Digital Flow Switch for Water 3 -color/2-screen display

Similar documents
Digital Flow Switch for Water

3 -color/2 -screen display

Digital Flow Switch for Air/Water

Digital Flow Switch for Large Flow

Electromagnetic Type Digital Flow Switch

Electromagnetic Type Digital Flow Switch

Electromagnetic Digital Flow Switch

3-color/ 2-screen display 1

100 : 1. Digital Flow Switch. PFMB Series 66 % 67% 76 % 81% 2-Color Display (Only 200 L type) Compact, Space saving

How to Order. Flow rate (l/min) Applicable models PFA710, PFA750. Nil

Mechanical flow switch for On/Off control

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

Digital Gap Checker to 0.15 mm (Displayable/Settable range: 10 to 300) G type Rated distance range. Workpiece. Large gap. Workpiece.

Digital Gap Checker. Workpiece. Large gap. Workpiece. Workpiece. Small gap. Detection surface Detection nozzle. Air STEP 2 STEP 3

WIRING. Connection connector. NPN output type Standard type. Main circuit. High-function type. Main circuit. PNP output type.

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

Digital Gap Checker to 0.15 mm (Displayable/Settable range: 10 to 300) G type Rated distance range. Workpiece. Large gap. Workpiece.

Electromagnetic Type Digital Flow Switch

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Pressure Sensor. PSAN Series. Compact Digital Pressure Sensors. Features Pressure Measurement Range (Negative, Standard, Compound)

Single Point Flow Monitor SW118 SW119

Pressure Sensor. Ordering Information. Mini-Cube Pressure Sensor with Easy-to-Read LED Display

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

GC61 Digital Pressure Gauge. Operation Manual

GC30 Digital Differential Pressure Gauge Operation Manual

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Photoelectric Sensors E3F2

Flow Monitor PF3W3##

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

Selection matrix for electronic pressure switches

Metric Series. PXM409 Differential Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar

Absolute Rotary Encoder E6CP

PROPORTIONAL VALVES Sentronic plus

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

FLOMAT Electromagnetic Insertion Flowmeter

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

High efficiency pumps with LCD display electronically controlled HEP Optimo L series, H2 product group

Solid-State Digital Timer

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap

Linear encoders without bearings incremental System for linear motion feedback

Micro-Machined Silicon Transducers

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

Absolute Encoders Multiturn

Operating Instructions

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

Digital Flow Monitor PFG3#0

100:1. 74 % reduction. 78 % reduction. 1 l/min. Expanded flow range. Compact, Space saving. 3-Colour Display Digital Flow Switch

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

APPLICATIONS. Automatic warehouse. Trasportation lines

02/11/2015

APPLICATIONS. Automatic warehouse. Trasportation lines

FLOMAT. Flowmeters. Electromagnetic Insertion Flowmeter: Series. Instrumentation for fluids

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

Separate Thin Amplifier type. AP-V40AW Series

Signet 2250 Hydrostatic Level Sensor

Flow Switch. Flow Switch

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Wall-/Pipe-Mount Level Indicator

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

UV Power Monitor. incident light 200 to 370 nm 300 C (Use at temperatures below the Fiber Unit s rated operating

7 SegmneDisplay Unit With High Bright Characters (D1SC-N : W32 H57mm, D1SA Series: W11 H22mm)

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Technical data. General specifications. Indicators/operating means

Modular Lube Lubrication Systems System Controls

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Solenoid valves VZWD, directly actuated

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Bimetal Temperature Switch

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

The full range of performance

Revision 1.2d

Cylindrical Photoelectric Sensor CY-100 SERIES

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Model KBF 1020 Constant climate chambers with large temperature / humidity range

Pressure transmitter COMPACT IO-Link,

Panel-mounting thermostats, type series EM

Model KBF 115 Constant climate chambers with large temperature / humidity range

Hybrid Chart Recorder 250 mm (10")

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

MODEL: 40DPT. Digital Panel Meters 40 Series. [3] OPTIONS blank: none /Q: With options (specify the specification)

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF610-Q8

Multifunction Digital Timer

Series CT7N Bimetallic Overload Relays

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Level Measurement Point level measurement - RF Capacitance switches

ATEX. 50D (Pneumatic) Electronic pressure switch bar, bar, bar, bar, bar

800 Displaying Series Flowmeter

Panel-Mounted Thermostat

SCALE & WEIGHT DISPLAYS

.152 (3.86) KEYWAY DEPTH .033 (.84).066 (1.68) .550 DIA (13.97) MOUNTING SURFACE .350 (8.89) 3/8-32 UNEF-2A THREADS (19.71.

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

Installation and Maintenance Instructions for GC51 Rangeable Pressure Transmitter

Transcription:

3-color display New Digital Flow Switch for Water 3 -color/-screen display RoHS Main screen Sub screen Note 3) Main screen Sub screen Note 3) Instantaneous flow rate Set value Note ) ccumulated value Peak/ottom value Instantaneous flow rate Note ) Note ) Main screen shows the instantaneous flow rate only. Note ) Fluid temperature can be displayed only when the digital flow switch with a temperature sensor is selected. Note 3) Sub screen can be turned off. Line name Fluid temperature Note ) New Flow range: Line up 5 L type Integrated flow adjustment valve and temperature sensor Flow adjustment valve Remote type PVC piping type Temperature sensor Series Remote sensor unit Remote type 3-color display Digital flow monitor pplicable fluid: Deionized water, chemical, etc. Integrated type and remote type added to series. IP65 CT.ES-8C

Digital Flow Switch for Water 4% 4% smaller than existing product 7 66.4 Reducing piping space Shortened 74-3 PFW74-3 (Existing product) 3 5 Straight piping length 4 PFW74 74 Existing product requires a straight piping length at least 8 times the piping diameter. Refer to straight piping length and accuracy. (pages 5 and 3) Temperature sensor Display range: to C (Temperature sensor alone) Minimum setting unit: C nalog output: Current output/voltage output Flow adjustment valve Space saving and reduced piping labor Temperature display Temperature sensor Fluid temperature: to 9 C Ethylene glycol aqueous solution can be used Example) Flow control of the circulating fluid in a chiller Customer s machine Rotatable display Display can be rotated in increments of 45 to suit the installation conditions. Easy operation, improved visibility. Counterclockwise 9 Clockwise 5 35 turn OUT IN OUT (No rotation) Non-grease OUT IN IN Mounting 8 turn 9 turn racket mounting Direct mounting Panel mounting Front protective cover Panel mount adapter Features Tapping screw (4 pcs.) Waterproof seal (accessory) Panel Mounting screw (M3 x 8 L) (accessory)

