KACO-display. Wireless Solar Monitoring System. Operating Instructions KACO-display. full of energy...

Similar documents
Finding List by Question by State

Finding List by Question by State *

2017 Pocket Planners

Essential Learning Products

Golf ball tracker. Instruction manual

LCD Thermometer / Clock S No. 1253

CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC


Smart Control SC16 3-Channel for matrix

OPERATOR MANUAL OSD351 FIBRE OPTIC CCTV TRANSMITTER CARD

For use with QED and hardwired control panels ONLY!

LDG ALK-2 Two-Port Audio/Linear/Key Switch

User s Guide. 5.8GHz Wireless A/V Signal Sender

MS2540 Current Loop Receiver with RS485 Communication

Model: S-4904T/R. Wireless HD Transmission System. User Manual. Please read this User Manual throughout before using.

Introduction. Introduction

2.4 GHz WIRELESS VIDEO SENDER SYSTEM MODEL: VS6234

Indoor/Outdoor Security System with Quad Monitor User s Manual

RDR 2060 WEATHER RADAR UPGRADE

2.4GHz Digital Wireless Video Door Phone User Manual

GPS4000. GPS Time Receiver System. User Manual Version 1.1. World Time Solutions. World Time Solutions Limited

INSTALLATION INSTRUCTIONS FOR. MODEL 2230LED

DLP200M 2 Relay Module for Heating and Cooling Plants

INSTALLATION INSTRUCTIONS FOR

2.4 GHz WIRELESS SURVEILLANCE SYSTEM

User Manual. SWIT ELECTRONICS CO., LTD Model: S-4904P Wireless HD Transmission System(with Panel Receiver) Ver:A

ARS x4 MATRIX SWITCHER Instruction Manual

AVS50 USER GUIDE. 2.4GHz Audio/Video Sender System - AVS50

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: VP-2L UXGA Line Amplifier. P/N: Rev 3

User Guide. HDMI Active Cable Extender. DVI-7370c

QSDT404C User s Manual

Kramer Electronics, Ltd. USER MANUAL. Model: PT-102VN. 1:2 Video DA

USA WESTBOUND LCL SAILING SCHEDULES

OPERATOR MANUAL OSD8865 DIGITAL TRIPLE VIDEO FIBER OPTIC RECEIVER

ASP-FIBRS1 User Manual

User Guide. HDMI Fiber Optic Extender. DVI-7350a

Ultra-ViewRF 8HD Director Monitor. User Operation Manual

UDRC13 ACCESSORY CAMERA Owner s Manual

STD800LED Large display panel for photovoltaic systems

Process transmitter RMA422

Product model and standard

Operating Manual. Basic Control BC16. two-channel for eco moon

Operating Instructions

NT-9600 Wireless Barcode Scanner. Introduction

INSTALLATION INSTRUCTIONS MODEL VSBX-236 LED 3 X 8 INDOOR SCOREBOARD

ENGLISH Antenna Distributor

Kramer Electronics, Ltd. USER MANUAL. Model: TP-43. Component S/PDIF Transceiver

User Manual PS-684. HDBaseT Extender Kit 70m. All Rights Reserved. Version: UHBT70P_2016V1.2

Home Roam TV Basic User Manual

CR-R880-BL: Indoor/Outdoor Proximity Reader with 10cm (4in) read range

LINK-MI LM-WHD05B. Wireless HDMI AV Transmission System. User Manual

User Manual. Model 1372A and 1374A HDMI Switchers. 1T-SX-632 Model 1372A 2X1 Switcher. v1.3 2x1 SWITCHER. v1.3 INPUT ENHANCE POWER

Extender w/ RS-232 and 2-way IR

Kramer Electronics, Ltd. USER MANUAL. Model: VA-100P-5. Power Supply

Model R177M and R177S Baseband Switch

PSM-003. Micro Polarization Controller/Scrambler. User Guide

Instruction Manual. 4x1 VGA Routing Switcher Series

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

Galaxias. Flex LED display. User Manual

Audio. 4K Ultra HD Extender. w/ RS-232 and 2-way IR GTB-UHD2IRS-ELRPOL-BLK. User Manual. Release A2

INSTRUCTIONS FOR USE Pro-Ject Tuner Box S

DCE II Owner s Manual DVI over CATx Extension Module

USER MANUAL Table of Contents


Contents. Disclaimer of Product and Services

Installation and Operation Manual

USER MANUAL. KW-11T Wireless High Definition Transmitter. KW-11R Wireless High Definition Receiver MODELS: P/N: Rev 5

Getting started with

MICROSENS. Fast Ethernet Switch Modul 4x 10/100Base-TX, 1x 100Base-FX. Description. Features

Remote Control. degraded, causing unreliable operation. The recommended effective distance for remote operation is about 16 feet (5 meters).

