Industrial Loadbreak Elbow

Similar documents
3M Cold Shrink Splice Kit QS-III 5514A

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-4/0-500

3M Cold Shrink Splice Kit QS-III 5416A

3M Cold Shrink Splice Kit QS-III 5515A

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-2-4/0

3M Cold Shrink QS4 Integrated Splice Kit QS4-35TS

3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT

Instructions. Cable with Armor F CAUTION. October Rev A

3M Cold Shrink QS-III Splice Kit 5467A(S)-WF

F CAUTION. Jacketed Concentric Neutral (JCN) Cable. Concentric Neutral (CN) Cable. IEEE Std. No. 48 Class 1 Termination 15 kv Class 110 kv BIL

Quick Term II Silicone Rubber Termination Kits for Shielded Cables Instruction Sheet

Quick Term II. Cold Shrink Silicone Rubber Termination (With High-K Stress Relief) Instruction Sheet. Quick Term II. Silicone Rubber Termination Kits

3M Motor Lead Inline Splice 5331, 5332, 5333 & 5334

3M Cold Shrink QS4 Integrated Splice Kit QS4-15SP-2-4/0

Cold Shrink Silicone Rubber Termination QT-II

Cold Shrink Three-Conductor Splice Kit QS-III for use on Armor and Non-Armor Cables Instructions IEEE Std kv Class 250 kv BIL

3M Cold Shrink Rubber Splicing Kit 5552

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit

TFT-150R-G. Tape Shield Cable (page 2) Suggested Installation Equipment (not supplied with kit) Wire Shield Cable (page 7)

3M Cold Shrink Foldback Splice Jacket Kit

3 SLiC Aerial Closure with Rubber End Seal

Quick Term III. 3M Cold Shrink 3 Core Indoor Termination. 3.3 kv mm 2

3M Distribution Box (DDB)

3M Better Buried Closures

Cold Shrink Straight Joint

HSK Mine and Portable Cable Splice

3 Foam Sealed Closure 2" (50 mm) with Compound Compression

COOPER POWER SERIES. 600 A 15/25 kv class DT625 T-body installation and cable preparation instructions. Deadbreak Apparatus Connectors MN650017EN

3M Scotchcast Flexible Power Cable Splice Kits 82-F Series

3M Better Buried Compound Compression Closure System

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

3M Sensored Termination (15 kv) QX-T15I-vi1-E

3M Scotchcast Mine and Portable Cable Splice and Jacket Repair Kit M-40

3M Coupling Tray FDTC-10S-COUPLINGTRAY

3M SLiC 530/533/733-2 Port 0.61 Cable Entry Bracket 3M SLiC 530/533/733-2 Port-MSM 0.61 Cable Entry Bracket

3M Better Buried Closure (with 3M Scotchlok Shield Bond Connector 4462-FN and 3M High Gel Re-enterable Encapsulant 8882)

SLiC Fiber Aerial Closure System

4320 SS-25 Self-Strip Terminating Block

Solutions for Electronic Specialty Markets (ESM)

2178-L/S Series Fiber Optic Splice Case with Gasket

3M Scotchcast Reenterable Signal and Control Cable Splicing Kits 78-R Series

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

K & B Flame Retardant Building Riser Closures

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

18mm ECAM Cable Entry Port

3M Locator Plate N

Scotch Heavy Duty Vinyl Electrical Tape 22

INSTALLATION INSTRUCTION PEM1423ENG ENGLISH

Scotchlok Connectors and Tools

3M Fiber Optic Splice Tray 2527 with 3M PLC Optical Splitter

27mm ECAM Double Cable Entry Port

INSTALLATION INSTRUCTION PEM1368ENG ENGLISH

2178 Fiber Optic Splice Case and 2181 Cable Addition Kit

Communication Markets Division 3M Scotchlok Connectors and Tools. Proven. Solutions for. Today s Applications

