Cat.6 4 Pair UTP Cable

Similar documents
DINTEK LAN Cabling Systems

Frequency ASRL(db) Attenuation Max. NEXT Power Sum (MHz) Minimum db/100m db/1000ft Minimum db/100m Minimum db/100m

CATEGORY 6 CABLING SOLUTIONS

STRUCTURED CABLING SYSTEMS (SCS)

Description: Pair Color Code Chart: Pair Color Chart 1 Brown White Brown 2 Orange White Orange 3 Green White Green 4 Blue White Blue.

CATEGORY 5e CABLING SOLUTIONS

CATEGORY 6A CABLING SOLUTIONS

CATEGORY 6A CABLING SOLUTIONS

STRUCTURED CABLING SOLUTIONS

TB806AUX Class E A / Cat.6A UTP Keystone Jack (Auto press-fit)

Copper Solution Contents Cabinets Fiber Optic Solution

PREMIUM 5e F/UTP PRODUCTS

Dimensions. Electrical Specifications. Environmental Specifications. General Specifications. Mechanical Specifications.

Tender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab*

Clarity. Advanced solutions for 10 Gig, Category 6 and 5e copper connectivity PRODUCT SOLUTION GUIDE EXPERTISE. TECHNOLOGY. SOLUTIONS.

Compact Module. Category 6 FTP Cabling System


Multi-Media Installation Guide

Pre-terminated cabling system Modular cassette technology with 6x RJ45 C6 A ports

...Infinite Ways to Link...

Infinite ways to link... Solution Catalog

INFRASTONE BLACKSTONE 10G 6A(U/UTP) Europe, Middle East and Africa regions UNLIMITED USAGE 1

ENTERPRISE COPPER SOLUTIONS

HARTING Ethernet cabling cables and connectors, 4 wire

SHIELDED DIGITAL CABLES (1249C SERIES)

About Nexans 3. About Berk-Tek 4. LANmark-1000 Cat 6 UTP 5. LANmark-1000 Category 6 Plenum 6. LANmark-1000 Category 6 Riser 11

NCB-C6SGRYR M Category 6 STP Solid Cord. Specification. Doc. Version: /09/30

Magic Patch Patch Leads & Accessories

System List. Structured Cabling System. In-Building RF Solution. Shield/Unshield 4pr Cable. Patch Panel. Multi-pair Cable. Patch Cord.

PATCH CORDS, PLUGS & CABLES

August " BLANK PATCH PANEL FOR STP KEYSTONE JACKS. 19" PATCH PANEL - 24x STP CAT6A PORTS 19" BLANK PATCH PANEL FOR STP KEYSTONE JACKS

APPLIANCES /// MTA, CST-100 II AND SL-156 CONNECTORS. CONNECTORS/ APPLIANCES MTA, CST-100 II and SL-156 Connectors

HighBand 25. TrueNet Category 6 Solutions

MIDDLESEX COUNTY COLLEGE WIRE AND CABLE NETWORK REQUIREMENTS BH, CB, CH, ED, MH, LH, Camera Project

FLAT AND ROUND CABLE PRODUCT DESCRIPTION DESIGN ADVANTAGES. IDC Systems Cable

About Nexans 3. About Berk-Tek 4. Hyper Plus 5e Cat 5e UTP 5. HyperPlus 5e Plenum 6. Hyper Plus 5e Riser 10. HyperPlus 5e Patch 14


Ultra Small Surface Mount Coaxial Connectors - Low Profile 1.9mm or 2.4mm Mated Height

Class E A / Cat.6A Screened Coupler

Product information 19" 1U HD Patch Panel 48xRJ45/s, Cat. 6A, gray, fully populated

10G 6A F/UTP SYSTEM PRODUCTS 10G 6A F/UTP

GIGALAN CAT.6 U/UTP 23AWGx4P - LSZH (EXP)

TB876BSX-3WH Class E A / Cat.6A STP Keystone Jack (Auto press-fit)

LCS 2 RJ 45 Cat. 6A HD panels and units

CAT 6 Data Wiring System Connectors

GIGALAN AUGMENTED CABLE CAT6A F/UTP 23AWGX4P LSZH

3M Supported Applications Map 100,000 (2005) Single-mode. Fiber. Multimode. Fiber. Copper

