Power and Control T YPE BY RAVI GANATR November/December IAEI NEWS

Similar documents
COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

Safety Codes Council Conference Banff C Panel Discussion

Cambria County Association for the Blind and Handicapped 175 Industrial Park Road Ebensburg, PA Prepared for: Prepared by:

Continuous Currents. When inspectors see a photovoltaic (PV) power system. through Curious Cables. by John Wiles

CABLE TRAY MANUAL Based on the 2014 National Electrical Code

IndyGo Facility Upgrades Project 35671EE

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Cable Presentation for FCURT Showcase Atlanta 2011

SECTION COMMUNICATIONS HORIZONTAL CABLING

BROCHURE MC LUMINARY CABLES

Continuous Flex Data Cable

SWA Cable - BS5467 Steel Wire Armoured PVC Eland Product Group A9S

Fiberglass - Technical Data

VITALink Taped Splice Straight Through Crimp

Flygt Submersible Motor Cables

Detailed Specifications & Technical Data

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTP2-1 PLENUM RATED TUBE CABLE SERIES (NFPA 262) WITH GALVANIZED STEEL INTERLOCKED ARMORING

NCB-C6SGRYR M Category 6 STP Solid Cord. Specification. Doc. Version: /09/30

SWA Cable BS6724 Steel Wire Armoured LSZH Eland Product Group A9L

Instrumentation Cables

GenSPEED Category 5e Cables 3

Kwangil Electronic Introduction

System 500. Non-fire-rated, mineral insulated copper sheathed wiring cable

IEEE-SA SCC-18 Report by Representatives to NFPA NEC CMP-6 January 6-8, 2010 on Actions Taken on Proposals by CMP-6 for NEC 2011 ROC Prepared by

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS-2 HIGH PERFORMANCE OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX-2 OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

Scotch Heavy Duty Vinyl Electrical Tape 22

Cable installation guidelines

Detailed Specifications & Technical Data

CABLE CLEAT FAQs. Engineering Series. 1. What is a cable cleat?

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data

SECTION MEDIUM VOLTAGE CABLE INSTALLATION. 1. Section Underground Ducts and Manholes.

TRANSMISSION ENGINEERING STANDARD TES-P , Rev. 0 TABLE OF CONTENTS 1.0 SCOPE 2.0 CABLES SPLICES

Errata NFPA 70. Proposed 2014 Edition

ENGINEERING COMMITTEE

Coastal Carolina University RE-BID WILLIAMS BRICE RENOVATION AND REPAIR October 19, 2018 Construction Documents

Student Services & Classroom Addition

PEM1126ENG ENGLISH STPKR. TERMINATION KIT FOR PAPER CABLE WITH LEAD SHEATH 1 kv INSTALLATION INSTRUCTION

Cables for robot applications

ENGINEER S REPORT. of the SAFETY OF MAW COMMUNICATIONS FIBER OPTIC CABLE INSTALLATION

Electrical Installation Booklet Shipyard Standards

PRODUCT INFORMATION NYY-J, NYY-O

High Temperature Operation of Extruded Distribution Cable Systems. White Paper

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX TC01TPX (NFPA 262) PLENUM RATED TUBE

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

PRODUCT INFORMATION ETHERLINE PN FLEX. Info CPR: Article number choice under For Profinet applications Flexible use

GenSPEED 10 MTP Category 6A Cable An Unshielded 6A Cable with Superior Protection Against Alien Crosstalk

TECHNICAL SPECIFICATION

File E Project December 11, 2013 REPORT DRIVERS FOR LIGHT-EMITTING DIODES ARRAYS MODULES AND CONTROLLERS

PEM1124ENG ENGLISH. STK TERMINATION KIT FOR PLASTIC CABLE WITHOUT ARMOURING 1 kv STKR TERMINATION KIT FOR PLASTIC CABLE WITH ARMOURING 1 kv

Flame-retardant cable for

FREEDM Loose Tube Interlocking Armored Cables

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS DIELECTRIC HIGH PERFORMANCE OSP TUBE CABLE SERIES

AGENDA. NEC Code-Making Panel 16. Report on Comment Meeting. December 3-December 8, Redondo Beach, CA

CONTENTS. Product Guide 1. Multi Conductor Cable 11. Paired Cable 20. RS-232 Application Cable 27. RS-422 Application Cable 28

Detailed Specifications & Technical Data

About Nexans 3. About Berk-Tek 4. Hyper Plus 5e Cat 5e UTP 5. HyperPlus 5e Plenum 6. Hyper Plus 5e Riser 10. HyperPlus 5e Patch 14

Installation Guide VL-MV10. Model No.