Instruction Guide February 2017

Built tough for long-term connections

Built tough for long-term connections

3M Mini D Ribbon (MDR) Cable Assembly

3M Fiber Optic Wall Mount Enclosure 8430 Series

3M Super 23 Electrical Tape

3M 8900 Single-mode SC Crimplok Connector

Student Services & Classroom Addition

VITALink Taped Splice Straight Through Crimp

Cabinet Tools and Accessories Ordering Guide

ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES

LEGEND POWER SYSTEMS

2016 Cable Splicing Courses

3M Fiber Optic Closure System LL

3M No Polish Jacketed SC/APC Connector

STRAIGHT TWO WAY JOINT3/C, PAPER INSULATED, SHIELDED, LEAD COVERED CABLE. Revised: October 10, 2008 Revised By: SGL Approved By: RHS SPLICES

3M No Polish Jacketed SC/APC Connector

TRANSMISSION ENGINEERING STANDARD TES-P , Rev. 0 TABLE OF CONTENTS 1.0 SCOPE 2.0 CABLES SPLICES

Quante BPEO Splice-Protection Closure for Optical Fiber Cables. Features Advantages Benefits

3 Cold Shrink Products

FOSC 450 C6 and D6 Closures

High Density Block BRCP. HD BRCP- 128/192/256 pair. Installation Instructions

OWNER'S MANUAL SIGNAL COMMANDER

Aging test: integrated vs. non-integrated splices shield continuity systems.

Dynatel Advanced Cable Locator 2250

Sections 1. Application Equipment 2. Cable Preparation 3. Assembly 4. Termination Procedure 5. Inspection 6. Repair 7.

PEM1124ENG ENGLISH. STK TERMINATION KIT FOR PLASTIC CABLE WITHOUT ARMOURING 1 kv STKR TERMINATION KIT FOR PLASTIC CABLE WITH ARMOURING 1 kv

MOTOR LEAD TO DOWN HOLE CABLE SPLICE PROCEDURE

3M Pressurized Closure System 2-Type 505

Electrical Markets 3M ScotchCode Wire Marking and Identification System. Quality. Marking. For Most Projects

SLiC Fiber Aerial Closure 533 and 733

3M MetPak 2-FB Header

Instructions for Use of Overlap Seam Repair Kit:

3M Merchandising Catalog. Unrivaled. Product Presence to. Meet Your Merchandising Needs

3M Cross-Connect Cabinets 4220SVB, 4220SVC and 4220SVE 3M Junction Box (JBOX)

REQUIRED TOOLS. Wire cutters Razor blade Soldering iron Pliers 11/16 Wrench for Tube 18mm Wrench for Ring

LCC (Little Coaxial Connector) Installation Instructions)

Multi-Media Installation Guide

3M Fiber Optic Splice Closure 2178-L/S Series with Gasket

Crimp & Cleave Termination Instructions for SEL ST Connectors

Communication Markets Division. 3M Fiber Closures. Smart design makes your job easier.

Rotor Blade Protection Kit 8999K11

3M Cross-Connect Cabinets 4220SVB, 4220SVC and 4220SVE Skirt and Stabilizers

Transcription:

