sequenza 1000/1250 al manuale di istruzioni instruction manual 1^ edizione, ottobre st edition october 1996

Similar documents
coemar nat pc 1200 HMI

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

USER MANUAL. DE-1 Police-light. CAUTION! Keep this device away from rain and moisture! Unplug mains lead before opening the housing!

DMX LED light effect with 4 lenses

ENG X R 7 W A S H Show division Show

Led Dynamic DMX Tri Curtain Manual

SUPER LED F4.7 VW Vari-White INSTRUCTION MANUAL

LED MODULES READYLINE DL

USER MANUAL Table of Contents

180w led gobo moving USER MANUAL

Identification - electrical services

COLORtube EQ Controller

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

ORLAND SCAN PR PR LIGHTING LTD. Yingbin Road, Dashi Panyu, Guangzhou, China

Figure 1: Device components

Cyclo Series. user manual. MartinArchitectural

1. Before you Begin Introduction Setup Operation Technical Information Technical Specifications...

LED Spot 300W. Please read this user manual before your operation

LED Spot Light User Manual Model LS90 Big Dipper Laser Science And Technology Co., Ltd Please read this manual carefully before operating

Introduction Front Panel Functions Rear Panel Functions Precautions Placement & Ventilation... 5

2 Hour Electronic Boost Timer

LED-PAR200B USER MANUAL. COLORsplash 200B

LCB-320 LED COLORS 320X10MM DMX 16SEG

Edition Notes. Edition Notes. Trademarks CHAUVET is a registered trademark of CHAUVET & Sons, LLC. (d/b/a CHAUVET or Chauvet).

LED Techno Strobe RGB ST-4000RGB USER MANUAL

USER MANUAL. WARNING Read the instructions before using the machine. EN (Original Instruction) / 1704

120cm (4x36 Watt) incl. Splitter Instruction Manual

1. BEFORE YOU BEGIN INTRODUCTION SETUP... 7

1. BEFORE YOU BEGIN INTRODUCTION CONTROL FEATURES... 5 Additional Features... 5 PRODUCT OVERVIEW SETUP... 6

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

TABLE OF CONTENTS. 1. Before You Begin...3

Winmate Communication INC.

Features. High Brightness SMD LED Light source

SquareLED - Aura Bar & Matrix Beam Light 100

Ref. No.: LCB-48IP LED COLORUNIT 16X3W TRI DMX

CLF Manuals CLF Colour Par CLF Colour 12 Par CLF Colour Par 12 Version 1.0 November 2012 Version 1.0 1

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

1. Before You Begin... 3

LED Thunder S-150 Code 1097

TABLE OF CONTENTS. 1. Before you Begin Introduction Setup Operation Technical Information...

LED-BANK4 USER MANUAL. COLORbank 4

User Manual. 360W LED Moving Zoom KEEP THIS MANUAL FOR FUTURE NEEDS. 36pcs10W 4 in 1 RGBW LEDs

TABLE OF CONTENTS. Page 2 of 16 COLORband PiX IP User Manual (Rev. 1)

ACCLAIM. ZOOMSPOTS Operation Manual

SOFT LED 4 Vari-White INSTRUCTION MANUAL

Color Ground 12T 16 A USER MANUAL 5 APPENDIX 5.1 TROUBLE SHOOTING 5.2 MAINTENANCE LED MODULE. Version 1.0 SITUATION CAUSE ACTION 5 APPENDIX

Litile34 INSTALLATION MANUAL

Power Injector 1520 Series

Theatrik HUSH PAR. Blizzard Lighting, LLC Waukesha, WI USA Copyright (c) 2013

apple Service Source Apple Cinema HD Display 23" LCD (ADC) 11 April Apple Computer, Inc. All rights reserved.

Operation and Maintenance Guide Electric Needle Scalers

1. Before You Begin... 3

Hip Hop Activity Box. Instruction Manual. Hip Hop Activity Box 22875, October 2018 Copyright ROMPA Ltd

thinpar 38

TRF STEP-DOWN TRANSFORMER USER MANUAL

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA

Quick Reference Guide

TABLE OF CONTENTS. 1. Before you Begin... 3 What is Included... 3 Unpacking Instructions... 3 Text Conventions... 3 Icons... 3 Safety Notes...