A Comparison of Dry Versus Gel Filled Optical Cables

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX / TOD DIELECTRIC OSP TUBE CABLE SERIES

BUS UNITRONIC BUS CAN

CHAPTER 14 WIRING SIGNALS AND LIGHTING FIELD GUIDE Wiring Requirements WIRING

An Urgent Bulletin from CSA Group

AMERICAN NATIONAL STANDARD

UNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE

Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

SAQCC FIRE D&GS TRAINING SUB COMMITTEE COURSE CURRICULUM

AGENDA. NEC Code-Making Panel 16. Report on Proposal Meeting. Jan. 9-14, Hilton Head, SC

Flexible Cord. Inside this section

Target Interface / Construction Compliance Inspection Checklist

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

ADDENDUM #3. SPECIAL NOTE: Addendum #3 information shall supersede the information contained in the Contract Documents

TERMINATIONS AND JOINTS FOR XLPE-INSULATED kv MEDIUM VOLTAGE CABLES

GIGALAN AUGMENTED CABLE CAT6A F/UTP 23AWGX4P LSZH

Insulated Cable Engineers Assoc., Inc. Publication No. ICEA P NEMA Standards Publication No. WC

Continuous High-Flex Cable for Automated Systems

OCC Installation Conduit Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

ENGINEERING COMMITTEE Interface Practices Subcommittee. ANSI/SCTE (Formerly IPS SP 001)

Sumitomo Cable Specification SE-*RU. OFNP Rated Central Tube Cable with Optical Fibers. Issued: December 2014

ELECTRICAL SAFETY INSPECTION REPORT

TECHNICAL DATA. Type. TMC2X Design Specification. Category B ATEX Certificate. Code of Protection. IECEx SIR X Code of Protection

Detailed Specifications & Technical Data

TES Construction Standards 17 Instrumentation. Revision #: 2.6 Document #: CS17002 Page: 1 of 15 Title: Instrumentation Electrical Installation

INSTRUCTION DE SÉCURITÉ SAFETY INSTRUCTION Mandatory as defined in SAPOCO/42 FIRE PREVENTION FOR CABLES, CABLE TRAYS AND CONDUITS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Public Works Division Lighting District Fiber Optic Specifications April 2009

STRUCTURED CABLE SYSTEM (SCS)

SPECIAL SPECIFICATION 8540 Telecommunication Cable

FLAT AND ROUND CABLE PRODUCT DESCRIPTION DESIGN ADVANTAGES. IDC Systems Cable

UFGS (August 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONS

Purchase Now ANSI/ICEA S

Instrukcja montażu. FLEX LED Neon Instalacja

Instructions. Cable with Armor F CAUTION. October Rev A

SECTION 7 -- CROSS-CONNECT SYSTEMS

CONSTRUCTION SPECIFICATION FOR TRAFFIC SIGNAL EQUIPMENT

OPTICAL FIBRE CABLES. for very-high bit transmission and FTTx networks

Tab 10 - The NESC and Underground Applications. Restricted Siemens Industry, Inc All rights reserved.

