RF Level Test System +20 dbm to 130 dbm

Similar documents
Calibrating the CMD Output Level for BER

How To Demonstrate Improved ACLR Dynamic Range With FSU and Noise Correction

Improving the accuracy of EMI emissions testing. James Young Rohde & Schwarz

Advanced Test Equipment Rentals ATEC (2832)

Determing Amplifier Nonlinearities by using Real-World Signals European Microwave Week 2003

Application Note DT-AN-2115B-1. DTA-2115B Verification of Specifations

Application Note DT-AN DTU-315 Verification of Specifications

R&S FS-Z60/75/90/110 Harmonic Mixers for the R&S FSP/FSU/ FSQ/FSUP/FSV

R&S FSV-K40 Phase Noise Measurement Application Specifications

Vector Network Analyzers

Calibrating attenuators using the 9640A RF Reference

HP 71910A and 71910P Wide Bandwidth Receiver Technical Specifications

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE Composite Distortion Measurements (CSO & CTB)

Level Accuracy and Electronic Level Settings of SMIQ

Agilent CSA Spectrum Analyzer N1996A

Modulated Wideband Power Amplifier

8650A SERIES UNIVERSAL POWER METERS

LadyBug Technologies, LLC LB5908A True-RMS Power Sensor

Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X

R&S FSMR Measuring Receiver Specifications

Advanced Techniques for Spurious Measurements with R&S FSW-K50 White Paper

Generating 3GPP Multi Carrier Signals for Amplifier Tests with R&S SMIQ03HD and WinIQSIM

NPR - Noise Power Ratio Signal Generation and Measurement

Out of Band Spurious Measurement for Bluetooth Modules

The high-end network analyzers from Rohde & Schwarz now include an option for pulse profile measurements plus, the new R&S ZVA 40 covers the

Measurements on GSM Base Stations According to Rec

Extension kit for R&S Vector Network Analysers

Tests on 3G-Base Stations to TS with R&S Spectrum Analyzers and SMIQ Vector Signal Generator

Keysight Technologies High Power Ampliier Measurements Using Nonlinear Vector Network Analyzer. Application Note

Agilent 8560 E-Series Spectrum Analyzers

Tests on 3G-Base Stations to TS with FSIQ and SMIQ

Technical Datasheet. 8650B Series Universal Power Meters 10 MHz to 50 GHz. 8651B Single Channel 8652B Dual Channel Rev.

R&S FSMR Measuring Receiver All-in-one calibration of signal generators and attenuators

e2b calibration 521 Fifth Avenue Chardon, Ohio Phone: Fax: Certificate Of Calibration

HMC7056. Block Upconverters / HPA's. Typical Applications. General Description. Features. Functional Block Diagram

OBSOLETE HMC7056. Block Upconverters / HPA's. Typical Applications. General Description. Features. Functional Block Diagram

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System

R&S FPC1000 Spectrum Analyzer Specifications

R&S ZNL Vector Network Analyzer Specifications

Mastering Phase Noise Measurements (Part 3)

Spectrum Analyzer 1.6 GHz 3 GHz HMS-X

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

Software. Documentation. Test Equipment

UFX-EbNo Series Precision Generators

E4416A/E4417A EPM-P Series Power Meters and E-Series E9320 Peak and Average Power Sensors DATA SHEET

LadyBug Technologies LLC Manual PowerSensor+ Field Certification Procedure

Spectrum Master. Compact Handheld Spectrum Analyzer. Technical Data Sheet

Power Amplifier 1.5 MHz to 18 GHz, Split Bands. Now with smart digital monitoring and control options 19 Rack Mount Family Data Sheet

SIDC-6003 MICROWAVE WIDEBAND DOWNCONVERTER / TUNER UP TO

R&S FSW-B512R Real-Time Spectrum Analyzer 512 MHz Specifications

Model 4700 Photodiode Characterizer

Spectrum Master Models MS2723B and MS2724B

SIR MICROWAVE WIDEBAND DSP RECEIVERS UP TO 26.5 GHz. WIDE FREQUENCY RANGE: GHz

ESU EMI Test Receiver Specifications

Bluetooth Tester CBT. Specifications. Specifications. Version January 2006

R&S FSW-K144 5G NR Measurement Application Specifications

SMS3000X Series Spectrum Analyzer

R&S FPC Spectrum Analyzer Unexpected performance in entry class

R&S FSW-K76/-K77 3GPP TD-SCDMA BS/UE Measurement Applications Specifications

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

Basic RF Amplifier Measurements using the R&S ZNB Vector Network Analyzer and SMARTerCal. Application Note

TRM Module. l TRM = Transmitter Receiver Module. l Communication to the module is essential. l Each module is individually tested

Be ahead in 5G. Turn visions into reality.