Series PVC piping Integrated type Remote sensor to 6 3/8,/ Ethylene glycol aqueous solution 5 to 4 /,3/4 Deionized water Chemical Monitor 3/4, to 5 4, to 5 3 to New 5 New 3 to 5 How to Order Specifications (Integrated Display) Specifications (Remote Sensor Unit) 3 Flow-rate Characteristics (Pressure Loss) 5 Wetted Parts Construction 6 Dimensions 7 3-color display Digital flow monitor can copy to up to The settings of the master sensor (source of copy) can be copied to the slave sensors. Made to Order switches simultaneously. Copy Reducing setting labor sensor Slave side unit Minimizing risk of Master (source of copy) (copy destination) mistakes in setting 3-Color Display Digital Flow Switch for PVC Piping How to Order Specifications (Integrated Display) units units Specifications (Remote Sensor Unit) 3 Wetted Parts Construction 4 Dimensions 5 Made to Order 7 Indicator Visually check status of sensor via indicator. Reducing wiring labor by connector e-con connector No tools and peeling required 3-Color Display Digital Flow Monitor for Water 3 How to Order 8 Specifications 9 Dimensions M8 connector Flow rate: High linking green/fast Flow rate: Low linking green/slow Rated flow or less OFF Rated flow or more Red ON PVC piping type Monitor 3/8 3-Color Display Digital Flow Switch for Water sensor.5 to 4 Water 3-Color Display Digital Flow Switch for Water Power supply/output connection lead wire Remote Flow adjustment valve/temperature sensor Port size Flow Flow adjustment None adjustment Temperature valve + Temperature Rc, NPT, G sensor valve sensor 3-Color Display Digital Flow Switch for PVC Piping Integrated Rated flow range (L/min) 3 pplicable fluid Type INDEX 3-Color Display Digital Flow Monitor for Water Variations 5 L/min added Wetted Parts Pipe CPVC (Heat resistant PVC) Function Details ody PPS pplicable Fluid 4 Seal FKM Features Function Details Measured flow rate

3-color display Digital Flow Switch for Water Series How to Order RoHS For how to order of remote monitor unit, refer to page 8. Symbol Nil S Remote sensor unit Integrated display Note ) External input: The accumulated value, peak value, and bottom value can be reset. Note ) For units with temperature sensor, OUT can be set as either temperature output or flow rate output. Setting when shipped is for temperature output. Remote sensor unit Output specification/temperature sensor Options/Part No. 5 7 5 4 3 T 7 4 3 T M Type Remote sensor unit Integrated display Rated flow range (Flow range) Symbol Rated flow range 4.5 to 4 L/min to 6 L/min 4 5 to 4 L/min to L/min 5 to 5 L/min Thread type Nil Rc N NPT F G ISO8 equivalent Port size Integrated display Output specification/temperature sensor OUT OUT Symbol Flow rate Flow rate Temperature nalog to 5 V nalog 4 to m nalog to 5 V nalog 4 to m External input Note ) External input Note ) () () Note ) Note ) (nalog to 5 V) Note ) nalog to 5 V C D E F G H T T CT DT ET FT (nalog 4 to m) (nalog to 5 V) (nalog 4 to m) Symbol Port size 3 3/8 4 / 6 3/4 / /4 4 / 4 Rated flow range 4 nalog 4 to m nalog to 5 V nalog 4 to m When optional parts are required separately, use the following part numbers to place an order. Description Part no. ZS-4-K racket Note) ZS-4-L ZS-4-M Lead wire with M8 connector ZS-4- OUT Symbol Flow rate nalog to 5 V nalog 4 to m T nalog to 5 V Flow adjustment valve With/without flow Rated flow range adjustment valve 4 4 None Yes Note ) and 5 L/min types with flow adjustment valves are not available. Note ) The flow adjustment valve of this product is not suitable for applications which require constant adjustment of flow rate. To use in combination with remote monitor (3 series), select analog output of to 5 V of flow rate (output symbol - or -T ). Note) nalog output of 4 to m with temperature sensor is made to order. (Refer to page.) Qty. Note ) Note ) Note ) For 74/7/54/5 For 74/54 For 7/5 Note) For units with flow adjustment valve, brackets are required. OUT Temperature nalog to 5 V Note Lead wire length (3 m) Temperature sensor None With temperature sensor Temperature sensor None With temperature sensor With 4 tapping screws (3 x 8) With 4 tapping screws (3 x 8) With 4 tapping screws (4 x ) The certificate is written in both English and Japanese. Integrated display type with temperature sensor can only display flow rate. racket (Option) Nil None racket R Made to Order X9 Seal material EPDM X8 nalog 4 to m output type Note) X43 Piping material brass Note) pplicable only for remote type with temperature sensor (Refer to page.) Calibration certificate (Only flow sensor) Nil None With calibration certificate Note) With bracket is not available for 5 L/min type. Integrated display/unit specification Symbol M G F J Remote sensor unit/unit printed on label Symbol Instantaneous flow rate Temperature Nil L/min C L/min G C/F (gal/min) Under the New Measurement Law, units other than SI (symbol Nil ) cannot be used in Japan. Note) G: Made to Order Reference: [L/min].64 [gal/min] [gal/min] 3.785 [L/min] F = 9/5C + 3 Instantaneous flow rate L/min gal/min gal/min L/min ccumulated flow L gal gal L Temperature C C F F Under the New Measurement Law, units other than SI (symbol M ) cannot be used in Japan. Note) G, F, J: Made to Order Reference: [L/min].64 [gal/min] [gal/min] 3.785 [L/min] F = 9/5C + 3 Lead wire Nil With lead wire with M8 connector (3 m) N Without lead wire with M8 connector