KRF EMC Filters Installation, Operation and Maintenance Manual

FLUID VIEW 12V LED TAPE LIGHT

Transcription:

Power and Control 26 1999 November/December IAEI NEWS T YPE BY RAVI GANATR

This article discusses how the requirements in both the installation code and the product standard are utilized to manufacture and install power and control tray cable, Type TC, products that are suitable for various applications. Where appropriate, alternate wiring methods are identified to provide some useful comparison. Tray Cable: TC A Also, some of the applicable requirements in Canada and Mexico 1 are identified and discussed to provide a North American perspective. IAEI NEWS 1999 November/December 27

Installation and Applications Requirements Table 1 (pages 32-34) provides a brief comparison of installation and applications requirements for Type TC tray cables in Canada and the US. Significant requirements for product recognition and application are identified. Since Type TC cables are typically used in cable trays, references related to cable trays are also identified. For complete details, references provided in the table should be consulted. In the US, the National Electrical Code (NEC), NFPA 70 standard, recognizes various types of wire and cable products and also defines requirements for their uses and installations for intended applications. Most, if not all, of these products are manufactured and listed in accordance with applicable product standards, generally developed by the Underwriters Laboratories (UL). Article 318 defines cable trays, in 318-2. Cable tray installations are used more commonly in industrial establishments to provide flexibility in wiring of process equipment. In accordance with 318-3, cable tray installations are not limited to industrial establishments. However, single conductor cables, provided they are identified for use in cable trays, are limited to industrial establishments only in accordance with 318-3(b)(1). Article 340 of the NEC recognizes Type TC products and defines requirements for their uses and installations in cable trays, in raceways, or where supported by a messenger wire. UL Standard 1277, Electrical Power and Control Tray Cables with Optional Optical- Fiber Members, defines prescriptive and performance requirements for Type TC products. For their use in cable trays, the suitability of single conductor cables, which are recognized in Table Photo 1 (top): Ladder-type tray supporting conduit at transition. Photo 2 (right): Transition from EMT to cable tray communications circuits. 28 1999 November/December

310-13, is evaluated in accordance with their respective product standards. In Canada, the Canadian Electrical Code (CEC) Part I, CSA Standard C22.1, recognizes various types of wire and cable products and also defines requirements for their uses and installations for intended applications. All of these products are manufactured and listed in accordance with applicable product standards listed in Appendix A of the CEC Part II. 2 These standards are developed by the Canadian Standards Association (CSA). In Canada, a cable tray is considered a raceway. Unlike US, Type TC tray cables can be either single or multi-conductor product in accordance with CEC. Also, tray cable in Canada also includes medium voltage power cables. Type TC tray cables shall be permitted in cable trays only in areas of industrial establishments that are inaccessible to the public, as an alternate to the main rule which requires that the conductors used in cable trays in all areas shall have a continuous metal sheath or interlocking armor. Similar to US, single conductor Type TC tray cables shall not be smaller than 1/0 AWG. Cable trays provide the needed flexibility in circuit layouts in various industrial establishments, such as those found in petro-chemical, pulp and paper, textile, mining, etc. Wire and cable products used in various non-raceway applications in these industries require superior mechanical, flame test, and cold temperature handling properties. Armored cables, such as Type MC Cables in US and Types AC90, ACWU90 and TECK90 in Canada, have been the primary choice for these applications. This is because these products can be installed by themselves or in cable trays. Type TC cables require a protection when outside of the cable trays while armored cables may not require such protection in most cases. Inherent construction design of armored cables provides a better Photo 3 (top) and Photo 4: Ladder-type cable tray and conduit supports at transition points. IAEI NEWS 1999 November/Decem-

