Panduit Opti-Core iber Optic Cable High-Speed iber Cabling Systems Panduit provides high bandwidth and mission-critical physical infrastructures in data center, enterprise, and campus networks with comprehensive fiber optic systems that deliver high performance, reliability, and scalability. The deployment of high-speed cabling systems has been increasing rapidly as data centers enable their physical infrastructure with 0 Gb/s capacity to support server virtualization, I/O consolidation, and convergence of backbone applications. Structured Cabling Infrastructure A properly designed and implemented cabling infrastructure is a fundamental asset of every business. Carefully planning a structured cabling solution facilitates the delivery of new services, lowers network maintenance costs, and increases productivity. New high-bandwidth applications enable organizations to better fulfill their need for productivity and innovation in a rapidly changing world. Innovative Data Center Infrastructure Solutions Panduit provides a comprehensive, intelligent data center offering that supports best practice methodologies. Our data center solutions enable physical to logical architecture integration, and deliver robust, scalable physical infrastructures that address: Visibility and control for managing and automating real-time data processes and documentation Convergence of new technologies and high-speed data applications Operational efficiency through process improvement and IT initiatives, such as cooling conservation through energy efficient data cabinets Capacity management for greater real estate utilization Modular pods designed to support high-density applications and provide consistent, reliable deployments while lowering infrastructure risk and costs Panduit s intelligent data center solutions facilitate faster implementation and simple specification, streamlining the process of designing, specifying, installing, and managing the increasingly complex physical infrastructure necessary to optimize your data center. Panduit knows the data center space intimately. We help you discover tangible infrastructure and business process improvements that increase functionality, interoperability, and manageability of mission-critical operations across your entire organization. High Speed Data Transport Solutions High Speed Data Transport (HSDT) Solutions are a set of complementary copper and optical fiber technologies for mission critical data center applications, spanning storage and compute requirements and leading edge architectures. Based on an understanding of today s vital business and technology challenges and how they impact data centers, Panduit has created best-in-class physical infrastructure solutions for HSDT. Panduit provides the broadest offering of end-to-end HSDT solutions supporting all data center architectures. Designed for high-density/high-speed applications, Panduit HSDT solutions are backed by comprehensive research and development programs to ensure high network performance, systems reliability, energy efficiencies, and seamless integration. PanNet System Warranty All Panduit channels are field tested by Panduit Certified Installers (PCI) using industry standard hand-held devices which provide verified network performance, and ensures your network operates at optimal performance. Visit www.panduit.com for more information.
Panduit Opti-Core iber Optic Cable Cable ire Ratings Reference Guide Cable fire ratings need to be considered when specifying cabling infrastructure to ensure local building codes are met. The below rating guide provides the information needed to determine which rating is appropriate for different installation environments. Plenum Rated Cable (ONP) A Plenum Rating (ONP) signifies cable that has passed stringent burn testing and is suitable for installation into air plenum spaces. ONP cables have fire-resistance and low smoke production characteristics. They can be installed in ducts, plenums, and other spaces used for building airflow. This is the highest fire rating fiber cable and no other cable types can be used as substitutes. Plenum Rated Cable (OCP) A Plenum Rating (OCP) differs from ONP in that the cable contains metallic elements, typically armor, and therefore, conducts electricity. All other aspects of this rating are the same as ONP. Riser Rated Cable (ONR) A Riser Rating (ONR) is commonly required when cables are run between floors through open vertical shafts. ONR cables are used in Riser areas which are building vertical shafts or runs from one floor to another floor. ONR cables cannot be installed in plenum areas since they do not have the required smoke rating as plenum rated cables. ONP plenum cables can be used as substitutes for ONR Riser cables. Riser Rated Cable (OCR) A Riser Rating (OCR) differs from ONR in that the cable contains metallic elements, such as a layer of armor, and therefore, conducts electricity. All other aspects of this rating are the same as ONR. ow Smoke Zero Halogen (SZH) A ow Smoke Zero Halogen Rating (SZH) is sometimes referred to as low toxicity cable. When burned, PVC-based cables produce a cloud of toxic smoke containing corrosive compounds such as hydrochloric acid. The SZH cables do not contain the Halogen type compounds that form these toxic substances. Smoke emitted from burning SZH cables do not produce the toxic halogen-based gasses previously mentioned. SZH ratings are expressed as ON-S or ONR-S if the cable also meets the requirements of a ONR rated cable. Non-lame Rated Outside Plant (OSP) cables are intended for outdoor use only. Typically, these cables are constructed using varying densities of Polyethylene, (PE) in the outer jacket, and perhaps in other OSP cable components. Because cables without flame ratings do not contain flame suppressants and emit noxious gasses when burned, building codes often restrict the distance installers are permitted to route inside buildings before termination.