1. Before You Begin... 3

Caution. Hanging the Screen:

TABLE OF CONTENTS. Page 2 of 12 MotionFaçade LED User Manual (Rev. 10)

414 P 1. DESCRIPTION AND TECHNICAL SPECIFICATIONS 2. LAY-OUT OF STANDARD SYSTEM INSTALLATION DIMENSIONS. Fig. 1. Fig. A

Valve Amplification Company

USER MANUAL FOR THE PANEL VIEWER

USER MANUAL Table of Contents

ACUBRITE 23 SS. Manual. Stainless Steel Chassis 23" LCD Display. Content

Philips CoralCare FAQ

CU103 User Manual. Contents

ORDER CODE: EQLED65 USER MANUAL

7 Day Digital Programmer 3 Channel Surface Mount

Index. Index. 1.0 Introduction...2 This Manual Operation Finger Lift Cable Lift Pneumatic Operation...

TABLE OF CONTENTS. Returns Contact Us Page 2 of 21 Intimidator Spot LED 450 User Manual Rev. 2

BROTHER, BROTHER & SONS

TABLE OF CONTENTS. Page 2 of 25 COLORband PiX-M User Manual (Rev. 1)

TeamWork Installation Guide

Gardner Liquid Color Standards Instruction Manual

Spectra Batten (Order code: LEDJ95)

VPM2. Operation Manual

USER MANUAL. GOLDMUND LOGOS 1N-2N SPEAKER SYSTEM Active Speaker

TABLE OF CONTENTS. Page 2 of 21 COLORband PiX User Manual Rev. 6

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

TABLE OF CONTENTS. Page 2 of 17 COLORstrip User Manual (Rev. 5)

TABLE OF CONTENTS. Document Information. 1. Before you Begin Introduction Setup Operation... 8

Pendant Light Fitting IEC Series 6470/2

10.4" LCD Monitor with Aluminum Front Bezel YPM1040PHB

PLL1920M LED LCD Monitor

Operating instructions

Reference Manual. Notes 9/16 Series H

Litile34 OPERATION MANUAL

Product Manual. Designed and Manufactured in the UK by Optikinetics

ART 7 SERIES PROFESSIONAL ACTIVE SUBWOOFERS. a new generation of speakers is born and it s ready to rock audiences all over the world

TFX-950CM Stage Wash 950

Spectra Flood Q40. Exterior Fixture User Manual. Order code: LEDJ Version LEDJ284N - 15 Version

KingWash 7QX 7x40w,Zoom 5-60degree. User manual. Please read the instructions carefully before use TABLE OF CONTENTS

Manual placement system MPL3100. for BGA, CSP and Fine-Pitch components

Sirio 150 / 150DV. Code 02E010 - Sirio 150 Code 02E011 - Sirio 150DV OPERATING INSTRUCTIONS. COEF srl. Revision 1

10 PDUs 19 PDUs Zero-U PDUs

4-PROJECTOR BAR WITH 3 X 9W LEDS AND 1 X 1W FLASH LED USER GUIDE

In-Ceiling Electric Motorized Front Projection Screen Evanesce Series. User s Guide

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

Transcription:

manuale di istruzioni instruction manual 1^ edizione, ottobre 1996 1st edition october 1996 sequenza 1000/1250 al

sequenza 1 1000/1250al cod. 5092 sequenza 1000/1250 al/s cod. 5093 sequenza 1000/1250 al/a 305 mm 260 mm 360 mm 220 mm serial number date of purchase retailer address suburb capital city state tel./fax/ Please note in the space provided above the relative service information of the model and the retailer from whom you purchased your sequenza 1000/1250 al: This information will assist us in providing spare parts, repairs or in answering any technical enquiries with the utmost speed and accuracy. WARNING: the security of the fixture is granted only if these instructions are strictly followed; therefore it is absolutely necessary to keep this manual.