Ladder-type cable tray with external equipment grounding conductor connected. opportunity to attain higher levels of mechanical performance, flame test performance for the overall cable construction, a higher level of insulating properties for the conductor insulation, and a higher level of cold temperature properties for the cable. Similar level of achievement is difficult with Type TC products, especially when the jacket alone cannot provide the needed performance for all different needs. Additional applications, such as for control and signal circuits, of Type TC cables are identified in Table 1. The installation requirements for various wire and cable products in cable trays are provided in the code references for cable trays in Table 1. In particular, these references should be consulted for clearances between the cable trays, spacing of conductors and cables within a cable tray, securing of conductors and cables within a cable tray, etc. These installation requirements for cable trays determine permitted ampacity for conductors and cables installed in a given cable tray. Mechanical loading of trays is also a critical factor for proper installation of cable trays. In general, Type TC tray cables provide an advantage over heavier armored cables. Generally, the weight of these products would decrease in the following order: armored cables with copper conductors, tray cables with copper conductors, armored cables with electrically equivalent size aluminum conductors, and tray cables with electrically equivalent size aluminum conductors. Construction and Performance Requirements Table 1 also provides a comparison of the construction and performance requirements for Type TC tray cables in two countries. With few exceptions, the requirements are very similar. Typical constructions of Type TC with three and four conductors with an equipment grounding conductor for power applications are shown in Figures 1 and 2 (page 31). Insulated conductors recognized in Table 310-13 of the NEC are cabled together with or without the equipment grounding conductor and fillers. Conductor types used most commonly for 600 V rated Type TC products include THHN/THWN, XHHW, and RHH/ RHW. For 2000 V rated Type TC products, conductor types used include RHH/RHW recognized in Table 310-62 of the NEC. A separator tape is used to wrap the assembly of conductors. An overall jacket is then applied over the assembly. Materials for conductor insulation, fillers, tapes, and jacketing play an important role in delivering the required performance in accordance with the listing requirements, optional requirements, customer specifications and industry practices for Type TC products. A balance between the electrical, mechanical and flame test properties of the insulation type; mechanical and flame test properties of the overall construction; and required optional performance capabilities is arrived at by the users in various industrial establishments for their specific needs. Construction capable of meeting the requirements for a higher level of low temperature handling, a higher level of vertical flame test, for a lower level of acid gases, etc., is different than the construction capable of meeting the normal requirements for the same properties. 30 1999 November/December

Stabiloy Type TC 3 Conductor with Ground Compact Stabiloy Grounding Conductor Fillers Tapes PVC Outer Jacket XLPE Insulation Compact Stabiloy Phase Conductor Figure 1. Stabiloy Type TC 4 Conductor with Ground Compact Stabiloy Grounding Conductor Fillers Tapes PVC Outer Jacket XLPE Insulation Compact Stabiloy Phase Conductor Figure 2. IAEI NEWS 1999 November/Decem-

Requirements for Type TC cables in accordance with the NEC and the CEC NEC CEC General Requirements Description Reference Requirement Description Reference Requirement Cable Tray System 318-2. Definition. A unit or assembly of units or sections and associated fittings forming a structural system used to securely fasten or support cables and raceways. Cable Tray Section 0, Object, Scope And Definitions Cable tray means a raceway consisting of troughing, and fittings therefore, so formed and constructed that insulated conductors and cables may be readily installed or removed after the cable tray has been completely installed, without injury either to conductors or their coverings. Recognized Wiring Methods for Cable Tray Systems 318-3 (a) and (b) Multi-conductor Type TC cables are recognized in 318-3(a) as one of many permitted wiring methods for Cable Tray Systems. For industrial establishments, 318-3(b) permits single conductor cables No. 1/0 or larger (and, No. 4 or larger for grounding) that are marked For CT Use. Conductors in Cable Trays 12-2204 (2) Type TC tray cables shall be permitted (as an alternate to requirement in 12-2204 (1)) in cable trays in areas of industrial establishments that are inaccessible to the public. Single conductor Type TC tray cables shall not be smaller than 1/0 AWG. Type TC Article 340 Power and Control Tray Cable: Type TC Type TC Table 19, Section 12 and other specific rules. No specific article for Type TC. Definition 340-1. Definition. Type TC power and control tray cable is a factory assembly of two or more insulated conductors, with or without associated bare or covered grounding conductors under a nonmetallic sheath, for installation in cable trays, in raceways, or where supported by a messenger wire. Definition No specific definition. Per CEC and CSA Standard C22.2 No. 230 Tray Cables, it can be a single conductor (1/0 AWG and larger) or a factory assembly of two or more insulated conductors, with or without associated bare or covered grounding conductors under a nonmetallic sheath, for installation in cable trays. Listing In accordance with UL Standard 1277, Electrical Power and Control Tray Cables with Optional Optical-Fiber Members. Single conductor cables, which are recognized in Table 310-13, are evaluated in accordance with their respective product standards for their use in cable trays and marked For CT Use. Listing In accordance with CSA Standard C22.2 No. 230 Tray Cables. Table 1. Summary Examination of code and standards requirement in North America suggests that the interactive system of Code-Product Standards-Verification provide a set of choices for wiring methods in demanding environments in the industrial establishments. Power and Control Tray Cable Type TC products can be used successfully in many applications in these environments. It is also clear that there is no single construction of Type TC that is suitable for all possible applications. Selection of a specific design depends upon the installation conditions and the required product performance characteristics for a particular application. Also, versatility, availability, and costs of alternate wiring methods, such armored cables and conductors in raceways, are compared against the similar features of Type TC cables and associated cable tray installation. RAVINDRA H. GANATRA Ravindra H. Ganatra is a senior engineer for distributor products at Alcan Cable s head office in Atlanta, Georgia. Ravi has been involved in several areas of wire and cable manufacturing, including: product, process and materials development; product applications; and codes and standards development activities in ASTM, CANENA, NEMA, NFPA, and UL. He is a principal member of CMP-6 and an alternate member of CMP-7 of the NEC. 1 The installation code (NOM-001-SEMP-1994) recognizes Type TC products in Article 340. However, it is being revised and at present time there is no known product standard in place for Type TC products in Mexico, limited information from Mexico is presented here. Since the installation code in Mexico is likely to remain similar to the NEC, it also likely that the product standard, when developed, for Type TC products will be similar to UL 1277. 2 In Canada, Appendix A in CEC Part II is an integral part of the Code. 32 1999 November/December