USER MANUAL. KW-11T Wireless High Definition Transmitter. KW-11R Wireless High Definition Receiver MODELS: P/N: Rev 9

HTE Owner s Manual. HDMI, RS-232, IR & Ethernet Extender over HDBaseT with 3D, 4K, POE Support

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

User Guide. Single-Link DVI Active Cable Extender. DVI-7171c

Digital Terrestrial Alignment & Installation Meter

ACTIVE IF SPLITTER/COMBINER UHP-IFS

INSTRUCTIONS FOR USE Pro-Ject Tuner Box S2

DLP600M 6+1 Relay Module for Heating and Cooling Plants

MARCO CORNER, 19/ THIENE (VI) ITALIA

Absolute Encoders Multiturn

19 / 20.1 / 22 WIDE SCREEN TFT-LCD MONITOR

USER MANUAL. Kramer Electronics, Ltd. Models:

Kramer Electronics, Ltd.

Kramer Electronics, Ltd. USER MANUAL. Model: VS-33Vxl. 3x1 Video Switcher

HD Digital MPEG2 Encoder / QAM Modulator

HDBaseT Extender Set 100m User Guide

*Prefer. 600 MHz 4K ULTRA. 60Hz, 4:4:4. over one SC-Terminated Fiber-Optic Cable EXT-DP-4K600-1SC. User Manual. Release A1

VLHDMIEXTFIB_2017V1.0

Instructions for Use P.154-UP (9/4) P.155-UP (9/8) P.150-UP-12 (9/12) P.150-UP-16 (9/16)

english SGC inverter series hf transformer input voltage up to 800 V touch screen built-in data loggers

Dual Antenna Wireless Multi-Channel Expandable HDMI Extender Installation Guide

SY-HDBT-100 Extender Set

The Art of Engineering

VGA Extender SRN. EXT-VGA-141SRN. User Manual

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

Part No./ 型号 : RGB-Controller-101

INTRODUCTION INSTALLATION LIGHTNING RETARDING LOOPS. Figure 1. Relay Box Antenna Connections. Relay Box Cable Connections

Kramer Electronics, Ltd.

HCE II Owner s Manual HDMI, and IR Extender over HDBaseT with 3D, 4K Support

National Park Service Photo. Utah 400 Series 1. Digital Routing Switcher.

Transcription:

Wireless Solar Monitoring System. Operating Instructions KACO-display full of energy...

KACO-display provides high-technology monitoring of your valuable photovoltaic installation. It shows the desired output, actual output, and it sounds an alarm as soon as a disturbance occurs. KACO-display consists of two parts: KACO-adapter (transmitter) and the display (receiver). KACO-adapter is capable of wireless data transmission to the display, thus saving laborious cable routing. In addition, it allows for use of several displays simultaneously in different locations. Depending on the version of KACO-display all parts of the solar module can be monitored. Data is processed in the display and shown in various display modes. Startup Install the KACO-adapter (transmitter) Switch on the KACO-display Adjust your settings on the KACO-display KACO-adapter Inverter Set-up Connect KACO-adapter to a blueplanet inverter by means of the enclosed data cable. Up to max. 4 blueplanet devices can be connected to KACO-adapter. 4 PS/2 receptacles are provided in the KACO-adapter, and a sub-d port (RS 232) interface is provided in the KACO inverter. The cable connected to KACO-adapter recognizes the inverter type being used. Make sure that KACO-adapter is close to the solar inverters and plug it into a wall outlet. Please test the location in advance to ensure that the transmitter can operate free from disturbances (you can check this by testing the signals/messages received by KACO-display. A data cable is enclosed with each KACO-display. If more than one inverter is to be connected to the monitoring system you will need the corresponding number of additional data cables. KACO-display Settings To access the Settings menu you must open the KACO-display as follows: Loosen the four stainless-steel screws located on each corner of the KACO-display cover plate by manually turning them left. Inside the device you will find three keys designated -, MENU, and +. Press the MENU key. Select the desired menu item by pressing or +. Press the MENU key to access this menu item. Use the + and - keys to change a value as desired. To confirm a selected item or entered value, press the MENU key. Overview of the Set menu: Menu item Options Explanation Default setting Illumination Always On - The display is illuminated for 120 120s Always Off 120 seconds Automatic seconds after knocking on the display screen. - Time-depending control (see explanation below) Display Automatic On - Changes the display at certain Off Off intervals - Toggle function (possible at any time by knocking on the display) Inverter blueplanet 2901xi blueplanet 3601xi - Inverter type - Only used to scale the display - Displays the daily curve of the blueplanet 4500 Operating Instructions 1