3-color display Digital Flow Switch for Water Series Specifications (Integrated Display) Refer to Handling Precautions for SMC Products for Flow Switch Precautions and the Operation Manual in our website for Specific Product Precautions. Model 74 7 74 7 7 pplicable fluid Detection method Water and ethylene glycol aqueous solution (with viscosity of 3 mpa s [3 cp] or less) Note ) Karman vortex Rated flow range.5 to 4 L/min to 6 L/min 5 to 4 L/min to L/min 5 to 5 L/min Display flow range.35 to 5.5 L/min.7 to. L/min 3.5 to 55. L/min 7 to 4 L/min to 35 L/min (Flow under.35 L/min is displayed as. ) (Flow under.7 L/min is displayed as. ) (Flow under 3.5 L/min is displayed as. ) (Flow under 7 L/min is displayed as ) (Flow under L/min is displayed as ) Set flow range.35 to 5.5 L/min.7 to. L/min 3.5 to 55. L/min 7 to 4 L/min to 35 L/min Minimum setting unit. L/min. L/min L/min L/min Conversion of accumulated pulse (Pulse width: 5 ms).5 L/pulse. L/pulse.5 L/pulse L/pulse L/pulse Fluid temperature Display unit ccuracy Repeatability Temperature characteristics Operating pressure range Note 3) Proof pressure Note 3) Pressure loss (without flow adjustment valve) to 9C (with no freezing and condensation) Instantaneous flow rate: L/min, ccumulated flow: L Display value: 3% F.S. nalog output: 3% F.S. % F.S. Note ) 5% F.S. (5C reference) to MPa.5 MPa 45 kpa or less at the maximum flow 6 kpa or less at the maximum flow ccumulated flow range Note 4) Switch output Maximum load current Maximum applied voltage Internal voltage drop Response time Note ), 5) Output protection Output Flow rate mode Temperature Response time Note 6) nalog output Voltage output Current output Hysteresis External input Display method Indicator light Power supply voltage Current consumption Enclosure Operating temperature range Environment Operating humidity range Withstand voltage Note 7) Insulation resistance Standards and regulations Wetted parts material Note 8) Piping port size Without temperature sensor/without flow adjustment valve With temperature sensor/without flow adjustment valve Without temperature sensor/with flow adjustment valve With temperature sensor/with flow adjustment valve With lead wire with connector Weight Note ) Refer to Measurable Range for Ethylene Glycol queous Solution on page 6. Measurement can be performed with a fluid that does not corrode wetted parts and has viscosity of 3 mpa s [3 cp] or less. e aware that water leakage may happen due to internal seal shrinkage or swelling depending on kinds of fluid. Note ) When.5 s is selected for the response time of the switch output, the repeatability becomes 3% F.S. Note 3) Operating pressure range and proof pressure change according to the fluid temperature. Refer to page 4. Note 4) Cleared by turning off the power supply. It is possible to select the function to memorize it. (Every or 5 minutes) When 5 minutes memorizing is selected, the lifetime of the memory element (electronic part) is million times (5 minutes x million times = 5 million minutes = pprox. 9.5 years for 4 hour energizing). Calculate the lifetime based on your operating conditions before using the memorizing function, and do not exceed it. Note 5) The response time when the set value is 9% in relation to the step input. (The response time is 7 s when it is output by the temperature sensor.) Note 6) The response time until the set value reaches 9% in relation to the step input. (The response time is 7 s when it is analog output by the temperature sensor.) Note 7) When the temperature sensor is used, it will be 5 VC. Note 8) Refer to Wetted Parts Construction on page 6 for details. Note 9) External scratch marks and dirt are judged as good parts provided that they do not affect product performance. Temperature Sensor Specifications Rated temperature range Setting/Display temperature range Minimum setting unit Display unit Display accuracy nalog output accuracy Response time mbient temperature characteristics Note ) The rated temperature range is for the temperature sensor alone. The fluid temperature range specification of the flow switch as a whole is to 9C. Note ) The response time is for the temperature sensor alone. y. L y.5 L y L or open collector output 8 m 8 VDC : V or less (at 8 m load current) :.5 V or less (at 8 m load current).5 s/ s/ s Short circuit protection Select from hysteresis mode, window comparator mode, accumulated output mode, or accumulated pulse output mode. Select from hysteresis mode or window comparator mode..5 s/ s/ s (linked with the switch output) Voltage output: to 5 V Output impedance: k Output current: 4 to m Max. load impedance: 3 for VDC, 6 for 4 VDC Variable Voltage free input:.4 V or less (Reed or Solid state), input for 3 ms or longer -screen display (Main screen: 4-digit, 7-segment, -color, Red/Green Sub screen: 6-digit, -segment, White) Display values updated 5 times per second Output, Output : Orange to 4 VDC % 5 m or less IP65 to 5 C (with no freezing and condensation) Operation, Storage: 35 to 85% R.H. (with no condensation) VC for minute between terminals and housing 5 M or more (5 VDC measured via megohmmeter) between terminals and housing CE marking, UL (CS), RoHS PPS, Stainless steel 34, FKM, SCS3 Non-grease 3/8 g 85 g 3 g 385 g 99999999.9 L 999999999 L to C Note ) to C C C C 3% F.S. 7 s Note ) 5% F.S. 3/8, / 6 g 335 g 36 g 435 g /, 3/4 4 g 53 g 6 g 73 g +85 g 3/4, 7 g 86 g The output related to the temperature sensor is OUT only. Flow rate detecting circuit Temperature detecting circuit Main circuit OUT Switch output OUT Switch output nalog output /4, / 89 g 75 g rown DC (+) lack OUT White OUT lue DC ( ) The OUT can be selected from the output for temperature or flow rate by button operation. 3-Color Display Digital Flow Switch for Water 3-Color Display Digital Flow Switch for PVC Piping 3-Color Display Digital Flow Monitor for Water 3 Function Details

Series Refer to Handling Precautions for SMC Products for Flow Switch Precautions and the Operation Manual in our website for Specific Product Precautions. Specifications (Remote Sensor Unit) Refer to page 8 for monitor unit specifications. Model 54 5 54 5 5 pplicable fluid Detection method Water and ethylene glycol aqueous solution (with viscosity of 3 mpa s [3 cp] or less) Note ) Karman vortex Rated flow range.5 to 4 L/min to 6 L/min 5 to 4 L/min to L/min 5 to 5 L/min Fluid temperature ccuracy Repeatability Temperature characteristics to 9C (with no freezing and condensation) 3% F.S. % F.S. 5% F.S. (5C reference) Operating pressure range Note ) Proof pressure Note ) Pressure loss (without flow adjustment valve) Response time Note 3) nalog output Voltage output Current output Indicator light Power supply voltage Current consumption Enclosure Operating temperature range Environment Operating humidity range Withstand voltage Note 4) Insulation resistance Standards and regulations Wetted parts material Note 5) Piping port size Without temperature sensor/without flow adjustment valve With temperature sensor/without flow adjustment valve Without temperature sensor/with flow adjustment valve With temperature sensor/with flow adjustment valve With lead wire with connector Weight Temperature Sensor Specifications to MPa Note ).5 MPa 45 kpa or less at the maximum flow 6 kpa or less at the maximum flow s Voltage output: to 5 V Output impedance: k Output current: 4 to m Max. load impedance: 3 for VDC, 6 for 4 VDC For power supply status, flow rate indicator (linking speed changes in response to flow rate), and other error indicator to 4 VDC % 3 m or less IP65 to 5C (with no freezing and condensation) Operation, Storage: 35 to 85% R.H. (with no condensation) VC for minute between terminals and housing 5 M or more (5 VDC measured via megohmmeter) between terminals and housing CE marking, UL (CS), RoHS PPS, Stainless steel 34, FKM, SCS3 Non-grease 3/8 95 g 7 g 95 g 37 g 3/8, / 45 g 3 g 345 g 45 g /, 3/4 395 g 55 g 595 g 75 g +85 g 3/4, 75 g 84 g /4, / 875 g 6 g Note ) Refer to Measurable Range for Ethylene Glycol queous Solution on page 6. Measurement can be performed with a fluid that does not corrode wetted parts and has viscosity of 3 mpa s [3 cp] or less. e aware that water leakage may happen due to internal seal shrinkage or swelling depending on kinds of fluid. Note ) Operating pressure range and proof pressure change according to the fluid temperature. Refer to the graphs below. Note 3) The response time until the set value reaches 9% in relation to the step input. (The response time is 7 s when it is analog output by the temperature sensor.) Note 4) When the temperature sensor is used, it will be 5 VC. Note 5) Refer to Wetted Parts Construction on page 6 for details. Note 6) External scratch marks and dirt are judged as good parts provided that they do not affect product performance. Rated temperature range nalog output accuracy Response time mbient temperature characteristics to C Note ) 3% F.S. 7 s Note ) 5% F.S. Note ) The rated temperature range is for the temperature sensor alone. The fluid temperature range specification of the flow switch as a whole is to 9C. Note ) The response time is for the temperature sensor alone. Caution Sensor 74 54 7 5 74 54 7 5 7 5 Set Flow Range and Rated Flow Range Set the flow within the rated flow range. The set flow range is the range of flow rate that is possible in setting. The rated flow range is the range that satisfies the sensor s specifications (accuracy etc.). lthough it is possible to set a value outside the rated flow range, the specifications will not be guaranteed even if the value stays within the set flow range. Flow range.5 L/min L/min 5 L/min L/min 4 L/min L/min 4 L/min 5 L/min 35 L/min.5 L/min.35 L/min.35 L/min L/min.7 L/min.7 L/min 5 L/min 3.5 L/min 3.5 L/min 4 L/min 5.5 L/min 5.5 L/min L/min 7 L/min 7 L/min L/min L/min L/min L/min 6 L/min L/min L/min 5 L/min 5 L/min 4 L/min 55 L/min 55 L/min L/min 4 L/min 4 L/min 5 L/min 5 L/min 8 L/min 8 L/min 35 L/min 35 L/min In the case of the 5 series, the displayable and settable ranges are the same as the 3 series flow monitor. 3 Rated flow range Display flow range Set flow range

