Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

Similar documents
Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

Product Catalog Electric Drives and Controls. Frequency Converters IndraDrive Fc

Product Catalog Electric Drives and Controls. Frequency converter IndraDrive Fc

Electric Drives and Controls Product Catalog. Frequency converter IndraDrive Fc

Frequency Converter Fv

Frequency Converter EFC 3610, EFC 5610

Frequency Converter EFC 3610, EFC 5610

Product Catalog Frequency Converters

Frequency Converter EFC 3610, EFC 5610

Basic, cost-effective motor control in one unit: MOVITRAC 07.

AF-300 E11 Adjustable Frequency Drive

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

Operating temperatures from 20 C ( 4 F) up to 50 C (122 F). Up to 70 C (158 F) with current derating and optional control module fan kit.

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Variable speed drives Altivar 38 Mastering elements for more comfort

REO vibratory conveyor technology Solutions for your vibratory conveyors

BOSTON GEAR CONTROLLERS. ACE 10 Series 1/4 through 3 HP Adjustable Frequency AC Motor Controllers MEX (55) QRO (442)

For applications from 0.25 to 5 HP, the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted.

MICROMASTER Encoder Module

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

Generator protection relay

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

2000 W, 2450 MHz Microwave Generator GMP 20K SM 56M230 FST 3 IR

Rexroth GDS/GDM1.1 Digital Singleturn/Multiturn Encoder

CNC. IndraMotion MTX micro Up to 12 axes

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

EMC Solutions Noise filtering

VAT 20 Adjustable Frequency Drive

Siemens Industry Online Support

Bulletin 150, 154 Softstarters Quick Selection Table

Fibre Optic Modem ODW-611

POSIWIRE. WS61 with internal magnetic encoder Position Sensor. Cable Extension Position Sensors. Datasheet

OPTOTRONIC Intelligent

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

Electric Rotary Modules. Rotary Actuators

Product Information. EIB 700 Series External Interface Box

Flexible. Fast. Precise. PPU-E Pick & Place Unit

Set for simple I/O communication via PROFIBUS-DP in IP20 TI-BL20-DPV1-S-8

Absolute Encoders Multiturn

CML 700i Measuring light curtain with integrated control unit and interfaces for even simpler operation

Model KT 53 Cooling incubators with thermoelectric cooling

Selection guide siemens.com/sirius-modular-system

ROTARY ENCODER SELECTION. A Step by Step Guide

LASER. Laser-Position-Transducer. LLD Series. Key-Features:

english SGC inverter series hf transformer input voltage up to 800 V touch screen built-in data loggers

IMPAC Infrared Thermometers

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

System Interface Unit SIU-100/100T

Process transmitter RMA422

LASER. Laser-Position-Transducer. LLD-150 Series. Key-Features:

PRINCIPLES AND APPLICATIONS

Presentation 2 for asynchronous motors 2

Direct PWM. 1000/2000 Series POWERBLOK MODULE

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

Intelligent compressor solutions. EFC, EFCe Systems Electronic Frequency Control EFC. EFCe

Process Transmitter RMA 422

Digital 4 Q - Servo amplifier for brushless DC Servo motors (Trapeze)

ADJUSTABLE SPEED DRIVES. nc1 Drive

GRUNDFOS alldos product information. The solution for complex dosing tasks

Model KT 115 Cooling incubators with thermoelectric cooling

istep STEPPER MOTOR PUMP

LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56

Operating temperatures from 20 C ( 4 F) up to 50 C (122 F). Up to 70 C (158 F) with current derating and optional control module fan kit

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

IS 140 IGA 140 IS 140-PB IGA 140-PB IS 140-PN IGA 140-PN IS 140-ET IGA 140-ET

BL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC

ODW-621. RS-232 Point-to-point applications

EAM PROFIBUS MULTITURN ABSOLUTE ENCODER PRESENTATION HARDWARE INSTALLATION DEVICE MULTITURN ABSOLUTE ENCODERS EAM PROFIBUS

SITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.

Absolute encoders multiturn

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

HiPace 300 with TC 110 and power supply OPS 100, DN 100 ISO-F

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

Lt DELTA USA, Inc

DRS61: Incremental encoders, number of lines and zero pulse width freely programmable DRS60: Incremental Encoders with Zero-Pulse-Teach

Magnecraft Power Relays

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Flow Measurement SITRANS F M

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

TELEDYNE HASTINGS INSTRUMENTS

Label Applicator HERMA 400

LED control gear Compact fixed output. Uconverter LCI 55 W 1400 ma O010 TOP series Ø4,4. Ordering data

Inverters Selection Guide

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

Roof-mounted Blue e+ cooling unit Integration solution VX25

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

istep STEPPER MOTOR PUMP

Sensor technologies Proximity sensors Series ST4. Brochure

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

MX1609. Data Sheet. Thermocouple amplifier. Special features. Block diagram. B en

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

SRV02-Series. Ball & Beam. User Manual

KRF EMC Filters Installation, Operation and Maintenance Manual

SOFT STARTER. We are delivering Real Cost Benefits CD AUTOMATION POWERED BY INNOVATION. Soft Starter Catalog 2018 Release n.