Industrial Loadbreak Elbow 200 A 5, 8, and 15 kvclass 5810 Series Installation Instructions 1.0 General The 3M Industrial Loadbreak Elbow connector is a fullyshielded and insulated plug-in termination for connecting underground cable to transformers, switching cabinets and junctions equipped with loadbreak bushings. The elbow connector and bushing insert comprise the essential components of all loadbreak connections. The coppertop (bimetal) compression connector is a standard item to transition from the cable to the loadbreak probe. An aluminum crimp barrel is inertia-welded to a copper lug. The aluminum barrel makes the connector easy to crimp and the copper lug ensures a reliable, tight, cool operating connection with the loadbreak probe. 2.0 Installation Cable stripping and scoring tools, available from various tool manufacturers, are recommended for use when installing loadbreak elbows. After preparing the cable and installing shield adapter, the elbow housing is pushed onto the cable. The loadbreak probe is threaded into the coppertop connector using the supplied installation tool or an approved equivalent. Use a shotgun stick to perform loadmake and loadbreak operations. (See page 10 for operating instructions.) Kit Contents: Elbow Body Coppertop Compression Connector Loadbreak Probe Probe Installation Tool Silicone Lubricant Cold Shrink Jacketing Tube Mastic Strips (3 ea.) Ground Braid Assembly Constant Force Spring CC-3 Cable Cleaning Pads Installation Instructions The 5810-CA and 5810-CB Series kits contain the following additional materials: Cable Adapter Silicone Lubricant Supplemental Installation Instructions Figure 1. Illustration of a completely assembled 15 kv loadbreak elbow, shown on tape shielded cable. These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every contingency during installation, operation, or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for the user s purpose, please contact your 3M sales representative.

Installation Notes: Cable description (check kit selection table on page 3 Crimping Tool (check crimp chart on page 9) Location Installation comments 2

Table 1. Kit Selection Table for 5, 8 and 15 kv Class Kit No. Insulation 5 kv 8 kv 15 kv Dia. Range (AWG/kcmil) (AWG/kcmil) (AWG/kcmil) 100% 133% 100% 133% 100% 133% (90 mils) (115 mils) (115 mils) (140 mils) (175 mils) (220 mils) Inches Stranded Compact Stranded Compact Stranded Compact Stranded Compact Stranded Compact Stranded Compact (mm) /Solid /Solid /Solid /Solid /Solid /Solid 5810-CA** 0.495 0.585 2 1* 1 1/0* 2 2 1 2 2 1* 5810-CA-2 (12.6 14.9) 2 1 2* 1 2 1* 5810-CA-1 1* 1/0* 5810-CB** 0.575 0.685 1/0 2/0 2/0 1 1/0 1/0 1-1/0 1/0 2 2 1 4 5810-CB-4 (14.6 17.4) 4 5810-CB-2 2 1 5810-CB-1 1 1/0 1 1/0 5810-CB-1/0 1/0 2/0 1/0 1/0 5810-CB-2/0 2/0 5810-A** 0.630 0.820 3/0 4/0 3/0 250 2/0 3/0 2/0 4/0 2/0 3/0 2/0 4/0 1 2/0 1/0 3/0 2 1 2 1/0 4 2 5810-A-3 (16.0 20.8) 2 2 5810-A-2 2 1 5810-A-1 1 1/0 1 1/0 5810-A-1/0 2/0 2/0 1/0 2/0 5810-A-2/0 3/0 2/0 3/0 2/0 3/0 2/0 3/0 5810-A-3/0 3/0 4/0 3/0 4/0 3/0 4/0 5810-A-4/0 4/0 250 5810-B** 0.700 0.910 250 4/0 250 250 4/0 250 250 3/0 4/0 4/0 250 1/0 2/0 2/0 3/0 2 1/0 1 2/0 5810-B-2 (17.8 23.1) 2 1 5810-B-1 1 1/0 5810-B-1/0 1/0 2/0 1/0 2/0 5810-B-2/0 2/0 3/0 5810-B-3/0 3/0 4/0 5810-B-4/0 4/0 250 4/0 250 4/0 250 5810-B-250 250 250 250 5810-C** 0.850 1.100 250 3/0 250 4/0 250 2/0 4/0 3/0 250 5810-C-2/0 (21.6 27.9) 2/0 3/0 5810-C-3/0 3/0 4/0 3/0 4/0 5810-C-4/0 4/0 250 4/0 250 5810-C-250 250 250 5810-D** 1.040 1.250 250 5810-D-250 (26.4 31.8) 250 Notes: *Check actual cable insulation diameter to verify correct kit selection. **Kit without compression connector. 3