3-color display Digital Flow Switch for Water Series nalog Output Flow rate/nalog output Voltage output Current output V 4 m Model.5 V 6 m 74/54 7/5 74/54 7/5 7/5 4/6/4 5.4 V 5.6 m C.8 V 5 V 7. m m Rated flow [L/min] Minimum Maximum.5 4 6 5 4 5 5 Output C Minimum rated flow Operating Pressure and Proof Pressure MaximumFlow rate rated flow Fluid temperature/nalog output 7/5 Output Voltage output Current output Voltage output Current output.6 V.4 m C 5 V m V 4 m D 5.4 V.6 m D C C C C C Fluid temperature 3-Color Display Digital Flow Switch for Water 74/7/74/54/5/54 Pressure [MPa] 7/5 Pressure [MPa].6.4. Proof pressure [MPa].8.6 Operating pressure [MPa].4. 5 9 Fluid temperature [C].6.4. Proof pressure [MPa].8.6 Operating pressure [MPa].4. 3 4 5 6 7 8 9 Fluid temperature [C] 74S/7S/74S/54S/5S/54S Pressure [MPa].6.4..8.6.4. 4 6 8 9 7/5 Pressure [MPa]...8.6.4. Proof pressure [MPa] Operating pressure [MPa] Fluid temperature [C] Operating pressure/ Proof pressure [MPa] 3 4 5 6 7 8 9 Fluid temperature [C] 3-Color Display Digital Flow Switch for PVC Piping 3-Color Display Digital Flow Monitor for Water 3 Function Details 4

Series Flow-rate Characteristics (Pressure Loss: Without Flow djustment Valve) 74/54 7/5 74/54.4.4.4 Pressure loss [MPa].3.. Pressure loss [MPa].3.. Pressure loss [MPa].3..... 3. 4. Flow rate [L/min] 7/5 4 6 8 4 6 Flow rate [L/min] 7/5 5 5 5 3 35 4 Flow rate [L/min].4.5 Pressure loss [MPa].3.. Pressure loss [MPa].4.3.. 4 6 8 5 5 5 Flow rate [L/min] Flow rate [L/min] Straight Piping Length and ccuracy (Reference Value) Straight piping length The smaller the piping size, the more the product is affected by the straight piping length. Fluid pressure has almost no affect. Low flow rate lessens the effect of the straight piping length. Use a straight pipe that is 8 cm or longer in length to satisfy the 3% F.S. specification. ( cm or longer for L/min and 5 L/min types) Pressure:.3 MPa Pressure:.3 MPa 74/54 Piping diameter: ø 7/5 Piping diameter: ø 74/54 ccuracy [% F.S.] 9 8 7 6 5 74/54-3 (at 4 L /min) 4 3 4 6 8 Straight piping length [cm] Pressure:.3 MPa Piping diameter: 5 (Port size ) 7/5 (Port size 6) ccuracy [% F.S.] 6 4 8 6 4 7/5-6 (at 5 L /min) 7/5-6 (at L /min) 7/5- (at L /min) 7/5- (at 5 L /min) ccuracy [% F.S.] Pressure:.3 MPa Piping diameter: 3 (Port size ) 7/5 4 (Port size 4) ccuracy [% F.S.] 9 8 7 6 5 4 3 9 8 7 6 5 4 3 7/5-3 (at 6 L /min) 7/5-4 (at 6 L /min) 7/5-3 (at 8 L /min) 4 6 8 Straight piping length [cm] 7/5-4 (at 5 L /min) 7/5- (at 5 L /min) ccuracy [% F.S.] Pressure:.3 MPa Piping diameter: ø6 9 8 7 6 5 74/54-4 (at 4 L /min) 4 3 74/54-6 (at 4 L /min) 4 6 8 Straight piping length [cm] 4 6 8 Straight piping length [cm] No data for 4 cm, or for under 5 cm, as these cannot be used due to piping dimensions. 5 4 6 8 Straight piping length [cm]

3-color display Digital Flow Switch for Water Series Flow-rate Characteristics of Flow djustment Valve 74S/54S 7S/5S 74S/54S Flow rate [L/min] 6. 4.. P =.4 MPa P =.3 MPa P =. MPa P =. MPa P =.5 MPa 4 5 Number of rotations [rotations] P: Pressure differential between the front and the rear of product Measurable Range for Ethylene Glycol queous Solution (Reference Value) Flow rate [L/min]. 5.. P =.3 MPa 5. P =.5 MPa P =.4 MPa P =. MPa P =. MPa 4 5 Number of rotations [rotations] P: Pressure differential between the front and the rear of product Flow rate [L/min] 6 5 4 3 P =.5 MPa P =.4 MPa P =.3 MPa P =. MPa P =. MPa 3 4 5 6 7 8 Number of rotations [rotations] P: Pressure differential between the front and the rear of product 3-Color Display Digital Flow Switch for Water queous solution concentration [%] (Weight) 9 8 7 6 5 4 3 Measurable within this range 3 4 5 6 7 8 9 queous solution temperature [C] Wetted Parts Construction Component Parts No. Description 3 4 5 6 7 8 9 ttachment Seal ody Sensor q r w w Temperature sensor Temperature sensor body Flow adjustment valve body Flow adjustment valve cover Flow adjustment valve shaft Shaft support Y seal Cap seal e y Material SCS3 Stainless steel 34 FKM PPS PPS Stainless steel 34 Stainless steel 34 PPS PPS Stainless steel 34 PPS FKM FKM o i t w u!! w! w Note Stainless steel 34 equivalent 74/7/74/7/54/5/54/5 7/5 With brazing JIS Z 36: g-7, ( ISO 3677: -g56cuznsn-6/65 ) 6 3-Color Display Digital Flow Switch for PVC Piping 3-Color Display Digital Flow Monitor for Water 3 Function Details