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

Transcription:

Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Rexroth IndraDrive Fc Compact, high-performance standard frequency converters Simply a better drive

2 Rexroth IndraDrive Fc Simply a better drive Rexroth IndraDrive Fc is the new, high-performance range of converters for open-loop applications. Housed in an ultra-compact book-sized format, four standard frequency converters cover the entire drive range from 0.25 kw to 7.5 kw. IndraDrive Fc is setting new standards in its class with its extensive functions including simple installation, start-up and operation. Easy installation The well thought-out design provides user-friendly installation and adjacent positioning of several units. Plug-in control terminals facilitate and speed up installation. Quick and easy start-up Simple start-up without the need for a PC is possible due to the intelligent automatic motor identification functionality of the drive. Using a PC and Rexroth s start-up software, DriveTop Fc, the drive parameters can be set, documented and saved either offline or via the RS232 interface. If using the RS485 connection, simultaneous communication with up to 31 IndraDrive Fcs is possible. The integrated oscilloscope function assists with optimization of the drive. Communication on all levels IndraDrive Fc uses modular function modules to communicate at all automation levels. We supply two plug-in modules for operation without a PC: Standard operating module for parameter-oriented operation Deluxe operating module with text display in six languages for document-free start-up The fieldbus interfaces available are PROFIBUS DP, CANopen and DeviceNet. IndraDrive Fc is a family of compact standard frequency converters. These high-performance units, which are part of Rexroth s Automation House, offer a number of additional functions. Our unique Automation House gives you everything you need to develop your automation applications including drives, controllers, a powerful engineering framework and user-friendly operation. This innovative range of products is based on many years of applications experience, and it gives you access to the entire world of freedom offered by today s state-of-theart automation systems.

3 Maximum plant availability IndraDrive Fc integrates extensive monitoring functions and an EMC filter. Safe and reliable operation is assured by monitoring sensors controlling the input voltage, output current and motor temperature. Motor operation is safe every time thanks to the integrated brake management function. Characteristics and functions Power supply voltages from 200 V to 480 V Output frequency from 0 Hz to 400 Hz Overload capacity: 200 % for 5 s and 150 % for 60 s Continuously adjustable pulse frequency from 3 khz to 16 khz Operating modes: - Linear V/f curve - Sensorless vector control Functions: - automatic motor parameter identification - 4 parameter sets, switchable online - PID controller and process controller - 31 fixed frequencies - 2 notch frequencies - Motor potentiometer function - Fast stop - Flying restart - Programmable dynamic braking - Acceleration ramp - and much more Interfaces: - RS232 (Single Slave) - RS485 (USS) - 5 digital inputs (< 1 ms response time) - 2 analog inputs, can also be used as digital inputs - 1 analog output - 2 multi-function relays 230 V AC/30 V DC, 2 A Integrated brake chopper Integrated brake control Internal EMC network filter for limit curve A according to EN 55011 Cooling system - Passive cooling depending on power range - Fan-cooled, temperaturecontrolled

4 Rexroth IndraDrive Fc system overview Standard frequency converter Function modules and accessories Rated motor 1/3 x AC 3 x AC Power 230 V 400 V Standard operating panel 4 x 7 segment display 1 parameter set, storable 0.25 kw 0.37 kw Comfort operating panel Graphics-based display 5 parameter sets, storable Interactive start-up Choice of 6 languages 0.55 kw PROFIBUS DP 1.5 MBaud 0.75 kw 1.1 kw 1.5 kw 2.2 kw 3.0 kw Consistent in all converers PROFIBUS DP 12 MBaud External 24 V suitable for connection* CANopen Profi le DS402 External 24 V suitable for connection* DeviceNet External 24 V suitable for connection* * For detection of bus node when converter is turned off 4.0 kw 5.5 kw 7.5 kw Product CD: DriveTop Fc PDF manuals Accessories: PC cable EMC kit Brake resistors

5 Small size big performance Size A W x H x D: 76 x 186 x 151 mm L1: 220 mm Size B W x H x D: 76 x 226 x 151 mm L1: 260 mm Size C W x H x D: 98 x 241 x 178 mm L1: 275 mm Size D W x H x D: 98 x 286 x 178 mm L1: 320 mm L1 L1 = Installation dimension

