Arc-fault Protection System

Similar documents
Arc Detecting and Protection System

CAMTO LTD. Arc detecting system DC/AC

Installation Instructions. What This Option Provides

Global pay TV revenues crawl to $200 billion

Troubleshooting Analog to Digital Converter Offset using a Mixed Signal Oscilloscope APPLICATION NOTE

Speed sensor MiniCoder GEL 2471

DFT. Compact Paddle Flow Sensor

NEW. Cable/Pipe sizes. InsertStrip. MainBlock

DFT. Rotating Vane Flow Meter, Counter, Doser. for liquids l/min. Measuring accuracy: 2.5% f. s. : 16 bar; t max

More light, less power comsumption. Living with

Supplemental Information. Form and Function in Human Song. Samuel A. Mehr, Manvir Singh, Hunter York, Luke Glowacki, and Max M.

W 9-2: A Versatile, Complete and Compact Series

BFI RESEARCH AND STATISTICS PUBLISHED AUGUST 2016 THE UK FILM MARKET AS A WHOLE. Image: Mr Holmes courtesy of eone Films

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

How-To Guide. LQV (Luminance Qualified Vector) Measurements with the WFM8200/8300

Generator protection relay

Agilent 87405C 100 MHz to 18 GHz Preamplifier

OVZ. Economical Oval-Gear Flow Meter. For Viscous Oils

The Great Transition: Shifting from Fossil Fuels to Solar and Wind Energy Supporting Data - Climate

PatternPro Error Detector PED3200 and PED4000 Series Datasheet

40 Gb/s PatternPro Programmable Pattern Generator PPG4001 Datasheet

TV-1800 PCTV Tuner Product information Connection. Control Panel

247E4.

Capacitance Limit Detection nivotester FTC 420/421/422

Technical Specifications

Luminaire installation box Surface-mounted box Ceiling installation box

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Quick Signal Integrity Troubleshooting with Integrated Logic Analyzers & Oscilloscopes

REPORT ON THE STATUS OF CONTRIBUTIONS TO THE CORE BUDGET FOR THE BIENNIUM Note by the secretariat

Lt DELTA USA, Inc

STX Stairs lighting controller.

High performance circuit breakers

02/11/2015

Assembly. Front view. LEDs. Parametrization interface. Power Bus

THE BEAUTY OF THE INFLATABLE SCREEN

190V3.

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Agilent 87075C 75 Ohm Multiport Test Sets for use with Agilent E5061A ENA-L Network Analyzers

THE BEAUTY OF THE INFLATABLE SCREEN

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

Multi Content Market Japan Content Showcase Features of Japan Content Showcase JCS. Online Library. TIMM & Showcase Live TIMM & Free Service

Black and Frozen Frame Detection

testing to perfection MultiTest-dV Precision tension & compression tester with VectorPro Lite data acquisition software

Obsolete Product(s) - Obsolete Product(s)

Aspect 2 Circuit Digital Scene Control

Automatic Changeover Unit ECO8000 Datasheet

Identifying Setup and Hold Violations with a Mixed Signal Oscilloscope APPLICATION NOTE

INSTALLATION & USER GUIDE

Video Quality Monitors Sentry Edge II Datasheet

40 Gb/s PatternPro Programmable Pattern Generator PPG4001 Datasheet

Obsolete Product(s) - Obsolete Product(s)

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

GP-500 SERIES - Low Voltage

Process transmitter RMA422

DATA SHEET. Synchronisers, FAS-113DG ANSI code 25

Keysight Technologies N4974A PRBS Generator 44 Gb/s. Data Sheet

Tektronix Logic Analyzer Probes P6900 Series Datasheet for DDR Memory Applications

Pressure Sensors SPAB, with Display

Agilent 86120B, 86120C, 86122B Multi-Wavelength Meters. Data Sheet

CURRENT INJECTION RELAY TESTER CR-100. ( Code P60212 (770081) ) INSTRUCTIONS MANUAL ( M / 05A ) (c) CIRCUTOR S.A.

Logic Analyzer Triggering Techniques to Capture Elusive Problems

Figure 1: Device components

INNOVATION IN MAGNETICS DS3434/5. Mag612. Miniature Three-Axis Fluxgate Probe.

Obsolete Product(s) - Obsolete Product(s)

Automatic Changeover Unit ECO8020 Datasheet

Series CT7N Bimetallic Overload Relays

Coverage analysis of publications of University of Mysore in Scopus

The diversity of films screened at the cinema: A comparison of evidence from different national cinemas

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5

Bio-Rad Imaging Systems Family

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

Heating thermostat Series AMHs B Operating Instructions 11.06/

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

OP5. Preprogrammed, configurable controller for simple applications

8000 Plus Series Safety Light Curtain Installation Sheet ( CD206A/ CD206B )

Products according to UIC 552

46 GBaud Multi-Format Optical Transmitter

Keysight Technologies High-Power Measurements Using the E5072A ENA Series Network Analyzer. Application Note

