Version: E Manual Timeout

Similar documents
Version-E Manual

THE SPORTS TIMING EXPERTS

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

Tube Rotator. User Guide. Version 1.2

INSTRUCTION MANUAL. Controller CLT-500 / RG-500

User s manual. Digitales TV module for NAVIGON English (United Kingdom)

PRO Mixer Distro User Guide

TVAC20000 User manual

P R O F E S S I O N A L T I M I N G CHRONOPRINTER 520 OPERATING INSTRUCTIONS

EC5415B. B-Tronic EasyControl. Assembly and Operating Instructions. Wall/hand-held transmitter, 15-channel, bidirectional

Website: Tel: ADDRESS: 6475 Las Positas Rd. Livermore, CA Item No. E5B/E5S Installation Guide

NetterVibrotron SRF. Operating Instructions for. Series SRF. These operating instructions apply to. Netter Static Adjustable Frequency Control

Style 5S Clock / Timer

For installation queries contact Customer Services (0) TCR IP 4 Operating instructions

aquauno INSTRUCTIONS WATER TIMER VIDEO VIDEO

Model: LCD4WM 3.5 Window Mounted LCD Monitor User Manual Features

OPERATING MANUAL. DMX / DSI / DALI Dekoder 3004B-H Mk2

MARCO CORNER, 19/ THIENE (VI) ITALIA

Operating Manual. DVB-T Meter MFK 16

KHT 1000C HV-Probe Calibrator. Instruction Manual

LINK-MI LM-WHD05B. Wireless HDMI AV Transmission System. User Manual

O P E R A T I O N M A N U A L. RF-Reader. Stand-alone-Reader Leser 2plus with RS-232 interface

Users Manual. Stroboscope. September 2014

OPERATING MANUAL. DMX512 to DALI Dekoder 7044A-H Mk4

General TdC 8001 Timy3 WP Wireless Timing:

Instant 802.3af Gigabit Outdoor PoE Converter. Model: INS-3AF-O-G. Quick Start Guide

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

SWISS TIMING Service catalogue FIS World Cup Ski Jumping / Ski Flying 2017/2018

SWISS TIMING Service catalogue FIS World Cup Ski Jumping Ladies 2017/2018

Operating instructions

Manual. racing Micro Magic HoTT. ARTR RC sail-boat with HoTT receiver HoTT

Operation Manual VMS 3.0 Video System

USER MANUAL Table of Contents

INSTRUCTIONS FOR USE Pro-Ject Receiver Box S

Installation Manual Original Instructions - IW4001

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

Disclaimer of Product & Services The information offered in this instruction manual is intended as a guide only. At all times, Datavideo Technologies

OPERATING MANUAL. DMX LED Current Dimmer 5004A-EP Mk2

HD-CM HORIZON DIGITAL CABLE METER

Thank you for purchasing SEIKO SHOOTING TIMER KT-401. Before using your SEIKO SHOOTING TIMER, please read this manual carefully for its proper use

CONQUEROR STEREO POWER AMPLIFIER OWNER S INFORMATION

User Instructions. 16 SCB Sync Station.

Please read this manual before using the C961 Display. Suzhou Bafang Electric Motor Science-Technology Co., LTD

DD624CS Hi-Def Video Circle & Cross Hair Overlay Generator. Users Manual. Colorado Video

Manual. Kingpad mc-edition light-module. Bus system control pad for installation in the Graupner mc-16 / mc-20 / mc-26 / mc-28 transmitter

Tube Roller Shakers. User Guide. Version 1.2

HDMI Extender over UTP Cable

MKE 2 Gold. Instruction manual

INSTALLATION MANUAL VIP 1903 / VIP 1903 T VIP 1963 / VIP 1963 T

OTO Phono SE Signature

Connect 350 UHD. Connect 350 UHD USER MANUAL 3 GEBRAUCHSANLEITUNG GUIDE UTILISATEUR MODO DE EMPLEO MANUALE D ISTRUZIONI GEBRUIKSAANWIJZING