CAT 6 Data Wiring System Connectors

MX5-F(XX)... Flat MAX module, T568A/B, rear strain relief cap

CAT5E NETWORK PATCH LEADS

LCS2 Cat. 6 RJ 45 Patch panels and units

SMART CLASSix 24/48 UTP Patch Panels -

GenSPEED 10 MTP Category 6A Cable An Unshielded 6A Cable with Superior Protection Against Alien Crosstalk

Structured Cabling System. Leading Solution

COLORED CATEGORY 5e BULK CABLE, SOLID-CONDUCTOR PATCH CABLE, & CATEGORY 5e BACKBONE CABLE

MCX Miniature Coaxial Connectors

GenSPEED Category 5e Cables 3

LEGRAND CABLING SYSTEM 2 PERFORMANCE FROM TECHNICAL ROOM TO WORKSTATION

RJ45FC6-BLU. Base Data. Category 6 modular keystone jack - Blue - 1/bag. Article Number: Part No. RJ45FC6-BLU. Type RJ45FC6. Color.

VERICOM GLOBAL SOLUTIONS Knoxville, Tennessee

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

Structured Cabling Introduction & Installation Guide

Coastal Carolina University RE-BID WILLIAMS BRICE RENOVATION AND REPAIR October 19, 2018 Construction Documents

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017

Detailed Specifications & Technical Data

Non Magnetic Connectors

Detailed Specifications & Technical Data

SECTION COMMUNICATIONS HORIZONTAL CABLING

Horizontal or Vertical PCB contacts Bulk Packaging LED colour - Red, Green, Yellow or Blue combinations. Ordering Codes

HDBT Installation Guide

75 Ohm BNC Male Connector Crimp/Solder Attachment for PE-B159, 1855A, Mini 59

FUTURE PROOF YOUR CONNECTIONS

Stainless Steel SMA Connectors Product Catalog

ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES

Solarstar Electronics Industrial Co.,Ltd. 3/F,58,Junxin Rd.,Guanlan,Longhua,Shenzhen,China

6-Connector- Channel-Link Class E A (STP)

Content BULK CABLES VIDEO CABLES AUDIO CABLES EXTENDERS USB CABLES ETHERNET CABLES VIDEO BALUNS CONNECTORS ADAPTERS PATCH PANELS & WALLPLATES TOOLS

Connect with the industry s best CAT6 and CAT5e channel solutions!

Ethernet Series. Etherplug Etherlink V Etherlink V Specialty Connectors Specifi cations...

MTA, CST-100 II, SL-156 and AMP Economy Power (EP) Connectors. NOT the LATEST REVISION

10G 6A UTP SYSTEM PRODUCTS 10G 6A UTP

European Product Catalog2009 AMP NETCONNECT Building Networks

75 Ohm N Male Connector Crimp/Solder Attachment for RG6

BUS UNITRONIC BUS CAN

SMART CLASSix 48 UTP Patch Panels (with patching switches) -

Professionally Install Products Right the First Time. TOOL-CRIMP Radial Linear compression tool for BNC, F & RCA connectors

Coaxial Cable Termination

HELLERMANNTYTON DESCRIPTION DIMENSIONS PKG. PART NO. (HXWXD) QTY. RE18 Residential Enclosure Base: 18 H x 14.1 W x 4 D 1 Cover: 19.5 H x 15.

technicalreport MegaLine Connect100 Class E A links over 100 metres in length Data communication technology 09/2018 Classic structure 2-connector link

Category 6 Solutions

SECTION 7 -- CROSS-CONNECT SYSTEMS

QUEST C6 SOLUTIONS CAT 6 CONNECTIVITY PRODUCTS LAN CONNECTIVITY

onlinecomponents.com

BTNS TM. FTP Compact Module

L-com. We Invest In Training So You Get Expert Advice. FREE Gift CONNECTIVITY PRODUCTS

Simple View TM. From the beginning to the end. We leave nothing out when it comes to your satisfaction.

