Digital Temperature & Analog Sensor. Analog Input Port. Digital Port. Front

Similar documents
DPS Telecom Your Partners in Network Alarm Management

Kramer Electronics, Ltd. USER MANUAL VM-20HD. Dual 1:10 HD/SD SDI Distribution Amplifier

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher

SAPLING WIRED SYSTEM

Single sensor setup with NIVEL210

Model#: IN-MDRI3MF. Hardware User Manual. 3MP Indoor Mini Dome with Basic WDR, Fixed lens. (PoE) Ver. 2013/02/04

Model#: IN-DI2MIRF 2MP Indoor Dome with True Day/Night, IR, Basic WDR, Fixed lens

Automated Local Loop Test System

Intelligent Security and Fire Ltd

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

Weschler AMT Software for the Enhanced Version Transformer Advantage

TransitHound Cellphone Detector User Manual Version 1.3

FS1-X. Quick Start Guide. Overview. Frame Rate Conversion Option. Two Video Processors. Two Operating Modes

Video Server SED-2100R/S. Quick Installation Guide

SC-HD-2A HDMI Scaler & Audio Embedder / Extractor

DTA INSTALLATION PROCESS & USER GUIDE FOR SPECTRUM BUSINESS CUSTOMERS

SCALE & WEIGHT DISPLAYS

FS3. Quick Start Guide. Overview. FS3 Control

WECON LX3V-2PT2DA BD Board

Manual #: UMA1074 Rev. 2 October, Hall Research Technologies, Inc 1163 Warner Ave. Tustin, CA 92780

DM1624, DM1612, DM812


KD-VP800 RGBHV-to-Component Digital Video Scaler & Video Adapter

Kramer Electronics, Ltd.

Programmable Micro Remote LED Controller for RGB LED Strips - 12 or 24 VDC Part number: PMRC

Multicom Optical Return Path Receiver MUL HRPR 4B

MS2540 Current Loop Receiver with RS485 Communication

LX3V-2PT-BD User manual

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Long Range Ethernet Extender

Electronic converter for level transmitters MT03L Instructions manual

MultiMac SM. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

WECON LX3V-2PT-BD Module

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.0

TED Pro Energy Monitoring and Control System

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

Q516 HIGH RES AUDIO DELAY ORDERING OPTIONS SUPPORT OPTIONS MANAGEMENT AND CONTROL HIGH PRECISION AUDIO DELAY FOR MICRO SECOND ACCURACY

SBL /SBLG Series Wireless Clock

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

Omni Ultimate Quick Start Guide. 120V AC or 230V AC.

APPLICATION NOTE # Monitoring DTMF Digits Transmitted by a Phone

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.1

RSSL1:1-KuXER. Outdoor Unit (ODU) Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System. Mux/Tee. Coax cable

The Admiral Type 4 family of safety light curtains is the ideal solution for the protection of the majority of high-risk industrial applications.

Inputs and outputs. Connecting leads. Buzzer

SIL-2 8-Ch Analog Input Series Thermocouple, High Level, Low Level

Overview. Shipped in the Venue Vizion Package: Simplified Integration Process. Installation consists of 6 easy steps:

Off Site Maintenance Goes Mobile Electronic Cellular Time Switch

Process Transmitter RMA 422

MT03A Electronic converter for flow rate transmitters

Activity P27: Speed of Sound in Air (Sound Sensor)

Power Injector 1520 Series

In-Ceiling Electric Motorized Front Projection Screen Evanesce Series. User s Guide

HD Digital Set-Top Box Quick Start Guide

Installation Instructions

TeamWork Installation Guide

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

KODAK Video Monitor CFH-V10

Ocean Sensor Systems, Inc. Wave Staff III, OSSI With 0-5V & RS232 Output and A Self Grounding Coaxial Staff

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

FS4 Quick Start Guide

WECON LX3V-2TC2DA BD Board

i-repeater Control and monitor all your repeaters through the cloud Rackmount Wallmount

SV-LCD50. Installation and User Guide. Thin-Film Transistor (TFT) Liquid Crystal Display (LCD) Color Rear Vision Monitor. Version 1.