Series Dimensions 74/7/74/7/7 Integrated display Connector pin number Example 3 4 For 7 Pin no. 3 4 Pin name DC (+) OUT DC ( ) OUT G Z Y D.4 E F x Piping port 3 5 S (35.5) H J T U 4 4 x WX V W IN OUT G K L 4 x P G x Piping port N 54/5/54/5/5 Remote sensor unit Y F DD E J 3 V W G Z x Piping port S T U 4 x WX For 5 (35.5) H 4 IN OUT G K L 4 x P G x Piping port N Model 74/54 7/5 74/54 7/5 7 7/5 Port size (Rc, NPT, G) 3/8 3/8, / /, 3/4 3/4, /4, / G /4 G / 7 78 98 4 4 8 5 54 7 9 74 76 78 3 3 38 46 56 D 6 6 68 77 9 DD 45.6 45.6 53.6 6.6 76.6 E 4.6 4.6 48.6 57.6 7.6 F 5. 5. 9. 3. 8.5 G 4 7 3 4 54 H 4 8 8 4 3 33 35 J 35 39 49 63 5 54 56 K 6 3 35 48 39.5 4.5 43.5 L 8 8 8 8 5 N 3.6 3.6 6.8 8. 7.5 P ø.7 depth 4 ø.7 depth ø.7 depth ø3.5 depth 4 ø3.5 depth 4 S 4 8 34 44 T 3 36 racket dimensions U 3 3 4 48 V 4 4 48 58 W 5 5 58 7 WX 4.5 4.5 4.5 5.5 Y 5 5 5 7 (mm) Z.5.5.5.

3-color display Digital Flow Switch for Water Series Dimensions 74/7/74/7--T Integrated display: With temperature sensor Model 74/54--T 7/5--T 74/54--T 7/5--T 7/5--T 7/5-F-T 7/5-F4-T 8 89 9 35 5 9 3 D S (mm) 74S/7S/74S Integrated display: With flow adjustment valve 5 54 7 9 74 76 78 T 54/5/54/5--T Remote sensor unit: With temperature sensor D S 54S/5S/54S Remote sensor unit: With flow adjustment valve T 3-Color Display Digital Flow Switch for Water 3-Color Display Digital Flow Switch for PVC Piping Q Q K F L 4 x P N K F L 4 x P N 3-Color Display Digital Flow Monitor for Water 3 (mm) Model 74S/54S 7S/5S 74S/54S 4 4 5 54 7 63.6 (Max. 68.6) 63.6 (Max. 68.6) 75.5 (Max. 8) D 7. 74. 94.5 F 34 34 44 K 58.5 6.5 79. L 8 8 8 N 3.6 3.6 6.8 P ø.7 depth ø.7 depth ø.7 depth Q ø9 ø9 ø8 Q number of rotations 6 6 7 racket dimensions S T 56.5 6.5 78. 3 8 Function Details

Series Dimensions 74S/7S/74S--T Integrated display: With temperature sensor and flow adjustment valve 54S/5S/54S--T Remote sensor unit: With temperature sensor and flow adjustment valve S D S D K K (mm) Model D K S 74S/54S--T 7S/5S--T 74S/54S--T 5 3 53 5 54 7 8. 85. 5.5 69.5 73.5 9. 67.5 7.5 89. ZS-4- Lead wire with M8 connector (lack) 4 (lue) 3 M8 (White) (rown) Pin no. Pin name Wire color 3 4 DC (+) OUT DC ( ) OUT rown White lue lack ø (3.8) ø4 (3) (45) (5) Lead Wire Specifications Conductor Insulator Sheath Finished O.D. Note ) 4-wire type lead wire with M8 connector used for the series. Note ) Refer to the Operation Manual in our website (http://www.smcworld.com) for wiring. Nominal cross section O.D. Material O.D. Color Material WG3 pprox..7 mm Heat resistant PVC pprox.. mm rown, White, lack, lue Heat and oil resistant PVC ø4 9

Series Made to Order Please consult SMC for detailed dimensions, specifications and delivery. Made to Order Seal material EPDM Seal material for wetted parts changed to EPDM 5 7 Refer to How to Order, page for details. Note) Not compatible with units with flow adjustment valve. Please special-order separately. X9 X9 Seal material EPDM Symbol -X9 3-Color Display Digital Flow Switch for Water nalog 4 to m output Output specification of remote type with a temperature sensor: nalog 4 to m output 5 X8 nalog 4 to m output Refer to How to Order, page for details. Note) Remote monitor unit is eguipped as standard. 3 Piping material brass Piping (attachment) material changed to brass Symbol -X8 Symbol -X43 3-Color Display Digital Flow Switch for PVC Piping 5 X43 7 Refer to How to Order, page for details. Note) Not compatible with units with flow adjustment valve. Please special-order separately. Surface treatment is not applied on piping. X43 Piping (attachment) material brass Piping (attachment) Function Details 3-Color Display Digital Flow Monitor for Water 3

For how to order of remote monitor unit, refer to page 8. Remote sensor unit Integrated display Options/Part No. 3-color display Digital Flow Switch for PVC Piping Series How to Order racket (Option) Nil R Lead wire Nil When optional parts are required separately, use the following part numbers to place an order. Description racket Lead wire with M8 connector 5 7 Symbol Remote sensor unit Output specification 5 U 7 U 5 M Type Remote sensor unit Integrated display Rated flow range (Flow range) Symbol Rated flow range to L/min 3 to 5 L/min Symbol 5 3 Part no. ZS-4-M ZS-4- OUT nalog to 5 V nalog 4 to m To use in combination with remote monitor (3 series), select analog output of to 5 V of flow rate (output symbol - ). Port size 5 3 Connection type U PVC pipe PVC pipe O.D. Rated flow range Pipe O.D. 3 mm 38 mm JIS K674 equivalent Symbol OUT OUT C D E F G H nalog to 5 V nalog 4 to m nalog to 5 V nalog 4 to m External input External input External input: The accumulated value, peak value, and bottom value can be reset. Qty. Remote sensor unit/unit printed on label Symbol Instantaneous flow rate Temperature Nil L/min C L/min G C/F (gal/min) Under the New Measurement Law, units other than SI (symbol Nil ) cannot be used in Japan. Note) G: Made to Order Reference: [L/min].64 [gal/min] [gal/min] 3.785 [L/min] F = 9/5C + 3 Integrated display Output specification None racket With lead wire with M8 connector (3 m) Note For 7/5 With 4 tapping screws (4 x ) Lead wire length (3 m) Calibration certificate (Only flow sensor) Integrated display/unit specification Symbol M G F J Instantaneous flow rate L/min gal/min gal/min L/min Nil None With calibration certificate The certificate is written in both English and Japanese. ccumulated flow L gal gal L Under the New Measurement Law, units other than SI (symbol M ) cannot be used in Japan. Note) G, F, J: Made to Order Reference: [L/min].64 [gal/min] [gal/min] 3.785 [L/min] F = 9/5C + 3 Made to Order X9 Seal material EPDM (Refer to page 7.) N Note) With bracket is not available for 5 L/min type. Temperature C C F F Without lead wire with M8 connector RoHS

