Model GS7000 GainMaker Node Forward Local Injection Module Installation Instructions

Similar documents
Model GS Port Node 1 GHz with 65/86 MHz split

1.2 GHz GS7000 Node RF Split Upgrade Application Note

Cisco GS7000 High-Output 4-Way Segmentable Node with 42/54 Split

Cisco GS MHz 4-Way Segmentable Node

Cisco GS7000 High-Output (GaN) 4-Way Segmentable Node with 85/102 MHz Split

Compact Mini Amplifiers Series and Series

Compact EGC Amplifier Model 93250

Cisco 1.2 GHz GS7000 Node Installation and Operation Guide

User Manual CXE Rev (12) CXX Series. User Manual. Teleste Corporation CXE810. Fibre optic receiver

PowerVu Program Receiver (D9850) Application Note

Headend Systems. Series 9900 RF Signal Manager Modules. Introduction. Description

Turret Replacement Instruction Manual

Installation Note. Option GHz Operation Upgrade Kit. For 8753E and 8753ES Network Analyzers. Applicable Upgrade Kit Model Number

HFC. Enhance. QHFCN CATV Optical 2-way Mini Node Installation & Operation Guide

Compact EGC Fiber Deep Nodes A90100 and A90300

Prisma Optical Networks Ancillary Modules

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

User Manual CXE800. Fibre Optic Receiver. CXX Series. Teleste Corporation

LGX Compatible (LSX) Connector Module) User Manual)

TRFM Series RF Amplifier Module

D3.1/CCAP Compliant HFC. Enhance. QHFCN CATV Optical 2-way Mini Node INSTALLATION & OPERATION MANUAL.

Prisma D-PON System 1550 nm Downstream Transmitter and EDFA

Perle Fast Ethernet Fiber to Fiber Media Converter Module. Installation Guide. P/N (Rev D)

8753E, 8753ET, and 8753ES Network Analyzer Option 1D5 High Stability Frequency Reference Upgrade Kit. Applicable Upgrade Kit Model Number

Cisco Model DPC3000 DOCSIS 3.0 Cable Modem

OL GS7000 GainMaker Scalable 4-Port Node Installation and Operation Guide

Traditional RF Splitter/Combiner and Directional Coupler User Manual

Prisma D-PON System ONT and Upstream Receiver

3M Fiber Optic Wall Mount Enclosure 8430 Series

M1, M2GO and M2PC MIDI PCB Module Installation Guide SMPTE PCB Module Installation Guide

QFMN. QFMN Fiber Mini Node Distribution Amplifier INSTALLATION & OPERATION MANUAL.

Traditional RF Splitter/Combiner and Directional Coupler User Manual

Product Operation Manual

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

HD Flex Patch Panel. ASSEMBLY VIEW (FLEX1UPN** shown) FS128B. CONTENTS: (#) indicates FLEX4UPN** quantity

Agilent 87075C 75 Ohm Multiport Test Sets for use with Agilent E5061A ENA-L Network Analyzers

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

900 Series Amplifiers

2000 Series Weather Stations Analog Temperature / RH Sensor Upgrade Kit PRODUCT MANUAL KIT # 3613WDU

QFN. QFN Fiber Node INSTALLATION & OPERATION MANUAL.

DREAMOC DIAMOND 4K - ASSEMBLY GUIDE VERSION ORIGINAL ASSEMBLY GUIDE

Test Port Adapter Rohde & Schwarz Interchangeable Port Connector Application Note

2100, 2200, 4100, 6200, MPB Series Side Mount Drive Package for Light Load 60 Hz Gearmotors

TV Lift System Model CL-65 Installation Instructions

OmniStar GX2 Headend Optics Platform

Hardware installation

Replacing the PanelMate epro PS, PanelMate epro PS EE, and PanelMate epro PS OD 7685x-12 Series Backlight Assembly

Instruction Manual.... light years ahead. S739DV & S7739DV Video and Up-the-Coax Control Systems

Cisco RF Gateway 1. Product Overview

Quick Release Roof-Mount Kit MB700

3G-SDI Fiber Optic Digital Extension Modules in 19 1RU Frame

OL Model GS7000 Optical Hub Installation and Configuration Guide

SUBCARRIER TRANSFER FILTER INSTRUCTION BOOK IB622702

HCS - HES Cabling Systems

User Guide. HDMI Fiber Optic Extender. DVI-7350a

Program Announcement. ARRIS Refurbishment Program FP to DFB Laser Upgrades for Legacy. Optiworx ISX 3030 and ISX 3040 Return Transmitters

SLiC Fiber Aerial Closure System

SignalOn Series. L-Band Power Inserter Module INSTALLATION & OPERATION MANUAL. 1.2 GHz. D3.

INSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras

2178-L/S Series Fiber Optic Splice Case with Gasket

RS-232 to Multi-Mode Fiber Optic Media Converter

SignalOn Series. L-Band Splitter Module INSTALLATION & OPERATION MANUAL. 1.2 GHz. D3.

Medium Box for Cable Termination

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR

24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual

Installation Instructions. What This Option Provides

Vibratory Deck Sieves 15 in. (380 mm)

Model /29S RF Splitter

RADIO FREQUENCY SYSTEMS

MODELS USIX-024 AND USIX-120 INSTRUCTION SHEET FOR FEDERAL SIGNAL UNISTAT STATUS INDICATOR MODEL USIX

QCA9-33 Active Combiner

Agilent 86120B, 86120C, 86122B Multi-Wavelength Meters. Data Sheet

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

IP-LINX. Installation Guide

3 Closure preparation 3.1 Work-stand 3.2. Opening FIST-GCOG2-Dx Preparing drop cable with micro-tubes

OmniReach FTTX Solutions RealFlex DLX Universal Drop Cable Instruction Sheet

46 GBaud Multi-Format Optical Transmitter

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

Surge-Gap Drop Amplifier 1 GHz with 42/54 MHz Split

FOSC 450 C6 and D6 Closures

USER GUIDE. DM Engineering Multi Station Relay Adapter (MSRA and MSRA-RM) Version DM Engineering

TeamWork Installation Guide

2100/2200/4100/6200 & MPB Series Bottom Mount Drive Pack. for Standard Load Parallel Shaft 60 Hz Gearmotors

CHP Max Headend Optics Platform CHP CORWave II

OFDC-B8-72. Outdoor fiber distribution closure. 6 Closing. Content 1 Introduction. 7 Re-entry. 2 Kit content. 3 Closure preparation

TracVision R6DX Installation Guide

OmniStar GX2 Headend Optics Platform

OTLT / OTLR 3000 Manual. L-Band Fiber Optic Link MHz INSTRUCTION MANUAL

SCdefault. 900 Installation instructions. Accessories Part No. Group Date Instruction Part No. Replaces :36-29 Sep

ODN2000/LE2000. User Manual. Optical Distribution Node/Line Extender with Two Amplified RF Ports. Offices: Australia, Melbourne: Tel.

GE Interlogix Fiber Options S700V & S702V. Instruction Manual FIBER-OPTIC VIDEO TRANSMISSION SYSTEM

User Guide. Single-Link DVI Active Cable Extender. DVI-7171c

TracVision 95W LNB Installation

User s Guide TN-GB-SM512. Gigabit Interface Converter (GBIC) Transceiver Modules

ChromaFlex. ChromaFlex CF-QRRX Quad Analog Return Path Receiver Modules HARDWARE INTERFACE MANUAL.

Cisco Prisma II 1310 nm, High-Density Transmitter and Host Module for 1.2 GHz Operation

User Guide. DVI + HDCP Fiber Optic Extender DVI-7330

Agilent M9362A-D01-F26 PXIe Quad Downconverter

Backlight Replacement

IP-LINX Fiber :: X-XXXX

Transcription:

Model GS7000 GainMaker Node Forward Local Injection Module Installation Instructions Introduction The Forward Local Injection (FLI) Module is a field installable accessory for the Model GS7000 GainMaker Scaleable 4-Port Node. The FLI Module routes an RF signal from an external source to the Forward Configuration Module (FCM) in the node through the Optical Interface Board (OIB). This signal is then coupled with other inputs from one or more optical receivers. Note: The FLI Module Field Upgrade Kit, part number 4013575, contains the parts necessary to add forward local injection functionality to your Model GS7000 Node.