RS Pro SPECTRUM ANALYZER SSA3000X SERIES

Technical Description

VLA-VLBA Interference Memo No. 15

Shenzhen Zhongjian Nanfang Testing Co., Ltd.

USB-TG124A Tracking Generator User Manual

RF (Wireless) Fundamentals 1- Day Seminar

4400X Series. Orbital. X-Band Ext Ref LNB. MIL Spec MIL-STD A, 45 db internal filter LNB630S-500X-WN60-G12. Orbital Features: Orbital Specs:

ANSI/SCTE 40 Conformance Testing Using the R&S SFU, R&S SFE and R&S SFE100

R3267/3273 Spectrum Analyzers

BER Measurements on GSM Receivers under Conditions of Fading

SIDC-6005 MICROWAVE WIDEBAND DOWNCONVERTER / TUNER UP TO

Technical Data. HF Tuner WJ-9119 WATKINS-JOHNSON. Features

RF Measurements You Didn't Know Your Oscilloscope Could Make

Agilent FieldFox RF Analyzer N9912A

Interface Practices Subcommittee SCTE STANDARD SCTE Measurement Procedure for Noise Power Ratio

Collection of Setups for Measurements with the R&S UPV and R&S UPP Audio Analyzers. Application Note. Products:

LaserPXIe Series. Tunable Laser Source PRELIMINARY SPEC SHEET

11 GHz MDD FIBER OPTIC LINK FEATURES TYPICAL APPLICATIONS

R&S FSW-K160RE 160 MHz Real-Time Measurement Application Specifications

VXIbus Microwave Downconverter

Measurement of Television Channel Levels on CATV Networks

8500A. Advanced Test Equipment Rentals ATEC (2832) channel capability. For tests on pulse mod- SERIES PEAK POWER METERS

R&S FSW Signal and Spectrum Analyzer Specifications

Application Note 5098

Orbital 4400X & 4400XI Series X-Band Ext Ref LNB

R&S FPS-K18 Amplifier Measurements Specifications

Interface Practices Subcommittee SCTE STANDARD SCTE Composite Distortion Measurements (CSO & CTB)

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

R&S FPS Signal and Spectrum Analyzer Specifications

Noise Detector ND-1 Operating Manual

Tests on CDMA2000 1xEV-DO Access Terminals in Accordance to IS-866-A

RF Signal Capture & Playback Simple Operation Guide

CONTENTS 1. GENERAL INFORMATION INTRODUCTION PRODUCT INFORMATION DESCRIPTION OF TESTS CHANNEL BANDWIDTH...

Frequency. Range. HP 83751A/B: 2 GHz to 20 GHz HP 83752A/B: 10 MHz to 20 GHz. Standard 10 MHz timebase: f10 ppm

R&S HF907DC SHF Downconverter Specifications

E4416A EPM-P Series Single Channel Power Meter

Agilent E4416A/E4417A EPM-P Series Power Meters and E-Series E9320 Peak and Average Power Sensors

Transcription:

NRVD Power Meter optional Therm. Sensor A B Power: >-15 dbm DUT (Signal Generator, Communication Tester) 1 MHz - 3.5/6 GHz +20 dbm... -130 dbm Diode Sensor Z4 Power: -15 to -40 dbm 6 db Power =< -40 dbm to -115 dbm, 3 db FSP to -130 dbm with optional Low Noise Amp (gain= 26 db, N.F.= 2 db) Products: FSP, NRVD RF Level Test System +20 dbm to 130 dbm The purpose of the test setup described is to ensure or to enhance the level accuracy of signal generators or the generator part of communication testers. The level accuracy of test signals is particularly important at low levels when measuring BER level sensitivity at digital communication receivers. The highly linear FSP spectrum analyzer is used in combination with a power meter to get the best possible accuracy with high measurement speed over a very wide level range. Subject to change Minihold 11.99 1MA21_1E