iber Cable for Americas (North America and atin America) Opti-Core Interconnect Cable Used in interconnect, horizontal installations, routing in tight spaces such as panels, cable trays, and fiber-to-the-desk (TTD) applications. Strength 900µm buffer S I P 0 Y and iber Product S = iber OM, OM, OS O = iber OM, OM Cable Construction I = Interconnect cable lame Rating P = Plenum R = Riser iber Type 9 = OS 9/µm = OM.//µm = OM 0/µm X = OM 0G 0/µm Z = OM 0G 0/µm and iber Count 0 = -fiber RoHS Y = RoHs compliant Opti-Core Indoor Distribution Cable or indoor use in intra-building backbone and horizontal installations. 900µm buffer Strength S D P 0 Y and iber Product S = iber OM, OM, OS O = iber OM, OM Cable Construction D = Distribution cable lame/smoke Rating R = Riser (ONR) P = Plenum (ONP) iber Type 9 = OS 9/µm = OM./µm = OM 0/µm X = OM 0G 0/µm Z = OM 0G 0/µm and iber Count 0 = -fiber = -fiber = -fiber = -fiber = -fiber = -fiber RoHS Y = RoHS compliant Visit www.panduit.com for more information.
iber Cable for Americas (North America and atin America) Opti-Core Indoor/Outdoor All-Dielectric Cable with Tight Buffered ibers These cables provide an effective solution for inter-building and building transition applications. Buffer Aramid strength S K R and iber Product S = iber OM, OM, OS O = iber OM, OM Cable Construction K = Indoor/outdoor tight buffered unarmored lame/smoke Rating R = Riser P = Plenum iber Type 9 = OS 9/µm = OM.//µm = OM 0/µm X = OM 0G 0/µm Z = OM 0G 0/µm and iber Count 0 = -fiber 0 = -fiber 0 = -fiber 0 = -fiber = -fiber = -fiber = -fiber = -fiber = -fiber 9 = 9-fiber A = -fiber (Riser only) Opti-Core Indoor/Outdoor All-Dielectric Cable Allows installation using loose tube cable methods within buildings and outdoor environments for transitional aerial, duct applications, and entrance facilities. Water-blocking strength Dry-blocked buffer tube Rip cord 0µm optical fibers (up to ) Outer strength lame retardant outer jacket S C P 0 Y and iber Product S = iber OM, OM, OS O = iber OM, OM Cable Construction C = Indoor/outdoor central tube (up to fibers) N = Indoor/outdoor stranded tube ( fibers and greater) lame Rating R = Riser P = Plenum iber Type 9 = OS 9/µm = OM./µm = OM 0/µm X = OM 0G 0/µm Z = OM 0G 0/µm and iber Count 0 = -fiber = -fiber = fiber = fiber = fiber = fiber 9 = 9 fiber A = fiber RoHS Y = RoHS compliant
iber Cable for Americas (North America and atin America) Opti-Core Interlocking Armored Cable Offering Opti-Core Indoor Interlocking Armored Cable Used in intrabuilding backbone, building backbone, and horizontal installations and harsh environments. Cable outer jacket 900µm buffer Strength Overlaid jacket Aluminum interlocking armor Opti-Core Indoor/Outdoor Interlocking Armored Cable with Tight Buffered ibers or use indoors and outdoors. Interlocking aluminum armor eliminates the need for inner duct or conduit. Cable outer jacket Buffer Overlaid jacket Aluminum interlocking armor Strength Visit www.panduit.com for more information.
