USER MANUAL. Spy RF Relay 06416E

Similar documents
Golf ball tracker. Instruction manual

Access Converter/ 3. Operation Manual. International Headquarters. European Headquarters. B&B Electronics. 707 Dayton Road Ottawa, IL USA

RemotePoint. Navigator. User s Manual VP4150

VGA Extender over Single CAT 6 Cable with Audio Support. Model Extend both video and audio up to 1000 feet

HDMI to Composite Converter. User s Guide

VGA Extender over Cat 6 with Audio Support. Model Extend both video and audio up to 300 meters

MYE TV Audio Grabber

MWT-FM. Operation Manual. FM Single Channel Transmitter. man_mwtfm.

User Guide. Centrex Recording Interface

Owner s Manual. VGA + Audio to HDMI Adapter/Scaler. Model: P HDSC2

CGA0101 Wireless Cable Gateway Quick Installation Guide

Instant 802.3af Gigabit Outdoor PoE Converter. Model: INS-3AF-O-G. Quick Start Guide

Universal Wireless HDTV Adapter

OPERATING MANUAL. DMX512 to DALI Dekoder 7044A-H Mk4

User s Guide. 5.8GHz Wireless A/V Signal Sender

ProAV Media Extender

User Manual. Model 1351 DVI Repeater with HDCP

Model Extend HDMI audio and video connections up to 300 feet. Add up to 8 additional receivers with a dedicated network switch

OPERATING MANUAL. DMX512 to DALI Dekoder 7044A-H Mk1

Garmin GC 10 Marine Camera Instructions

Miniature Fiber-Optic 3G-SDI Extension Module. User s Manual (SDIX-100, SDIX-100C)

KODAK Video Monitor CFH-V10

One (1) fiber Detachable HDMI Extender

Ethernet over Coax EOC110K EOC110R. Instruction Manual. Ethernet over Coax Adapter Kit. Ethernet over Coax Receiver

OM2000N INSTALLATION MANUAL

User Manual MODEL: KKW700V. Non-Touch True Display LCD Monitor. Installation Guide. 7 True Display LCD Monitor (VGA Interface)

USER GUIDE. AXIS T8640 Ethernet Over Coax Adaptor PoE+ ENGLISH

Ambient Weather WS-01 Intelligent Color Changing Temperature Night Light with Ambient Backlight User Manual

T850 Day & Night Security Camera

2/4/8 Port High Speed HDMI Video Splitter with Audio

Industrial Gigabit PoE+ Injector

CrystalView DVI Micro-DL Extender

AW900mT. User s Manual. Point-to-multipoint. Industrial-grade, ultra-long-range 900 MHz non-line-of-sight wireless Ethernet systems

Owner s Manual. USB Type-C to HDMI/DVI/ VGA All-in-One Converter. Model: U444-06N-HDV4K. USB Type-C and USB-C are trademarks of USB Implementers Forum

Owner s Manual. DisplayPort/Mini DisplayPort Cable Tester. Model: T DP

Stretch HDMI TM. User s Manual (M1-2000)

OPERATING INSTRUCTIONS TOM-0431IP

OPERATING MANUAL. DMX / Constant Current Dekoder 3706A-H Mk1 RDM

Quick Installation Guide. Indoor / Outdoor Antenna, Antenna Cable & Surge Arrestor H/W: V2

Video Pattern Generator

Quick Installation Guide TV-H110 H/W: V1

U S E R M A N U A L SMIIRL 2017

Forward Т Software. SDI option. Revision as of December 19, Installation and Setup Guide. SoftLab-NSK Ltd.

OWNER S MANUAL. Model 861 Hand Held Bale Scanner # REVISED 4-10

AITech ProA/V Media Extender 5GHz Digital

Industrial 4 Port RS232/422/485 to Dual Ethernet Serial Device Server - PoE PD

OPERATING MANUAL. DMX Demultiplexer 3012B Mk2

Owner s Manual. VGA + Audio to HDMI Adapter/Scaler. Model: P HDSC1

Featuring the Cintenna TX, Cintenna RX, Cintenna RX Battery and the Cintenna AKS

HDMI Signal Booster - 4K

Owner s Manual. 10/100 Media Converters. Models: N SC-MM (850nm), N SC-15 (1310nm) 10/100/1000 Media Converters

Congratulations on your mcable purchase! The mcable delivers the best possible picture to your HD or 4K TV by up-converting 480p and 720p content to