Contents 1 Overview...2 2 General measurement principle...2 3 Suggested test setup...3 4 Description of level measurement...4 5 Appendix:...7 Appendix 1: Hints to additional equipment of the level test system... 8 Appendix 2: Uncertainty calculation (Excel Sheet)...7 6 Ordering information...8 1 Overview The purpose of this test setup is to ensure or to enhance the level accuracy of signal generators or the generator part of communication testers. The level accuracy of test signal is very important, especially at low levels when measuring the BER level sensitivity of digital communication receivers. For the sensitivity measurement of receivers at base station and mobiles in different digital standards, the following levels have to be applied and are therefore effectively the lowest levels (minus some extra db s) which have to be calibrated: Table 1 Static BER Levels in different Digital Communication Standards Communication Standard GSM 900/1800/1900 IS 136 IS 95 BER Sensitivity Level -104 dbm -110 dbm -104 dbm 2 General measurement principle By far the most accurate instrument for level measurement is a power meter with a thermocouple power sensor. However the sensitivity of a thermocouple sensor is limited to about -20 dbm to -30 dbm. A power meter with a diode sensor is more sensitive and provides accurate level measurement down to about -50 dbm. Levels far below 50 dbm can only be measured by a selective device like a spectrum analyzer (or a receiver). However, the absolute level accuracy of these instruments is quite low compared to that of a power meter. So the idea of the level tester is to calibrate the spectrum analyzer readings for each test frequency at a level which can be measured well by a power meter, such as -40 dbm. When the level is lowered further, only the linearity error of the analyzer contributes to the overall level uncertainty. The R&S FSP spectrum analyzer shows a very low linearity error at bandwidths 30 khz (digital IF filter), so that the measurement accuracy remains high. Thus levels down to -130 dbm and even below can be measured with high precision. If the range setting of the FSP has to be changed, renormalize the FSP at the same level in the new range. Thus the FSP's range setting 1MA21_1e 2 Rohde & Schwarz

uncertainty does not contribute to the overall measurement uncertainty either. Measuring the power of CW signals will in general give the most accurate results and can be done down to the lowest level because very small measurement bandwidths can be used. However the signal power of a DUT may change when switching from CW to a digitally modulated signal. If the purpose of the test is to ensure the level accuracy of the modulated signal, the modulations s influence to the output level should be tested first at a reference point and taken into account for all following CW measurements. 3 Suggested test setup The suggested test system contains an FSP spectrum analyzer, an NRVD power meter with one (or two) power sensors, optionally an NRV-Z51 thermocouple sensor and an NRV-Z4 sensitive diode power sensor. To switch between the different paths, a low VSWR switch is required (see appendix 2). If signal levels below approximately 115 dbm have to be measured, a low noise amplifier is also necessary. optional Therm. Sensor (only necessary for power > -15 dbm) NRVD Power Meter A B DUT (Signal Generator, Communication Tester) 1 MHz to 3.5/7 GHz +20 dbm to -110 dbm (-130 dbm) Power: >-15 dbm Diode Sensor Z4 Power: -15 to -40 dbm 6 db 3 db FSP-3/7 Level < -40 dbm to -110 dbm to -130 dbm with optional Low Noise Amp (G= 26 db, N.F.= 2 db) Fig. 1 Schematic diagram of test setup 1MA21_1e 3 Rohde & Schwarz