3-color display Digital Flow Switch for PVC Piping Series Specifications (Integrated Display) Refer to Handling Precautions for SMC Products for Flow Switch Precautions and the Operation Manual in our website for Specific Product Precautions. Model pplicable fluid Detection method Rated flow range Display flow range Set flow range Minimum setting unit Conversion of accumulated pulse Fluid temperature Display unit ccuracy Repeatability Temperature characteristics Operating pressure range Note 3) Proof pressure Note 3) Pressure loss ccumulated flow range Note 4) Switch output Response time Note ), 5) Output protection Output mode Flow rate Response time Note 6) nalog output Voltage output Current output Hysteresis External input Display method Indicator light Power supply voltage Current consumption Wetted parts material Note 7) Piping port size Weight Maximum load current Maximum applied voltage Internal voltage drop Enclosure Operating temperature range Environment Operating humidity range Withstand voltage Insulation resistance Standards and regulations Without lead wire with connector With lead wire with connector 7 7 Water and ethylene glycol aqueous solution (with viscosity of 3 mpa s [3 cp] or less) Note ) Karman vortex to L/min 3 to 5 L/min 7 to 4 L/min to 35 L/min (Flow under 7 L/min is displayed as ) (Flow under L/min is displayed as ) 7 to 4 L/min to 35 L/min L/min L/min L/pulse L/pulse to 7C (with no freezing and condensation) Instantaneous flow rate: L/min, ccumulated flow: L, Display values updated 5 times per second Display value: 3% F.S. nalog output: 3% F.S. % F.S. Note ) 5% F.S. (5C reference) to MPa MPa 45 kpa or less at the maximum flow 999999999 L y L or open collector output 8 m 8 VDC : V or less (at 8 m load current) :.5 V or less (at 8 m load current).5 s/ s/ s Short circuit protection Select from hysteresis mode, window comparator mode, accumulated output mode, or accumulated pulse output mode..5 s/ s/ s (linked with the switch output) Voltage output: to 5 V Output impedance: k Output current: 4 to m Max. load impedance: 3 for VDC, 6 for 4 VDC Variable Voltage free input:.4 V or less (Reed or Solid state), input for 3 ms or longer -screen display (Main screen: 4-digit, 7-segment, -color, Red/Green Sub screen: 6-digit, -segment, White) Output, Output : Orange to 4 VDC % 5 m or less IP65 to 5 C (with no freezing and condensation) Operation, Storage: 35 to 85% R.H. (with no condensation) VC for minute between terminals and housing 5 M or more (5 VDC measured via megohmmeter) between terminals and housing CE marking, UL (CS), RoHS PPS, FKM, CPVC Non-grease 5 85 g 37 g Note ) Refer to Measurable Range for Ethylene Glycol queous Solution on page 6. Measurement can be performed with a fluid that does not corrode wetted parts and has viscosity of 3 mpa s [3 cp] or less. Refer to the list of applicable fluids on page 4. Note ) When.5 s is selected for the response time of the switch output, the repeatability becomes 3% F.S. Note 3) Operating pressure range and proof pressure change according to the fluid temperature. Refer to the graph below. Note 4) Cleared by turning off the power supply. It is possible to select the function to memorize it. (Every or 5 minutes) When 5 minutes memorizing is selected, the lifetime of the memory element (electronic part) is million times (5 minutes x million times = 5 million minutes = pprox. 9.5 years for 4 hour energizing). Calculate the lifetime based on your operating conditions before using the memorizing function, and do not exceed it. Note 5) The response time when the set value is 9% in relation to the step input. Note 6) The response time until the set value reaches 9% in relation to the step input. Note 7) Refer to Wetted Parts Construction on page 4 for details. nalog Output Flow rate/nalog output Voltage output Current output Model V 4 m 7/5 7/5.4 V.5 V C 5 V 5.6 m 5.9 m m Rated flow [L/min] Minimum 3 Maximum 5 Output C Minimum rated flow Maximum Flow rate rated flow 3 34 g 45 g Operating Pressure/Proof Pressure 7/7/5/5 (for PVC Piping) Max. operating pressure [MPa]..8.6.4. 3 4 5 Fluid temperature [C] 6 7 8 9 3-Color Display Digital Flow Switch for Water 3-Color Display Digital Flow Switch for PVC Piping 3-Color Display Digital Flow Monitor for Water 3 Function Details

Series Refer to Handling Precautions for SMC Products for Flow Switch Precautions and the Operation Manual in our website for Specific Product Precautions. Specifications (Remote Sensor Unit) Refer to page 9 for monitor unit specifications. Model pplicable fluid Detection method Rated flow range Fluid temperature ccuracy Repeatability Temperature characteristics Operating pressure range Note ) Proof pressure Note ) Pressure loss Response time Note 3) nalog output Voltage output Current output Indicator light Power supply voltage Current consumption Enclosure Operating temperature range Environment Operating humidity range Withstand voltage Insulation resistance Standards and regulations Wetted parts material Note 4) Piping port size Weight Without lead wire with connector With lead wire with connector 5 5 Water and ethylene glycol aqueous solution (with viscosity of 3 mpa s [3 cp] or less) Note ) Karman vortex to L/min 3 to 5 L/min to 7C (with no freezing and condensation) 3% F.S. % F.S. 5% F.S. (5C reference) to MPa Note ) MPa 45 kpa or less at the maximum flow s Voltage output: to 5 V Output impedance: k Output current: 4 to m Max. load impedance: 3 for VDC, 6 for 4 VDC For power supply status, flow rate indicator (linking speed changes in response to flow rate), and other error indicator to 4 VDC % 3 m or less IP65 to 5C (with no freezing and condensation) Operation, Storage: 35 to 85% R.H. (with no condensation) VC for minute between terminals and housing 5 M or more (5 VDC measured via megohmmeter) between terminals and housing CE marking, UL (CS), RoHS PPS, FKM, CPVC Non-grease 5 3 7 g 35 g 355 g 4 g Note ) Refer to Measurable Range for Ethylene Glycol queous Solution on page 6. Measurement can be performed with a fluid that does not corrode wetted parts and has viscosity of 3 mpa s [3 cp] or less. Refer to the list of applicable fluids on page 4. Note ) Operating pressure range and proof pressure change according to the fluid temperature. Refer to the graphs below. Note 3) The response time until the set value reaches 9% in relation to the step input. Note 4) Refer to Wetted Parts Construction on page 4 for details. Flow-rate Characteristics (Pressure Loss) 7/5 7/5.4.4 Pressure loss [MPa].3.. Pressure loss [MPa].3.. 4 6 8 Flow rate [L/min] 5 5 5 Flow rate [L/min] Straight Piping Length and ccuracy (Reference Value) Straight piping length 7/7/5/5 Pressure:.3 MPa Piping diameter: 5, 3 Fluid pressure has almost no effect. To maintain 3% F.S. in the specificatioins, use a straight pipe that is cm or longer in length. ccuracy [% F.S.] 8 6 4 7/5-U5 7/5-U3 (at L/min) (at 5 L/min) 4 6 8 Straight piping length [cm] 3 For measurable range for ethylene glycol aqueous solution (reference values), refer to page 6.