Owner s Manual. UHD 4Kx2K HDMI Splitters. Models: B UHD, B UHD, B UHD-WM, B UHD

User Manual. AtlonA. 7 PRO HD Monitor with HDMI, VGA and Component Inputs (up to 1080p or 1920x1200) AT-DIS7-PROHD

TK-V201S TK-V401S 1.01

2-Port Video Splitter USER MANUAL VS102

VGA Video Extender over CAT5

PORTABLE SATELLITE TV SYSTEM VQ1000 OPERATION MANUAL

ServerCall Transmitter

ALPHA Personal Priority Display User Manual

MWCS-AT9-MYA MYE 900MHz (Wireless) CableSAT

Quick Start Guide ABOUT THE CAMERA

OBC II Owner s Manual Modular Fiber Optic DVI Extender w. Digital/Stereo Audio

Transvue HDMI 4K2K Scaler

VGA to Composite/S-Video Converter VGA2VID

Owner s Manual. HDBaseT HDMI Over Cat5e/6/6a Extenders

VGA over Cat5 Video Extender (UTPE Series)

In-Line or 75 Ohm In-Line

Cell Phone Signal Booster. User Manual. NEED HELP? support.weboost.com

MWCS-CC9-MYA MYE 900MHz CableSAT TV Channel Changer

ROLL-A-STRIKE. Assembly Instructions Model CONTACT INFO. Hours. Technical Support Monday to Friday (9am to 5pm EST)

Chapter 1 : FCC Radiation Norm...3. Chapter 2 : Package Contents...4. Chapter 3 : System Requirements...5. Chapter 4 : Hardware Description...

900-Lumen Portable LED Projector Part #: User manual

2.4 GHz WIRELESS SURVEILLANCE SYSTEM

DisplayPort Signal Booster - 4K

USB-C Multiport Mini Dock USER MANUAL UH3232

Kramer Electronics, Ltd. USER MANUAL. Model: VP-200Dxl. XGA Differential Amplifier / DA

Introduction. Package Contents. Installation Requirements

Class B digital device part 15 of the FCC rules

MODEL HA07 - MASTER CONTROLLER INSTRUCTIONS

Quick Start. About the Camera. Power Button Battery Status Record Button Rotating Lens Record Status Memory Status Resolution Switch

Kramer Electronics, Ltd.

3-Port Multi Monitor Mini DisplayPort to DisplayPort MST Hub

5 Port DVI Splitter VIDEO WALLS VIDEO PROCESSORS VIDEO MATRIX SWITCHES EXTENDERS SPLITTERS WIRELESS CABLES & ACCESSORIES

PC/HDTV 2-Way Converter

1X4 HDMI Splitter with 3D Support

DVI Rover 700 User Guide

User s Manual. Welcome. About the product. Safety Notice

Owner s Manual. 4K x 2K HDMI Audio De-Embedder / Extractor with HDCP 2.2. Model: P AUD4K6

Designed in Colorado, USA. Bluetooth Cable. Quick Start Guide

HD Digital MPEG2 Encoder / QAM Modulator Get Going Guide

Limited Warranty. TERK and the TERK logo are registered trademarks of AUDIOVOX Corp.

instruction manual Model 619D video dual cross hair generator s/n

HD Digital MPEG2 Encoder / QAM Modulator

Get Connected. Download the free Pure Connect app to immerse yourself in music.

Owner s Manual. HDMI over Cat5/Cat6 Active Extender with Built-in 4K Upscaler. Models: B126-1A0-SC4K and B126-1A1-SC4K

blink USER GUIDE Bluetooth capable Reclocker Wyred 4 Sound. All rights reserved. v1.0

Kramer Electronics, Ltd. USER MANUAL. Model: DVI Pattern Generator

8-Port HDMI Splitter with Up Data SP-H User Manual V

instruction manual Model 619YY video dual vertical line generator s/n

Transcription:

USER MANUAL Spy RF Relay 06416E

TABLE OF CONTENTS I. INTRODUCTION... 3 a) Equipment... 3 b) Symbols...3 II. INSTALLATION RECOMMENDATIONS... 3 a) Perturbations sources... 3 III. INSTALLATION... 4 a) Installation recommendations... 4 b) Installation of wall-mounting bracket... 4 c) Connector... 4 IV. CHARACTERISTICS... 4 V. SPY RF DECLARATION... 5 VI. TABLE RELAY CONFIGURATION... 5 VII. WARRANTY... 8 VIII. MAINTENANCE CONTRACT... 8 IX. ENVIRONMENT PROTECTION... 8 JRI 2