4 Description of level measurement If digitally modulated signals are to be measured, the influence of digital modulation on the output power of a device (compared to a CW signal) should be tested in advance. Switching on digital modulation in a signal generator or communication tester usually changes the internal signal path by switching in or out various components (like an I-Q modulator). This may have some influence to the output level. Therefore the difference in indication between modulated and unmodulated signal should be noted as a correction factor. It can be measured either with the thermocouple power sensor at a level > -15 dbm or if it is not available - with the diode sensor as well at a level of -40 dbm. At -40 dbm the diode sensor remains in the square law region even for signals with high crest factors such as IS95 signals. Thus the error due to the crest factor is negligible. For TDMA signals the power ramping has to be switched off. Use the FSP in zero span mode to test also if there is any change in level dependant on power ramping. After getting the correction factor, set the device to CW. All the following measurements are done in CW taking this correction factor into account. This technique is applicable for lower levels, because they are achieved by switching in additional attenuation before the output, so that the relative difference between modulated and non-modulated signal remains the same. The power of the DUT is measured then in up to four ranges : Table 2: Level ranges, measuring devices and VSWR of measurement paths No. Level range Measuring device Description/Setting VSWR of measuring path 1 (optional) 2-15 dbm to - 40 dbm 3-40 dbm to - 80 dbm > - 15 dbm power meter + thermocouple sensor power meter + diode sensor Spectrum analyzer (FSP) 4 < -80 dbm Spectrum analyzer (FSP) NRVD + NRV-Z51 NRVD + NRV-Z4 Ref - 40 dbm, Atten.: 10 db (with amp: Ref -20 dbm, Atten.: 10 db) Ref - 60 dbm, Atten.: 0 db (with amp: Ref 40 dbm, Atten.: 0 db 1.1 for f<= 2 GHz 1.1 for f <= 2 GHz 1.15 for f<= 2 GHz 1.3 for f <= 2 GHz The upper two ranges are measured using two power sensors. If level range < -15 dbm is sufficient, only one range and one detector are required. Levels above about -15 dbm (if necessary) are measured by the NRV-Z51 thermocouple power sensor which is insensitive to harmonics of the DUT. Signal generators and the generator part of a communication tester typically show harmonics of -30 dbc which may cause significant measurement errors when measuring with a power meter with diode sensor beyond the square law region. 1MA21_1e 4 Rohde & Schwarz

Levels below -15 dbm down to 40 dbm are measured by the more sensitive NRV-Z4 diode sensor which is in the square law region at these levels for CW signals and therefore also insensitive to harmonics. Both detectors show a very low VSWR (1.1 for f < 2 GHz), so that the level measurement uncertainty contribution due to source mismatch is low. The lower two ranges are measured using the FSP. At a level of about 40 dbm a reference point is set at each measurement frequency: the measurement is done first by the power meter and then by the FSP with a small resolution bandwidth, and its reading is normalized to the power meter indication. The absolute level measurement uncertainty of the FSP is therefore eliminated along with the level uncertainty caused by the mismatch of the FSP path. For lower power levels than -40 dbm, only the very low linearity error of the FSP (Linearity error < 0.2 db in the range 0 db to -70 db, Standard uncertainty: 0.07 db) and the uncertainty due to S/N at very low levels contribute to the overall level uncertainty. If levels below 80 dbm have to be measured, the FSP has to be set to a more sensitive range to keep inside the high linearity region (see table 2). To avoid additional error contributions due to range switching, normalise at 80 dbm, correct the indication from more sensitive range to previously recorded reading. FSP Display Non-Linearity RBW = 300 Hz Error /db 0, 5 0, 4 0, 3 0, 2 0, 1 0-0,1-0,2-0,3-0,4-0,5 0 10 20 30 40 50 60 70 80 90 Rel Level /db Fig. 2: Linearity of 10 different FSP samples Note: The FSP measures in digital bandwidths (preferably 10 Hz for optimum S/N) where the analog logamp which can cause unpredictable linearity error of up to 0.5 db is avoided. The IF signal inside the FSP is then sampled directly by an 12 bit A/D converter which is extremely linear due to a special dither circuit. The measurement is done in Zero Span mode using the Summary Marker RMS. The Summary Marker RMS integrates the power over time to achieve the best possible stability per measurement time (sweep time). Therefore the sweep time can be set low even at moderate S/N. Increasing the sweep time of the FSP achieves better stability, especially at lower S/N at low levels. A sweep time of 3 s is adequate at -115 dbm without amplification and even at 130 dbm with amplification. 1MA21_1e 5 Rohde & Schwarz

To achieve sufficient frequency accuracy when measuring with 10 Hz resolution bandwidth, synchronise the device under test to the FSP by using the same reference frequency. Note: The VSWR of the device under test must not change for levels < - 80 dbm (optimally: for levels < -40 dbm) otherwise additional level uncertainty occuring due to variation in the source VSWR in combination with the VSWR of the FSP path take place. With all R&S signal generators (SMT, SME, SMIQ), before or at -40 dbm a 40 db attenuator is switched in directly before the output connector so that any additional switching does not noticeably influence the output VSWR. With R&S CMD55/57 communication testers, fixed attenuators (e.g. 20 db) are immediately before the output connectors (RF 1 IN/OUT, RF 2 Out) so that the output VSWR remains stable as well. When calibrating other equipment than R&S generators and Communication testers, the behaviour of the VSWR when lowering the level beyond - 80 dbm has to be tested and taken into account. The signal generator HP ESG-D Series, for example, change output VSWR at or before -60 dbm. An uncertainty calculation (Excel sheet) for level measurement at -110 dbm at 2 GHz (without amplifier) is added in the appendix. The calculation is done according to the ETR 028 ETSI recommendation. The following assumptions are made: DUT does not change output VSWR for levels <= -40 dbm (at one frequency). Output VSWR of DUT: 1.5, VSWR of measurement paths as in table 1 (VSWR of switch: 1.1 up to 2 GHz). This leads to an expanded combined standard uncertainty (95 % confidence) of 0,26 db. 1MA21_1e 6 Rohde & Schwarz