3.0 Preparation of Tape Shield Cable 3.1 3.2 3.3 3.4 z,y,yz,z y, 3.1 Check to be sure cable size fits within the kit range as shown in Table 1, page 3. Remove cable jacket for 8 1 4 " (210 mm). 3.2 Remove metallic tape shield, leaving 1 1 4 " (32 mm) exposed beyond cable jacket. (If necessary to prevent the tape shield from unwinding, temporarily hold down end of shield with a wrap of vinyl electrical tape.) Remove semi-con (insulation shield), leaving 2 3 8 " (60 mm) beyond cable jacket. Remove cable insulation for 2 1 8 " (54 mm). Place a 1 8 " (3 mm) bevel on end of cable insulation, to ease installation. 3.3 Remove white liners from one mastic strip and apply one wrap around cable jacket 1 2 " (13 mm) from edge. Apply with light tension. Cut off excess mastic. Position preformed ground braid with long leg along cable jacket as shown, with braid solder block centered on previously applied mastic strip. Wrap short leg of ground braid around cable metallic tape shield for one complete wrap. Trim excess to eliminate overlap. (Remove temporary wrap of vinyl tape if applicable.) 3.4 Secure ground braid to metallic tape shield with constant force spring. Wrap spring in same direction as ground braid, as shown. Cinch (tighten) the last wrap of spring. Remove liners from second mastic strip and apply one wrap over solder block and previously applied mastic strip. Cut off excess mastic. Apply two half-lapped layers of vinyl tape over mastic, constant force spring and exposed tape shield. 4

4.0 Preparation of Wire Shield Cable 4.1 4.2 4.3 4.4 z,y,yz, z, y 4.1 Check to be sure cable size fits within the kit range as shown in Table 1, page 3. Remove cable jacket for 8 1 4 " (210 mm). 4.2 Cut-off shield wires, leaving 1 1 4 " (32 mm) exposed beyond cable jacket. Remove semi-con (insulation shield), leaving 2 3 8 " (60 mm) beyond cable jacket. Remove cable insulation for 2 1 8 " (54 mm). Place a 1 8 " (3 mm) bevel on end of cable insulation, to ease installation. 4.3 Remove white liners from one mastic strip and apply one wrap around cable jacket 1 2 " (13 mm) from edge. Apply with light tension. Cut off excess mastic. Position preformed ground braid with long leg along cable jacket as shown, with braid solder block centered on previously applied mastic strip. Wrap short leg of ground braid around cable wire shield for one complete wrap. Trim excess to eliminate overlap. 4.4 Secure ground braid to wire shield with constant force spring. Wrap spring in same direction as ground braid, as shown. Cinch (tighten) the last wrap of spring. Remove liners from second mastic strip and apply one wrap over solder block and previously applied mastic strip. Cut off excess mastic. Apply two half-lapped layers of vinyl tape over mastic, constant force spring and exposed wire shield. 5

5.0 Preparation of UniShield Cable 5.1 5.2 5.3 5.4 z,y y z,y, 5.1 Check to be sure cable size fits within the kit range as shown in Table 1, page 3. Note: UniShield cable has compact conductor. Mark cable jacket 7" (178 mm) from cable end (a temporary wrap of vinyl tape can be used as a marker). Use a needle-nose pliers to pull each individual drain wire out through cable semi-con jacket, back to previously applied mark. (Remove vinyl tape if it was used as a temporary marker.) Cut off wires leaving 1 1 8 " (29 mm) exposed. Carefully bend drain wires back along cable jacket. Keep wires separated and spaced around cable. 5.2 Temporarily install constant force spring over cable semi-con jacket, 5 7 8 " (149 mm) from cable end. Score semi-con jacket (cut 80% through) at edge of spring. Remove jacket sections by carefully pulling against spring. Use care not to lift (bell) the end of the jacket. Remove constant force spring (save spring for later ground installation.) 5.3 Remove cable insulation for 2 1/8" (54 mm). Place a 1/8" (3 mm) bevel on end of cable insulation to ease installation. Remove white liners from 1 mastic strip and apply 1 wrap around cable semi-con jacket 2 7 8 " (73 mm) from edge. Apply with light tension. Cut off excess mastic. Position preformed braid with long leg along cable jacket as shown, with braid solder block centered on previously applied mastic strip. Wrap short leg of ground braid around bent back drain wires for 1 complete wrap. Trim excess to eliminate overlap. 5.4 Secure ground braid to drain wires with constant force spring. Wrap spring in same direction as ground braid, as shown. Cinch (tighten) the last wrap of spring. Remove liners from 2nd mastic strip and apply 1 wrap over solder block and previously applied mastic strip. Cut off excess mastic. Apply 2 half-lapped layers of vinyl tape over mastic, constant force spring and exposed drain wires. 6

