Liquid Chromatography- Mass Spectrometer Manual

Similar documents
Vasudevan Agilent 1100 Series HPLC w/ DAD & FLD Detector (nonbuffer

HPLC Tips and Tricks. Tiziana Ladisa Sales Support Specialist for Chromatography Italy Thermo Fisher Scientific, Rodano (MI)

STANDARD OPERATING PROCEDURE:

Customer Responsibilities. Important Customer Information Infinity LC/1260 Infinity LC Site Preparation Checklist

Achieving More Efficient Data Review with OpenLAB CDS

ChromQuest 5.0 Chromatography Data System

Customer Responsibilities. Important Customer Information. Agilent InfinityLab LC Series Site Preparation Checklist

Waters GCT GCMS Training Manual (Nominal Mass GCMS version) 02/06/2012 S.V.

Introduction to System Suitability Tests Michael Wright Bioanalytical Services LGC Fordham, UK

TMT data acquisition on the LTQ-Orbitrap XL Mass Spectrometer

GC/LC-MS: data acquisition rate and peak reconstruction

Staying Connected in GC

Magnum GCMS Training and Operating Instructions 02/07/2012 S.V.

Bruce Quimby. Agilent Technologies October 28, For Forensic Use. Page 1

Technical Note. High-speed Agilent 1100 Series diode-array detector SL for optimization of resolution, sensitivity, spectral sensitivity and linearity

UWPR Advancing Proteomics

PHI 5000 VersaProbe TM Operator s Guide

TL-2900 AMMONIA & NITRATE ANALYZER DUAL CHANNEL

Performance. Reliability. Productivity. Automated Flash Chromatography Systems

ICS-3000 System Installation Qualification

Instrument Control and Data Acquisition with Chromeleon

UNITY 2 TM. Version 1.0. February 2008

Software Operation Manual

Control Unit CU 2.1 User Manual V6850A HPLC

Agilent 7000 Series Triple Quadrupole GC/MS System

Operating pressure should be 6000 psi or better suitable for both analytical and semi-preparative applications

Speed Performance Reliability. Medicinal Chemistry Natural Products Peptides & Polymers Organic Synthesis Purifications

AIM INTRODUCTION SIMPLIFIED WORKFLOW

PAL LSI - Robust and Reliable Sample Handling

If you have questions or problems in providing anything described as Customer

GCxGC Comprehensive Two-Dimensional Gas Chromatography

Scanning Electron Microscopy (FEI Versa 3D Dual Beam)

PAL LSI - Robust and Reliable Sample Handling

BitWise (V2.1 and later) includes features for determining AP240 settings and measuring the Single Ion Area.

Technical Procedure for Scanning Electron Microscope/ Energy Dispersive X-Ray System (SEM/EDX) for non-gsr Casework

Operation Manual for the Refractive Index detector VE-3580

Operation Procedure for Phillips XL30 ESEM

Waters Synapt High Definition Mass Spectrometry System Quick Start Guide

This document is a reference document that shows the menus in the 5500sc, 9610sc and 9611sc analyzers. There are 3 top-level menus:

Agilent G1978B Multimode Source for 6410 Triple Quad LC/MS

NMR. picospin. Maintenance Guide

2.1. Log on to the TUMI system (you cannot proceed further until this is done).

GCxGC Comprehensive Two-Dimensional Gas Chromatography

Agilent G1978B Multimode Source for 6410 Triple Quad LC/MS

FRACTION COLLECTOR. Microcomputer Controlled CHF122SC

Finnigan PolarisQ User s Guide. PN , Revision D

Grace Davison Discovery Sciences. Service Manual Alltech Model 3300 ELSD

Standard Operating Procedure II: EDS (Bruker Flat-Quad)

Processing data with Mestrelab Mnova

How Quadrupole Size Affects Research

Supporting Information for Effectiveness of Global, Low-Degree Polynomial Transformations for GCxGC Data Alignment