Detailed Specifications & Technical Data

Product Description. Product Specifications. Technical Specifications. Construction and Dimensions. Conductor: Insulation: Color Chart 1:

Combining Value and Performance Like No One Else

Part Number: 7940A Cat 6 DataTuff, (4 pr) 23 AW G Solid BC, PO/PVC, EtherNet/IP, CMR, CMX-Outdoor

Transcription:

4 Pair UTP Cable Application: Voice Fast Ethernet(IEEE802.3u) VgAnyLAN(IEEE 802.12) Token Ring(IEEE 802.5) TPPMD(ANSI X3T9.5) BaseT Ethernet(IEEE 802.5) 155/622 Mbps 1.2/ 2.4 Gbps ATM 0BaseT Ethernet 550 MHz Broadband video Industry Standard: UL, ETL Verified TIA/EIA 568B.21 ISO/IEC 11801 EN 50173 P/N Description Jacket Color Std Pkg Qty Cable Data: No. of Pairs:4 Jacket Color:Gray Insulation Thickness: 0.33mm Nom.O.D.:6.5mm Flame Rating:CM Transmission quality verified up to 250MHz Product Electrical Characteristics: Impedance:±15 ohms Mutual Capacitance, max. nf/ m: 5.6 DC Resistance, max. Ohms/ m: 9.38 Capacitance Unbalance(Pair to Ground): 330pf/ m max. Contents Cat.5e Telecom Block Outlet 110104001, 4P, UTP, 24AWG, Solid PVC Gray 305M/reel in a box Management 110104004, 4P, UTP, 24AWG, PVC Solid For LSZH requirements, please contact us. Gray 305M/ Pull box Fiber Optic Frequency Attenuation Max. NEXT Power Sum EFLEXT (MHz) db/m db/m Minimum db/m (db/ m) 1 4 10 2.0 3.8 6.0 74.3 65.3 59.3 72.3 63.3 57.3 67.0 55.0 46.8 Cabinets 16 20 31.25 62.5 7.6 8.5 10.7 15.5 56.2 54.8 51.9 47.4 54.2 52.8 49.9 45.4 42.7 40.8 36.9 30.9 200 250 19.9 29.2 33.0 44.3 39.8 38.3 42.3 37.8 36.3 26.8 20.8 18.8 Standard www.dintek.com.tw 3

Contents Fiber Optic Telecom Management Outlet Cat.5e Cabinets Block 4Standard UTP Patch Cord Application: Voice Fast Ethernet(IEEE802.3u) VgAnyLAN(IEEE 802.12) Token Ring(IEEE 802.5) TPPMD(ANSI X3T9.5) BaseT Ethernet(IEEE 802.5) 155/622 Mbps 1.2/ 2.4 Gbps ATM 0BaseT Ethernet 550 MHz Broadband video Industry Standard: UL, ETL Verified TIA/EIA 568B.21 ISO/IEC 11801 EN 50173 P/N Description Length(M) Color Std Pkg Qty 120104032 4 pair UTP patch cord 1 Gray 10 120104038 4 pair UTP patch cord 2 Gray 10 120104044 4 pair UTP patch cord 3 Gray 10 120104051 4 pair UTP patch cord 5 Gray 10 unshielded RJ45 plug To meets EIA/TIA568B.21 performance. Specifications: Contact Material: Phosphor Bronze Contact Plating: 50u Gold plated Over u Nickel Plated. Contact Resistance: 10 milli ohms Max. Housing Material: Polycarbonate Operation Temperature: 40 C~+70 C P/N Description Std Pkg Qty 150188017 150188018 150188027 150188028 RJ45 plug for unshielded stranded wire 2624AWG 2 prong, 2 pieces construction RJ45 plug for unshielded stranded wire 2624AWG 2 prong RJ45 plug for unshielded solid wire 2624AWG 3 prong RJ45 plug for unshielded solid wire 2624AWG 3 prong, 2 pieces construction Product Description: Molded boots prevent pin from bending and cables from kinking Fully tested to meet TIA/EIA568B.21 Category 6 requirements Category 6 stranded 24AWG wires provides maximum flexibility ETL verified to EIA/ TIA568B specifications UL listed Wiring: T568B Mechanical: Plug Dimensions: Meets F.C.C standard. Durability: 750 cycles min.

