Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

Similar documents
Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

Product Catalog Electric Drives and Controls. Frequency Converters IndraDrive Fc

Product Catalog Electric Drives and Controls. Frequency converter IndraDrive Fc

Electric Drives and Controls Product Catalog. Frequency converter IndraDrive Fc

Frequency Converter Fv

Frequency Converter EFC 3610, EFC 5610

Frequency Converter EFC 3610, EFC 5610

Product Catalog Frequency Converters

Basic, cost-effective motor control in one unit: MOVITRAC 07.

Frequency Converter EFC 3610, EFC 5610

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

AF-300 E11 Adjustable Frequency Drive

Operating temperatures from 20 C ( 4 F) up to 50 C (122 F). Up to 70 C (158 F) with current derating and optional control module fan kit.

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

2000 W, 2450 MHz Microwave Generator GMP 20K SM 56M230 FST 3 IR

BOSTON GEAR CONTROLLERS. ACE 10 Series 1/4 through 3 HP Adjustable Frequency AC Motor Controllers MEX (55) QRO (442)

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

REO vibratory conveyor technology Solutions for your vibratory conveyors

Rexroth GDS/GDM1.1 Digital Singleturn/Multiturn Encoder

For applications from 0.25 to 5 HP, the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted.

MICROMASTER Encoder Module

Siemens Industry Online Support

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

Generator protection relay

Absolute Encoders Multiturn

english SGC inverter series hf transformer input voltage up to 800 V touch screen built-in data loggers

LASER. Laser-Position-Transducer. LLD Series. Key-Features:

EMC Solutions Noise filtering

Digital 4 Q - Servo amplifier for brushless DC Servo motors (Trapeze)

Fibre Optic Modem ODW-611

LASER. Laser-Position-Transducer. LLD-150 Series. Key-Features:

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Variable speed drives Altivar 38 Mastering elements for more comfort

VAT 20 Adjustable Frequency Drive

LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56

ROTARY ENCODER SELECTION. A Step by Step Guide

OPTOTRONIC Intelligent

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

Set for simple I/O communication via PROFIBUS-DP in IP20 TI-BL20-DPV1-S-8

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

PRINCIPLES AND APPLICATIONS

Product Information. EIB 700 Series External Interface Box

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

Absolute encoders multiturn

CML 700i Measuring light curtain with integrated control unit and interfaces for even simpler operation

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Bulletin 150, 154 Softstarters Quick Selection Table

Process Transmitter RMA 422

Electric Rotary Modules. Rotary Actuators

istep STEPPER MOTOR PUMP

POSIWIRE. WS61 with internal magnetic encoder Position Sensor. Cable Extension Position Sensors. Datasheet

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

System Interface Unit SIU-100/100T

BL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC

Roof-mounted Blue e+ cooling unit Integration solution VX25

HiPace 300 with TC 110 and power supply OPS 100, DN 100 ISO-F

SRV02-Series. Ball & Beam. User Manual

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Flexible. Fast. Precise. PPU-E Pick & Place Unit

Lt DELTA USA, Inc

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

Process transmitter RMA422

DRS61: Incremental encoders, number of lines and zero pulse width freely programmable DRS60: Incremental Encoders with Zero-Pulse-Teach

Model KT 53 Cooling incubators with thermoelectric cooling

Direct PWM. 1000/2000 Series POWERBLOK MODULE

Speed sensor MiniCoder GEL 2471

Fibre optic router for TP/FT-10 LRW-112PP

istep STEPPER MOTOR PUMP

IS 140 IGA 140 IS 140-PB IGA 140-PB IS 140-PN IGA 140-PN IS 140-ET IGA 140-ET

Presentation 2 for asynchronous motors 2

CNC. IndraMotion MTX micro Up to 12 axes

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

Accessories. Servo Motors. Servo Motors B-47. Accessories

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

IMPAC Infrared Thermometers

ODW-621. RS-232 Point-to-point applications

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

Model KT 115 Cooling incubators with thermoelectric cooling

TELEDYNE HASTINGS INSTRUMENTS

Magnecraft Power Relays

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

ADJUSTABLE SPEED DRIVES. nc1 Drive

Inverters Selection Guide

Stud Welding Equipment

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Label Applicator HERMA 400

SITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.