Installation Manual VIP 1003

MEISHU Phono INTEGRATED AMPLIFIER OWNER S INFORMATION

STC 160 Head-End Station Quad modulators

Compact 60. Solutions. Manual English

User Manual. AtlonA. Passive VGA Extender with Wall Plate or Box options up to 330ft over 1 x CAT5/6/7 Cable AT-VGA100-SR and AT-WPVGA-SR AT-WPVGA-SR

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E

DisplayPort to VGA Converter

Ambient Weather WS-01 Intelligent Color Changing Temperature Night Light with Ambient Backlight User Manual

USER MANUAL. 27" 2K QHD LED Monitor L27HAS2K

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.

AVS50 USER GUIDE. 2.4GHz Audio/Video Sender System - AVS50

DVDO VS4 HDMI Switch. User s Guide How to install, set up, and use your new DVDO product

Do not install and/or operate this safety product unless you have read and understand the safety information contained in this manual.

Channel Controller for Light Show with Remote Control. HomLiCon RCL164R

Owner s Manual LED COMMANDER 16/2

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Model Number ALS-ELUM-RGB-CNTRL-1. elum RGB Controller

FogScreen emotion Projection Screen. User Manual Part 1: Installation Guidelines

ATTACHING & REMOVING THE BASE

OPERATING MANUAL. DMX Demultiplexer 3012B Mk2

LCD Thermometer / Clock S No. 1253

21 Channel Light Show PWM LED Controller with Remote Control

OPERATING MANUAL. DMX512 to DALI Dekoder 7044A-H Mk1

8 Port HD/SD-SDI Video Switch with 2 Port Splitter

.Power Distribution Center. PD-1. Instruction Manual

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Fusion 120 Zoom. User Manual. Order code: EQLED068

Instruction Manual. Wireless Transmitters (Digital) RVS-550W. Reverse With Confidence 1

AITech ProA/V Media Extender 5GHz Digital

Operating Instructions

ZU 251. Incremental Counter Module With Analogue Output and Serial Interface. Operating Instructions. control motion interface

Guidelines for Wiring, Electronic Timing and Scoring Systems Table of Contents

Manual FERROFISH A16 MK-II. advanced audio applications. professional 16 channel AD/DA converter

M2 RIAA PHONO STAGE OWNER S INFORMATION

Quick Start Digital Terrestrial Receiver

TRIPLETT. PairMaster. Lan Cable Test Set. Instruction Manual

Atlona HDBaseT-Lite Transmitter over Single CAT5e/6/7

Advanced Digital Melting Point Apparatus

PERFECT Operating and Installation Manual

CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC

DVB-T305. Freeview HD Receiver Récepteur TNT HD DVB-T Receiver Ricevitore TDT HD Sintonizador TDT HD EN FR DE IT ES

USER MANUAL. WARNING Read the instructions before using the machine. EN (Original Instruction) / 1704

DIGITAL MODULATOR SINGLE DVB-T ENCODER/MODULATOR USER MANUAL

Mini Electronic Pulse Massager

Installing the FOREST SHUTTLE S / L

RemotePoint. Navigator. User s Manual VP4150

PicoScope 2000 Series PC Oscilloscopes

User manual Hardware manual. Casablanca S series S-2000 / S-4000 / S-4100

Chapter 1 : FCC Radiation Norm...3. Chapter 2 : Package Contents...4. Chapter 3 : System Requirements...5. Chapter 4 : Hardware Description...