Real-time ph and Conductivity Data Acquisition with the ACQUITY UPLC H-Class Bio System, Auto Blend Plus, and the GE Healthcare Monitor ph/c-900

Customer Responsibilities. Important Customer Information. Agilent 1260 Infinity Clinical ed. LC Site Preparation Checklist

SmartMix Manual V5350A

Practicum 3, Fall 2010

Integration of the Zetasizer µv and OmniFACE into an SEC system

1.0 ThermoNicolet Nexus 670 FTIR Spectrometer Instructions

The PHI VersaProbe operates with two essential software programs: PHI Summitt and Vacuum Watcher. A third program, MultiPak, handles data reduction.

E X P E R I M E N T 1

Design of NIR Chromenylium-Cyanine Fluorophore Library for Switch-ON and Ratiometric Detection of Bio-Active Species in Vivo

Quick Guide Book of Sending and receiving card

Creating and fully utilizing the retention time standard processing method for a more automated IC workflow

Kratos AXIS Ultra DLD X-ray Photoelectron Spectrometer Instructions

SEM- EDS Instruction Manual

MAMOS PC SOFTWARE. User manual. Version: /2017 Software version:

Corporate Headquarters Dionex Corporation 1228 Titan Way P.O. Box 3603 Sunnyvale, CA Tel: (408) Fax: (408)

McIDAS-V Tutorial Using HYDRA to Interrogate Hyperspectral Data updated September 2015 (software version 1.5)

Interactive HD-receiver

PS User Guide Series Seismic-Data Display

Ultimate quality control. No compromise. PROCESS / QUALITY CONTROL

University of Minnesota Minnesota Nano Center Standard Operating Procedure

Standard Operating Procedure of nanoir2-s

MestReNova Manual for Chem 201/202. October, 2015.

A6 OPERATING INSTRUCTIONS

Practicum 3, Fall 2012

Infra-Red Vortex-Evaporator. User manual Version 3.4

University of Minnesota College of Science and Engineering Characterization Facility Ganesha SAXSLAB User manual

FIB Operating Procedure. Effective Date: 08/14/2012 Author(s): Jiong Hua Phone:

VISSIM Tutorial. Starting VISSIM and Opening a File CE 474 8/31/06

Printed: File: RI2012 V1.02 english doc Last modified: Makowski

Procedures for conducting User QA on the scanner

Noise. CHEM 411L Instrumental Analysis Laboratory Revision 2.0

JAMAR TRAX RD Detector Package Power Requirements Installation Setting Up The Unit

NGC8206 Start-Up Guide

Online Process Control using Modular Fluid Delivery and Fast Process Gas Chromatography: From the Sample Point to the DCS Connection

HIGH VACUUM PUMPS. Hybrid Turbomolecular Pumps. ATH series. Adixen by Alcatel Vacuum Technology

DektakXT Profilometer. Standard Operating Procedure

DCL9AW. User Manual. English

Precision DeEsser Users Guide

127566, Россия, Москва, Алтуфьевское шоссе, дом 48, корпус 1 Телефон: +7 (499) (800) (бесплатно на территории России)

#PS168 - Analysis of Intraventricular Pressure Wave Data (LVP Analysis)

1.2 Universiti Teknologi Brunei (UTB) reserves the right to award the tender in part or in full.

Commissioning the TAMUTRAP RFQ cooler/buncher. E. Bennett, R. Burch, B. Fenker, M. Mehlman, D. Melconian, and P.D. Shidling

MSQ Plus Mass Detector. Getting Started Guide

TR-SES-200 High Resolution VUV/UV Transmission and Reflection Evaluation System Manual

CHA EVAPORATOR. User guidelines. p.1. by Carlos Manzanedo. Last revised: 10/05/2000