Applications and Installation Requirements Uses Permitted 340-4 1. For power, lighting, control, and signal circuits. 2. In cable trays, or in raceways, or where supported in outdoor locations by a messenger wire. 3. In cable trays in hazardous (classified) locations as permitted in Articles 318, 501, 502, 504, and 505 in industrial establishments where the conditions of maintenance and supervision ensure that only qualified persons will service the installation. 4. For Class 1 circuits as permitted in Article 725. 5. For nonpower-limited fire alarm circuits if conductors comply with the requirements of Section 760-27. 6. In industrial establishments where the conditions of maintenance and supervision ensure that only qualified persons will service the installation, and where the cable is not subject to physical damage, Type TC tray cable that complies with the crush and impact requirements of Type MC cable and is identified for such use shall be permitted as open wiring in lengths not to exceed a total of 50 ft (15.24 m) between a cable tray and the utilization equipment or device. The cable shall be supported and secured at intervals not exceeding 6 ft (1.83 m). Equipment grounding for the utilization equipment shall be provided by an equipment grounding conductor within the cable. Uses Permitted Table 19 Tray cables are recognized for use in raceways including ventilated, non-ventilated, and ladder type cable trays in wet locations and where exposed to whether. 12-2204 (2) Type TC tray cables shall be permitted in cable trays in areas of industrial establishments that are inaccessible to the public provided the cable is: (a) Installed in conduit, other suitable raceway, or direct buried, where not in cable tray; and (b) Provided with mechanical protection where subject to damage either during or after installation; and (c) No smaller than 1/0 AWG if a single conductor is used; and (d) Installed only where qualified persons service the installation. Table 19 and (18-068, 18-156, and 18-252) For use in cable trays in Class I Division 2 and Class II Division 2 hazardous locations. Table 19 Type TC cable directly buried in the earth shall be marked as suitable for the purpose. Uses Not Permitted 340-5 1. Installed where it will be exposed to physical damage 2. Installed as open cable on brackets or cleats 3. Used where exposed to direct rays of the sun, unless identified as sunlight resistant 4. Direct buried, unless identified for such use. Uses permitted rules include (or preclude) conditions for uses not permitted. Bends 340-8 Bends in Type TC cable shall be made so as not to damage the cable. No specific reference for Type TC. Bending Radius None specified. None specified. Ampacity 340-7 The ampacities of the conductors of Type TC tray cable shall be determined from Section 402-5 for conductors smaller than No. 14 and from Section 318-11. 12-2212 Similar to the requirements in 318-11, the ampacities of the conductors of Type TC tray cable is determined in accordance with various provisions for installation of Type TC cable in cable trays. IAEI NEWS 1999 November/Decem-

