Datasheet - SRB301LC 24VAC/DC

Similar documents
Ordering details. Approval. Classification

Datasheet - SRB-E-201ST

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

02/11/2015

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

A V 50Hz / V 60Hz

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

GV2ME. Main. Device short name. Device application

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

Minicontactorrelay,2NO/2NC,DCoperated

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

Series CT7N Bimetallic Overload Relays

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals

Type: DILM12 10(24VDC) Article No.:

GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals

GV2ME. Main. Device short name. Device application

Multi-functional safety relay modules PROTECT SRB-E

Type: DILM25 10(24V50HZ) Article No.:

Magnecraft Power Relays

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

AS09..S 3-pole Contactors - Spring Terminals

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

I r A Protection against direct contact Finger and back-of-hand proof to VDE 0106 part 100

GV2P05. Main. Device short name. Device application

Pluggable interface relays CR-M Miniature relays

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

Kuhnke Technical Data. Contact Details

Interface Relays and Optocouplers Product group picture

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Modular pulse operated latching relay 16 A

with additional normally-open signalling contact l With integrated AS interface Safety at Work.

16 A and 25 A power contactors with or without handle

Safety dialogue solutions


Generator protection relay

Gamma instabus. Technical product information

Pluggable interface relays CR-M Miniature relays

Process Transmitter RMA 422

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

02/11/2015

LONWORKS Fibre Optic Converter

Inductive sensor BI1.5-EG08K-Y1

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

Process transmitter RMA422

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

Linear flow controls VFC Linear flow controls with actuator IFC

Assembly. Front view. LEDs. Parametrization interface. Power Bus

ODW-621. RS-232 Point-to-point applications

Magnetic and Hydraulic-Magnetic Circuit Breaker

Photoelectrics Through-beam Type PA18C.T..., DC

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

Capacitance Limit Detection nivotester FTC 420/421/422

Panel-mounting thermostats, type series EM

Datasheet. LED Transformers. LED Transformer 120W 24V V. LED Transformers

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

XT-17M-B relay - Delay-off, 1 C/O, 16 A

LONWORKS Fibre Optic Router

Linear flow control with actuator IFC

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Actuators IC 20, IC 40

Fibre Optic Modem ODW-611

4/2 Introduction. 4/4 5SV RCCBs. 4/10 5SM3 RCCBs. 4/13 SIQUENCE 5SM3/5SU1 universal current-sensitive RCCBs, type B and type B+

Bulletin 190 IEC Modular Starter System

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

Inductive sensor NI3-EG08K-Y1-H1341

Safety Light Curtains GuardShield

Fibre optic router for TP/FT-10 LRW-112PP

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Transcription:

25.02.2016-18:05:23h Datasheet - SRB301LC 24VAC/DC Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB301LC Preferred typ 1 Signalling output 3 safety contacts, STOP 0 Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks (Minor differences between the printed image and the original product may exist!) Ordering details Product type description SRB301LC 24VAC/DC Article number 101163475 EAN code 4250116201532 Replaced article number 101165472 ecl@ss 27-37-19-01 Approval Approval BG USA/CAN Classification Standards EN ISO 13849-1, IEC 61508, EN 60947-5-1 PL up e (STOP 0) Control category up 4 (STOP 0) DC 99% (STOP 0) CCF > 65 points PFH value 2, 0 x 10-8/h (STOP 0)

SIL up 3 (STOP 0) Mission time 20 Years - notice The PFH value is applicable for the combinations listed in the table for contact load (K) (current through enabling paths) and switching cycle number (n-op/y). In case of 365 operating days per year and a 24-hour operation, this results in the specified switching cycle times (t-cycle) for the relay contacts. Diverging applications on request. Global Properties Product name SRB301LC Standards IEC/EN 60204-1, EN 60947-5-1, EN ISO 13849-1, IEC 61508 Compliance with the Directives (Y/N) Climatic stress EN 60068-2-78 Mounting snaps onto standard DIN rail to EN 60715 Terminal designations IEC/EN 60947-1 Materials - Material of the housings Plastic, glass-fibre reinforced thermoplastic, ventilated - Material of the contacts, self-cleaning, positive action Weight 230 g Start conditions Automatic or Start button Start input (Y/N) Feedback circuit (Y/N) Start-up test (Y/N) Automatic reset function (Y/N) Reset with edge detection (Y/N) Pull-in delay - ON delay with automatic start 30 ms Drop-out delay - Drop-out delay in case of emergency stop 50 ms Mechanical data Connection type Screw connection Cable section - Min. Cable section 0,25 mm² - Max. Cable section 2.5 mm² Pre-wired cable rigid or flexible Tightening torque for the terminals 0,6 Nm Detachable terminals (Y/N) Mechanical life 10.000.000 operations Electrical lifetime Derating curve available on request restistance to shock 30 g / 11 ms Resistance to vibration To EN 60068-2-6 10...55 Hz, Amplitude 0,35 mm, ± 15 % Ambient conditions Ambient temperature - Min. environmental temperature 25 C - Max. environmental temperature +45 C