iber Cable for Americas (North America and atin America) Opti-Core Indoor/Outdoor Interlocking Armored Cable or use indoor and outdoors. Central loose tube constructions. Interlocking aluminum armor eliminates the need for inner duct or conduit. lame retardant jacket Dry-blocked buffer tube containing up to () 0µm fibers Overlaid jacket Rip cord Water-blocking strength member S G P 0 Y and iber Product S = iber OM, OM, OS O = iber OM, OM Cable Construction G = Indoor/outdoor interlocking armored central tube (up to fibers) M = Indoor/outdoor interlocking armored stranded tube ( fibers and greater) = Indoor/outdoor tight buffered P = Indoor interlocking armored lame Rating R = Riser P = Plenum iber Type 9 = OS 9/µm = OM./µm = OM 0/µm X = OM 0G 0/µm Z = OM 0G 0/µm and iber Count 0 = -fiber 0 = -fiber 0 = -fiber 0 = -fiber = -fiber = -fiber = -fiber = -fiber = fiber 9 = 9-fiber A = -fiber RoHS Y = RoHS compliant
iber Cable for Americas (North America and atin America) Opti-Core Dielectric Conduited iber (DC) Optic Cable or indoor use in intra-building backbone and horizontal installations. Cable outer jacket Aramid strength Dielectric conduit Buffer 9 0 S A D B and iber Product S = OM, OM, OS O = OM, OM Cable Construction A = Dielectric Conduited Distribution (indoor lame/smoke Rating D = Dual rated riser (ONR) and low smoke zero halogen iber Type 9 = OS 9/µm = OM./µm = OM 0/µm X = OM 0G 0/µm Z = OM 0G 0/µm and iber Count 0 = -fiber 0 = -fiber 0 = -fiber 0 = -fiber = -fiber Dash 9 and 0 Jacket color B = Black Opti-Core Gel-ree All-Dielectric Outside Plant Cable or use outdoors in aerial and duct applications. Dry-blocked buffer tube containing or fibers Rip cord Central strength member Outer strength iller tube Water-blocking tape O T N X 0 and iber Product S = iber OM, OM, OS O = iber OM, OM Visit www.panduit.com for more information. Cable Construction T = Outside plant stranded cable (all fiber counts) lame Rating N = Non-rated iber Type 9 = OS 9/µm = OM.//µm = OM 0/µm X = OM 0G 0/µm Z = OM 0G 0/µm and iber Count 0 = -fiber = -fiber = -fiber = -fiber = -fiber = -fiber 9 = 9-fiber A = -fiber
iber Cable for Americas (North America and atin America) Opti-Core Gel-ree Armored Outside Plant Cable Corrugated steel armor provides superior crush resistance for extended durability in direct burial applications. Dry-blocked buffer tube containing or fibers Rip cord Central strength member Outer strength iller tube Corrugated steel armor Water-blocking tape O W N X 0 and iber Product S = iber OM, OM, OS O = iber OM, OM Cable Construction W = Outside plant armored stranded cable (all fiber counts) lame/smoke Rating N = Non-rated iber Type 9 = OS 9/µm = OM./µm = OM 0/µm X = OM 0G 0/µm Z = OM 0G 0/µm and iber Count 0 = -fiber = -fiber = -fiber = -fiber = -fiber = -fiber 9 = 9-fiber A = -fiber 9
ibre Cable for EMEA (Europe, Middle East, and Africa) Opti-Core Interconnect Cable Used in interconnect, horizontal installations, and for routing in tight spaces such as panels, cable trays, and fibre-to-the-desk (TTD) applications. Cable print legend 900µm Buffer Optical fibre 900µm Buffer Strength Outer jacket P I 0 and ibre Product P = ibre OM, OM, OS Q = ibre OM, OM Cable Construction I = Interconnect zip-cord cable lame Rating = ow smoke zero halogen (SZH) ibre Type 9 = OS 9/µm = OM./µm = OM 0/µm X = OM 0G 0/µm Z = OM 0G 