I. INTRODUCTION Congratulations, you own a SPY RF Relay! This device allows to relay radio communication to Spy RF out of reach from radio communication of a Modem. a) Equipment 1 Spy RF Relay 1 wall-mounting bracket 1 adhesive plaster 1 protection connector 1 user manual b) Symbols RECYCLING : do not throw in a rubbish dump or in a domestic waste container. Comply with the regulation to throw away the device. POWER SUPPLY : this device is powered by a continuous current delivered by a main power supply adaptor (230VAC). Comply to the security and utilization regulations of electric power. Use an electric installation complying with these regulations CE MARKING :this equipment is certified to comply with the European regulation for the electric security, inflammability, disturbing radiation emission and immunity to surrounding electric disturbances. FCC ID: 09595 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation In accordance with FCC requirements, changes or modifications not expressly approved by JRI could void the user's authority to operate this product. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense II. INSTALLATION RECOMMENDATIONS The Spy RF is a recorder of physical parameters able to communicate wirelessly with the operating software SIRIUS. The wireless communication is based on radio frequency. As we are daily in contact with it (radio, TV ) it is easy to think that it always works. This is true if basic rules on the positioning of recorders are respected because wireless communication is subject to perturbations. a) Perturbations sources Presence of obstacles in the way of the waves between the Spy RF ModeM and the Spy Rf (wall, ceiling, person, furniture ) or close to the antenna. Obstacles thickness in the way of the waves. The absorption is more important in diagonal as perpendicularly Waves cannot pass through full metallic walls. On the other hand, a perforated wall allows the waves passing with attenuation JRI 3

III. INSTALLATION a) Installation recommendations Place the devices at ~2m high and around 30 to 40cm from the ceiling to avoid obstacles and moving persons. If possible, place the Spy RF in central position regarding the Spy RF recorders. Try to place them preferably at sight of each other. On the wall, it is preferable to them aside by using the special bracket (ref 08512) of the catalog. Place the antenna above the top the monitored unit (fridge, incubator, oven, cold rooms ),. Never place the Spy RF horizontally. If some difficulties persist, it is possible to use Spy Rf RelaY (repeaters) or to connect another Spy RF ModeM to the Ethernet network (LAN). b) Installation of wall-mounting bracket c) Connector 230 VAC 50Hz The Spy RF RelaY has an embeded rechageable battery.! The Spy RF relay can be unplugged and moved after a 1' of battery charge. The battery is fully charged after 6 hours of charge IV. CHARACTERISTICS Operating range -0 +40 C 0-90%HR not condensing Storage range -40 + 85 C Radio range (in free field) 1km Radio band 868MHz or 902MHz Power supply 9 VDC 300mA Rechargeable battery Autonomy without power supply NIMH 6V from 19 to 32h Dimensions 123x69x30mm Protection degree IP34 CE ERM Compliance EN 301 489 / EN 61000 / EN 61010 EN 55022 / EN 300 220 FCC Compliance FCC part 15 JRI 4

V. SPY RF DECLARATION Open Sirius and follow the instructions SIRIUS <2.x SIRIUS 2.x et + The address of the Spy RF RelaY will automatically wrote in the relay table of the choosen device with (Sirius 1.5 and above) VI. TABLE RELAY CONFIGURATION For Sirius Versions <1.5 To contact wirelessly Spy RF that are out of reach of a direct access from the Spy RF ModeM, it is necessary to use intermediary device (Spy RF RelaY) as a relay antenna. That its already true for remote alarms with the Spy RF AlarM. As a reminder the configurations authorized by the Spy RF range in relay mode are: Up to 100 devices per ModeM (Spy Rf + Spy RF RelaY) for the same line of relay. It is possible to use only 2 Spy RF Relay in series To set up the relay mode, you have the possibility to use the Spy Tab software supplied in the Sirius CD or by entering manually the address of the spy RF relayed Manual set up Two lines have to be completed in more details of RelaY and ModeM configuration JRI 5