Index 1. Packaging 2.Lamp: installation and replacement 3.Installation 4.Electrical connection 5.Operation 6.Maintenance 7.Electrical schematic 8.Spare parts coemar authorised service centres worldwide

Congratulations on having purchased a new coemar product. You have ensured yourself of a fixture of the highest quality, both in the components and in the technology used. We renew our request for you to complete the service information. This information will assist in prompt and accurate advice from your coemar service centre (in case of problems encountered either during or subsequent to installation). 1. Packaging Following the instructions contained in this manual will ensure the maximum efficiency of this product for years to come. Open the packaging and ensure that no part of the equipment has suffered damage in transit. In case of damage to the equipment, contact the carrier immediately by telephone or fax, following this with formal notification in writing. packing list Ensure that the packaging contains the following items: 1 sequenza 1000/1250 al (complete with safety glass) 1 colour frame 1 L -shaped yoke 1 graduated fixing plate, complete with bolts and T- handle 2. Lamp: Installation lamp type and maintenance sequenza 1000/1250 al uses a linear halogen lamp of either 1000 or1250w The following lamps are available through the coemar distributor network: coemar cod. 105088 power 1000 w voltage 230 v luminous flux 26.000 lm colour temperature 3200 K base R7s coemar cod. 105082 power 1250 w voltage 230 v luminous flux 33.750 lm colour temperature 3200 K base R7s safety Attention Disconnect mains power before opening internals The fixture s internal temperature can reach 180 C after 5 minutes of operation, with a maximum peak of 200 C; ensure the lamp is cold prior to attempting removal. The fixture should be allowed to stand and cool for 10 minutes prior to opening for lamp replacement or internal inspection. lamp handling The lamp is quartz glass and must be handled with care. Follow the instructions included in the lamp s packaging. Do not touch the glass directly, use the tissue provided in the lamp box.

lamp access To gain access to the lamp, undo the locking mechanism at the top of the sequenza 1000/1250 al and by using a plane screwdriver, turn clockwise the security screw. The hinged front of the unit will open, together with the safety glass, allowing complete access to the lamp. Insert the lamp into the double-ended lampbase. Should you encounter any difficulty during this operation, DO NOT USE UNDUE FORCE. Check all components and repeat the procedure. closing the unit Carefully close the front of the sequenza 1000/1250 al. A sudden jarring impact may cause damage to the lamp filament or fixture. After installing the lamp reverse the procedure above to secure the hinged front 3. Installation Mounting the yoke Locate, in the packaging, the L -shaped yoke, the M5 bolt, the graduated fixing plate, and the T-handle. Assemble the yoke prior to mounting it to the housing. Slide the threaded M8 end of the T-handle through the untapped hole of the yoke (placing the smooth washer between yoke and T-handle), and affix the graduated fixing plate so that the markings are to the exterior, adjacent to the yoke. Open the front inspection lid of the sequenza 1000/1250 al and insert the M5 bolt in the lateral slot on the yoke fixing side. Now slide the yoke onto the guide located on the external side of the sequenza 1000/1250 al and connect and tighten the bolt to the yoke with a screwdriver. This tightening will result in the yoke sliding along its guide and seating itself correctly. Do not use undue force in this operation. assembling multiple units This procedure is similar to that of mounting the yoke. Open the front inspection lid of the sequenza 1000/1250 al and insert the M5 bolt into the lateral slot on the side of one of the sequenza 1000/1250 al to be joined. Slide the accessory joining piece (coemar cod. 5086) onto the guide, then connect and tighten the bolt. This tightening will result in the joining piece sliding along the guide and seating itself correctly. Do not use undue force in this operation. You can now connect the sequenza 1000/1250 al units together. Safety glass The sequenza 1000/1250 al has a tempered safety glass fitted as standard. This is useful in case a lamp ruptures, averting the risk of hot, falling glass. If necessary, it is possible to remove the safety glass by means of removing the 4 screws which fix the front housing. mounting accessories Each sequenza 1000/1250 al is supplied with a colour frame which has one serrated edge and which fits into the front housing. The serrated edge may be place to the top or to the bottom of the fixture, however is desired. The sequenza 1000/1250 al also has available an accessory barndoor which fits to the front of the unit.