3-color display Digital Flow Switch for PVC Piping Series Wetted Parts Construction q t w e r w t 3-Color Display Digital Flow Switch for Water Component Parts No. Description PVC pipe Seal 3 ody 4 Sensor Material CPVC FKM PPS PPS Note Replacement Parts No. Description PVC pipe (5) PVC pipe (3) 5 5 retaining plate (M5 x 8 with two hexagonal socket head cap screws) 3 retaining plate (M5 x 65 with two hexagonal socket head cap screws) Part no. ZS-4-U5 ZS-4-U3 ZS-4-U5- ZS-4-U3- Replacing the PVC pipe may cause accuracy to fluctuate by to %. Qty. Function Details 3-Color Display Digital Flow Switch for PVC Piping 3-Color Display Digital Flow Monitor for Water 3 4

Series Dimensions 7-U5 Integrated display 7 3 57.6 77.4 77 54 x 5 IN (35.5) OUT 63 8 8 ø3 46 3 58 7 59 36 4 x 5.5 48 57 4 Example 3 4 Connector pin number Pin no. 3 4 Pin name DC (+) OUT DC ( ) OUT 4 x 3.5 depth 4 5-U5 Remote sensor unit 6.6 IN OUT ZS-4- Lead wire with M8 connector (lack) 4 (lue) 3 M8 (White) (rown) Pin no. Pin name Wire color 3 4 DC (+) OUT DC ( ) OUT rown White lue lack 5 ø (3.8) ø4 (3) (45) (5) Lead Wire Specifications Conductor Insulator Sheath Finished O.D. Note ) 4-wire type lead wire with M8 connector used for the series. Note ) Refer to the Operation Manual in our website (http://www.smcworld.com) for wiring. Nominal cross section O.D. Material O.D. Color Material WG3 pprox..7 mm Heat resistant PVC pprox.. mm rown, White, lack, lue Heat and oil resistant PVC ø4

3-color display Digital Flow Switch for PVC Piping Series Dimensions 7-U3 Integrated display ody side Connector pin number 8.5 9 76.6 7.6 x 3.4 56 3 (35.5) 46 5 4 3-Color Display Digital Flow Switch for Water Pin no. Pin name 3 4 3 4 DC (+) OUT DC ( ) OUT 7.5 Flow direction 5 4 x 3.5 depth 4 ø38 3-Color Display Digital Flow Switch for PVC Piping 5-U3 Remote sensor unit ody side Connector pin number 8.5 76.6 7.6 x 3 56 3 46 5 4 (35.5) 3-Color Display Digital Flow Monitor for Water 3 Pin no. Pin name 3 4 3 4 DC (+) Not used DC ( ) OUT Flow direction Function Details 6

Series Made to Order Please consult SMC for detailed dimensions,specifications and delivery. Made to Order Seal material EPDM Seal material for wetted parts changed to EPDM Symbol -X9 5 7 U U X9 X9 Seal material EPDM Refer to How to Order, page for details. 7

Digital Flow Monitor for Water Series 3 3 3 Type Remote monitor unit For remote sensor units, select the analog output to 5 V type. pplicable sensors: 5--(T) Output specification Symbol OUT OUT C D E F G H nalog to 5 V nalog 4 to m nalog to 5 V nalog 4 to m External input External input J K nalog to 5 V nalog 4 to m nalog to 5 V nalog 4 to m In combination with remote sensor unit with temperature sensor, only OUT can be set for temperature sensor output. Lead wire Nil With power supply/output connection lead wire ( m) Power supply/output connection lead wire ZS-4-W N Without power supply/output connection lead wire Lead wire is not connected, but shipped together. Options/Part No. 3-color display How to Order Remote monitor unit/unit specification Symbol Instantaneous flow rate ccumulated flow Temperature M G F J L/min gal/min gal/min L/min L gal gal L C C F F Under the New Measurement Law, units other than SI (symbol M ) cannot be used in Japan. Note) G, F, J: Made to Order Reference: [L/min].64 [gal/min] [gal/min] 3.785 [L/min] F = 9/5C + 3 Calibration certificate (Only flow monitor) Nil None With calibration certificate The certificate is written in both English and Japanese. Option Nil C None Sensor connector ( pc.) Sensor connector (e-con) Connector is not connected, but shipped together. Option Nil When optional parts are required separately, use the following part numbers to place an order. Description Part no. Panel mount adapter ZS-6- Front protective cover + Panel mount adapter ZS-6-C Front protective cover only ZS-6- Power supply/output connection lead wire ZS-4-W Sensor connector (e-con) ZS-8-C-4 Lead wire with connector for copying ZS-4-Y M V C T V Waterproof seal (accessory) None Panel mount adapter Panel Panel mount adapter Mounting screw (M3 x 8 L) (accessory) Front protective cover + Panel mount adapter Front protective cover Panel mount adapter Mounting screw (M3 x 8 L) (accessory) Waterproof seal (accessory) Panel Note With waterproof seal and screws With waterproof seal and screws Separately order panel mount adapter etc. Lead wire length ( m) pc. Connect up to slave units RoHS 8 3-Color Display Digital Flow Switch for Water 3-Color Display Digital Flow Switch for PVC Piping 3-Color Display Digital Flow Monitor for Water 3 Function Details

Series 3 Specifications Refer to Handling Precautions for SMC Products for Flow Switch Precautions and the Operation Manual in our website for Specific Product Precautions. Model Display flow range Set flow range Minimum setting unit Conversion of accumulated pulse Display unit ccuracy Repeatability Temperature characteristics ccumulated flow range Note ) Switch output Output Flow rate mode Temperature Response time Note 3) nalog output Voltage output Current output Hysteresis External input Input/output Display method Indicator light Power supply voltage Current consumption Connection Weight Maximum load current Maximum applied voltage Internal voltage drop Response time Note ) Output protection Enclosure Operating temperature range Environment Operating humidity range Withstand voltage Insulation resistance Standards and regulations Without power supply/output connection lead wire With power supply/output connection lead wire 3.35 to 4.5 L/min.7 to 8. L/min 3.5 to 45. L/min 7 to L/min to 8 L/min (Flow under.35 L/min is displayed as. ) (Flow under.7 L/min is displayed as. ) (Flow under 3.5 L/min is displayed as. ) (Flow under 7 L/min is displayed as ) (Flow under L/min is displayed as ).35 to 4.5 L/min.7 to 8. L/min 3.5 to 45. L/min 7 to L/min to 8 L/min. L/min. L/min L/min L/min.5 L/pulse. L/pulse.5 L/pulse L/pulse L/pulse Instantaneous flow rate: L/min, ccumulated flow: L Display value: ±.5% F.S. nalog output: ±.5% F.S. ±.5% F.S. ±.5% F.S. (5C reference) 99999999.9 L 999999999 L y. L y.5 L y L or open collector output 8 m 8 VDC : V or less (at 8 m load current) :.5 V or less (at 8 m load current) s/ s Short circuit protection Select from hysteresis mode, window comparator mode, accumulated output mode, or accumulated pulse output mode. Select from hysteresis mode or window comparator mode. s/ s (linked with the switch output) Voltage output: to 5 V Output impedance: k Output current: 4 to m Max. load impedance: 3 for VDC, 6 for 4 VDC Variable Voltage free input:.4 V or less (Reed or Solid state), input for 3 ms or longer Input for copy mode -screen display (Main screen: 4-digit, 7-segment, -color, Red/Green Sub screen: 6-digit, -segment, White), Display values updated 5 times per second Output, Output : Orange to 4 VDC % 5 m or less Power supply output 5P connector, sensor connection 4P connector (e-con) IP4 (Only front face of the panel is IP65 when panel mount adapter and waterproof seal of optional parts are used.) to 5C (with no freezing and condensation) Operation, Storage: 35 to 85% R.H. (with no condensation) VC for minute between terminals and housing 5 M or more (5 VDC measured via megohmmeter) between terminals and housing CE marking, UL (CS), RoHS 5 g g Note ) Cleared by turning off the power supply. It is possible to select the function to memorize it. (Every or 5 minutes) When 5 minutes memorizing is selected, the lifetime of the memory element (electronic part) is million times (5 minutes x million times = 5 million minutes = pprox. 9.5 years for 4 hour energizing). Calculate the lifetime based on your operating conditions before using the memorizing function, and do not exceed it. Note ) The response time when the set value is 9% in relation to the step input. (The response time is 7 s when it is output by the temperature sensor.) Note 3) The response time until the set value reaches 9% in relation to the step input. (The response time is 7 s when it is analog output by the temperature sensor.) Temperature Sensor Specifications Rated temperature range Setting/Display temperature range Minimum setting unit Display unit nalog output accuracy Response time mbient temperature characteristics 5% F.S. Note ) The rated temperature range is for the temperature sensor alone. The fluid temperature range specification of the flow switch as a whole is to 9C. Note ) The response time is for the temperature sensor alone. nalog Output Flow rate/nalog output C Output 4//4 C Voltage output V.5 V.4 V.5 V 5 V Current output 4 m 6 m 5.6 m 5.9 m m The values of vary according to the range. Model 54 5 54 5 5 9 Flow rate [L/min] Minimum Maximum.5 4 6 5 4 3 5 Minimum flow to C Note ) to C C C 3% F.S. 7 s Note ) Maximum Flow rate flow DC (+) rown Flow rate Remote to 5 V lack sensor Temperature to 5 V White unit DC ( ) lue The output related to the temperature sensor is OUT only. The OUT can be selected from the output for temperature or flow rate by button operation. Fluid temperature/nalog output Voltage output.6 V Current output.4 m V 4 m C D Voltage output 5 V 5.4 V Current output m.6 m e sure to use in combination with remote sensor unit with temperature sensor. Main circuit Output D C C Remote monitor unit C OUT Switch output nalog output OUT Switch output nalog output rown DC (+) lack OUT White OUT lue DC ( ) C C Fluid temperature

