontal 60 mm. (2in) pipe. The field indicator housing provides 4 holes in the casting allowing wall mounting by 6 mm. dia. screws (not supplied).. Plates Identification and certification plates: self-adhesive attached to the electronics housing or AISI 316 ss fastened to the electronics housing with rivets or screws. Optional wired-on customer data plate: AISI 316 ss. Laser printing on metal or thermal printing on self-adhesive. For AISI 316 L ss housing it is mandatory to select option I2 or I3 for plates in AISI 316 ss. Electrical connections Two 1 / 2 in. 14 NPT or M20x1.5 threaded conduit entries, direct on housing. Terminal block Three terminals for signal wiring up to 2.5 mm 2 (14 AWG), also with connection points for test and communication purposes. Grounding Internal and external 6 mm 2 (10 AWG) ground termination points are provided. Mounting position Indicator can be mounted in any position. Mass (without options) 0.9 kg approx (2 lb); add 0.1 kg (0.2 lb) for mounting kit; add 1.05 kg (2.3 lb) for AISI housing. Packing Carton 27 x 24 x 20 cm approx (11 x 10 x 8 in.). Display (code Lx) 4-position (at 90 ) user orientable. Optional extras Metal plates (code Ix) Code I2: AISI 316 ss identification plate with laser printed tag (up to 31 characters) and scale details (up to 31 characters: lower and upper scale values and engineering unit) screwed to housing. AISI 316 ss certification plate fixed to housing by rivets. Code I1: AISI 316 ss wired-on plate with laser printed customized data (4 lines of 32 characters with 4 mm/0.16 in. height). Code I3 = I1 + I2. Design and calibration certificates (codes Cx) Tag and manual language (codes Tx and Mx) Electrical connection plug (code Z1) One certified stainless steel plug to match electrical connection thread DS/JDF-EN Rev. F Field Indicator JDF 5

Model JDF Field Indicator Mounting dimensions (not for construction unless certified) dimensions in mm. (in.) 5 121 (4.76) 91 (3.58) 130 (5.12) 18 (0.71) 100 (3.93) 54 (2.13) 120 (4.72) 107 (4.21) 54 (2.13) 31 (1.22) 107 (4.21) 26 (1.02) 55 (2.17) 2 3 4 1 1 Identification plate 2 Certification plate 3 Terminal side 4 Integral display housing 5 Space for cover removal 6 DS/JDF-EN Rev. F Field Indicator JDF

Electrical connections Wiring as remote indicator 3 2 TX + + _ 1 5 2 4 NOTE This wiring as remote indicator is not applicable for 266 pressure transmitter with surge protection option code S2 NOTE JDF200 to be used as indicator with all devices ensuring minimum voltage drop on the ext. meter terminal Wiring as junction box 3 2 TX + + _ 1 4 5 1 Power source 2 External ground termination point 3 Internal ground termination point 4 266 pressure trasnmitter 5 JDF200 field indicator DS/JDF-EN Rev. F Field Indicator JDF 7

Model JDF Field Indicator Ordering information BASIC ORDERING INFORMATION model JDF Field Indicator Select one character or set of characters from each category and specify complete catalog number. Refer to additional ordering information and specify one or more codes for each instrument for required additional options. BASE MODEL - 1st to 6th characters J D F 2 0 0 X X Field Indicator Housing material and electrical connection - 7th character Aluminium alloy 1/2 in. 14 NPT A Aluminium alloy M20 x 1.5 (CM 20) B AISI 316 L ss (I2 or I3 additional code required) 1/2 in. 14 NPT S AISI 316 L ss (I2 or I3 additional code required) M20 x 1.5 (CM20) T AISI 316 L ss painted (I2 or I3 additional code required) 1/2 in. 14 NPT C AISI 316 L ss painted (I2 or I3 additional code required) M20 x 1.5 (CM20) D Input signal/additional options - 8 th character 4 to 20 ma Options requested by Additional ordering code 7 8 DS/JDF-EN Rev. F Field Indicator JDF