lamp position Ensure that the sequenza 1000/1250 al is always operated with the lamp in the horizontal plane. Failure to do so will result in excessive overheating of the lamp, with a resultant dramatic decrease in lamp life. yoke adjustment The yoke has been designed to allow the sequenza 1000/1250 al to be easily adjusted to point upwards or downwards. vertical adjustment The sequenza 1000/1250 al should be operated with the vertical inclination not exceeding 45 towards the top and 90 towards the bottom, always maintaining the lamp in the horizontal plane. If using the assymmetrical version of the sequenza 1000/1250 al note that the brighter band of light may be placed at the top or the bottom, depending upon the desired effect. mounting The yoke of the sequenza 1000/1250 al is provided with three 10 mm holes. Use the hole closest to the edge when mounting a model 500, the central hole for a model 1000, and the hole closest to the bend in the yoke for mounting multiple units. Ensure that your mounting accessory is able to sustain the weight of the unit(s). installation The sequenza 1000/1250 al is designed for internal use, in ambient temperatures below 40 C. safety chain The use of a safety chain (coemar cod. 069), affixed to the sequenza 1000/1250 al and to the primary suspension point, is highly recommended in the case, however unlikely, that the suspension point should fail. The rear of the fixture is provided with a robust ring as an attachement point. risk of fire Each fixture produces heat and so should be mounted in a wellventilated position. Minimum distance from a flammable surface: 0,5 m. Minimum distance between the fixture and the object being illuminated: 1 m. 1 m 4. Electrical connection cabling The mains cable provided is thermally resistant, complying to the most recent international standards. It meets, or exceeds, the VDE and IEC norms: IEC 331, IEC 332 3C, CEI 20 35. N.B.: In case of cable replacement, similar cable, with comparable thermal resistance attributes, must be used exclusively (cable 3x1.5 ø, external ø10 mm, 300/500V, tested to 2KV, operating temperature -40 to +180 cod. COEMAR CV5309)

ATTENTION! In removing the outer sheath of the cable when replacing it or connecting plugs, be careful to not damage or remove the internal sheath for each conductor. attaching a plug Ensure that the plug you use is rated at a minimum of 5 Amps, with a suitable earth. It is absolutely necessary that the fixture be correctly earthed via the yellow/green earth wire. Connect the brown wire to the active, the blue wire to the neutral and the yellow/green wire to earth. Make sure all wires are securely attached. A good earth connection is vital for proper functioning of the fixture. Strict adherance to regulatory standards is strongly recommended. note: sequenza 1000/1250 al is able to operate at any standard mains voltage or frequency. A suitable lamp is the only requirement. testing Before mounting the unit in a permanent position, connect it to a fused outlet and test it for correct operation of the lamp. protection The use of a fuse rated at 6,3 A for a 1000w lamp and 10 A for a 1250w lamp, or the use of a thermal/magnetic circuit breaker for each sequenza 1000/1250 al, is highly recommended. Should the sequenza 1000/1250 al be operated via a dimming system, ensure that the dimmer is fitted with fused load protection. 5. Operation focusing Whilst focusing the unit, it is recommended that any colour gel be removed, and the lamp be dimmed so as to avoid the unit becoming hot and therefore difficult to manoeuvre. colour frame Every sequenza 1000/1250 al is supplied with a colour frame to suit gel of dimensions: 250mm x 295mm. We recommend the use of high-temperatue gel, often known as supergel.

6. Maintenance periodic cleaning The following periodic maintenance is highly recommended. Before attempting any of the following, ensure that the mains supply to the unit is disconnected. safety glass and reflector Even a fine layer of dust can reduce luminous output substantially. Regularly clean the reflector and glass using a soft cotton cloth dampened with a specialised cleaning solution. Replace the safety glass if there are any visible signs of damage, cracks, or deep scratches. air passages The air passages should be cleaned approximately every 6 weeks; the period for this cleaning will depend, of course, upon the conditions in which the unit is operating. Suitable inistruments for performing this type of maintenance are a brush and a common vacuum cleaner or an air compressor. lamp The lamp should be replaced if there is any observable damage or deformation due to heat. This will avoid the danger of the lamp exploding. electrical components Check all components for correct earth connection and the proper attachment of all connectors, refastening if necessary. mechanical components Periodically check all mechanical components and housing for physical damage, replacing them if necessary. 7. Electrical schematic N alimentazione/ main Ph blu/ blue giallo verde/ yellow green marrone/ brown 1000/1250 W 8. Spare parts All the components of the sequenza 1000/1250 al are available as spare parts from your authorised coemar service centre. Accurate description of the fixture, model number, and type will assist us in providing for your requirements in an efficient and effective manner.

coemar spa via Inghilterra 46042 Castelgoffredo (Mantova) Italy Tel. 0376/77521 Fax 0376/780657 coemar reserves the right to effect modifications without notification instruction manual sequenza 1 1000/1250al 1 st edition october 1996