SUPPLEMENTARY INFORMATION

Similar documents
HiPace 300 with TC 110 and power supply OPS 100, DN 100 ISO-F

Duo 65 C, 3-phase motor, 3TF, 230/400 V, 50 Hz 265/460 V, 60 Hz

CENTERLINE. Total pressure gauges

Vacuum measurement and control units

Duo 65 MC, 3-phase motor, 3TF, 230/400 V, 50 Hz 265/460 V, 60 Hz

HICUBE. The modular pumping stations for all applications in high and ultra-high vacuum

Okta 1000, Roots pump without motor

Duo 65 M, 3-phase motor, 3TF, 230/400 V, 50 Hz; 265/460 V, 60 Hz

Duo 65, 3-phase motor, 3TF, 230/400 V, 50 Hz; 265/460 V, 60 Hz

Okta 600, Roots pump, 230/400 V, 50 Hz; 265/460 V, 60 Hz

Operating manual incl. Declaration of conformity

Operating Instructions

Bayard-Alpert Pirani Gauge

IONIVAC Transmitter ITR 90

Control Unit CU 2.1 User Manual V6850A HPLC

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

Plug-in modules for total pressure gauges and controllers TPG 300 and IMG 300

ITER Product Catalogue. Total Pressure Measurement V Page 1 / 15

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

Sensor module. Safety instructions. Function Correct use. Product characteristics. Structure of the device. Operation. Ref.No.

Specifications. End-Point Linearity - ±5% F.S., when used with HACO SCR-speed control

ITER Product Catalog Total Pressure Measurement. ITER Product Catalogue Total Pressure Measurement V Page 1 / 15

Intelligent Vacuum Metrology New VSR, VSP, VSM & VSH series

D Issue G. Instruction Manual. Wide Range Gauge

12months. on-site warranty. DZE ELECTRONIC PRESSURE SWITCH for detection of overload per EN 81 2 featuring two adjustable switching points

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

DMP 331i / DMP 333i LMP 331 i

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Process Transmitter RMA 422

Standard signal metering in wall-mounting case

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

Assembly. Front view. LEDs. Parametrization interface. Power Bus

DLP200M 2 Relay Module for Heating and Cooling Plants

TELEDYNE HASTINGS INSTRUMENTS

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

A PASSION FOR PERFECTION. OktaLine. The Power Pump Portfolio. Roots Pumps for Every Low and Medium Vacuum Application.

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Process transmitter RMA422

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

Industriefunkuhren. Technical Manual. OEM Sync-Module FE1000 (IRIG-B) ENGLISH

PROPORTIONAL VALVES Sentronic plus

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

SCALE & WEIGHT DISPLAYS

Level Measurement silometer FMC 420, FMC 423

TDEPD. Field-Programmable Pressure Switch/Transducer with Integrated LED Display. Programming Sequence Manual

STC 160 Head-End Station Quad modulators

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

Documentation. Magnetic Encoder System (MES) Version: Date:

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

estat20 Electronic Humidistat with remote sensor head Technical data Electrical data Humidity Temperature +125 C

PR FESSIONAL PROFESSIONAL TERRESTICAL FM-FM PTFF Grundig SAT Systems

WIRING. Connection connector. NPN output type Standard type. Main circuit. High-function type. Main circuit. PNP output type.

DLP600M 6+1 Relay Module for Heating and Cooling Plants

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

General Information. Specifications. Introduction. Safety Instructions

INSTALLATION GUIDE FIRST STEPS MOUNTING OF THE SENSOR HANDLING THE WIRE ROPE

C200H-AD002/DA002 Analog I/O Units Operation Guide

Intelligent Security and Fire Ltd

Data Acquisition Using LabVIEW

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

HDMI Cross Converter

K3NX Process Meter OPERATION MANUAL

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Sensopress LCD Special English

Pressure Sensor. Ordering Information. Mini-Cube Pressure Sensor with Easy-to-Read LED Display

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

Dear Railway Modeller,

4.9 BEAM BLANKING AND PULSING OPTIONS

LASER. Laser-Position-Transducer. LLD Series. Key-Features:

Linear flow control with actuator IFC

Hardware & software Specifications

EZCOM-1. PLC - to - AMS MESSAGE DISPLAY INTERFACE INSTALLATION AND OPERATING INSTRUCTIONS. Rev March, 2001

Herzlich Willkommen Bienvenue Welcome. General Basics JUMO Screen Recorders. Manfred Schleicher

GESTRA Steam Systems NRR 2-50 NRR English. Installation & Operating Manual Level Controller NRR 2-50 Level Controller NRR 2-51

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

Quick Start. RSHS1000 Series Handheld Digital Oscilloscope

Operating instructions Electronic preset counter Type series 717

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

Outdoor Pixel-Router. User Guide

Your Global Automation Partner. Ultrasonic Sensors. Operating Instructions

Linear flow controls VFC Linear flow controls with actuator IFC

English TEL: Before operating refer to the instruction manual! Any person entrusted with the set-up or operation of the device, must have