Data Acquisition Using LabVIEW

E3/DS3 Fibre Extender

DVISm. DVISm - Mini Digital Video Insertion System. Quick Start Guide. Patent Pending

VNS2200 Amplifier & Controller Installation Guide

Quick Start Guide Long Range Wireless 5x2 HDMI Matrix PRO Receiver

WECON LX3V-2TC-BD Module

Aurora Grid-Tie Installation Instructions (Model Number: PVI-3.0-OUTD-US-W) Revision 4.1

MXS Strada USER GUIDE

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

Data Acquisition Networks. Installing and Configuring the DM01 Hardware

HD Digital MPEG2 Encoder / QAM Modulator

Operating Instructions

1. Get support Attention Safety Caution Applications View Cameras on Screen (ex. HD TV or PC monitor) 3. Change Time Zone 5

AUTOMATIC VIDEO LOSS A/B SWITCH

Single cable multiswich programmer PC102W

Analog Output for the TSI DUSTTRAK Aerosol Monitor Model 8520

Multi-DC Power Distribution Box

VGA Extender over Single CAT 6 Cable with Audio Support. Model Extend both video and audio up to 1000 feet

SECURITY RECORDING 101

Vision Sensor Short Manual

Instruction Manual Model BlockUpconverter

GFT channel Time Interval Meter

Valcom Wired Digital Clock

LDG ALK-2 Two-Port Audio/Linear/Key Switch

UNDER TABLE 4X1 HDMI SWITCHER

Standard RS232 RS ma

Transmitter Interface Program

Optiflex Interactive Video System

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

Evolution Digital HD Set-Top Box Important Safety Instructions

Kramer Electronics, Ltd. USER MANUAL. Model: VP-12NHD. 1: UXGA / CAT5 Distributor

By CHANNEL VISION. Flush Mount Amplifier A0350

VGA Extender LR EXT-VGA-141LR. User s Manual

DB-VRC4H 4K HDMI Compact Video Wall Controller with 45 degree screen rotation

SECU-16. Specifications Power: Input Voltage 9-12V DC or AC Input Current Max 200mA. 8 2-wire inputs, Analog (0 5VDC) or Supervised

EDL8 Race Dash Manual Engine Management Systems

Transcription:

AVTECH Digital Temperature & Analog Sensor AVTECH s Digital Temperature & Analog Sensor monitors ambient indoor temperature and a connected 0 to 5 VDC analog sensor. This compact, light-weight sensor has operating ranges of -40º to 185º Fahrenheit (-40º to 85º Celsius) and 0 to 5 VDC; it maintains accuracy within +/- 2º C and +/- 0.075 volts. Digital Temperature & Analog Sensor Package Contents One (1) Digital Temperature & Analog Sensor One (1) 25' RJ-11 cable Digital Temperature & Analog Sensor Analog Input Port Digital Port Installation Note Front Install Your Digital Temperature & Analog Sensor Do not use this sensor in hazardous (classified) locations or life safety applications. Step 1: Mount your Digital Temperature & Analog Sensor. Locate the sensor where you wish to measure temperature. You may hang it from a nail, screw or hook through the flange hole, secure it with Velcro or simply place it on a flat surface. Step 2: Connect your Digital Temperature & Analog Sensor to Room Alert. 1. Run the built-in 25' cable back to your Room Alert or Wireless Sensor Hub. Try to avoid running it near large electromagnetic devices or fluorescent lights, which produce EMI that can interfere with the sensor s readings. 2. Connect the sensor to a digital sensor port on your Room Alert or Wireless Sensor Hub. AVTECH Software, Inc. Temperature & Environment Monitoring... Made Easy! AVTECH.com

Digital Temperature & Analog Sensor (RMA-DTA-SEN) Step 3: Connect your Digital Temperature & Analog Sensor to an analog sensor. Do not connect the analog inputs on AVTECH products to live circuits of over 5 VDC. Use only low-voltage 2-wire cable to connect analog inputs. You may use any low-voltage two-wire cable to connect the analog input port to the analog output port on your analog sensor. AVTECH stocks 25' speaker wire for this purpose; please contact your Product Specialist to purchase this cable. 1. Separate and strip both ends of a low-voltage two-wire cable (such as speaker wire). Expose about ¼" of wire. 2. Connect one set of leads to the analog input port on the Temperature & Analog Sensor. Be sure the bare wire, not the insulation, connects to the port. Note that the port is polarized: the left contact is positive (+) and the right is negative (-). + 3. Run the cable back to your analog sensor. Try to avoid running it near large electromagnetic devices or fluorescent lights, which produce EMI and can interfere with sensor readings. 4. Connect the +/- wires to the matching +/- contacts on your analog sensor. Sensor Features & Specifications Environment Condition Monitored Indoor ambient temperature & analog sensor output Type Of Sensor Digital Power Supply Powered by Room Alert Sensor Cable Type Digital Sensor Cable RJ-11 (standard straight-through telephone cord) Included Yes Length 25' Maximum Extendible Length 100' Analog Input Cable Low-voltage 2-wire speaker cable Included No Maximum Extendible Length 900' Temperature Range -40 F to 185 F (-40 C to 85 C) Accuracy +/- 2 C Resolution 0.03125 C Analog Input Range 0-5 VDC Accuracy +/- 0.075 V Resolution 0.01 V Compatible Products Room Alert 32E/W, 24E, 12E, 4E, 3E, 3W and Wireless Sensor Hubs AVT-170825-2.0.1 AVTECH Software, Inc. Page 2 AVTECH.com