LD OEM/LD PDS/LD PeCo

Intelligent compressor solutions. EFC, EFCe Systems Electronic Frequency Control EFC. EFCe

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

MX1609. Data Sheet. Thermocouple amplifier. Special features. Block diagram. B en

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LONWORKS Fibre Optic Converter

LED control gear Compact fixed output. Uconverter LCI 55 W 1400 ma O010 TOP series Ø4,4. Ordering data

Transcription:

Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Rexroth IndraDrive Fc Compact, high-performance standard frequency converters Simply a better drive

2 Rexroth IndraDrive Fc Simply a better drive Rexroth IndraDrive Fc is the new, high-performance range of converters for open-loop applications. Housed in an ultra-compact book-sized format, four standard frequency converters cover the entire drive range from 0.25 kw to 7.5 kw. IndraDrive Fc is setting new standards in its class with its extensive functions including simple installation, start-up and operation. Easy installation The well thought-out design provides user-friendly installation and adjacent positioning of several units. Plug-in control terminals facilitate and speed up installation. Quick and easy start-up Simple start-up without the need for a PC is possible due to the intelligent automatic motor identification functionality of the drive. Using a PC and Rexroth s start-up software, DriveTop Fc, the drive parameters can be set, documented and saved either offline or via the RS232 interface. If using the RS485 connection, simultaneous communication with up to 31 IndraDrive Fcs is possible. The integrated oscilloscope function assists with optimization of the drive. Communication on all levels IndraDrive Fc uses modular function modules to communicate at all automation levels. We supply two plug-in modules for operation without a PC: Standard operating module for parameter-oriented operation Deluxe operating module with text display in six languages for document-free start-up The fieldbus interfaces available are PROFIBUS, CANopen and Device- Net. IndraDrive Fc is the range of compact standard frequency converters from the Rexroth modular system powerful units featuring a number of additional functions. This unique modular system developed by Rexroth combines all the components required for successful automation concepts from drive and control systems right through to a high-performance framework for standardized engineering and user-friendly operation. This innovation brings you all the latitude associated with modern automation technology consistency, intelligence and forward compatibility.

3 Maximum plant availability IndraDrive Fc integrates extensive monitoring functions and an EMC filter. Safe and reliable operation is assured by monitoring sensors controlling the input voltage, output current and motor temperature. Motor operation is safe every time thanks to the integrated brake management function. Characteristics and functions Power supply voltages from 200 V to 480 V Output frequency from 0 Hz to 400 Hz Overload capacity: 200 % for 5 s and 150 % for 60 s Continuously adjustable pulse frequency from 3 khz to 16 khz Operating modes: - Linear V/f curve - Sensorless vector control Functions: - automatic motor parameter identification - 4 parameter sets, switchable online - PID controller and process controller - 31 fixed frequencies - 2 notch frequencies - Motor potentiometer function - Limit switch evaluation - Flying restart - Programmable dynamic braking - S-ramp function - and much more Interfaces: - RS232 (Single Slave) - RS485 (USS) - 5 digital inputs (< 1 ms response time) - 2 analog inputs, can also be used as digital inputs - 1 analog output - 2 multi-function relays 230 V AC/30 V DC, 2 A Integrated brake chopper Integrated brake control Internal EMC network filter for limit curve A according to EN 55011 Cooling system - Natural convection (size A, 230 V) - Fan-cooled, temperaturecontrolled (sizes A, B, C, D)

4 Rexroth IndraDrive Fc system overview Standard frequency converter Function modules and accessories Rated motor 1/3 x AC 3 x AC Power 230 V 400 V Standard operating panel 4 x 7 segment display 1 parameter set, storable 0.25 kw 0.37 kw Comfort operating panel Graphics-based display 5 parameter sets, storable Interactive start-up Choice of 6 languages 0.55 kw PROFIBUS 1.5 MBaud 0.75 kw 1.1 kw 1.5 kw 2.2 kw 3.0 kw Consistent in all converers PROFIBUS 12 MBaud External 24 V suitable for connection* CANopen Profile DS402 External 24 V suitable for connection* DeviceNet External 24 V suitable for connection* * For detection of bus node when converter is turned off 4.0 kw 5.5 kw 7.5 kw Product CD: DriveTop Fc PDF manuals Accessories: PC cable Brake resistors