6 Technical data with the power to convince Type FCS01.1E-W FCS01.1E-W 0003-A-02-0005-A-02-0006-A-02-0008-A-02-0011-A-02-0015-A-02-0019-A-02-0003-A-04-0005-A-04-0006-A-04-0008-A-04-0011-A-04-0015-A-04-0019-A-04-0025-A-04-0032-A-04- Power data Mains input voltage V 1 AC 200 240 V 3 AC 200... 240 V (± 10 %) 47... 63 Hz 3 AC 380 480 V (± 10 %/± 20 %) 47... 63 Hz Rated motor power kw 0.25 0.37 0.55 0.75 1.1 1.5 2.2 0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5 Continuous current A 1.7 2.2 3 4 5.5 7 9 1.7 2.3 3.1 4.0 5.5 7.5 9.5 12.5 16.0 Maximum current A 3.4 4.4 6 8 11 14 18 3.4 4.6 6.2 8 11 15 19 25 32 Continuous input mains current 1 AC 230 V A 3.7 4.8 6.5 8.7 12 15.2 19.6 Continuous input mains current 3 AC 230 V A 2.4 3.1 4.2 5.6 7.7 9.8 13.3 Continuous input mains current 3 AC 400 V A 2.4 3.2 4.3 5.6 7.7 10.5 13.3 17.5 22.4 Reference between output and mains voltage if U LN < 230 V: 2 % power reduction per 5 V if U LN > 230 V: no power gain if U LN < 400 V: 1 % power reduction per 4 V if U LN > 400 V: no power gain DC bus connection 1) DC bus capacity mf 300 300 600 600 900 1200 1500 120 120 175 210 305 420 500 630 920 Output voltage V 0 power supply voltage Brake resistor Brake resistor external Continuous braking power kw 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.4 0.4 0.6 0.6 Maximum braking power kw 0.7 0.7 0.7 0.7 2.2 2.2 2.2 1.3 1.3 1.3 2.6 2.6 5.2 5.2 8.6 8.6 Control voltage data Control voltage internal Mechanical data Size A B A B C D Width mm 76 76 98 Height mm 186 226 186 226 241 286 Depth mm 151 151 178 Installation dimensions L1 mm 220 260 220 260 275 320 Weight kg 1.4 1.8 1.4 1.8 2.7 3.1 All data apply to rated operation from 4 Hz rotational frequency. Derating from 6 khz switching frequency 1) For DC coupling of several frequency converters The maximum braking power of the brake resistors is based on a rated DC link voltage of 400 V at FCS01.1E-Wxxxx-A-02 and 720 V at FCS01.1E-Wxxxx-A-04

7 FCS01 1/3 AC 200... 240 V for FCS01.1E-Wxxxx-A-02-3 AC 380... 480 V for FCS01.1E-Wxxxx-A-04- Mains connector X3 Mains connection L1 L2 L3 PE X43 Function modules: Operating panel, field bus 3~ X31 Relay output External braking resistor X5 + B B Brake chopper X35 Analog inputs/outputs X36 Digital inputs and voltage supply Internal power supply X2 RS232, RS485 DC link capacity + B DC X5 + B DC 3~ MotTemp (PTC) Relay for brake U V W PE Motor connection X5 X36 X31 M 3~

8 Standard and geared motors for your application We recommend using IndraDrive Fc in conjunction with geared motors or three-phase asynchronous motors made by NORD Drive Systems or VEM Motors. On request, we can supply all-inone solutions, comprising frequency converter and motors, also sourced directly from Rexroth. The range of geared motors covers various types of gears with different performance categories: Spur gear motors Offset-shaft geared motors Bevel gear motors Worm gear motors The range of three-phase asynchronous motors includes: Standard motors High-efficiency motors These motors are particularly suitable for operation with frequency converters and boast the following features: Motor design conforming to DIN EN 60034 (IEC 72) Mounting dimensions and output correlation compliant with DIN 42673, 42677 Robust, low-vibration design in gray cast iron Protection category IP55, higher protection category up to IP65 optional Insulation class F with thermal reserve, insulation class H optional Additional options: brakes, encoder, position of terminal box, etc.