Configure Your Digital Temperature & Analog Sensor Use Room Alert s Built-In Web Interface Navigate to Settings Sensors in the web interface of your Room Alert. The options you see below will vary depending on the model. 1. Scroll to your external digital sensor(s), the total number of which will vary depending on the Room Alert model. 2. Find the digital sensor interface that matches the port you connected your Digital Temperature & Analog Sensor to. For example, if you used the first digital port on your Room Alert, look for Sensor 1 Alarm Configuration; if you used the second, look for Sensor 2 Alarm Configuration, and so on. 3. Notice that your Room Alert automatically detects the digital sensor and inserts a dropdown list in Sensor Type, which defaults to Temp/Humidity. Select Temp/Analog to bring up the interface for your Digital Temperature & Analog Sensor. 4. Then, configure the set of fields on the bottom of the Temperature & Analog Sensor display to calculate your analog sensor s output signal to scale. In this example, we are converting volts to amperage: AVTECH Software, Inc. Page 3 AVTECH.com

Click Enable to turn on the Reference, Scale and Units fields. In Reference, enter values from 5 to 0 that represent the High and Low points of your analog sensor s output signal range. Here, we ve left the default values of 5 to 0. In Scale, enter the High and Low points of the scale you want the Reference reading to be converted to. In this example, we would like to convert 0-5 volts to 0-10 amps, so we ve put 10 in High with 0 in Low. 5. Next, fill in the set of fields on the top of the Temperature & Analog Sensor display: In Sensor X Label, you may leave the default, Ext Sensor X, or enter something more descriptive of up to 15 characters. You may use the following characters in sensor labels: letters, numbers, spaces, hyphens (-), underscores (_) and periods (.). Alarm On automatically populates with the default temperature scale and Analog. Please refer to your Room Alert User s Guide & Reference Manual to change the default temperature scale. In High and Low, you may leave the default, 0 which means no alarm is configured or enter values for high and low thresholds. Your Room Alert generates alerts based on these thresholds. Note that for the analog High and Low fields, the values must fall within the analog Scale range from the previous step. In our example, we entered a conversion scale of 0 to 10 (amps) in the previous step, and we ve chosen to generate alarms at the high and low thresholds of 6 and 2 (amps). AVTECH Software, Inc. Page 4 AVTECH.com

In Adjust, you may leave the default, 0, or enter a value to adjust the temperature or analog reading if it differs from a known value at that location. In Use Alarm Profile, which controls light towers and relays on your Room Alert, you may leave the default, Profile 1, or choose another profile from the drop-down menu. 6. Select Save Settings at the top or bottom of the page. Your Room Alert will automatically reboot and commit your changes. Use AVTECH s GoToMyDevices For The Convenience Of The Cloud Monitor unlimited Room Alert devices and sensors through the cloud from anywhere anytime! It s quick, easy and powerful. Enjoy the same look and feel from any device, whether you use a phone, tablet, laptop or desktop computer. Alert, log, graph, view, report, and manage your Room Alerts, with no software to install or update. Create an account today at GoToMyDevices.com to begin! Use AVTECH s Device ManageR Software For Advanced Functionality For advanced functionality and easy management of multiple units, configure your sensor with AVTECH s Device ManageR, the software that comes FREE with the purchase of any Room Alert. You may download the latest version from your account at GoToMyDevices.com while your subscription for extended service and support is active. AVT-170825-1.0.1 AVTECH Software, Inc. Page 5 AVTECH.com