Product Description Product Description Overview The FLI Module acts as the interface between an external RF source and the Model GS7000 Node. The RF signal enters the Model GS7000 Node though port F2 in the node housing lid. An RF cable assembly is provided to route the signal from port F2 to the input connector on the FLI Module. (Port F1 entry is optional, but requires a shorter RF cable.) The FLI Module accepts the RF signal through a female F-type push-on connector on the top cover of the module housing and routes the signal to the OIB through a signal pin. The FLI Module is designed to be mounted in the "RCVR 4" position on the OIB in the node. An RF test point on the module provides a sample of the RF signal at -20 db for level monitoring. Note: A special "Local Injection" version of the 1x2 Redundant FCM must be installed in the node to facilitate the operation of the FLI Module. Technical Specifications The FLI Module meets the following technical specifications. Forward Injection Port Performance Units 7.5 db I/S EQ with 1.5 db I/S Pad Operational Gain (minimum) db 19.5 1 Frequency Response db ±0.5 Internal Tilt (±1 db) db 14.5 2 Input Return Loss db 16 3 Notes Notes: 1 Forward operational gain is for station from forward injection port to node RF output port with 0 db pad in OIB, 1x2 Redundant Injection FCM, 1.5 db interstage (I/S) pad, 7.5 db linear I/S EQ, factory select output pad. Includes OIB losses; ~ 2.25 db loss through the FLI Module and RF cable, and ~ 15 db loss through the FCM. 2 Internal tilt is "Linear" tilt and is primarily due to an on-board fixed equalizer and a factory configured 7.5 db linear I/S EQ. 3 Input Return Loss specified for Forward Injection port. 2 4019330 Rev B

Node Overview Illustration Product Description The following illustration shows the location of the FLI Module and associated components as installed in the node. 4019330 Rev B 3

FLI Module Installation FLI Module Installation Required Components The following components are required to implement Forward Local Injection in the Model GS7000 Node. Note: These parts (except for item number 5 pads) are included in the FLI Module Field Upgrade Kit. 1 Forward Local Injection Module. 2 FLI Module RF Cable Assembly. 4 4019330 Rev B

FLI Module Installation 3 Local Injection version of the 1x2 Redundant Forward Configuration Module. 4 F-type bulkhead RF connector assembly for port F2 (or optional port F1) on node housing lid. 5 Two 1.5 db pads for the FWD I/S pads on the GS7000 Node RF amplifier assembly. Note: Pads are not included in upgrade kit. Obtain those from your normal onhand node accessories. Installing the FLI Module Note: This example uses port F2 for the external RF source. This should represent the majority of installations, since port F1 is most commonly used as the input port for the optical fibers. Important: For complete information on opening/closing the node and working on components inside the node, refer to Model GS7000 GainMaker Scaleable 4-Port Node Installation and Operation Guide, part number 4013584. Complete the following steps to install the FLI Module in the node. 1 Open the node housing. 2 Place the FLI Module in the RCVR 4 position on the OIB in the node housing lid and insert the module until it is connected to the OIB. Note: If an existing receiver module is in the RCVR 4 position, it must be moved to a different RCVR position. Refer to Receiver/Transmitter Module Removal and Replacement. 3 Tighten the module retaining screws to secure the module in the node. Torque the screws from 25 to 30 in-lbs (2.8 to 3.4 Nm). 4019330 Rev B 5

FLI Module Installation 4 Insert the threaded F-type connector on one end of the RF cable assembly through port F2 and outside the node housing and connect it to the bulkhead RF connector as shown in the following illustration. 5 Thread the bulkhead RF connector assembly into port F2 on the node housing lid as shown in the following illustration. Torque the connector from 3 to 4 ft-lbs (4.1 to 5.4 Nm). 6 Route the RF cable to the left through the fiber channel in the node and toward the FLI Module. 6 4019330 Rev B

CAUTION: FLI Module Installation Be careful not to damage any existing transmitter or receiver fibers or fiber connectors when routing the RF cable. Note: The following illustration shows the installation with optical receivers and transmitters removed to provide a better view of the RF interface cable routing in the fiber channel. 7 Insert the right-angled G-type connector of the RF cable assembly into the Input connector on the FLI Module as shown in the previous illustration. 8 Install the Local Injection version of the 1x2 Redundant FCM into the RF amplifier assembly in the node housing base. Note: To remove the existing FCM, pull up carefully on its integrated handle until it separates from the RF amplifier assembly. 9 Replace the two existing FWD I/S pads (located directly above the FCM on the RF amplifier assembly) with 1.5 db pads. 10 Close the node housing. Refer to Closing the Housing for complete instructions. 11 Connect the external RF source to port F2 on the node housing lid. 4019330 Rev B 7

FLI Module Installation Closing the Housing Close the housing as follows. 1 Ensure any worn gaskets are replaced, and the gaskets are clean and in the correct position. 2 Carefully close the lid. CAUTION: Use caution when closing housing. Improper closing may result in the Model GS7000 Node not being sealed from the environment. 3 For strand-mounted housings, pull the lid away from the base and remove the slack from the hinge before rotating the lid up toward the base. 4 Ensure no cables are pinched between lid and base. 5 Secure lid to base with bolts. Tighten from 5 to 12 ft-lbs (6.8 to 16.3 Nm) in the sequence shown in the following illustration. Repeat the sequence twice, ending with the final torque specification. Receiver/Transmitter Module Removal and Replacement Depending on the module population of your particular node, it may be necessary to relocate or remove and replace an optical receiver or transmitter to facilitate the installation of the FLI Module. If necessary, complete the following steps to remove and replace an optical receiver or optical transmitter. 1 Open the node housing. 2 Carefully tag and remove any optical fibers from the receiver or transmitter module. 8 4019330 Rev B

