Operating Instructions Dimmer for V Incandescent Lamps

Similar documents
Figure 1: Device components

1 Safety instructions. 2 Device components. 3 Function. Light Management Relay switch insert 2-channel. Art.-No.: 1202 URE.

System 2000 System 2000 HLK relay insert. 1 Safety instructions. 2 Device components. 3 Function. Order No. : Operating instructions

Sensor module. Safety instructions. Function Correct use. Product characteristics. Structure of the device. Operation. Ref.No.

Operating instructions. Universal timer switch display

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

ABB i-bus EIB Universal dimmer 6155 EB for Installation

Cyclo Series. user manual. MartinArchitectural

Manual for WMR-252 built-in receiver with universal dimmer

Digital Time Switch. Installation & Operating Instructions

TRF STEP-DOWN TRANSFORMER USER MANUAL

120cm (4x36 Watt) incl. Splitter Instruction Manual

2 Hour Electronic Boost Timer

LED MODULES READYLINE DL

Gamma instabus. Technical product information

4 Wiring Brochure Wiring and installation of specific control

4.0 Description. 2-channel operation D1 and D2 rated at 200 VA each. 1-channel operation D1 rated at 400 VA (see connection chap. 6.

15 Series - Dimmer

Tempus Lux Digital Photoelectric Switch D GB CZ BZT Installation and operating instructions BZT27731

LED Driver Compact dimming

Dimming actuators GDA-4K KNX GDA-8K KNX

Dimmers SЕRIES. Kitchen light control. Bedroom light control. Living room light control

KRF EMC Filters Installation, Operation and Maintenance Manual

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

Model Number Structure

Aspect 2 Circuit Digital Scene Control

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

Installation Manual Original Instructions - IW4001

Mosaic TM Dimmer 3 x 1000 W

ArteorTM Dimmer 3 x 1000 W / /60

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

7 Day Digital Time Switch

AUTOMATIC TAPING MACHINE INSTRUCTION MANUAL TAIYO SEIKI CO., LTD.

Power Injector 1520 Series

Dimming actuators of the FIX series DM 4-2 T, DM 8-2 T


7 Day Digital Light Switch with Optional Dusk Start

LED bar- Built-in constant current - 105Lm/W-thin 5.5mm-waterproof

LED Driver Linear / area fixed output

HID control gear Electronic. PCIS, PCS outdoor FOX B011 PCI outdoor. Ordering data. Circuit power1. tc/ta for 60,000 h For luminaires with 1 lamp

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

Model DT-311J. And DT-311J-230V(AC) DIGITAL STROBOSCOPE INSTRUCTION MANUAL

SubstiTUBE Value EM Fighter Tube Technical Datasheet

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Mini LED Pin Spot Light Model: PLS00571

16 Amp Electronic 24 Hour/7 Day Time Controller

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

SceneStyle2 User Guide

LED control gear Compact fixed output

Octagon Theater CW/WW/A 20 6W LED PAR. user manual

CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC

Ariadni Dimmer For 250W CFL/Led, 600W Inc/Hal, or Lutron Hi-Lume A-Series Lte Led Driver, Clamshell Packaging In White

SquareLED - Aura Bar & Matrix Beam Light 100

KingWash 7QX 7x40w,Zoom 5-60degree. User manual. Please read the instructions carefully before use TABLE OF CONTENTS

LED control gear Compact fixed output. Uconverter LCI 55 W 1400 ma O010 TOP series Ø4,4. Ordering data

TVAC20000 User manual

DIN-1DIMU4. DIN Rail Universal Dimmer, 1 feed, 4 channels

Emergency lighting units EM powerled

1. Product Name. 2. Product Code. 3. Colour. 4. Brief Description. 5. Contents. Wi Fi Mood Lighting. As supplied

LED Driver Compact fixed output

INSTALLATION & USER GUIDE

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

AYCL253PBR Ariadni 250W Led 3WAY Dimmer Brown

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS UP TO 300 cm. of width

Panel-mounting thermostats, type series EM

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS UP TO 300 cm. of width

SQM40/41 Actuators for air and gas dampers

.Power Distribution Center. PD-1. Instruction Manual

LED Spot 300W. Please read this user manual before your operation

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

IK10 IP68. Specifications. White (4 300 K typical) Warm white (3 000 K typical) Blue (470 nm) Other colors by request

luxcontrol lighting control system DALI actuator DALI PCD one4all G2 Leading-edge/trailing-edge phase dimmer

PRE-INSTALLATION ELECTRICAL POWER GUIDE

SubstiTUBE Value ST8V-0.6m

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

LED Driver Compact fixed output

SubstiTUBE Value EM ST8V-1.2m-17W-EM

HID control gear Electronic

Tube Roller Shakers. User Guide. Version 1.2

Technical Information

LED Backlight for Technics amplifiers

Tectiv 220 Instructions for use

Cyclo DMX HO High Output. user manual

CR-6 MIXER USER MANUAL ENGLISH. Order Code: MIXE01

KNX / EIB Product Documentation. DALI Gateway. Date of issue: Order no Page 1 of 136

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS FROM 300 cm. UP TO 450 cm. of width

INSTALLATION AND OPERATION MANUAL

Concert Series ORDERCODE D3470 ORDERCODE D3471 ORDERCODE D3472 D3470 D3471 D3472

User Manual. 360W LED Moving Zoom KEEP THIS MANUAL FOR FUTURE NEEDS. 36pcs10W 4 in 1 RGBW LEDs

EC5415B. B-Tronic EasyControl. Assembly and Operating Instructions. Wall/hand-held transmitter, 15-channel, bidirectional