6.0 Preparation of Jacketed Concentric Neutral Cable 6.1 6.2 6.3 6.4 Note: The ground braid assembly and constant force spring are not used for this application. 6.1 Check to be sure cable size fits within the kit range as shown in Table 1, page 3. Remove cable jacket for 8 1 4 " (210 mm). 6.2 Remove white liners from 1 mastic strip and apply 1 wrap around cable jacket 1 2 " (13 mm) from edge. Apply with light tension. Cut off excess mastic. Bend neutral wires back over mastic strip and secure to cable jacket 2" (51 mm) from jacket end. Keep wires separated and spaced around cable. 6.3 Remove white liners from 2nd mastic strip and apply 1 wrap over neutral wires and previously applied mastic strip. Press neutral wires into mastic by applying 2 highly stretched half-lapped layers of vinyl tape over mastic and bent-back neutral wires. 6.4 Continue cable preparation. Remove semi-con (insulation shield) for 5 7 8 " (149 mm), leaving 2 3 8 " (60 mm) exposed beyond cable jacket. Remove cable insulation for 2 1 8 " (54 mm). Place a 1 8 " (3 mm) bevel on end of cable insulation to ease installation. 7

7.0 Elbow and Loadbreak Probe Installation Note: 5810-CA and 5810-CB Series Kits ONLY Refer to Supplemental Installation Instructions provided in kit for installation of Loadbreak Elbow Adapter. (Then continue elbow installation according to the main kit instructions.) 7.0 Elbow and Loadbreak Probe Installation 7.1 7.2 7.3 7.4 7.1 Clean the exposed conductor using a wire brush. Place the coppertop (bimetal) connector on the conductor. Make sure threaded hole in connector faces the apparatus bushing. Crimp the connector in place using a tool and die combination listed in Table 2. Start crimping just below the knurled line and rotate each successive crimp to prevent bowing. Do not overlap crimps. Place as many crimps on the connector as will fit. Clean excess inhibitor grease from coppertop connector by wiping toward threaded eye. Clean cable insulation with solvent pad(s) from 3M CC-3 Cable Cleaning Kit. Do Not allow solvent to touch cable semi-con. Note: If use of an abrasive cloth is necessary, use an electrical grade (non-conductive) abrasive. A 120 grit abrasive is recommended. 7.2 Slide Cold Shrink assembly over cable with loose core end leading (away from cable end). Temporarily position it just beyond prepared cable end. 7.3 Apply a thin coating of silicone lubricant to the cable insulation. Clean and lubricate the cable entrance of the elbow. Place elbow on cable. With a twisting motion, push elbow onto cable until threaded eye of coppertop connector is aligned with the elbow. 7.4 By hand, thread loadbreak probe into threaded eye of coppertop connector. When tight, use the provided installation tool to properly torque the loadbreak probe. Proper torque is applied when the tool achieves a 180 o permanent set. Note: If a different installation tool is used it must apply a torque of 110 in-lbs to achieve proper installation. 8