Standard Unshielded Patch Panel 110 Enhanced Patch Panel: High performance, exceeds TIA/EIA 568B.21 Category 6 channel link requirements 110 and Krone dual type IDC termination 19 24 port patch panel, 1U size & 48 port panel, 2U size Accepts 2226 AWG, stranded or solid wire Wiring:T568A/ B Optional rear cable management IDC connector with large spacer for each pair to improve crosstalk Highlow contact design to improve transmission performance Compliant Press fit IDC connector terminal for high frequency application Contents Cat.5e Telecom Block P/N Description Std. Ctn. Qty Outlet 140204001 140204003 149900001 19 110/ krone dual type Patch Panel 24 ports, 1U size 19 110/ krone dual type Patch Panel 48 ports, 2U size 19 Rear cable management 25 10 45 Management Fiber Optic Installing the wire management Step 1. Align the tongue of the minder with the corresponding groove on the patch panel and insert it into the groove. Step 2. After installing two jacks, use a tie wrap to attach their wires to the wire manager. Do not over tighten the tie wrap! It crushes the wires. Continue this until all the jacks have been installed. Cabinets www.dintek.com.tw 5

Contents Fiber Optic Telecom Management Outlet Cat.5e Cabinets Block 6Standard Keystone Jack Industry Standard: UL, listed Meets FCC parts 68 ANSI/TIA/ EIA568B ISO/IEC 11801 ETL verified TIA/EIA T568B.21: channel link transmission performance Mechanical: Plug insertion life:750 cycle min. Plug retention force:30 lbs min. 130504002 130504003 P/N Description Std Pkg Qty Std Ctn Qty 110/ Krone horizontal type Keystone Jack, T568A/ B 110/ Krone vertical type Keystone Jack, T568A/ B Electrical: Current rating:1.5 Amps Insulation resistance:500megaohms min. Contact resistance:20 Milliohms max. DC resistance:0.1 ohms max. Data transmission rates up to 250Mbps Physicals: IDC connector accept 2226 AWG solid wire Jack wiring:50 u gold plated over u nickel Housing:High impact flame retardant plastic UL94V0 rated IDC connector suitable for 110 punch down and Krone tool Channel passive performance test configuration ETL & 3P verified 400 400

High Quality 110 CrossConnect Block Exceeds TIA/EIA 568B.21 category 6 standard Ideal for use in cross connections and consolidation point applications Highly visible colorcoded wiring slots for easy wiring Mounts to standard TIA/EIA 19 racks Available with or without mounting legs for a variety of mounting options Can be terminated with single or multiple position punch down tools Contents P/N Description Std. Ctn. Qty 180206 Wiring blocks w/o mounting legs, w/ 50pair Large space of each pair to improve crosstalk Cat.5e Telecom Block 180202003 Wiring blocks w/o mounting legs, w/ pair Outlet 180204001 Wiring blocks w/o mounting legs, w/ 300pair Management 180104 Wiring blocks w/mounting legs, w/ 50pair Fiber Optic 180102004 Wiring blocks w/mounting legs, w/ pair Cabinets 180104001 Wiring blocks w/mounting legs, w/ 300pair 180403003 connecting blocks 4 pair Colorcoded design for easy wiring Standard www.dintek.com.tw 7