Order code Package Connection. SPDC400FC12M0.60 Open frame Comb. October 2007 Rev 1 1/9

Innovation in Magnetic Field Measuring Instruments. Magnetometer Power Supplies

Spearhead Display. How To Guide

Multi-channel LED driver with integrated boost controller for medium, large LCD panel backlight based on LED7708 and STM32F103C6T6A

Process Transmitter RMA 422

FILM EXPO GROUP MEDIA KIT. FilmExpoGroup

Simply clever! The digital DIN-rail time switches by Grässlin

Obsolete Product(s) - Obsolete Product(s)

STEVAL-IHM025V1. 1 kw 3-phase motor control demonstration board featuring the IGBT SLLIMM STGIPL14K60. Features. Description

Tri-level Control HF Sensor

Electrical Sampling Modules Datasheet 80E11 80E11X1 80E10B 80E09B 80E08B 80E07B 80E04 80E03 80E03-NV

IMPAC Infrared Thermometers

BUL1203EFP HIGH VOLTAGE FAST-SWITCHING NPN POWER TRANSISTOR

Wall-/Pipe-Mount Level Indicator

10 SERIES. Light dependent relays A

Low Cost, High Speed Spectrum Analyzers For RF Manufacturing APPLICATION NOTE

Gamma instabus. Technical product information

Keysight Technologies Multi-Channel Audio Test using the Keysight U8903A Audio Analyzer

WF next: Fork sensors for a wide range of applications

Debugging Memory Interfaces using Visual Trigger on Tektronix Oscilloscopes

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description

Electronic Pulse Counter Combination device

Transcription:

Short Form Catalogue Arc-fault Protection System Protection of Switchboards Improve personnel safety. Minimize production down time. Reduce damage to material and the cost of repair or replacement. Arcing faults in switchboards can cause severe damage against material as well as personnel. The main issue is that no two arcing are the same, and it is therefore very difficult to know in advance how to prevent them. Whenever arcing occurs the pressure generated by the rapid increase in temperature is strong enough to break off cabinet doors. Further the light of the arcing, ultraviolet, and infrared, is dangerous for personnel, eyes and skin. All of the above points should be taken into consideration in the Total Cost of Ownership, TCO, of a switchboard, and by using the SELCO Arc Detecting Relays you will be able to reduce these costs and eliminate the points listed.

Arc-fault Protection System The SELCO Arc-fault Protection System is based on experience with arc protection since 1962. The system units are built into boxes all fitting 35mm DIN-rails. Front plates are dimensioned to fit into the 45mm slot in the cover plates of a DIN-system. The Arc Detecting Relay is connected to light sensiti ve detectors suitably placed in the various cubicles or drawers inside the switchboard. The Overcurrent Relay is used if overcurrent protection is required as well. Arc Detecting Relay/ Current Relay/Time Relay To be placed in the switchboard or in connection with it. It is recommended that the Arc Detecting Relay, the Current Relay and the Time Relay are installed in the relay box or otherwise separated from the circuit breaker to be tripped. Junction box for parallel connection To be installed considering the length of the detector cables (5 metres). Junction boxes with indication are installed so that the LED s are fully visible. Max. 2 junction boxes per Arc Detecting Relay. Arc Detectors Installation: 1-2 pcs. per cu bicle or drawer, see drawings on page 4. At horizontal/vertical bus bars (1) and in breaker/cable compartments (2). 2

Arc-fault Protection D0100 Arc Detecting Relay for 24-220V DC battery supply D0400 D0500 D0700 The D0100 is a detecting relay which can monitor up to 16 arc detectors in parallel through D0400 or D0500 Junction Boxes. In case of an arcing fault, the relay generates a fast tripping pulse, less than 1msec., to the circuit breaker(s) supplying the installation. The arcing time is thus reduced to the mechanical opening time of the circuit breaker, The relay is solid state with complete isolation between input and output. Thus the relay and the circuit breaker may have different pilot voltages. The TEST-position on the relay is used to test the tripping without opening the circuit breaker. The 2 free signal contacts is for remote indication of arcing fault trip and indication for absence of pilot voltage - or for indication of the TESTfunction is activated. The sensitivity to light is adjustable on the front plate SENS.ADJ knob within 1-12mA. The range is 2.000-24.000lux enabling you to use the sensors under different light conditions, indoor light, sunlight etc. The preset is 6mA/12.000lux. D0400 Junction Box D0900 The D0400 is for connection of up to 8 detectors in parallel without indication. A0200/A0300 Detector D0900 D0400 D0500 The A0200/A0300 both reacts on light and is available with 180º or 360º characteristic. To be installed in each cubicle/ drawer and should be shielded from normal switching arcs. Detectors are supplied with 5m, 10m or 15m of cable and a mounting bracket. D0900 Arc Detecting Relay for AC supply D0400 The D0900 is a detecting relay which can monitor up to 16 arc detectors in parallel through D0400 Junction Box. In case of an arcing fault, the relay generates a fast tripping pulse, less than 1 msec., to the circuit breaker(s) supplying the installation. The arcing time is thus reduced to the mechanical opening time of the circuit breaker, The relay is solid state with complete isolation between input and output. The relay has energy stored in a storage capacitor charged with a DC voltage to trip the circuit breaker. The TEST-position on the relay is used to test the tripping without opening the circuit breaker. The 2 free signal contacts are for remote indication of arcing fault trip and indication for absence of pilot voltage - or for indication of the TEST-function is activated. Both contacts are activated after tripping as the relay normally disconnects its own supply voltage. The sensitivity to light is adjustable on the front plate SENS.ADJ knob within 1-12mA. The range is 2.000-24.000lux enabling use of sensors under different light conditions, indoor light, sunlight etc. The preset is 6mA/12.000lux. 3