0/µm and ibre Count 0 = -fibre Opti-Core Indoor Distribution Cable or indoor use in intrabuilding backbone and horizontal installations. Optical fibre Strength 900µm Buffer Outer jacket P D 9 and ibre Product P = ibre OM, OM, OS Q = ibre OM, OM Cable Construction D = Distribution cable lame/smoke Rating = ow smoke zero halogen (SZH) ibre Type 9 = OS 9/µm = OM./µm = OM 0/µm X = OM 0G 0/µm Z = OM 0G 0/µm and ibre Count 0 = -fibre 0 = -fibre = -fibre = -fibre = -fibre = -fibre 0 Visit www.panduit.com for more information.
ibre Cable for EMEA (Europe, Middle East, and Africa) Opti-Core Indoor/Outdoor All-Dielectric Cable with Tight Buffered ibres or indoor and outdoor use. Optical fibre Strength 900µm Buffer Outer jacket P K and ibre Product P = ibre OM, OM, OS Q = ibre OM, OM Cable Construction K = Indoor/outdoor tight buffered unarmored lame Rating ow smoke zero halogen ibre Type 9 = OS 9/µm = OM./µm = OM 0/µm X = OM 0G 0/µm Z = OM 0G 0/µm and ibre Count 0 = -fibre 0 = -fibre 0 = -fibre 0 = -fibre = -fibre = -fibre = -fibre = -fibre = -fibre 9 = 9-fibre Opti-Core Indoor/Outdoor All-Dielectric Cable or use indoor or outdoors. Central and stranded loose tube constructions are all-dielectric. Water-blocking tape Outer strength Central strength member Rip cord to iller tubes,, or ibre, gel-filled, buffer tube sub-unit lame retardant tape lame retardant outer jacket P N and ibre Product P = ibre OM, OM, OS Q = ibre OM, OM Cable Construction C = Indoor/outdoor central tube (up to fibres) N = Indoor/outdoor stranded tube ( fibres and greater) lame Rating = ow smoke zero halogen (SZH) ibre Type 9 = OS 9/µm = OM./µm = OM 0/µm X = OM 0G 0/µm Z = OM 0G 0/µm and ibre Count 0 = -fibre 0 = -fibre = -fibre = -fibre = -fibre = -fibre = -fibre 9 = 9-fibre
ibre Cable for EMEA (Europe, Middle East, and Africa) Opti-Core Dielectric Conduited (DC) ibre Optic Cable or indoor use in intrabuilding backbone and horizontal installations. Cable outer jacket Aramid strength Optical fibre Buffer Dielectric conduit 9 0 S A D B and ibre S= OM, OM, OS O= OM, OM Cable Construction A = Dielectric conduited distribution (indoor) lame/smoke Rating D = Dual rated riser (ONR) and low smoke zero halogen (SZH) ibre Type 9 = OS 9/µm = OM./µm = OM 0/µm X = OM 0G 0/µm Z = OM 0G 0/µm and ibre Count 0 = -fibre 0 = -fibre 0 = -fibre 0 = -fibre = -fibre Dash 9 and 0 Jacket color B = Black Opti-Core Gel-illed All-Dielectric Outside Plant Cable or use outdoors in aerial or duct applications. Stranded loose tube constructions are all-dielectric. No need to ground or bond. Gel-filled tube containing up to fibre Rip cord Central strength member Strength member iller tube Water-blocking tape P T N and ibre Product P = ibre OM, OM, OS Q = ibre OM, OM Visit www.panduit.com for more information. Cable Construction U = Indoor/outdoor central tube (up to fibres) T = Indoor/outdoor stranded tube (all fibre counts) lame Rating N = Non-rated ibre Type 9 = OS 9/µm = OM./µm = OM 0/µm X = OM 0G 0/µm Z = OM 0G 0/µm and ibre Count 0 = -fibre 0 = -fibre = -fibre = -fibre = -fibre = -fibre = -fibre 9 = 9-fibre A = -fibre