UL 1277 Construction and Performance Requirements CSA Standard C22.2 No. 230 Tray Cables Construction Consists of two or more current carrying circuit conductors with or without either or both of the following, all under an overall jacket: a) One bare or one or more insulated grounding conductor(s), and b) One or more individually jacketed optical-fiber members. Construction Details of construction are not published in this Standard because the test and marking requirements of this Standard are in addition to the basic requirements for the cable construction that appear in other published CSA Standards. Except for single conductor products being marked Type TC, construction is similar to Type TC in the US. Conductors Copper (Sizes # 14 AWG and larger depending upon other specific requirements). Aluminum or copper clad aluminum (Sizes # 12 AWG and larger depending upon other specific requirements). Copper (Sizes # 16 - # 18) for control conductors. Conductors Copper (Sizes # 14 AWG and larger depending upon other specific requirements). Aluminum (Sizes # 12 AWG and larger depending upon other specific requirements). Copper (Sizes # 16 - # 18) for control conductors. Equipment Grounding Typically included. Same voltage rating as the circuit conductors. Equipment Grounding Typically included. Same voltage rating as the circuit conductors. Insulation Typically: Thermoplastic: Per UL 83 (600 V) wet and or dry ratings. (Ex: THW or THHN/THWN) Thermoset: Per UL 44 (600 V or 2000 V) wet and dry ratings. (Ex: XHHW (600 V) or RHH/RHW (2000 V)) Other: Control conductors per UL 62 Standard and or optical fiber member(s) in 600 V Tray Cables. Insulation Typically: Thermoplastic: Per CSA C 22.2 No. 75 (600 V) wet and or dry ratings. (Ex: TW or T90 (dry only)) Thermoset: Per CSA C 22.2 No. 38 (600 V or 1000 V) wet and dry ratings. (RW90 (600 V) or RW90 (1000 V) Tray cable in Canada also includes medium voltage power cables. Other: Where permitted, control conductors and or other assemblies per other CSA Standards. Temperature Rating Temperature rating of conductor insulation. Temperature Rating Temperature rating of conductor insulation. Sheath Thermoplastic or thermoset. Properties of sheath and conductor insulation along with the assembly contribute towards the capability of the construction to meet the required flame test and other physical performance requirements. Sheath Thermoplastic or thermoset. Properties of sheath and conductor insulation along with the assembly contribute towards the capability of the construction to meet the required flame test and other physical performance requirements. Vertical-Tray Flame Test Per UL 1277 (UL 1581). Protocol is also known as IEEE 383. FT 4 Vertical- Tray Flame Test Per C22.2 No. 0.3. Protocol is also known as IEEE 1202 and considered more severe than IEEE 383. Other required tests include Cold Bend Test (-25º C), Deformation Test of Jacket, Heat Shock Test of Thermoplastic Jacket, etc. Other required tests include Cold Bend (-25º C), Impact Test, Crushing Test, Cold Impact Test, Weather Resistance Test, etc. Marking Type TC, conductor size, conductor material (where required), voltage rating, identification for ungrounded and grounded conductors, color of insulated grounding conductor, temperature rating (where required), etc. Marking Type TC, conductor size, conductor material (where required), voltage rating, identification for ungrounded and grounded conductors, color of insulated grounding conductor, temperature rating (where required), etc. Optional Markings FT 4 Vertical Tray Flame Test Cold Impact (-40º C) Open Wiring: Type TC shall meet crush and impact requirements for Type MC Sunlight-Resistance Direct Burial VW-1, oil-resistant, gasoline-resistant, reagent-resistant, or other individual conductor use may itself be identified on the tag, reel, or carton. Cold Impact (-40º C) (Typically preferred) Low Acid Gas (LAG) (Not a requirement in the CEC or Standards but, complied commercially in most cases.) 34 1999 November/December