Without relay Cell to be configured Devicel Spy RF ModeM Spy RF RelaY 1 Spy RF RelaY 2 Spy RF Direct satellite relay table Multi relay table With 1 Relay level Cell to be configured Device Spy RF ModeM Spy RF RelaY 1 Spy RF RelaY 2 Spy RF Direct satellite relay table Multi relay table** With 2 Relay level Fill in the the Spy RF RelaY 1 followed by the Spy RF N relayed Fill or copy from the modem table the N of directly relayed Spy RF Cell to be configured Device Spy RF ModeM Spy RF RelaY 1 Spy RF RelaY 2 Spy RF Direct satellite relay table Multi relay table Fill in the the Spy RF RelaY 1 and 2 N followed by the Spy RF N they relay Maximum number of interrogated Spy RF Fill or copy from the modem table the N of directly relayed Spy RF Fill or copy from the modem the N of the Spy RF RelaY 2 and those of the Spy RF they relay fig 1 Spy RF ModeM Spy RF RelaY 1 Spy RF RelaY 2 Nombre de Spy RF Illimité Illimited 80 maxi* * Spy RF RelaY included 40 Max* 80 Max* 100 maxi* JRI 6

Sirius configuration To make a relay works correctly with Sirius, it is necessary to declare for each Spy RF Modem and Spy RF RelaY all the Spy RF they have to relay. Relay table declaration for Spy RF ModeM and Spy RF RelaY From Sirius home page open Device management window Select the Concerned Spy RF ModeM or Spy RF RelaY (N bigins by 70 for a Spy RF ModeM and by 80 for a Spy RF RelaY) in FLEET then click on more details in upper right side of the window The following table appears After supressing the contents (ctrl+end then del) fill the fields with the device n existing in the Fleet list witout care of the seperatorcharacter (dot) and following the instructions of the above table (fig 1). (ie: For the device 10.A0.01.00 fill 10A00100 and so on) Once all the relay tables filled click on apply configuration to transfer the configuration to all devices N STRUCTURE/ 10=Device model & A00100=serial N T T+ TH U,N,C TC RelaY AlarM 10 20 30 40 50 80 90! FOR SIRIUS UP TO V 1.3 USERS, ADMINISTRATOR OR MANUFACTURER RIGHTS ARE NEEDED TO DO THIS CONFIGURATION Installation modification If for any reason, a relayed device has been replaced in Sirius, it is necessary to modify relay tables in consequence. So: -Select the adress of the replaced device -Supress this adress with the Del key of the keyboard -Fill the adress of the replacing device without care about separators -Ones the adress filled, click in another cell of the table or press enter to validate. -do it again for each table in wich this adress had to be replaced. JRI 7

VII. WARRANTY JRI products carry a one year warranty and guarantee against defects in their components or workmanship. During this period if any product supplied by the Company proves on inspection to be defective, the Company will at its own option replace the same or refund to the Buyer the price of the product. In no circumstances will JRI' liability exceed the price of the product paid by the buyer or the cost of replacement. JRI shall not in any event be liable to the Buyer for any indirect or consequential loss or damage costs or expenses whatsoever which might arise out of or in connection with the supply of the product or its consequent use. Consequently, the products warrantee and guarantee specified above, does not cover damage caused by fair wear and tear, abnormal storage conditions, incorrect use, accidental misuse, abuse, neglect, misapplication or modification, or use with non- JRI' hardware/software. No warranty of fitness for a particular purpose is offered and the user assumes the entire risk of using the product. In line with our policy of continuous development, we reserve the right to amend our product specification without prior notice. VIII. MAINTENANCE CONTRACT How to optimize your radio frequency installation? RF measuring systems communicate by radio frequency. However, there may be several factors that can modify the radio ways already defined, such as moving from a building, adding walls, Radio frequency requires thus a periodical follow up performed by specialists. That s why JRI has created maintenance contracts. We bring you a global solution which makes your maintenance easier. This overall service offer includes maintenance and also metrological services, which ensure you that your system is fully performant. You won t worry about your devices maintenance anymore! With this maintenance contract you will benefit for a minimal period of 2 years from the following advantages: - material verification once or twice a year - warranty extension - telemaintenance - telephone assistance +33 (0) 892 680 933 (0,282 HT/min) - material replacement on site or by return in our manufacture - metrological certificates: verification of measurement accuracy - access to new software versions and updates - on-site intervention time within 3 open days after problem identification by our experts IX. ENVIRONMENT PROTECTION JRI recommends to our customers to throw away their measuring and recording devices which are unserviceable and/or beyond repair in a way that is appropriate to environment protection. Insofar as the production of waste cannot be avoided, it is best to re-use them by proceeding with adapted recycling depending on the material used and considering the environment protection. RoHS Directive The ROHS European Directive rules and limits the presence of hazardous substances in electrical and electronic equipments (EEE). In the article 2, the scope of this Directive excludes "9. Monitoring and Control Instruments" and our products are part of this category. Nevertheless, our company has decided to apply the whole dispositions of this Directive for all our new electronic devices which will comply to this 2002/95/CE Directive. JRI 8