9 Standard frequency converter for the full range of operating modes 1,1 x I N 1,5 x I N 1,0 x I N 1,0 x I N 1,0 x I N 2 x I N 1,0 x I N t Mechanical motor output P N U I N motor Continuous duty 1.0 x I N (> 10 min) Overload duty 1.1 x I N (1 min) 1.0 x I N (9 min) Overload duty 1.5 x I N (1 min) 1.0 x I N (4 min) Overload duty 2.0 x I N (2 s) 1.0 x I N (18 s) 0.25 kw 230 V 1.4 A FCS01.1E-W0003-A-02- FCS01.1E-W0003-A-02- FCS01.1E-W0003-A-02- FCS01.1E-W0003-A-02-0.37 kw 230 V 1.9 A FCS01.1E-W0005-A-02- FCS01.1E-W0005-A-02- FCS01.1E-W0005-A-02- FCS01.1E-W0005-A-02-0.55 kw 230 V 2.8 A FCS01.1E-W0006-A-02- FCS01.1E-W0006-A-02- FCS01.1E-W0008-A-02- FCS01.1E-W0008-A-02-400 V 1.6 A FCS01.1E-W0003-A-04- FCS01.1E-W0003-A-04- FCS01.1E-W0005-A-04- FCS01.1E-W0005-A-04-0.75 kw 230 V 3.7 A FCS01.1E-W0008-A-02- FCS01.1E-W0008-A-02- FCS01.1E-W0011-A-02- FCS01.1E-W0011-A-02-400 V 2.1 A FCS01.1E-W0005-A-04- FCS01.1E-W0005-A-04- FCS01.1E-W0005-A-04- FCS01.1E-W0005-A-04-1.1 kw 230 V 4.6 A FCS01.1E-W0011-A-02- FCS01.1E-W0011-A-02- FCS01.1E-W0011-A-02- FCS01.1E-W0011-A-02-400 V 2.6 A FCS01.1E-W0006-A-04- FCS01.1E-W0006-A-04- FCS01.1E-W0006-A-04- FCS01.1E-W0006-A-04-1.5 kw 230 V 5.9 A FCS01.1E-W0015-A-02- FCS01.1E-W0015 -A-02- FCS01.1E-W0015-A-02- FCS01.1E-W0015-A-02-400 V 3.4 A FCS01.1E-W0008-A-04- FCS01.1E-W0008-A-04- FCS01.1E-W0008-A-04- FCS01.1E-W0008-A-04-2.2 kw 230 V 8.6 A FCS01.1E-W0019-A-02- FCS01.1E-W0019-A-02-400 V 5.0 A FCS01.1E-W0011-A-04- FCS01.1E-W0011-A-04- FCS01.1E-W0011-A-04- FCS01.1E-W0011-A-04-3.0 kw 400 V 6.7 A FCS01.1E-W0015-A-04- FCS01.1E-W0015-A-04- FCS01.1E-W0015-A-04- FCS01.1E-W0015-A-04-4.0 kw 400 V 8.8 A FCS01.1E-W0019-A-04- FCS01.1E-W0019-A-04- FCS01.1E-W0025-A-04- FCS01.1E-W0025-A-04-5.5 kw 400 V 11.8 A FCS01.1E-W0025-A-04- FCS01.1E-W0025-A-04- FCS01.1E-W0032-A-04- FCS01.1E-W0032-A-04-7.5 kw 400 V 15 A FCS01.1E-W0032-A-04- FCS01.1E-W0032-A-04- The examples selected are based on the operation of 4-pin standard motors for 3 AC 230 V/400 V, 50 Hz at a switching frequency of up to 6 khz and a rotational frequency > 4 Hz.

10 Rexroth IndraDrive Fc the power to convince in all applications Automation Printing and converting machines Conveying and storage systems Glass processing machines Handling and assembly systems Woodworking machines Plastics processing machines Food processing and packaging machines Textile machines Metal forming Machine tools and much more