5 Small size big performance Size A W x H x D: 76 x 186 x 151 mm L1: 220 mm Size B W x H x D: 76 x 226 x 151 mm L1: 260 mm Size C W x H x D: 98 x 241 x 178 mm L1: 275 mm Size D W x H x D: 98 x 286 x 178 mm L1: 320 mm L1 L1 = Installation dimension

6 Technical data with the power to convince Type FCS01.1E-W FCS01.1E-W 0003-A-02-0005-A-02-0006-A-02-0008-A-02-0011-A-02-0015-A-02-0019-A-02-0003-A-04-0005-A-04-0006-A-04-0008-A-04-0011-A-04-0015-A-04-0019-A-04-0025-A-04-0032-A-04- Power data Mains input voltage V 1 AC 200 240 V 3 AC 200... 240 V (± 10 %) 47... 63 Hz 3 AC 380 480 V (± 10 %/± 20 %) 47... 63 Hz Rated motor power kw 0.25 0.37 0.55 0.75 1.1 1.5 2.2 0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5 Continuous current A 1.7 2.2 3 4 5.5 7 9 1.7 2.3 3.1 4.0 5.5 7.5 9.5 12.5 16.0 Maximum current A 3.4 4.4 6 8 11 14 18 3.4 4.6 6.2 8 11 15 19 25 32 Continuous input mains current 1 AC 230 V Continuous input mains current 3 AC 230 V Continuous input mains current 3 AC 400 V Reference between output and mains voltage A 3.7 4.8 6.5 8.7 12 15.2 19.6 A 2.4 3.1 4.2 5.6 7.7 9.8 13.3 A 2.4 3.2 4.3 5.6 7.7 10.5 13.3 17.5 22.4 if U LN < 230 V: 2 % power reduction per 5 V if U LN > 230 V: no power gain if U LN < 400 V: 1 % power reduction per 4 V if U LN > 400 V: no power gain DC bus connection 1) DC bus capacity F 300 300 600 600 900 1200 1500 120 120 175 210 305 420 500 630 920 Output voltage V 0 power supply voltage Brake resistor 2) Brake resistor Continuous braking power kw 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.4 0.4 0.6 0.6 Maximum braking power kw 0.7 0.7 0.7 0.7 2.2 2.2 2.2 1.3 1.3 1.3 2.6 2.6 5.2 5.2 8.6 8.6 Control voltage data Control voltage Mechanical data Size A B A B C D Width mm 76 76 98 Height mm 186 226 186 226 241 286 Depth mm 151 151 178 Installation dimensions L1 mm 220 260 220 260 275 320 Weight kg 1.4 1.8 1.4 1.8 2.7 3.1 All data apply to rated operation from 4 Hz rotational frequency. Derating from 6 khz switching frequency 1) For DC coupling of several frequency converters 2) Brake resistors available soon The maximum braking power of the brake resistors is based on a rated DC link voltage of 400 V at FCS01.1E-Wxxxx-A-02 and 720 V at FCS01.1E-Wxxxx-A-04 external internal

7 FCS01 1/3 AC 200... 240 V for FCS01.1E-Wxxxx-A-02-3 AC 380... 480 V for FCS01.1E-Wxxxx-A-04- Mains connector 3~ X3 Mains connection L1 L2 L3 PE X43 Function modules: Operating panel, fieldbus X31 Relay output External braking resistor X5 + B B Brake chopper X35 Analog inputs/outputs X36 Digital inputs and voltage supply Internal power supply X2 RS232, RS485 DC bus connection + B DC X5 + B DC 3~ MotTemp (PTC) Relay for brake U V W PE Motor connection X5 X36 X31 M 3~

8 Standard and geared motors for your application We recommend using IndraDrive Fc in conjunction with geared motors or three-phase asynchronous motors made by NORD Drive Systems or VEM Motors. On request, we can supply all-inone solutions, comprising frequency converter and motors, also sourced directly from Rexroth. The range of geared motors covers various types of gears with different performance categories: Spur gear motors Offset-shaft geared motors Bevel gear motors Worm gear motors The range of three-phase asynchronous motors includes: Standard motors High-efficiency motors These motors are particularly suitable for operation with frequency converters and boast the following features: Motor design conforming to DIN EN 60034 (IEC 72) Mounting dimensions and output correlation compliant with DIN 42673, 42677 Robust, low-vibration design in gray cast iron Protection category IP 55, higher protection category up to IP 65 optional Insulation class F with thermal reserve, insulation class H optional Additional options: brakes, encoder, position of terminal box, etc.