ibre Cable for EMEA (Europe, Middle East, and Africa) Opti-Core Gel-illed Single Armor Single Jacket Outside Plant Cable or use outdoors in direct burial applications. Central loose tube constructions are armored with corrugated steel tape for greater crush resistance. Rip cord lame retardant jacket Gel-filled tube containing 0µm fibers Corrugated steel armor Water blocking strength member P S N and ibre Product P = ibre OM, OM, OS Q = ibre OM, OM Cable Construction S = Gel-filled single armor single jacket outside plant cable lame Rating N = Non-rated ibre Type 9 = OS 9/µm = OM./µm = OM 0/µm X = OM 0G 0/µm Z = OM 0G 0/µm and ibre Count 0 = -fibre 0 = -fibre 0 = -fibre = -fibre = -fibre Opti-Core Gel-illed Single Armor Double Jacket Outside Plant Cable or use outdoors in direct burial applications. Stranded loose tube constructions are armored with corrugated steel tape for greater crush resistance. Gel-filled tube containing up to fibres Rip cord Central strength member Strength member iller tube Corrugated steel armor Inner jacket P Q N B and ibre Product P = ibre OM, OM, OS Q = ibre OM, OM Cable Construction Q = Gel-filled single armor double jacket outside plant cable lame Rating N = Non rated ibre Type 9 = OS 9/µm = OM./µm = OM 0/µm X = OM 0G 0/µm Z = OM 0G 0/µm and ibre Count 0 = -fibre 0 = -fibre 0 = -fibre 0 = -fibre = -fibre = -fibre = -fibre = -fibre = -fibre 9 = 9-fibre A = -fibre ibre Cable B = single armor double jacket stranded tube
iber Cable for APAC (Asia Pacific) Opti-Core Interconnect Cable Used in interconnect, horizontal installations, routing in tight spaces such as panels, cable trays, and fiber-to-the-desk (TTD) applications. Strength 900µm buffer I X 0 Y and iber Product = iber OS, OM, OM, OM, OM Cable construction I = Interconnect zipcord lame/smoke Rating = ow smoke zero halogen (SZH) R = Riser iber Type 9 = OS 9/µm = OM./µm = OM 0/µm X = OM 0G 0/µm Z = OM 0G 0/µm and iber Count 0 = -fiber RoHS Y = RoHs compliant Opti-Core Indoor Distribution Cable or indoor use in intrabuilding backbone and horizontal installations. Strength 900µm buffer D 0 Y and iber Product = iber OS, OM, OM, OM, OM Cable Construction D = Distribution cable lame/smoke Rating = ow smoke zero halogen (SZH) R = Riser Visit www.panduit.com for more information. iber Type 9 = OS 9/µm = OM./µm = OM 0/µm X = OM 0G 0/µm Z = OM 0G 0/µm and iber Count 0 = -fiber 0 = -fiber 0 = -fiber 0 = -fiber = -fiber = -fiber = -fiber = -fiber RoHS Y = RoHS compliant
iber Cable for APAC (Asia Pacific) Opti-Core Indoor/Outdoor All-Dielectric Cable with Tight Buffered ibers or use indoor and outdoors. Strength 900µm Buffer K R and iber Product = iber OM, OM, OS, OM, OM Product Type K = Indoor/outdoor tight buffered unarmored lame/smoke Rating R = Riser (ONR) = ow Smoke Zero halogen (SZH) iber Type 9 = OS 9/µm = OM./µm = OM 0/µm X = OM 0G 0/µm Z = OM 0G 0/µm and iber Count 0 = -fiber 0 = -fiber 0 = -fiber = -fiber = -fiber = -fiber = -fiber = -fiber Opti-Core Indoor/Outdoor All-Dielectric Cable or use indoor or outdoors. Central loose tube and stranded loose tube constructions are all-dielectric. Central loose tube Water-blocking gel 0µm coated optical fiber Rip cord Water-blocking glass yarn C 0 Y and iber Product = iber OM, OM, OS, OM, OM Product Type C = Indoor/outdoor central tube (up to fibers) N = Indoor/outdoor stranded tube ( fibers and greater) lame/smoke Rating R = Riser (ONR) = ow smoke zero halogen (SZH) iber Type 9 = OS 9/µm = OM./µm = OM 0/µm X = OM 0G 0/µm Z = OM 0G 0/µm and iber Count 0 = -fiber 0 = -fiber 0 = -fiber = -fiber = -fiber = -fiber = -fiber