Storage and transport temperature - Min. Storage and transport temperature 40 C - Max. Storage and transport temperature +85 C Protection class - Protection class-enclosure IP40 - Protection class-terminals IP20 - Protection class-clearance IP54 Air clearances and creepage distances To IEC/EN 60664-1 - Rated impulse withstand voltage Uimp 4 kv Overvoltage category II To VDE 0110 - Degree of pollution 2 To VDE 0110 Electromagnetic compatibility (EMC) EMC rating conforming to EMC Directive Electrical data Rated DC voltage for controls - Min. rated DC voltage for controls 20.4 V - Max. rated DC voltage for controls 28.8 V Rated AC voltage for controls, 50 Hz - Min. rated AC voltage for controls, 50 Hz 20.4 V - Max. rated AC voltage for controls, 50 Hz 26.4 V Rated AC voltage for controls, 60 Hz - Min. rated AC voltage for controls, 60 Hz 20.4 V - Max. rated AC voltage for controls, 60 Hz 26.4 V Contact resistance Power consumption Type of actuation max. 100 mω max. 1.7 W; 1.9 VA AC/DC Rated operating voltage Ue 24 VDC 15% / +20%, residual ripple max. 10% 24 VAC 15% / +10% Operating current Ie Frequency range Electronic protection (Y/N) Fuse rating for the operating voltage 0,08 A 50 / 60 Hz 0,5 A gg D-fuse Inputs Monitored inputs - Short-circuit recognition (Y/N) - Wire breakage detection (Y/N) - Earth connection detection (Y/N) Number of shutters Number of openers Cable length Conduction resistance 2 piece 1500 m with 1.5 mm²; 2500 m with 2.5 mm² max. 40 Ω Outputs Stop category 0 Number of safety contacts 3 piece Number of auxiliary contacts 1 piece

Number of signalling outputs Switching capacity - Switching capacity of the safety contacts max. 250 VAC, 6 A ohmic (inductive in case of appropriate protective wiring) min. 10 V, 10 ma - Switching capacity of the auxiliary contacts 24 VDC, 2 A Fuse rating - Protection of the safety contacts 6 A slow blow - Fuse rating for the auxiliary contacts 2 A slow blow Utilisation category To EN 60947-5-1 Number of undelayed semi-conductor outputs with signaling function Number of undelayed outputs with signaling function (with contact) Number of delayed semi-conductor outputs with signaling function. Number of delayed outputs with signalling function (with contact). Number of secure undelayed semi-conductor outputs with signaling function Number of secure, undelayed outputs with signaling function, with contact. Number of secure, delayed semi-conductor outputs with signaling function AC-15: 230 V / 6 A DC-13: 24 V / 6 A 1 piece 3 piece Number of secure, delayed outputs with signaling function (with contact). LED switching conditions display LED switching conditions display (Y/N) Number of LED s LED switching conditions display - The integrated LEDs indicate the following operating states. - Position relay K1 - Position relay K2 - Supply voltage 4 piece - Internal operating voltage Ui Miscellaneous data Applications Emergency-Stop button Guard system Pull-wire emergency stop switches Dimensions Dimensions - Width 22.5 mm - Height 100 mm - Depth 121 mm notice Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit. notice - Wiring example

Input level: The example shows a 2-channel control of a guard door monitoring with two position switches, whereof one with positive break, external reset button (R); cross-wire monitoring and feedback circuit (H2) The control recognises cross-short, cable break and earth leakages in the monitoring circuit. Relay outputs: Suitable for 2 channel control, for increase in capacity or number of contacts by means of contactors or relays with positive-guided contacts. In case of a 1-channel control, connect the NC contact to the operating voltage and bridge S11/S12 and S21/S22. Automatic start: The automatic start is programmed by connecting the feedback circuit to the terminals X1/X2. If the feedback circuit is not required, establish a bridge The wiring diagram is shown with guard doors closed and in de-energised condition. Documents Operating instructions and Declaration of conformity (it) 303 kb, 03.01.2014 Code: mrl_srb_301lc_it Operating instructions and Declaration of conformity (es) 308 kb, 14.01.2014 Code: mrl_srb_301lc_es Operating instructions and Declaration of conformity (jp) 408 kb, 03.01.2014 Code: mrl_srb_301lc_jp Operating instructions and Declaration of conformity (nl) 307 kb, 14.01.2014 Code: mrl_srb_301lc_nl Operating instructions and Declaration of conformity (en) 910 kb, 21.01.2010 Code: mrl_srb_301lc_en Operating instructions and Declaration of conformity (fr) 309 kb, 14.01.2014 Code: mrl_srb_301lc_fr Operating instructions and Declaration of conformity (pl) 340 kb, 20.03.2014 Code: mrl_srb_301lc_pl Operating instructions and Declaration of conformity (pt) 393 kb, 22.08.2013 Code: mrl_srb_301lc_pt Operating instructions and Declaration of conformity (de) 1 MB, 30.06.2010 Code: mrl_srb_301lc_de Operating instructions and Declaration of conformity (da) 316 kb, 22.10.2015 Code: mrl_srb_301lc_da Wiring example (99) 19 kb, 04.08.2008 Code: Ksrb3l04 Wiring example (99) 19 kb, 04.08.2008 Code: Ksrb3l04 Wiring example (99) 20 kb, 22.08.2008 Code: ksrb3l11 Wiring example (99) 18 kb, 22.08.2008 Code: ksrb3l19 BG-test certificate (de) 40 kb, 28.02.2005 Code: z_l30p01

CCC certification (cn) 96 kb, 24.09.2015 Code: q_srbp02 CCC certification (en) 122 kb, 24.09.2015 Code: q_srbp01 EAC certification (ru) 833 kb, 05.10.2015 Code: q_6042p17_ru Images Wiring example Wiring example

Wiring example Internal wiring diagram K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am 25.02.2016-18:05:24h Kasbase 3.2.1.F.64I