9 Standard frequency converter for the full range of operating modes 1.1 x I N 1.5 x I N 1.0 x I N 1.0 x I N 1.0 x I N 2 x I N 1.0 x I N t Mechanical motor output P N U I N motor Continuous duty 1.0 x I N (> 10 min) Overload duty 1.1 x I N (1 min) 1.0 x I N (9 min) Overload duty 1.5 x I N (1 min) 1.0 x I N (4 min) Overload duty 2.0 x I N (2 s) 1.0 x I N (18 s) 0.25 kw 230 V 1.4 A FCS01.1E-W0003-A-02- FCS01.1E-W0003-A-02- FCS01.1E-W0003-A-02- FCS01.1E-W0003-A-02-0.37 kw 230 V 1.9 A FCS01.1E-W0005-A-02- FCS01.1E-W0005-A-02- FCS01.1E-W0005-A-02- FCS01.1E-W0005-A-02-0.55 kw 0.75 kw 1.1 kw 1.5 kw 2.2 kw 230 V 2.8 A FCS01.1E-W0006-A-02- FCS01.1E-W0006-A-02- FCS01.1E-W0008-A-02- FCS01.1E-W0008-A-02-400 V 1.6 A FCS01.1E-W0003-A-04- FCS01.1E-W0003-A-04- FCS01.1E-W0005-A-04- FCS01.1E-W0005-A-04-230 V 3.7 A FCS01.1E-W0008-A-02- FCS01.1E-W0008-A-02- FCS01.1E-W0011-A-02- FCS01.1E-W0011-A-02-400 V 2.1 A FCS01.1E-W0005-A-04- FCS01.1E-W0005-A-04- FCS01.1E-W0005-A-04- FCS01.1E-W0005-A-04-230 V 4.6 A FCS01.1E-W0011-A-02- FCS01.1E-W0011-A-02- FCS01.1E-W0011-A-02- FCS01.1E-W0011-A-02-400 V 2.6 A FCS01.1E-W0006-A-04- FCS01.1E-W0006-A-04- FCS01.1E-W0006-A-04- FCS01.1E-W0006-A-04-230 V 5.9 A FCS01.1E-W0015-A-02- FCS01.1E-W0015 -A-02- FCS01.1E-W0015-A-02- FCS01.1E-W0015-A-02-400 V 3.4 A FCS01.1E-W0008-A-04- FCS01.1E-W0008-A-04- FCS01.1E-W0008-A-04- FCS01.1E-W0008-A-04-230 V 8.6 A FCS01.1E-W0019-A-02- FCS01.1E-W0019-A-02-400 V 5.0 A FCS01.1E-W0011-A-04- FCS01.1E-W0011-A-04- FCS01.1E-W0011-A-04- FCS01.1E-W0011-A-04-3.0 kw 400 V 6.7 A FCS01.1E-W0015-A-04- FCS01.1E-W0015-A-04- FCS01.1E-W0015-A-04- FCS01.1E-W0015-A-04-4.0 kw 400 V 8.8 A FC S01.1E-W0019-A-04- FCS01.1E-W0019-A-04- FCS01.1E-W0025-A-04- FCS01.1E-W0025-A-04-5.5 kw 400 V 11.8 A FCS01.1E-W0025-A-04- FCS01.1E-W0025-A-04- FCS01.1E-W0032-A-04- FCS01.1E-W0032-A-04-7.5 kw 400 V 15 A FCS01.1E-W0032-A-04- FCS01.1E-W0032-A-04- The examples selected are based on the operation of 4-pin standard motors for 3 AC 230 V/400 V, 50 Hz at a switching frequency of up to 6 khz and a rotational frequency > 4 Hz.