Digital Economy Seven Programmer

User Guide. Single-Link DVI Active Cable Extender. DVI-7171c

Catalogue Ignitors and power switches for HID

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

Timer Modules. EL11 24 Hour Module EL17 7 Day Module. Installation & Operating Instructions

SubstiTUBE Advanced UO EM ST8AU-1.5m-24W-EM

OUT. HID control gear Electronic. PCIS, PCI, PCS outdoor DIM B011 PCI outdoor

Transcription:

Operating Instructions Incandescent Lamps 1. Safety instructions Attention: Electrical equipment must be installed and fitted only by qualified electricians and in observance of the current accident prevention regulations. To prevent electric shocks, the device must be safely disconnected from the mains before performing any work on the device itself or on the load (circuit-breaker cut out). Not suitable for safe disconnection of the mains. Do not connect any electronic lamps, e.g. switchable or dimmable compact fluorescent lamps or LED lamps. Device can be damaged. Any non-observance of the fitting instructions may cause fire or other hazards. The basic brightness for use in 60-Hz-networks may be adjusted by qualified electricians only. Any unqualified tampering involves the risk of electric shocks. Only tools approved for work on devices under tension may be used for this purpose. Before performing the adjustment, it must be ensured that adjacent devices under tension (e.g. socket inserts in multiple combinations) are disconnected from the mains or if this is not possible protected against direct contact. Stand: Feb-10 325 267 13

2. Function Dimmer for incandescent lamps for switching and dimming of: 110-127 V AC incandescent lamps 110-127 V AC halogen lamps Important: The connection of transformers is not allowed. Switching and dimming is obtained by depressing and by turning the control knob. Depressing the control knob: ON OFF Turning the control knob: Dimming 3. Short-circuit protection ensured by fine-wire fuse: F 4 / 250 E In the event of malfunctions check first the fuse. Use only original fuses. 4. Installation The dimmer for incandescent lamps consists of the dimmer base (1) with cover and control knob (2) (see fig. A). Fig. A The dimmer (1) is installed in a flush-mounting box acc. To DIN 49073. Important: The overall load connected to the dimmer must not exceed 400 W. The rated maximum load can consist of a mix of the different types of load specified. A minimum load of 60 W is necessary to prevent flickering of the lamps connected. Depending on the installation, the maximum rated power must be reduced by: 10% for every 5 C above an ambient temperature of 25 C 15% for incorporation into wooden, plasterboard or hollow walls 20% for incorporation into multiple combinations Observe the technical connection requirements of the power supply companies. 2

Centralized telecontrol signals from power stations may be visible as brief flickering of the lamps in low dimming positions. The weak humming noise from the device is caused by the interference suppressor choke. Both effects are normal and do not constitute a defect of the dimmer. 4.1. Connection Fig. B The dimmer for incandescent lamps (1) is connected by means of screw terminals accessible from below. Rated load: see technical characteristics. 4.2. Two-way circuit Fig.B The mechanical two-way switch (2) can be used to switch the load on and off. The brightness of the lamp can only be varied at the dimmer itself (1). 4.3. Setting the basic brightness for use in 60 Hz networks The basic brightness is set at the factory for operation in 50 Hz networks (Europe). If the dimmer is to be used in 60 Hz net-works, the basic brightness setting must be corrected by a qualified electrician. The basic brightness must be adjusted in such a way, that a lamp switched off and a lamp turned down to minimum dimming position can be clearly distinguished. 3

Attention Observe the safety instructions 1. Disconnect the mains supply. 2. Connect the dimmer in acc. with the wiring diagram (see figs. B,C). Do not yet install in the flush-mounting box. Make sure all lines are properly insulated. 3. Switch on the mains supply. 4. Activate the dimmer by depressing the potentiometer shaft and then turn shaft fully counterclockwise (minimum dimming position). 5. Adjust potentiometer P at the side of the device (see fig. D) until the lamp burns with a basic brightness that is still perfectly visible. 6. Disconnect the mains supply. 7. Fit the dimmer in the flush-mounting box. 8. Switch the mains supply on again. 5. Technical specifications Rated voltage: Connected load: Type of loads: 110-127 V AC, 50/60 Hz 60-400 W 110-127 V AC incandescent lamps 110-127 V AC halogen lamps mixed loads of the specified types Minimum load: Fuse: Max. cross section for terminals: Two-way circuit: Basic brightness: 60 W F 4 / 250 E 2 x 2,5 mm² or 1 x 4 mm² with mechanical two-way switch Two-way circuits with 2 dimmers are not possible factory-set for 5o Hz networks, for 60 Hz networks see Setting of basic brightness As per EN 60669-2-1 (01.2000), a faint glow of the lamp should bevisible over the full load range (at rated voltage - 10 %) when the dimmer is at dark position. 4

6. Guarantee Our products are under guarantee within the scope of the statutory provisions. Please return the unit postage paid to our central service department giving a brief description of the fault: ALBRECHT JUNG GMBH & CO. KG Service-Center Kupferstr. 17-19 D-44532 Lünen Service-Line: +(49) 23 55. 80 65 51 Telefax: +(49) 23 55. 80 61 65 E-Mail: mail.vka@jung.de General equipment Service-Line: +(49) 23 55. 80 65 55 Telefax: +(49) 23 55. 80 62 55 E-Mail: mail.vkm@jung.de KNX equipment Service-Line: +(49) 23 55. 80 65 56 Telefax: +(49) 23 55. 80 62 55 E-Mail: mail.vkm@jung.de The -Sign is a free trade sign addressed exclusively to the authorities and does not include any warranty of any properties. 5