Contents Fiber Optic Telecom Management Outlet Cat.5e Cabinets Block 8Standard 4 Pair SSTP Cable Application: Product Electrical Characteristics: Voice Impedance:±15 ohms Fast Ethernet(IEEE802.3u) Mutual Capacitance: nom. 13.6pf/ft VgAnyLAN(IEEE 802.12) DC Resistance: max. 6.8ohm/m at 20 C Token Ring(IEEE 802.5) Voltage rating: 30V TPPMD(ANSI X3T9.5) Rated temperature: 60 C BaseT Ethernet(IEEE 802.5) 155/622 Mbps 1.2/ 2.4 Gbps ATM Cable Data: 0BaseT Ethernet No. of Pairs:4 pair 550 MHz Broadband video Size of conductor: 23AWG (solid anneal copper wire) Industry Standard: Overall Diameter:7.4±0.3mm According to UL444 Communications Cables, UL AWM style 2835 Individual Shielding: Aluminumfoil laminated tape. TIA/EIA 568B.21 Jacket material: PVC or LSZH, flame retardant and/or CM grade. P/N Description Jacket Std Pkg Qty 110704001 305m 4P SSTP 23AWG solid PVC (1,000ft) cable /reel 110704002 305m 4P SSTP 23AWG solid LSZH (1,000ft) cable /reel Frequency Attenuation Max. NEXT Power Sum EFLEXT PSELFEXT Return Loss (MHz) db/m db/m Min. db/m (db/ m) (db/ m) (db/ m) 1 2.0 74.3 72.3 67.8 64.8 20.0 4 3.8 65.3 63.3 55.7 52.7 23.0 8 5.3 60.8 58.8 49.7 46.7 24.5 10 6.0 59.3 57.3 47.8 44.8 25.0 16 7.6 56.3 54.3 43.7 40.7 25.0 20 8.5 54.8 52.8 41.7 38.7 25.0 25 9.5 53.4 51.4 39.8 36.8 24.3 31.25 10.7 51.9 49.9 37.9 34.9 23.6 62.5 15.4 47.4 45.4 31.8 28.8 21.5 19.9 44.3 42.3 27.8 24.8 20.1 200 28.98 39.8 37.8 21.7 18.7 18.0 250 32.85 38.4 36.4 19.8 16.8 17.3

SSTP Patch Cord Application: Voice Fast Ethernet(IEEE802.3u) VgAnyLAN(IEEE 802.12) Token Ring(IEEE 802.5) TPPMD(ANSI X3T9.5) BaseT Ethernet(IEEE 802.5) 155/622 Mbps 1.2/ 2.4 Gbps ATM 0BaseT Ethernet 550 MHz Broadband video Cable Data: No. of pairs: 4 Size of conductor: 26AWG (Stranded Anneal copper wire) Dielectric material: Foamed P.E Diameter of Dielectric core: 1.0±0.05mm Individual Shielding:Aluminumfoil laminated tape Overall Shielding: Tinned copper wire braiding, normal with min. 65% coverage. Jacket: PVC, flame retardant CM grade O.D.: 5.7±0.2mm P/N Description Length(M) Color Std Pkg Qty 120104022 4P SSTP patch cord 1 Gray 10 120104023 4P SSTP patch cord 2 Gray 10 120104024 4P SSTP patch cord 3 Gray 10 120104025 4P SSTP patch cord 5 Gray 10 For special requirements please contact us Industry Standard: According to UL444 Communication cables, UL AWM style 2835 TIA/EIA 568B.21 ISO/IEC 11801 Product Description: Molded boots prevent pin from bending and cables from kinking Fully tested to meet TIA/EIA568B.21 category 6 requirements 50u gold plating on RJ45 plug contacts. Durability: 750 cycles min. Wiring: T568B Contents Cat.5e Telecom Block Outlet Management Fiber Optic shielded RJ45 plug To meets EIA/TIA568B.21 performance. Specifications: Mechanical: Contact Material: Phosphor Bronze Plug Dimensions: Meet F.C.C. Standard Contact Plating: 50u Gold plated Over u Nickel Plated. Durability: 750 cycles min. Contact Resistance: 10 milli ohms Max. Housing Material: Polycarbonate Operation Temperature: 40 C~+70 C P/N Description Std Pkg Qty Cabinets 150188022 RJ45 Plug for shielded stranded wire 2624AWG (2 Prong) 2 pieces construction Standard 150188029 RJ45 Plug for solid wire 2624AWG (3 Prong) 2 pieces construction www.dintek.com.tw 9