10 Rexroth IndraDrive Fc the power to convince in all applications Automation Printing and converting machines Conveying and storage systems Glass processing machines Handling and assembly systems Woodworking machines Plastics processing machines Food processing and packaging machines Textile machines Metal forming Machine tools and much more

11 Rexroth IndraDrive Fc Order quote form Copy, complete and fax. See next page for adresses. Company Name City, State Phone E-mail Department Street Zip/Postal Code Fax Quantity Frequency converter 230 V Part number FCS01.1E-W0003-A-02- R911311054 0.25 kw/1/3 x 200 240 V, 50/60 Hz, 1.7/3.4 A FCS01.1E-W0005-A-02- R911311055 0.37 kw/1/3 x 200 240 V, 50/60 Hz, 2.2/4.4 A FCS01.1E-W0006-A-02- R911311056 0.55 kw/1/3 x 200 240 V, 50/60 Hz, 3/6 A FCS01.1E-W0008-A-02- R911311057 0.75 kw/1/3 x 200 240 V, 50/60 Hz, 4/8 A FCS01.1E-W0011-A-02- R911311058 1.1 kw/1/3 x 200 240 V, 50/60 Hz, 5,5/11 A FCS01.1E-W0015-A-02- R911311059 1.5 kw/1/3 x 200 240 V, 50/60 Hz, 7/14 A FCS01.1E-W0019-A-02- R911311060 2.2 kw/1/3 x 200 240 V, 50/60 Hz, 9.5/19 A Frequency converter 400 V FCS01.1E-W0003-A-04- R911311061 0.55 kw/3 x 380 480 V, 50/60 Hz, 1.7/3.4 A FCS01.1E-W0005-A-04- R911311062 0.75 kw/3 x 380 480 V, 50/60 Hz, 2.3/4.6 A FCS01.1E-W0006-A-04- R911311063 1.1 kw/3 x 380 480 V, 50/60 Hz, 3.1/6.2 A FCS01.1E-W0008-A-04- R911311064 1.5 kw/3 x 380 480 V, 50/60 Hz, 4/8 A FCS01.1E-W0011-A-04- R911311065 2.2 kw/3 x 380 480 V, 50/60 Hz, 5.5/11 A FCS01.1E-W0015-A-04- R911311066 3 kw/3 x 380 480 V, 50/60 Hz, 7.5/15 A FCS01.1E-W0019-A-04- R911311067 4 kw/3 x 380 480 V, 50/60 Hz, 9.5/19 A FCS01.1E-W0025-A-04- R911311068 5.5 kw/3 x 380 480 V, 50/60 Hz, 12.5/25 A FCS01.1E-W0032-A-04- R911311069 7.5 kw/3 x 380 480 V, 50/60 Hz, 16/32 A Function modules FCC01.1T-STD-NNNN R911311070 Standard operating panel: 4 x 7 segment, parameter set FCC01.1T-CMF-NNNN R911311071 Comfort operating panel: graphic-based display, 5 parameter set FCC01.1F-PB1-NNNN R911311072 Fieldbus module: PROFIBUS FCC01.1F-PB2-NNNN R911311073 Fieldbus module: PROFIBUS 12 MBaud (ext. 24 V) FCC01.1F-CN1-NNNN R911311074 Fieldbus module: CANopen (ext. 24 V) FCC01.1F-DN1-NNNN R911311075 Fieldbus module: DeviceNet (ext. 24 V) Accessories RKB0005 R91131896 PC cable IndraDrive Fc, RS232, 3 m SWA-DTOPFC-INB-01VRS-DO-CD650-COPY R911311774 Product CD (includes DriveTop Fc, PDF manuals etc.) DOK-INDRV*-FCS01******-IB01-DE-P R911310845 Manual German, printed version DOK-INDRV*-FCS01******-IB01-EN-P R911310782 Manual English, printed version

Bosch Rexroth AG Electric Drives and Controls P.O. Box 13 57 97803 Lohr, Germany Bgm.-Dr.-Nebel-Str. 2 97816 Lohr, Germany Phone +49 9352 40-0 Fax +49 9352 40-4885 www.boschrexroth.com Presented by 71 512 AE/05-09 A1 HW Bosch Rexroth AG 2005 Subject to revisions! Printed in Germany