Rated Power* Transmitter IDs Location Time / Hour * Change meter Transmitter IDs: KACO-adapter WR 0-9 North Central South Hour Date AM / PM Clear daily meter Clear total meter Change total meter 4 inverters - Rated grid-feeding capacity of the complete installation in W - KACO-adapter for inverters Choose your location from the state list below AM/PM - Summer time / Winter time 5000 0 Central To ensure that the results are displayed correctly, it is vital that the time/hour, metering factor and rated power of your photovoltaic installation be entered correctly. North WA, SD, MN, IA, WE, MI, VT, NY, NH, MA, RI, CT, ME, AK, OR, ID, MT, WY Central NJ, PA, DE, MD, VA, KY, IN, OK, AR, MO, KS, NE, CO, UT, NV, NM, NC, WV, OH, TN, IL, CA South TX, LA, MS, AL, GA, SC, FL, HI, AZ The metering factor is printed on the grid-feeding meter. The rated power is shown on the invoice of your installation. If necessary, your supplier will provide you with this information. Automatic display illumination If the automatic display illumination is activated KACO-display will switch the display illumination ON and OFF at the following times: 00:00-06:00 OFF 06:00-09:00 ON 09:00-17:00 OFF 17:00-00:00 ON In general, you can enable the display illumination for 2 minutes by tapping the display screen. The brightness can be controlled with the rotary switch of the power supply. Please use the values of 7.5V, 9V or 12V. KACO-display can now be mounted on the wall. To do this: 1. Drill through any of the pre-bored holes in the back of the plastic housing. 2. Fasten the KACO-display to the wall. 3. Close the housing again by securely re-fastening the four stainless-steel screws. Operation and displays Changing from one display to another is done easily by tapping the display screen. The illumination is automatically switched on for 2 minutes after each change. To protect your data the recorded values are stored in a buffer memory. In this way, data will not be lost even in the event of a power failure. If any disturbances occur, KACO-display will send an alarm message. Operating Instructions 2

The expected total yield will be calculated from the plant s indicated nominal capacity and the date. The calculation is based on a sunny day, i.e. the actual insolation on the respective day will not be taken into account. The calculated nominal curve is drawn as a line, whereas the fed-in daily capacity is shown as a continuous area. This gives you a full overview of your PV installation s output at a glance. Available Displays 1. PV installation s total daily yield curve & total grid-feeding capacity Desired (nominal) curve Date & Hour Daily yield & total yield Receiving level 2. Individual inverter grid-feeding capacity & total daily yield curve Desired (nominal) curve Date & Hour Daily yield & total yield Receiving level/intensity 3. Individual inverters current grid-feeding capacity & daily yield curves Hour Receiving level 4. Yesterday daily yield sum & curve Desired (nominal) curve Date preceding day Daily yield & total yield 5. Individual inverter values table Grid-feeding capacity Generator voltage Grid voltage Device temperature 6. Overview of alarms of the current day & preceding day (only if an alarm was triggered today or yesterday) Check plant/installation No data received In the event of faults an error message appears automatically at the lower left of the display in the form of a bell symbol. The alarm symbol will stop flashing if the user views and checks the list of alarms. The alarm symbol continues to be shown until the alarm list no longer includes an alarm this is usually the case after two days (provided that no new alarm has been triggered). An antenna symbol is shown at the lower left of the display. To the right of this symbol the level of the received signal is shown in a bar graph. The symbol will flash if the reception of the signal is poor. Instead of values, such as the grid-feeding capacity, etc., the following messages may also appear to indicate malfunctions or disturbances: Alarm message Flashing line cursor Line cursor Antenna symbol Description KACO-adapter is connected but the cable is not plugged in. Received faulty value (very rare error) No reception of a value for 2 minutes Operating Instructions 3