Contents Fiber Optic Telecom Management Outlet Cat.5e Cabinets Block Standard Fully Shielded Patch Panel Features: High performance, meets all channel link requirements specifed in TIA/EIA568B.21 % shielded for complete EMI/RFI protection 19 24port patch panel, 1U size. 110 and Krone dual type IDC termination Accepts 2226AWG, Stranded or solid wire Wiring: T568A/B Electrical: Insulation resistance: 10 Mega ohms min. Dielectric with standing voltage: 1,000 Volts, RMS, 60Hz, 1min. Contact resistance: 20 milli ohms max. Current rating: 1.5 AMPS at 20 C P/N Description Std. Ctn. Qty 140204004 8 in 1 module 19 110 type fully shielded patch panel 24 ports, 1U size 9 position IDC termination, includes the ninth slot for the drain wire. Physical: Housing: Highimpact, flameretardant plastic, UL94V0 rated spring wire/contact blades. Material: Phosphor Bronze Alloy. Plating: 24 Carat hard gold 50u plating thickness over u nickel. Sheel: Brass alloy plated with u nickel. Plate: SPCCSD 16G. Mechanical: Total mating force: 800 grams for a 8 wire leads min. Retention: 30 lbs min between the jack and plug. Insertion/Extraction life: 750 cycles minimum. Number of IDC terminations: 200 cycles minimum. 10 Grounding lock 10

Fully Shielded Patch Panel instruction Contents Step 1. Strip approximately 7.7cm of the jacket from the cable. Be sure that the foil and/or braid remains intact. Step 2. For cable with foil but no braid: Fold the foil shield back over the jacket of the cable. For braided cable: Slide the braid back over the wire, wrap jacket and,if there is a drain wire,wrap it around the braid close to the fold at least 3 times (See Step 5 for alternative drain wire instruction) Step 3. For cable with foil but no braid: Wrap the drain wire around the foil shield. Do not wrap the drain wire more than 1.3cm from the fold in the foil shield. (See step 5 for alternative drain wire instruction). For braided cable: Unwrap the foil that extends beyond the jacket from each pair and cut it off. Cat.5e Telecom Block Outlet Management Step 6. Fasten the cable to the strain relief tabs with cable ties and trim off the excess cable tie. Step 5. Instead of wrapping the drain wire around the foil shield, the drain wire may be inserted into the ninth slot (the slot with no color code) on the IDC connecting block as shown. Step 4. For braided cables: Insert the cable though the ground clip as shown. Fiber Optic Cabinets Step 7. Tighten the ground clip screw until it reaches the bottom. Ensure that there is no foil in contact with the ground clip. Step 8. Press the wires into the IDC connecting blocks according to the color code on the blocks. Punch the wires down with an impact tool in order to terminate them. Do not forget to teminate the drain wire if it has been inserted into the ninth slot. Step 9. Slide the rear cover into place and lock it into position by clasping the two plastic buttons. Attach a ground wire from the ground lug to a grounding Standard www.dintek.com.tw 11

Contents Fiber Optic Telecom Management Outlet Cat.5e Cabinets Block Standard 130504006 130504007 Fully Shielded Keystone Jack Transmission performance: Meets all cat.6 channel performance requirements specified in TIA/EIA568B.21 Mechanical: Total mating force: 800 grams for a 8 wire leads minimum. Retention: 30lbs min between the jack and plug. Insertion/Extraction life: 750 cycles minmum. Number of IDC terminations:200 cycles minimum. P/N Description Std Pkg Qty Std Ctn Qty 110/ Krone horizontal type fully shielded keystone Jack, T568A/ B 110/ Krone vertical type fully shielded keystone Jack, T568A/ B Step 1. Preparing the Jack for termination Electrical: Electrical insulation resistance: 10 mega ohms min. Dielectric with standing voltage: 1,000 V, RMS, 60Hz, 1min. Contact resistance: 20 milli ohms max. Current rating: 1.5 AMPS at 20 C Physical: Housing: Highimpact, flameretardant plastic, UL94V0 rated. Spring wire/contact blades: Material: Phosphor Bronze alloy. Plateing: 24 Carat hard gold (50u plating thickness) over u nickel. Shell: Brass alloy plated with u nickel. Rightangle fully shielded keystone jack installion step ground wire ground wire 200 200 Step 3. Completing the termination ground wire Step 4. Completing the Shield ground wire ground wire Step 2. Terminating the Jack Step 5. Adding the Strain Relief 12