Arc-fault Protection D0500 Junction Box with Indication The D0500 is designed to connect up to 8 detectors in parallel and has a separate indication of which detec-tor(s) caused tripping by means of a red LED for each detector. The red LED is lit when the light intensity exceeds 6.000lux. on the detector, but it turns off again if the intensity goes below 6.000lux. At 12.000lux. the arc detecting relay is triggered, the active LED s are latched and a yellow LED (TRIP) is turned on. All LED s remain turned on until reset by a common RESET button. Max. 2 boxes per arc detecting relay is allowed D0700 Overcurrent Relay The D0700 is a 3-phase current relay to be used in combination with a DC arc detecting relay. The current setting range is 1.5-3.0 x In (7.5-15A). Each time the set current is exceeded a red LED (TRIP) turns on and an output relay activates. The relay contact - normally closed - opens and cancels the blocking of the arc detecting relay making it able to trip the supply breaker in the case of an arcing fault. The function of the arc detecting relay is thus made dependent on the current at the time of the arcing fault. However arcing time is increased. Connection Possibilities A0200 Detector A0300 Detector D0100 Arc Detecting Relay DC D0400 Junction Box D0500 Junction Box w/indication D0700 Overcurrent Relay D0900 Arc Detecting Relay AC A0200 A0300 D0100 D0400 D0500 D0700 D0900 4

Specifications SELCO Arc-fault Protection System D0100 - Arc Detecting Relay DC Voltage Supply: Triac output: 24-220V DC from battery. 250V AC/DC, 8A cont. 25A/ 0.1sec. Min. load current 50mA. Signal contacts: 2 free/220v AC/DC 1A max. 50W. Sensitivity: Number of detectors: Response time: Power consumption: 1-12mA, pre-set trip 6mA/12000 lux. Max. 16 pcs. Less than 1msec. 4.3W. Ambient temperature: -25 to +70º C. Light intensity from an arc current of min. 3kA detected inside of the curves will trip the breaker. D0500 - Junction Box with indication Power consumption: Ambient temperature: 0.6W. -25 to +70ºC. A0200, 180 degrees A0300, 360 degrees D0700 - Overcurrent Relay Voltage Supply: 48-220V DC from battery. Current inputs: 3-phase 5A cont., 75A /1sec. Burden: 0.5VA/input at 5A. Current range: 1.5-3.0 x In (7.5-15A). Response time: 20-30 msec. Power consumption: 2.6W. Ambient temperature: -5 to +55ºC. D0900 - Arc Detecting Relay AC Voltage Supply: 220-250V AC. Thyristor output with stored energy: Storage capacitor 66 µf charged to 300V DC. E=2.97Wsec. (Joule). Life time min 30 years at 50 C. Min. load current 50mA. Charging time approx. 1 sec. Discharge time approx. 1 min. Trip coil: 230V AC. Signal contacts: 2 free, 230V AC/DC 1A max.50w. Sensitivity: 1-12mA, pre-set trip 6mA/12000 lux. Number of detectors: Max. 16 pcs. Response time: Less than 1 msec. Power consumption: 3.5 W. Ambient temperature: -25 to +70ºC. Environment EMC standards: Enclosure: Dimensions The specifications are subject to change without notice. EN50081-1/2 and EN50082-1/2. IP31. Item no. Dim. mm B H D1 D2 D3 D4 D0100 105 90 75 70 60 49 D0900 105 90 75 70 60 49 D0400 72 90 58 48 D0500 72 90 70 58 48 D0700 105 90 60 49 D0800 72 90 75 70 58 48 5

SELCO Worldwide SELCO Denmark SELCO Subsidiary SELCO Representation and area of supply Belgium Brazil Bulgaria Canada Chile China Croatia Egypt Finland France Germany Greece Iceland India Indonesia Iran Italy Japan Lebanon Malaysia Mexico Netherlands New Zealand Norway Pakistan Peru Philippines Poland Portugal Romania Russia Singapore South Africa South Korea Spain Sri Lanka Sweden Taiwan Thailand Turkey United Kingdom U.S.A. Main Office: SELCO A/S Betonvej 10 DK- 4000 Roskilde Denmark Phone: + 45-70 26 11 22 Fax: + 45-70 26 25 22 e-mail: selco.dk@selco.com www.selco.com Q1004-81UK