iber Cable for APAC (Asia Pacific) Opti-Core Dielectric Conduited (DC) iber Optic Cable or indoor use in intrabuilding backbone and horizontal installations. Cable outer jacket Aramid strength 900µm Buffer Dielectric conduit 9 0 S A D B and iber Product S= OM, OM, OS O= OM, OM Cable Construction A = Dielectric conduited distribution (indoor) lame/smoke Rating D = Dual rated riser (ONR) and low smoke zero halogen (SZH) iber Type 9 = OS 9/ µm = OM./µm = OM 0/µm X = OM 0G 0/µm Z = OM 0G 0/µm and iber Count 0 = -fiber 0 = -fiber 0 = -fiber 0 = -fiber = -fiber Dash 9 and 0 Jacket color B = Black Opti-Core Gel-illed All-Dielectric Outside Plant Cable or use outdoors in aerial or duct applications. Stranded constructions are all-dielectric. Gel-filled. Non-rated PE outer jacket. Tube containing up to fibers Rip cord Central strength member Outer strength member iller tubes T N and iber = iber OS, OM, OM, OM, OM Cable Construction T = Outside plant stranded cable (all fiber counts) lame/smoke Rating N = Non-rated iber Type 9 = OS 9/µm = OM./µm = OM 0/µm X = OM 0G 0/µm Z = OM 0G 0/µm and iber Count 0 = -fiber 0 = -fiber 0 = -fiber 0 = -fiber = -fiber = -fiber = -fiber = -fiber = -fiber 9 = 9-fiber A = -fiber Visit www.panduit.com for more information.
iber Cable for APAC (Asia Pacific) Opti-Core Gel-illed Armored Outside Plant Cable or use outdoors in direct burial applications. Stranded loose tube constructions are armored with corrugated steel tape for greater crush resistance. Gel-filled. Non-rated PE outer jacket. Gel-filled tube containing up to fibers Rip cord Central strength member Outer strength member iller tube Corrugated steel armor Water-blocking tape W N and iber Product = iber OS, OM, OM, OM, OM Cable Construction W = Outside plant armored stranded cable (all fiber counts) lame/smoke Rating N = Non-rated iber Type 9 = OS 9/µm = OM./µm = OM 0/µm X = OM 0G 0/µm Z = OM 0G 0/µm and iber Count 0 = -fiber 0 = -fiber 0 = -fiber 0 = -fiber = -fiber = -fiber = -fiber = -fiber = -fiber 9 = 9-fiber A = -fiber
Pre-Polished iber Optic Kit & Connectors OptiCam Pre-Polished Cam iber Optic Termination Kit or termination of all Panduit OptiCam Pre-Polished and ield Polish Connectors OptiCam Termination Tool simplifies tooling and termination, and virtually eliminates operator error by providing visual indication of proper termination after the cam step has been completed No adhesive or electricity required for pre-polished termination Include installation instructions and stripping templates for all Panduit OptiCam Pre-Polished Connectors; also available on www.panduit.com ield Polish iber Optic Termination Kit ast acting adhesive; no long curing epoxy required for field polish termination IEDKIT provides consumable for terminating up to 00 field polish connectors Include installation instructions and stripping templates for all Panduit ield Polish Connectors; also available on www.panduit.com IEDKIT for use with ield Polished iber Optic Connectors CAMKIT for use with Pre-Polished iber Optic Connectors OptiCam Pre-Polished and ield Polish iber Optic Connectors TIA/EIA-0 OCIS compatible connectors Exceed TIA/EIA--B. requirements Connector housing and boot colors follow TIA/EIA--C. suggested color identification scheme Non-optical disconnect maintains data transmission under tensile loads for jacketed cable Quick installation; provide field termination in less than half the time of field polish connectors Patented re-termination capability provides yield rates approaching 00% actory pre-polished fiber endface eliminates time-consuming field polishing to reduce installation costs, labor, scrap and the number of tools required Cam activated fiber and buffer clamp mechanisms provide superior fiber and buffer retention less sensitivity to fiber tensile loading Visit www.panduit.com for more information.