Transcription:

Version: E160428 Manual Timeout

Important Information General Manual Timy3 - Timeout Before using your ALGE-TIMING device read the complete manual carefully. It is part of the device and contains important information about installation, safety and its intended use. This manual cannot cover all conceivable applications. For further information or in case of problems that are mentioned not at all or not sufficiently detailed, please contact your ALGE-TIMING representative. You can find contact details on our homepage www.alge-timing.com Safety Apart from the information of this manual all general safety and accident prevention regulations of the legislator must be taken into account. The device must only be used by trained persons. The setting-up and installation must only be executed according to the manufacturer s data. Intended Use The device must only be used for its intended applications. Technical modifications and any misuse are prohibited because of the risks involved! ALGE-TIMING is not liable for damages that are caused by improper use or incorrect operation. Power supply The stated voltage on the type plate must correspond to voltage of the power source. Check all connections and plugs before usage. Damaged connection wires must be replaced immediately by an authorized electrician. The device must only be connected to an electric supply that has been installed by an electrician according to IEC 60364-1. Never touch the mains plug with wet hands! Never touch live parts! Cleaning Please clean the outside of the device only with a smooth cloth. Detergents can cause damage. Never submerge in water, never open or clean with wet cloth. The cleaning must not be carried out by hose or high-pressure (risk of short circuits or other damage). Liability Limitations All technical information, data and information for installation and operation correspond to the latest status at time of printing and are made in all conscience considering our past experience and knowledge. Information, pictures and description do not entitle to base any claims. The manufacturer is not liable for damage due to failure to observe the manual, improper use, incorrect repairs, technical modifications, use of unauthorized spare parts. Translations are made in all conscience. We assume no liability for translation mistakes, even if the translation is carried out by us or on our behalf. Disposal If a label is placed on the device showing a crossed out dustbin on wheels (see drawing), the European directive 2002/96/EG applies for this device. Please get informed about the applicable regulations for separate collection of electrical and electronical waste in your country and do not dispose of the old devices as household waste. Correct disposal of old equipment protects the environment and humans against negative consequences! Copyright by ALGE-TIMING GmbH All rights reserved. Any duplication, either in full or in part, requires the prior written consent of the copyright holder. Page 2 Manual General

TIMY3 - Timeout Declaration of Conformity We declare that the following products comply with the requirements of the listed standards. We, ALGE-TIMING GmbH Rotkreuzstrasse 39 A-6890 Lustenau declare under our sole responsibility, that the timing device Timy3 W and Timy3 WP is in conformity with the following standard(s) or other normative documents(s): Safety: EN 60950-1:2006 + A11:2009 EMC: EN55022:2006+A1:2007 EN55024:1998+A1:2001+A2:2003 EN61000 3-2:2006 + A1:2009 + A2:2009 EN61000 3-3:2008 Additional Information: The product herewith complies with the requirements of the Low Voltage Directive 73/23/EEC, also the EMC Directive 2004/108EG and accordingly carries the CE-marking. Lustenau, 03.10.2013 ALGE-TIMING GmbH Albert Vetter (General Manager) Page 3

Timy3 - Timeout Table of contents 1 Device Describtion... 4 1.1 Control Elements... 4 1.2 TIMY3 Models... 5 1.3 TIMY3 Software... 5 1.4 Driver Installation... 6 2 Start Up... 6 2.1 Switch On... 6 2.2 Switch Off... 6 3 Program Timeout... 7 3.1 Function... 7 3.2 3.2.1 Menu... 7 Countdown for Show Jumping... 7 3.3 Used Channels... 7 1 Device Describtion A detailed device describtion of the Timy3 you will find in the general manula. This manual describes only the software TIMEOUT. 1.1 Control Elements 1... USB-interface 2... Charging socket 3... ALGE multiport 4... Connection for display board 5... Connection for start emitter (C0) 6... Connection for finish emitter (C1) 7... Standard ALGE photocell socket Page 4