11 Company Department Rexroth IndraDrive Fc Order quote form Name City, State Phone E-mail Street Zip/Postal Code Fax Quantity Frequency converter 230 V Part number FCS01.1E-W0003-A-02- R911311054 0.25 kw/1/3 x 200 240 V, 50/60 Hz, 1.7/3.4 A FCS01.1E-W0005-A-02- R911311055 0.37 kw/1/3 x 200 240 V, 50/60 Hz, 2.2/4.4 A FCS01.1E-W0006-A-02- R911311056 0.55 kw/1/3 x 200 240 V, 50/60 Hz, 3/6 A FCS01.1E-W0008-A-02- R911311057 0.75 kw/1/3 x 200 240 V, 50/60 Hz, 4/8 A FCS01.1E-W0011-A-02- R911311058 1.1 kw/1/3 x 200 240 V, 50/60 Hz, 5.5/11 A FCS01.1E-W0015-A-02- R911311059 1.5 kw/1/3 x 200 240 V, 50/60 Hz, 7/14 A FCS01.1E-W0019-A-02- R911311060 2.2 kw/1/3 x 200 240 V, 50/60 Hz, 9.5/19 A Frequency converter 400 V FCS01.1E-W0003-A-04- R911311061 0.55 kw/3 x 380 480 V, 50/60 Hz, 1.7/3.4 A FCS01.1E-W0005-A-04- R911311062 0.75 kw/3 x 380 480 V, 50/60 Hz, 2.3/4.6 A FCS01.1E-W0006-A-04- R911311063 1.1 kw/3 x 380 480 V, 50/60 Hz, 3.1/6.2 A FCS01.1E-W0008-A-04- R911311064 1.5 kw/3 x 380 480 V, 50/60 Hz, 4/8 A FCS01.1E-W0011-A-04- R911311065 2.2 kw/3 x 380 480 V, 50/60 Hz, 5.5/11 A FCS01.1E-W0015-A-04- R911311066 3 kw/3 x 380 480 V, 50/60 Hz, 7.5/15 A FCS01.1E-W0019-A-04- R911311067 4 kw/3 x 380 480 V, 50/60 Hz, 9.5/19 A FCS01.1E-W0025-A-04- R911311068 5.5 kw/3 x 380 480 V, 50/60 Hz, 12.5/25 A FCS01.1E-W0032-A-04- R911311069 7.5 kw/3 x 380 480 V, 50/60 Hz, 16/32 A Function modules FCC01.1T-STD-NNNN R911311070 Standard operating panel: 4 x 7 segment, parameter set FCC01.1T-CMF-NNNN R911311071 Comfort operating panel: graphic-based, 5 parameter set FCC01.1F-PB1-NNNN R911311072 Fieldbus module: PROFIBUS DP FCC01.1F-PB2-NNNN R911311073 Fieldbus module: PROFIBUS DP 12 MBaud (ext. 24 V) FCC01.1F-CN1-NNNN R911311074 Fieldbus module: CANopen (ext. 24 V) FCC01.1F-DN1-NNNN R911311075 Fieldbus module: DeviceNet (ext. 24 V) Accessories RKB0005 R911311896 PC cable IndraDrive Fc, RS232, 3 m SWA-DTOPFC-INB-01VRS-DO-CD650-COPY R911311774 Product CD (includes DriveTop Fc, PDF manuals etc.) DOK-INDRV*-FCS01******-IB01-DE-P R911310782 Operating manual German, printed version DOK-INDRV*-FCS01******-IB01-EN-P R911310845 Operating manual English, printed version FAS02.1-001-EMC-NN R911315469 EMC Kit for sizes A and B FAS02.1-002-EMC-NN R911315470 EMC Kit for sizes C and D FAS01.1-001-TMP-NN R911315466 Temperature switch for breaking resistor, based-mounted version FLR01.1U FLR01.1U-0100-N240R-A-004-NNNN R911315459 Breaking resistor, based-mounted version for FCS 0.25 and 0.37 kw, 1/3 x 200...240 V FLR01.1U-0100-N150R-A-004-NNNN R911315460 Breaking resistor, based-mounted version for FCS 0.55 and 0.75 kw, 1/3 x 200...240 V FLR01.1U-0200-N75R0-A-004-NNNN R911315461 Breaking resistor, based-mounted version for FCS 1.1 2.2 kw, 1/3 x 200...240 V FLR01.1U-0100-N400R-A-007-NNNN R911315462 Breaking resistor, based-mounted version for FCS 0.55 and 0.75 kw, 3 x 380...480 V FLR01.1U-0200-N220R-A-007-NNNN R911315463 Breaking resistor, based-mounted version for FCS 1.1 2.2 kw, 3 x 380...480 V FLR01.1N-0400-N100R-A-007-NNNN R911315464 Breaking resistor, for separate mounting FCS 3,0 and 4.0 kw, 3 x 380...480 V FLR01.1N-0600-N60R0-A-007-NNNN R911315465 Breaking resistor, for separate mounting FCS 5.5 and 7.5 kw, 3 x 380...480 V Copy, complete and fax. See next page for adresses

Bosch Rexroth AG Electric Drives and Controls P.O. Box 13 57 97803 Lohr, Germany Bgm.-Dr.-Nebel-Str. 2 97816 Lohr, Germany Phone +49 9352 40-0 Fax +49 9352 40-4885 www.boschrexroth.com Presented by The data specifi ed above only serve to describe the product. As our products are constantly being further developed, no statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verifi cation. It must be remembered that our products are subject to a natural process of wear and aging. 71 512 AE/2007-12 A3 HW R911313052 Bosch Rexroth AG 2007 Subject to revisions! Printed in Germany