Pre-Polished iber Optic Kit & Connectors Opti-Cam Pre-Polished iber Optic Connectors C OptiCam Pre-Polished iber Optic Connectors Quick installation - provides field termination in less than half the time of field polish connectors. Patented re-termination capability. selection information Part Number Connector Type errule Material iber errule inish Backbone Boot Average Insertion oss** Return oss CSMCXAQY CDMCXAQY Duplex 0 GbE 0/μm (laser optimized) OM/OM SPC Aqua Aqua 0.dB >db CSMCBY CDMCBY Duplex 0/μm OM SPC Black Black 0.dB >0dB CSMCBY CDMCBY Duplex./μm OM SPC Electric Ivory Black 0.dB >0dB CSSCBUY CDSCBUY Duplex 9/μm OS/OS UPC Blue Blue 0.dB >0dB *All connector insertion loss values calculated from tests taken with precision launch jumper assemblies per TIA/EIA-OTP-. SC OptiCam Pre-Polished iber Optic Connectors selection information Part Number Connector Type errule Material iber errule inish Housing Backbone Boot Average Insertion oss** Return oss SCMCXAQ SCDMCXAQ Duplex 0 GbE 0/μm (laser optimized) OM/OM SPC Black Aqua Aqua 0.dB >db SCMCB SCDMCB Duplex 0/μm OM SPC Black Black Black 0.dB >0dB SCMPCB Composite SCMCB SCDMCB Duplex./μm OM SPC SCMPCB Composite SCSCBU Electric Ivory Electric Ivory Black 0.dB >0dB 9/μm OS/OS UPC Blue Blue Blue 0.dB >0dB **All connector insertion loss values calculated from tests taken with precision launch jumper assemblies per TIA/EIA-OTP-. 9
ield Polished iber Optic Kit & Connectors ST OptiCam Pre-Polished iber Optic Connectors selection information Part Number STMCXAQ STMCB STMCB STSCBU Connector Type errule Material **All connector insertion loss values calculated from tests taken with precision launch jumper assemblies per TIA/EIA-OTP-. iber 0 GbE 0/μm (laser optimized) OM/OM errule inish Backbone Boot Average Insertion oss** Return oss Aqua Aqua 0.dB >db 0/μm OM SPC Black Black 0.dB >0dB./μm OM Black Black 0.dB >0dB 9/μm OS/OS UPC Blue Blue 0.dB >0dB ield Polish iber Optic Connectors C OptiCam ield Polish iber Optic Connectors Non-optical disconnect maintains data transmission under tensile loads for jacketed cable. Tight buffered fiber cable type recommended. selection information Part Number CSMEIY Connector Type Cable Type iber errule 900μm buffered fiber and.mm.0mm jacketed cable CSM.0EI.0mm jacketed cable CDMEIY Duplex.mm.0mm jacketed cable CDM900EIY Duplex 900μm buffered fiber CDM.0EI Duplex.0mm jacketed cable CSMBY 900μm buffered fiber and.mm.0mm jacketed cable CSM.0B.0mm jacketed cable CDMBY Duplex.mm.0mm jacketed cable CDM900BY Duplex 900μm buffered fiber CDM.0B Duplex.0mm jacketed cable OM Multimode OM, OM, OM Multimode Housing Electric Ivory Boot Electric Ivory Average Insertion oss* Return oss 0.dB >0 Black Black 0.dB >0 *All connector insertion loss values calculated from tests taken with precision launch jumper assemblies per TIA/EIA-OTP-. 0 Visit www.panduit.com for more information.