ADDITIONAL ORDERING INFORMATION for model JDF Add one or more 2-digit code(s) after the basic ordering information to select all required options Integral LCD Digital LCD integral display with integrated keypad Hazardous area certifications ATEX Intrinsic Safety II 1G Ex ia IIC Tx Ga and II 1D Ex ta IIIC Tx Da IP67 and II 1D Ex ia IIIC Tx Da IP67 ATEX Explosion Proof II 2G Ex db IIC Tx Gb and II 2D Ex tb IIIC Tx Db IP67 ATEX No sparking and Intrinsic Safety II 3G Ex na IIC Tx Gc and II 3G Ex ic IIC Tx Gc and II 3D Ex tc IIIC Tx Dc IP67 Combined ATEX - Intrinsic Safety, Explosion Proof and No sparking Ex na and Intrinsic Safety Ex ic (E1 + E2 + E3) Combined ATEX - Intrinsic Safety and Explosion Proof (E1 + E2) Combined ATEX, IECEx, Intertek (USA) and Intertek (Canada) (EW + EV + EU + EI) (Note A) E5 Intertek (Canada) approval Intertek (USA) approval (Note A) EV Intertek (USA and Canada) Intrinsic Safety and Dustproof (Note A) EJ Intertek (USA and Canada) Explosion Proof (Note A) EK Intertek (USA and Canada) Nonincendive (Note A) EL IECEx Intrinsic Safety Ex ia IIC Tx Ga and Ex ta IIIC Tx Da IP67 and Ex ia IIIC Tx Da IP67 IECEx Explosion Proof Ex db IIC Tx Gb and Ex tb IIIC Tx Db IP67 IECEx No sparking and Intrinsic Safety Ex na IIC Tx Gc and Ex ic IIC Tx Gc and Ex tc IIIC Tx Dc IP67 Combined IECEx - Intrinsic Safety, Explosion Proof and No sparking Ex na and Intrinsic Safety Ex ic (E8 + E9 + ER) Combined IECEx - Intrinsic Safety and Explosion Proof (E8 + E9) Kosha (Korea) Intrinsic Safety Ex ia IIC, ExiaD 20, Ex td A20, IP67 Kosha (Korea) Explosion Proof Ex d IIC, Ex td A21, IP67 Combined Kosha (Korea) - Intrinsic Safety and Explosion Proof Operating manual (multiple selection allowed) German Italian Spanish French English Chinese XX L1 XX E1 E2 E3 EW E7 EU E8 E9 ER EI EH WM WN WP M1 M2 M3 M4 M5 M6 DS/JDF-EN Rev. F Field Indicator JDF 9

Model JDF Field Indicator ADDITIONAL ORDERING INFORMATION for model JDF XX XX XX XX XX Plates language German T1 Italian T2 Spanish T3 French T4 Tag plates Supplemental wired-on stainless steel plate I1 Identification and certification stainless steel plates I2 Identification, certification and supplemental wired-on stainless steel plates I3 Temperature Limit (mandatory for US Certifications) Installation to be performed down to -40 C (-40 F) ambient temperature NB Installation to be performed in an extended range down to -50 C (-58 F) ambient temperature NC Certificates (multiple selection allowed) Inspection certificate EN 10204 3.1 of calibration (9-point) C1 Certificate of compliance with the order EN 10204 2.1 of instrument design C6 Electrical connection plug One certified stainless steel plug (supplied loose) Z1 Note A: US Certifications require additional digit selection under Temperature Limit characteristic. For applications performed at ambient temperature range down to -50 C (option NC ) it is mandatory to permanentely protect window cover from accidental impact before installing (see specific details in the instruction manual OI/JDF200) Standard delivery items (can be differently specified by additional ordering code) Self-adhesive plastic labels in English General purpose (no hazardous area certification) Kit for pipe mounting Operating instruction manual and labels in english (self-adhesive) No inspection certificate No electrical connection plug 10 DS/JDF-EN Rev. F Field Indicator JDF

DS/JDF-EN Rev. F Field Indicator JDF 11

Contact us ABB Ltd. Industrial Automation Howard Road St. Neots Cambridgeshire PE19 8EU UK Tel: +44 (0)1480 475321 Fax: +44 (0)1480 217948 ABB Inc. Industrial Automation 125 E. County Line Road Warminster PA 18974 USA Tel: +1 215 674 6000 Fax: +1 215 674 7183 Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents - in whole or in parts is forbidden without prior written consent of ABB. Copyright 2017 ABB All rights reserved 3KXP726002R1001 DS/JDF-EN Rev. F 09.2017 ABB Automation Products GmbH Industrial Automation Schillerstr. 72 32425 Minden Germany Tel: +49 551 905 534 Fax: +49 551 905 555 Sales Service ABB S.p.A. Industrial Automation Via Luigi Vaccani 4 22016 Tremezzina (CO) Italy Tel: +39 0344 58111 www.abb.com