5 Appendix: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 Appendix 1: Uncertainty calculation (Excel Sheet) Combined Standard Uncertainty in db 0.1321 60 61 A B C D Level measurement uncertainty calculation, assumption: DUT does not change output VSWR below -40 dbm Data Intermediate results Uncertainty due to Powermeter/NRV-Z4 to 2 GHz at Level in dbm -40 1.000E-07 Standard Uncertainty in db (1 σ). Noise in pw (with filter No. 3, 2σ ) 320 3.20E-10 Standard Uncertainty 0.0070 Zero Error in pw (rectangular distribution) 50 0.00217 Standard Uncertainty 0.0013 Calibration Uncertainty (2σ) in db 0.06 Standard Uncertainty 0.0300 Linearity Error in % Power (2σ) 0.7 Standard Uncertainty 0.0152 Temp. Effect 18 to 28 in % Power (1σ) 0.3 Standard Uncertainty 0.0130 Powermeter Acc. In % Power (rectangular distribution) 0.3 Standard Uncertainty. 0.0075 Sum Uncertainty Powermeter 0.0375 Uncertainties due to mismatch: Mismatch at D.U.T output-switch VSWR of D.U.T 1.5 S11 of Switch 1.1 Standard Uncertainty. 0.0586 Mismatch at powersensor-switch VSWR Sensor 1.1 S22 of Switch 1.1 Standard Uncertainty. 0.0139 Uncertainty due to Mismatch D.U.T Output-powersensor VSWR DUT 1.5 VSWR SENSOR 1.1 0.0529 Standard Uncertainty. Sum Standard Uncertainty due to mismatch (measurement with NRV-Z4). 0.0801 Uncertainty S21 Measurement of path d.u.t to sensor in db(rectangular distribution) 0.05 Standard Uncertainty. 0.0289 Linearity Error of FSP at digital BW Specification in db (Special calibration) 0.2 Standard Uncertainty. 0.0700 Uncertainty due to reproducability of Switching Level in db (rectangular distribution) 0.03 Standard Uncertainty 0.0173 Uncertainty due to S/N at -110 dbm (without Low Noise Amp) Measured standard uncertainty in db with 3 s meas. time 0.06 0.0600 Expanded Combined Standard Uncertainty in db (95% Confidence) 0.2590 1MA21_1e 7 Rohde & Schwarz

Appendix 2: Hints to additional equipment of the level test system a) Switch: Dependant on the power levels which need to be tested (max.test level < -15 dbm or max. test level > -15 dbm) a SPDT-switch or a multiport switch is necessary. Choose a low VSWR type like: HP 8762 B (SPDT) or HP 87104 B (SP4T). b) For testing power levels below 115 dbm a low noise amplifier is needed to increase the S/N of the level measurement. The low noise amplifier has to have the following features: Needed frequency range (e.g. 1 MHz to 2 GHz) High gain (> 20 db) Medium output power (power at amplifier output should be at least 20 db below 1-dB-compression point). The Pico Amps type PA2-0350- 26 is a well proven amplifier used in R&S test systems (frequency range: 300 khz 5 GHz, N.F.= 2.5 db, gain = 21 db). A combination of 2 of such amplifiers and three 6-dB attenuators (in front of the first amplifier, in between and after the second amplifier) to improve amplifier VSWR and thus enhance measurement accuracy is recommended. 6 Ordering information Spectrum-/Signal Analyzer FSP-3 9 khz... 3 GHz 1093.4495.03 FSP-7 9 khz... 7 GHz 1093.4495.07 Dual Channel Power Meter NRVD 857.8008.02 Power Sensor NRV-Z4 20 mw, 6 GHz 828.3618.02 NRVD-Z51 100 mw, 18 GHz 857.9004.02 1MA21_1e 8 Rohde & Schwarz