List of alarms Alarm message Description Possible causes Check plant/installation Reply not received by all the connected inverters This alarm will be triggered after approx. 3 minutes, if an inverter feeds more than 300W whereas another inverter feeds only 0W. No data received KACO -display does not receive any data from KACO - adapter The wireless connection is interrupted. This message will be created after approx. 2 minutes. A warning sound will be returned if no connection is established for approx. 6 minutes. We wish you success and the best solar yields with your KACO-display! Accessories (optional) KACO-relais Radio-controlled relay, for extended transmission ranges between KACO-adapter and KACO-display. Max. 9 relays are possible. Due to the transmission capacity stipulated by law, it may be necessary to extend the transmission range by means of KACO -relais. For further questions about accessories, contact your distributor. Technical data KACO-display Included with delivery Display, adapter, operating instructions Power supply Mains adapter 230 V AC, 12 V= Measuring interval 8 minutes for the display of a curve Date / Hour Integrated, adjustable via internal keys, battery-buffer of clock: approx. 1 week Power consumption 0.3 W - 3 W, depending on illumination intensity Operating conditions -10 C to 50 C, for dry rooms only Dimensions 240 x 130 x 61 [mm] Radio communication 433.92 MHz RF approval EN 300 220, EN 301 489 & EN 60950 European Conformity CE Mark KACO -adapter Inverter Set Included with delivery Transmitter for connection to max. 4 KACO blueplanet inverters; screwdrivers, operating instructions Power supply 230 V AC Power consumption 0.5 W 0.75 W Connections 4x PS/2 socket for connection to max. 4 blueplanet inverters via RS232 Transmitter range 5-30 m, depending on local conditions Operating conditions 0 C to 55 C, for dry rooms only Dimensions 110 x 65 x 60 [mm] Technical specifications subject to change at any time and without notice. Guarantee and Service Blueplanet grants a guarantee of two years on KACO-display, starting from the date of shipment from KACO. During this time, guarantees the proper function of the devices and free repair of issues that arise due to manufacturer defects. Should your device show a defect or malfunction during the guarantee period, please contact your specialist dealer or, respectively, your installation expert, or notify KACO directly. Operating Instructions 4

Guarantee claims shall be excluded in the following cases: Use of the device for other than the intended use (normal use). Improper use and installation that does not comply with the required standards Improper operation. Manipulation of the device or makeshift repairs by the customer Influence of foreign objects or Act of God (lightning, over voltage, storm, fire) Non-adherence to the relevant safety instructions (NEC codes, UL, etc.). Transport damage All guarantee claims shall be handled at the premises of To this end, return transport should be sent, as far as possible, in the original or an equivalent packaging. Guarantee claims shall only be compensated by KACO if the damaged device is returned to KACO together with a copy of the invoice issued to the consumer by the specialist dealer. The model number on the device must be fully legible. In the event of noncompliance KACO reserves the right to deny guarantee services. The warranty period for a replacement unit shall be six months from original shipping date. Service High quality and longevity of our products always have been of central importance for us. Our more than 60 years of experience in the field of development and production support this philosophy. Despite all these quality-assuring measures, however, in very rare cases disturbances may occur. will offer a maximum of assistance if one of these cases should arise. will take every effort to remedy any defects quickly and without unnecessary bureaucracy. Please contact our service department directly and someone will help you immediately. Our product line: PHOTOVOLTAIC INVERTERS FREQUENCY CONVERTERS DC / DC CONVERTERS CHARGING RECTIFIERS POWER SUPPLIES PROTECTED DC VOLTAGE SUPPLIES EMERGENCY POWER SYSTEMS USV - INSTALLATIONS Operating Instructions 5