7.5 7.6 Clean and Lubricate Step Step Attach Ground Lead to Elbow Grounding Tab 1/2" (13 mm) Mastic Strip Cold Shrink Tubing Counter-Clockwise 7.5 Remove white liners from remaining mastic strip and apply around base of elbow, 1 2 " (13 mm) from step as shown. Apply 1 layer of vinyl tape over mastic. 7.6 Align Cold Shrink rubber tube (not core) with step of elbow. Remove core by pulling and unwinding the core counter-clockwise. Attach 14 AWG ground lead (from ground braid assembly) to the elbow grounding eye. Connect ground braid to system ground. (For jacketed concentric neutral cable, attach a neutral strand to grounding eye, and connect remaining neutral bundle to system ground.) Table 2. Crimp Chart. Connector 5 / 8" Diameter 3 / 4" Diameter Conductor Size 4 AWG through 2/0 Stranded 3/0 AWG through 250 kcmil Stranded Tool Y34 Y35 OR Y39 MD6 Y34 Y35 OR Y39 MD6 Burndy Die A243 U243 UBG W243 WBG U247 U247 U467 W247 A25AR U25ART U687 BG W687 A27AR U27ART Nose Thomas Tool UT-3 UT-5 UT-15 UT-5 UT-15 & Betts Die 5 / 8" TV 54 H TV 66 Kearney Tool 0 H-1, H-2 0 H-1, H-2 Die 5 / 8" Nose 9 / 16" 9 / 16" 572 737 747 737 747 Alcoa Tool 12A 12A Die B24 EA B39 EA Anderson Tool VC-5, VC-6 VC-5, VC-6 EEI Reference 8A 10A 9

8.0 Operating Instructions 8.1 Before Loadmake or Loadbreak Operation: Area must be clear of obstructions or contaminants that would interfere with the operation of the connector. This position should allow you to establish firm footing and enable you to grasp the shotgun stick securely, maintaining positive control over the movement of the loadbreak connector before, during and directly after the operating sequence. Because of the control, speed and force required to engage or disengage the elbow, certain operating positions are more advantageous than others. If there is some question as to proper operating position, it is recommended that the connectors be operated deenergized. Do not connect two different phases of a multiple-phase system. Before closing a single-phase loop, make certain both ends of the loop are the same phase. 8.2 Loadmake Operation Area must be clear of obstructions or contaminants that would interfere with the operation of the loadbreak elbow. Securely fasten a shotgun stick to the pulling eye. Place the loadbreak elbow over the bushing, inserting the loadbreak probe into the bushing until the first slight resistance is felt. Resistance is felt when the arc follower portion of the loadbreak probe first meets the female contact of the bushing. Immediately thrust the elbow onto the bushing with a fast, firm, straight motion, with sufficient force to latch the elbow to the bushing. 8.3 Fault Close It is not recommended that operations be made on known faults. If a fault is experienced, both the elbow connector and the bushing must be replaced. 8.4 Loadbreak Operation Securely fasten a shotgun stick to the pulling eye. Without exerting any pulling force, slightly rotate the connector clockwise in order to break surface friction between the elbow and bushing. Withdraw the connector from the bushing with a fast, firm, straight motion, being careful not to place the connector near a ground plane. Place connector on appropriate accessory device, following the operating instructions for that accessory. 10

11

3M is a registered trademark of 3M. UniShield is a registered trademark of BICC Cables. Note: The core material being removed from the Cold Shrink Tube is mixed polymers and can be recycled with other waste. IMPORTANT NOTICE Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated with such use. Warranty; Limited Remedy; Limited Liability. This product will be free from defects in material and manufacture as of the date of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3M s option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will not be liable for any loss or damage arising from this 3M product, whether direct, indirect, special, incidental or consequential regardless of the legal theory asserted. Electrical Products Division 6801 River Place Blvd. Austin, TX 78726-9000 800/245-3573 Printed on 50% recycled paper Litho in USA www.3m.com/elpd with 10% post-consumer 3M IPC 2000 -B