1.2 TIMY3 Models Manual TIMY3 - Timeout Both TIMY3 models are equipped with a temperature compensated quartz-oscillator and therefore suited for highest accuracy. The extended temperature range allows operating the TIMY3 from +50 C until -20 C (for summer and winter sports) TIMY3 W: TIMY3 W is a timing device without printer. TIMY3 WP: TIMY3 WP is a timing device with integrated printer. 1.3 TIMY3 Software Available programs for the TIMY3: Stopwatch: universal timing program which is suitable for several heats (run/total time). Backup: to measure time-of-day times (e. g. as backup-system or as time reference for the computer) PC-Timer: to measure time-of-day times with simultaneous output of the running time in 1/10 seconds via the RS232 interface. Ideal as an accurate timing device for the computer LapTimer: timing program with run times and lap times (e. g. for motor sport) TrackTimer: timing program for events with several lanes, e. g. athletics and swimming Training Lite: universal training software (several intermediate times are possible) Training REF: training software with reference run (several competitors on course) Speed: speed measurement Commander: terminal for diverse subprograms (see manual) CycleStart: program for track cycling with countdown and lap counter Terminal: terminal for judges (e. g. gymnastics) Wind Speed: for measuring the wind speed, only with anemometer WS2 Parallel-Diff: timing for parallel slalom (difference time of both slopes) Dual Timer: timing of two separate courses Timeout: timing with timeout, also applicable for show jumping (with start countdown) Swim Trainer: training program for swimming Jumping: training program for jump trials, measures jumping height on the basis of time between jump and landing on a contact mat (several subprograms) Speed-Climbing: timing for parallel competitions at speed climbing with false start TV-Timer simple timing program for controlling a display board or TV time flashs Page 5

Timy3 - Timeout 1.4 Driver Installation For installation of drivers, separate manuals are available. You can download them on our homepage www.alge-timing.com or contact your ALGE representative. 2 Start Up 2.1 Switch On Press START/ON key Display shows: Really switch-on? Press the green OK button! If you press the green OK key within 10 seconds, the TIMY3 switches on, otherwise it automatically switches off. 2.2 Switch Off You have got two possibilities to switch off the TIMY3: Method 1: Press STOP/OFF key for 3 seconds Display shows: Really switch-off? Press the red OK button! If you press the red OK key within 10 seconds, the TIMY3 switches off, otherwise it returns to the program. Method 2: Press 2nd and STOP/OFF keys Display shows: Really switch-off? Press the red OK button! If you press the red OK key within 10 seconds, the TIMY3 switches off, otherwise it returns to the program. Page 6

TIMY3 - Timeout 3 Program Timeout The program TIMEOUT is speciel designed for the timing in show jumping (Equestrian), but it can be used as well for other sports that use a timeout. For show jumping this program is only usable for the timing, but not for the points. You can not input points and it will not calculate points if the time is over the allowed clear round time. 3.1 Function In the Menu ( ) <TIMEOUT> it is possible to adjust the Countdownzeit (e.g. 0:00.0 means without Countdownzeit). The factory setting is 50 s. Channel C4 starts the Countdown and starts and stops a Timeout. After a stop impulse (chanel C1 or key ) you can use the key <NEXT> as timing impulse for the start of the the jump off (this means the time starts again form 0:00.00). After a stop impulse (chanel C1 or key ) you can use the key <EXT> to continue with the timing (e.g. after a false finish impulse or after a intermediate time). You can change to another competitor by inputting a new start number (bib) with the keyboard and confirm it with. With key and you can switch to the next start number (bib) With key and you can restart the acctual start number (bib) Points and timing points from equestrioan are not used or calculated with this software. 3.2 Menu You get into the Menu by pressing the key. In the menu you can adjust different prameters and functions. (see manual Timy3 General). 3.2.1 Countdown for Show Jumping The Countdown for show jumping is by rule 50 seconds. This is also the factory setting. You can change in this menu the countdown time of turn the countdown time off (input 0:00.0) for sports that do not use a countdown. Press key With the key you go down down in the menu structure to reach the <TIMEOUT> menu. Press key or to get into the menu <TIMEOUT> Press key or to get into the menu <COUNTDOWNZEIT> Input time that you need for the countdown (input 0:00.0 for no coutndown) 3.3 Used Channels C0... Start C1... Finish C4... Countdown and Timeout Page 7

Timy3 - Timeout Subject to changes Copyright by ALGE-TIMING GmbH Rotkreuzstr. 39 6890 Lustenau / Austria www.alge-timing.com Page 8