3-color display Digital Flow Switch for Water Series 3 Dimensions 4 Front protective cover + Panel mount adapter 4 53 47 6 9.4 () 4. (7.5).5 36.8 NC/IN Sensor connector (4P) Power supply/ output connector (5P) 3-Color Display Digital Flow Switch for Water Panel fitting dimmensions pplicable panel thickness:.5 to 8 mm (Without waterproof seal).5 to 6 mm (With waterproof seal) 55 or more +. 37.5. 46.4 4.4 Front protective cover Waterproof seal 37.5 +.. 4 x R or less Panel 48 or more Panel mount adapter 3-Color Display Digital Flow Switch for PVC Piping Sensor connector q w e r 3 4 Power supply/output connection lead wire Pin no. Gray COPY White OUT 3 lack OUT 4 lue DC ( ) 5 rown DC (+) Pin no. q w e r Terminal DC (+) N.C./IN DC ( ) INPUT Connector no. 3 4 Lead wire color rown White (Not used/temperature sensor to 5 V input) lue lack (Flow rate sensor to 5 V input) When using the lead wire with M8 connector included with the 5 series Lead Wire Specifications Nominal cross section Conductor O.D. Material Insulator O.D. Color Sheath Material Finished O.D. WG6 pprox..5 mm Cross-linked vinyl pprox.. mm rown, lue, lack, White, Gray Oil and heat resistant vinyl ø3.5 3-Color Display Digital Flow Monitor for Water 3 Function Details Note) Refer to the Operation Manual in our website (http://www.smcworld.com) for wiring.

Series Function Details Integrated Display (Series 7)/Remote Monitor Unit (Series 3) Output operation The output operation can be selected from the following: Output (hysteresis mode and window comparator mode) corresponding to instantaneous flow rate, Output corresponding to accumulated flow, ccumulated pulse output Note) t the time of shipment from the factory, it is set to hysteresis mode and normal output. When a temperature sensor is attached, the output to the temperature sensor is selectable only for OUT. (Refer to How to Order for details.) Indication color The indication color can be selected for each output condition. The selection of the indication color provides visual identification of abnormal values. (The indication color depends on OUT setting.) ON: Green, OFF: Red ON: Red, OFF: Green lways: Red lways: Green Response time The response time can be selected depending on the application. ( second for default setting) bnormalities can be detected more quickly by setting the response time to.5 seconds. The effect of the pump fluctuation and flickering of the display can be reduced by setting the response time to seconds. Note) The temperature sensor output is fixed to 7 seconds. Response time.5 seconds second seconds pplicable model Integrated display Remote monitor unit Series 7 Series 3 Selection of display on sub screen The display on the sub screen in measuring mode can be set. External input function This function can be used when external input is available. The accumulated value, peak value, and bottom value can be reset by remote control. ccumulated flow external reset: This function resets the accumulated value to when an input signal is applied. In accumulated increment mode, the value will be zero when reset, and the accumulated value will increase from zero. In accumulated decrement mode, the value will be the set value when reset, and the accumulated value will decrease from the set value. When the accumulated value is memorized, every time the accumulated value external reset is activated, the memory element (EEPROM) will be accessed. Take into consideration the maximum number of times the memory element can be accessed, million times. The total of external input times and accumulated value memorizing time interval should not exceed million times. Peak and bottom reset: Peak and bottom values are reset. Forced output function Output is turned ON/OFF compulsorily when starting the system or during maintenance. This enables confirmation of the wiring and prevents system errors due to unexpected output. For the analog output type, the output will be 5 V or m for ON and V or 4 m for OFF. lso, the increase or decrease of the flow and temperature will not change the on/off status of the output while the forced output function is activated. ccumulated value hold function ccumulated value can be saved on the unit even when the power supply is turned off. The accumulated value is memorized every or 5 minutes during measurement, and continues from the last memorized value when the power supply is turned on again. The lifetime of the memory element is million access cycles. Take this into consideration before using this function. Sub screen Displays the set value. (The set value of OUT cannot be displayed.) Integrated display Displays the accumulated value. (The accumulated value of OUT cannot be displayed.) Remote monitor unit Set value display ccumulated value display Peak value display ottom value display Displays the peak value. Displays the bottom value. Line name display Displays the line name. (Up to 6 alphanumeric characters can be input.) Fluid temperature display Displays the fluid temperature. (When the temperature sensor type is selected.) OFF Displays nothing. The above are examples of integrated displays. (Same as remote monitor unit) Power saving mode The display can be turned off to reduce the power consumption. In power saving mode, decimal points blink on the main screen. If any button is pressed during power saving mode, the display is recovered for 3 seconds to check the flow, etc. Setting of secret code Users can select whether a secret code must be entered to release key lock. t the time of shipment from the factory, it is set such that the secret code is not required. Peak/ottom value indication The maximum (minimum) flow is detected and updated from when the power supply is turned on. In peak (bottom) value indication mode, this maximum (minimum) flow is displayed. Keylock function Prevents operation errors such as accidentally changing setting values.