WARNING: FLI Module Installation Laser light hazard. Never look into the end of an optical fiber or connector. Failure to observe this warning can result in eye damage or blindness. 3 Loosen the screws securing the module. 4 Lift the module straight up out of the housing to unplug it. Note: Pull up on the built-in handle. 5 To install a module, position it in the desired location and carefully slide the module into its slot until connected to the optical interface board. 6 Tighten the screws securing the module. Torque screws from 25 to 30 in-lbs (2.8 to 3.4 Nm). 7 Carefully reconnect any optical fibers that were removed from the original module. Important: Clean optical connectors before reconnecting. Follow recommended fiber optic cleaning procedures. WARNING: Laser light hazard. Never look into the end of an optical fiber or connector. Failure to observe this warning can result in eye damage or blindness. 8 Close the node housing. Refer to Closing the Housing for complete instructions. 4019330 Rev B 9

For Information For Information Support Telephone Numbers This table lists the Technical Support and Customer Service numbers for your area. Region Centers Telephone and Fax Numbers North America SciCare Services Atlanta, Georgia United States For Technical Support, call: Toll-free: 1-800-722-2009 Local: 678-277-1120 (Press 2 at the prompt) For Customer Service or to request an RMA number, call: Toll-free: 1-800-722-2009 Local: 678-277-1120 (Press 3 at the prompt) Fax: 770-236-5477 E-mail: customer.service@sciatl.com Europe, Middle East, Africa Belgium For Technical Support, call: Telephone: 32-56-445-197 or 32-56-445-155 Fax: 32-56-445-053 For Customer Service or to request an RMA number, call: Telephone: 32-56-445-133 or 32-56-445-118 Fax: 32-56-445-051 E-mail: elc.service@sciatl.com Japan Japan Telephone: 81-3-5908-2153 or +81-3-5908-2154 Fax: 81-3-5908-2155 E-mail: yuri.oguchi@sciatl.com Korea Korea Telephone: 82-2-3429-8800 Fax: 82-2-3452-9748 E-mail: kelly.song@sciatl.com China (mainland) All other Asia-Pacific countries & Australia China Telephone: 86-21-6485-3205 Fax: 86-21-6485-3205 E-mail: xiangyang.shan@sciatl.com Hong Kong Telephone: 852-2588-4746 Fax: 852-2588-3139 E-mail: support.apr@sciatl.com Brazil Brazil For Technical Support, call: Telephone: 55-11-3845-9154 ext 230 Fax: 55-11-3845-2514 For Customer Service or to request an RMA number, call: Telephone: 55-11-3845-9154, ext 109 Fax: 55-11-3845-2514 E-mail: luiz.fattinger@sciatl.com 10 4019330 Rev B

For Information Region Centers Telephone and Fax Numbers Mexico, Central America, Caribbean All other Latin America countries Mexico Argentina For Technical Support, call: Telephone: 52-3515152599 Fax: 52-3515152599 For Customer Service or to request an RMA number, call: Telephone: 52-55-50-81-8425 Fax: 52-55-52-61-0893 E-mail: karla.lugo@sciatl.com For Technical Support, call: Telephone: 54-23-20-403340 ext 109 Fax: 54-23-20-403340 ext 103 For Customer Service or to request an RMA number, call: Telephone: 770-236-5662 Fax: 770-236-5888 E-mail: veda.keillor@sciatl.com 4019330 Rev B 11

Scientific Atlanta, A Cisco Company 5030 Sugarloaf Parkway, Box 465447 Lawrenceville, GA 30042 678.277.1000 www.scientificatlanta.com Cisco, Cisco Systems, the Cisco logo, the Cisco Systems logo, Scientific Atlanta, SciCare, and GainMaker are registered trademarks or trademarks of Cisco Systems, Inc. and/or its affiliates in the U.S. and certain other countries. All other trademarks mentioned in this document are the property of their respective owners. Product and service availability are subject to change without notice. 2007, 2008 Cisco Systems, Inc. All rights reserved. Printed in United States of America July 2008 Part Number 4019330 Rev B