System Power Supply 4. User Guide

Standard RS232 RS ma

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

Operating Manual. Basic Control BC16. two-channel for eco moon

SAFETY WARNINGS AND GUIDELINES INTRODUCTION CUSTOMER SERVICE

Re:connect M 203. RS232 Interface Revox. Dominating Entertainment. Revox of Switzerland. E 2.03

User Manual. for. Panel mounted instrument

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS

R&S OSP-B200R/B200S2 Satellite System for R&S OSP User Manual

Transcription:

RS485 analog/ relais device status RS485 5 adr. 5 9 7 SP SP2 adjust SUPPLEMENTARY INFORMATION EN XPT 200 AR DigiLine Gauge Translation of the original instructions PG 0029 BEN/C (605)

Validity Validity Analog/Relais This supplementary information describes important variations to the standard product and is only valid together with its prevailing operating instructions. Applicable documents xpt 200 AR Operating instructions Operating instructions DigiLine gauges in standard version: CPT 200 PG 002* HPT 200 PG 0024* MPT 200 PG 0025* PPT 200 PG 0022* RPT 200 PG 002* Declaration of Conformity A component of this manual *also available at www.pfeiffer-vacuum.com Abbreviations AR: Analog/Relay version BA sensor: Bayard-Alpert sensor CC sensor: Cold cathode sensor HV: High vacuum sensor Product description Function The (8-pole, A-coded) connector with the text "analog/relay" can be used to connect the gauge to an ActiveLine controller and to evaluate the switching contacts. The analog signal and relay contacts can also be evaluated using customer-specific circuitry. RS485 analog/ relais 2 S device status RS485 5 adr. 5 9 7 SP SP2 adjust SP/SP2 T Fig. : Connections RS-485 interface S RS-485 address selector switch T Adjusting button 2 Status LED SP Status set point Analog/Relay interface SP2 Status set point 2 2

Installation Installation Vacuum connection Establish a vacuum connection as described in the operating instructions for the standard gauge. Configuring the connection The analog/relay version of the DigiLine gauge allows a digital reading of pressure measurement values and provides various options for using the AR interface: Local pressure display with a TPG 26 or TPG 6 controller Mixed use of digital and analog gauges with a TPG 262, TPG 256 A or TPG 62 controller Pressure regulation with an RVC 00 controller in combination with a regulating valve Switching and safety functions through direct evaluation of switching contacts Voltage supply Power is supplied to the gauge either via the 5-pole RS-485 connector or the socket "analog/relay" (8-pole). NOTICE Damage to the product Only connect cables when de-energized. Never establish a connection using a live cable. 4 2 5 8 6 7 Pin Assignment Analog ground 2 Analog output Identification 4 Relay K 5 Relay K2 6 Relay "Common" 7 Supply voltage 24 V DC 8 Ground (GND) 24 V DC USB/RS-485 Converter analog 2 2 VACUUM analog ActiveLine TPG 62 Fig. 2: Connection diagram gauge (analog/relay) - TPG 62 (analog) / RS-485 (digital)

Operation 24 V DC USB/RS-485 Converter analog 2 2 RVC 00 VACUUM command edit Fig. : RVC 00 RME 005A Connection diagram gauge (analog/relay) - RVC 00 (analog) / RS-485 (digital) Operation Set points Status LED Setting the threshhold values The AR versions of the DigiLine gauges feature two pressure-controlled relay contacts that can be configured via the RS-485 interface using an external controller or a DPG 202 controller. Set points Status LED Meaning Relay SP Off Threshold value exceeded Inactive On (green) Threshold value not reached Active SP2 Off Threshold value 2 exceeded Inactive On (green) Threshold value 2 not reached Active The two relays are controlled by the two presettable set points SP and SP2. The hysteresis H is fixed at 5% of the threshold values (see Fig. 4). SP H p Fig. 4: Pressure and relay status curves illustrating threshold values and hysteresis 0 t 4

Operation Setting the set points via RS-485 Transmit the pressure value for set point using parameter 70 in the format 0- u_expo_new. Transmit the pressure value for set point 2 using parameter 72 in the format 0- u_expo_new. The pressures for the set points can also be read using the same parameters. For more information about the exchange of data, see the "Operation" chapter in the operating instructions for the standard gauge. Setting the set points using DPG 202 When connecting an AR gauge to a DPG 202 controller, the SET POINTS menu appears between the RELAY MENU and COMMON MENU. In this menu the two set points for the connected gauge can be set. ch: SP: 0 SP2: 2.0 SET POINTS SET POINTS After selecting this menu using the Menu key, the cursor flashes at the position ch: (measurement channel). Select the required channel number with the Up/Down keys. Use the set key to apply the channel number. set ch: SP: 0 SP2: 2.0 SET POINTS The cursor jumps to the pressure value for SP. Select the required pressure value for SP with the Up/ Down keys. Confirm with the set key. set ch: SP: 0 SP2: 2.0 SET POINTS The cursor jumps to the pressure value for SP2. Select the required pressure value for SP2 with the Up/ Down keys. Confirm with the set key. set 5