ield Polished iber Optic Kit & Connectors SC OptiCam ield Polish iber Optic Connectors Part Number SCMB SCM.0B Connector Type Cable Type iber errule 900µm buffered fiber and.0mm jacketed cable 900 micron buffered fiber and..0mm jacketed cable SCDMB Duplex.0mm jacketed cable SCMB SCMRD SCM.0B SCM.0RD 900μm buffered fiber and.0mm jacketed cable 900μm buffered fiber and.0mm jacketed cable 900μm buffered fiber and.mm.0mm jacketed cable 900μm buffered fiber and.mm.0mm jacketed cable Multimode Housing *All connector insertion loss values calculated from tests taken with precision launch jumper assemblies per TIA/EIA-OTP-. Black Electric Ivory Boot SCDM Duplex.0mm jacketed cable Red and Black SCSBU SCS.0BU 900μm buffered fiber and.0mm jacketed cable 900μm buffered fiber and.mm.0mm jacketed cable Singlemode Black Red Black Red Average Insertion oss* Return oss 0.dB >0 Blue Blue 0.dB >0 ST OptiCam ield Polish iber Optic Connectors selection information Part Number Connector Type errule Material iber errule inish Housing Backbone Boot Average Insertion oss* Return oss STMAB STMARD STSABU Multimode UPC Black Multimode UPC Red Singlemode UPC Blue Nickel Plated Zinc Nickel Plated Zinc Nickel Plated Zinc Black Red Blue 0.dB (multimode) >0dB (multimode) 0.dB (multimode) >0dB (multimode) 0.0dB (singlemode) >0dB (singlemode) *All connector insertion loss values calculated from tests taken with precision launch jumper assemblies per TIA/EIA-OTP-.
Optical iber Coding TIA 9-C The Telecommunications Industry Association's TIA-9-C Optical iber Cable Coding, is an American National Standard, that provides all necessary information for color-coding optical fiber cables in a uniform manner. It defines identification schemes for fibers, buffered fibers, fiber units, and groups of fiber units within outside plant and premises optical fiber cables. This standard allows for fiber units to be identified by means of a printed legend. The legend will contain a corresponding printed numerical position number and/or color for use in identification. TIA-9-C iber Code Chart Blue Blue with black tracer Orange Orange with black tracer Green Green with black tracer Brown Brown with black tracer Slate Slate with black tracer White White with black tracer Red 9 Red with black tracer Black 0 Black with black tracer 9 Yellow Yellow with black tracer 0 Violet Violet with black tracer Rose Rose with black tracer Aqua Aqua with black tracer Contact Customer Service for fiber cable minimum order quantities, lead times, and stocked availability. Visit www.panduit.com for more information.
Panduit Corp. World Headquarters Tinley Park, I 0 cs@panduit.com US and Canada: 00..00 Europe, Middle East, and Africa:.0.0.00 atin America:...000 Asia Pacific:.0. www.panduit.com 0 Panduit Corp. A RIGHTS RESERVED. Printed in the U.S.A. BC0--SA-ENG 9/0