Operation Adjusting the gauge For details of the prerequisites for adjusting the gauge, refer to the "Operation" chapter in the operating instructions for the relevant standard gauge. Remove the rubber plugs from the "adjust" button access hole. Evacuate the vacuum chamber to the pressure p 0-5. Push the "adjust" button briefly with a small pin (screw driver, Allen key or the like). Vent vacuum chamber to atmospheric pressure with air or N 2 ; afterwards wait about 0 minutes. Push again the "adjust" button briefly. Reinsert the rubber plug. Limited adjustment scope For combination gauges, the adjustment of atmospheric pressure is limited to the Pirani sensor. For the CPT 200, a pressure of p 0. is sufficient for zero-point adjustment. In this case, an output signal of 0.9 V is set. When using ActiveLine controller this leads to a display of about -25 (-9 Torr). An atmospheric pressure adjustment for CPT 200 is not possible. Output characteristics of the analog signal p(u) = Pressure as a function of the output voltage U(p) = Output voltage as a function of the pressure FS = Full scale U = Output voltage in voltage OR = Over range UR = Under range dec = Decade Gauge CPT 200 AR RPT 200 AR PPT 200 AR HPT 200 AR MPT 200 AR Analog linear log V/dec log V/dec log 0.75 V/dec log 0.6 V/dec p(u) = (U-) * FS / 8 0 (U-c) 0 (U-c) 0 (U-7.75)/0.75+c 0.667*U-d U(p) = + 8 * p / FS c + log 0 p c + log 0 p 7.75+0.75*(log 0 p c) c + 0.6*log 0 p kpa c = 2.5 c = 2.5 c = -.0 c=7.4; d=2. Pa c =.5 c =.5 c = 2.0 c=5.6; d=9., mbar c = 5.5 c = 5.5 c = 0 c=6.8; d=. µbar c = 2.5 c = 2.5 c = -.0 c=5.0; d=8. Torr c = 5.625 c = 5.625 c = -0.25 c=6.875; d=.46 mtorr, µ c = 2.625 c = 2.625 c = 2.875 c=5.075; d=8.458 U max 9.0 V 8.68 V 8.5 V 0.0 V 8.6 V U min.0 V.5 V.5 V 0.774 V.82 V OR 9.8.5 V 9..5 V - - - UR 0.5 0.9 V 0.5 0.9 V 0.5 0.9 V 0.5 0.774 V 0.5.82 V Error - - - - 9.5 0.5 V Error < 0.5 < 0.5 V < 0.5 V < 0.5 V < 0.5 V Correction factors for gas type dependent sensors The correction factors can be written via the serial interface in the memory of the gauge; see operating instructions for the standard version of the respective gauge. 6

Accessories Accessories Designation Order number M2 m plug 8-pole with screw terminals DigiLine AR PT 48 07 -T Gauge cable DigiLine xpt 200 AR to TPG 6x, m PT 48 250 -T Technical data Parameter CPT 200 2.2 W.2 kω Parameter Parameter Parameter Parameter RPT 200 AR.2 W.0 kω PPT 200 AR.2 W,0 kω HPT 200 AR 9.7 W 7.2 kω MPT 200 AR.7 W. kω (Pirani); 9. kω (Cold Cathode and Pirani) 7

Declaration of conformity We hereby declare that the product cited below satisfies all relevant provisions according to the following EC directives: Electromagnetic Compatibility 204/0/EU Low Voltage 204/5/EU DigiLine CPT 200 A/R, PPT 200 A/R, RPT 200 A/R, MPT 200 A/R, HPT 200 A/R Harmonised standards and national standards and specifications which have been applied: EN 626-: 20 Group / Class B EN 5058: 202 Signature: Pfeiffer Vacuum GmbH Berliner Straße 4 564 Asslar Germany (Dr. Ulrich von Hülsen) Managing Director 206-05-02

VACUUM SOLUTIONS FROM A SINGLE SOURCE Pfeiffer Vacuum stands for innovative and custom vacuum solutions worldwide, technological perfection, competent advice and reliable service. COMPLETE RANGE OF PRODUCTS From a single component to complex systems: We are the only supplier of vacuum technology that provides a complete product portfolio. COMPETENCE IN THEORY AND PRACTICE Benefit from our know-how and our portfolio of training opportunities! We support you with your plant layout and provide first-class on-site service worldwide. Are you looking for a perfect vacuum solution? Please contact us: Pfeiffer Vacuum GmbH Headquarters Germany T +49 644 802-0 info@pfeiffer-vacuum.de www.pfeiffer-vacuum.com