University of Minnesota Nano Fabrication Center Standard Operating Procedure

INSTALLATION REQUIREMENTS - THERMAL ANALYSIS & RHEOLOGY SYSTEMS

Warning & Cautions. Warning. Cautions

FACSAria I Standard Operation Protocol Basic Operation

Transcription:

Liquid Chromatography- Mass Spectrometer Manual Joshua Willis, Elizabeth Sattely Department of Chemical Engineering Stanford University November 6, 2014 Abstract This manual will explain the LC/MS, its features, start-up and shutdown, and making methods and sequences. 1 Features Purge Valve The purge valve, located at the top section of the LC set-up, directs solvent to the waste or to the LC system. To send solvent to the system, turn valve RIGHT. To send solvent to the the waste, turn valve LEFT. Autosampler This system is set up with a 100µL autosampler. This means that 100µL is the maximum sample size. Please note that the door (face) to the autosample section of the LC must be closed for the system to operate. LC Column The column section of the LC has the capability to run the column from 10 C below ambient temperature to 80 C. Note that the temperature the system is measuring is the heating unit of the LC. You should have the column section at your specific temperature for 30min to ensure the column is at the set point temperature. To install a new column: 1. Remove old column or union. 2. While applying pressure to the capillary, tighten the connection. Repeat for the other side of the connection. Solvents Solvents must be a minimum HPLC grade. Preferably, the solvents should be LC/MS grade. If you are leaving the system unused for more than three consecutive days: 1. Remove column and replace column with union. Make sure to apply pressure to capillary the whole time when tightening. 2. Flush system with 100% isopropyl alcohol (IPA) and leave IPA as the mobile phase. 1

UV detector The Dialray detector of the MS has a 190-650nm detection range. Lighting on LC/MS Yellow lights mean not ready. Green lights for all parts of system means run. Red lights means something is wrong. 2 Start-up This section will explain the proper method to start-up the LC/MS system. The LC/MS should be on for a minimum one day prior to using for experiments. This is to allow the system to clean out. 1. Turn on nitrogen (N 2 ) flow behind unit. Nitrogen pressure should be 80-100psi. Make sure to check the pressure holds steady. 2. Plug in the computer and LC/MS power cords. Make sure to becareful plugging in the MS power cord (it is 200V outlet). 3. Turn on computer. 4. Turn on MS. When you push the MS power button, the rough pump (vacuum pump below LC/MS) should turn on first. Keep door to pump open if the ventilation has not been installed. After the rough pump goes on, the turbo pump (pump inside MS) should turn on. If this does not happen contact Agilent. 5. Turn on the LC sections. 6. Once everything is not red, you can open chemstations 3 Shutdown This section will explain the proper method to shut down the LC/MS. 1. Replace column with union (see instructions in features section. Flush system with 100% IPA. 2. Within online chemstations, turn off MS on screen. 3. Go to diagnosis tab. 4. Select Maintance tab, then MSD vent, then More, then Start, and then OK. 5. The MS is now venting. WAIT until the blue timeline is finished. Once the blue timeline is filled, turn off all buttons on LC/MS. 6. Shut off N 2 line. 7. Find and open CSTools.exe and hit Kill chemstation to close chemstations program. This needs to be done because Chemstations will not close otherwise. 2

4 Method Creation Method creation is quite simple because Chemstations walks you through it. Below are the steps you fill follow. You should always start with the default method when making a new method. Once you are done making your new method, use SAVE AS to save your new method. 1. Open either Chemstations (online) or Chemstations (offline). Note that online means you also can control the LC/MS. 2. Open default method. 3. Select Method tab Edit entire method. See figure 1. Figure 1: Red outlined box shows Edit entire method. 4. Making sure everything in the pop-up is checked, select OK. See figure 2. 3

Figure 2: Red outlined box shows what all checked looks like 5. Fill out comments about this method. 6. Always choose Als, which is the autosampler. See figure 3. Figure 3: Red outlined box shows Als selected 7. Quat. Pump section. The pump has a maximum 600bar. However, you should go by the maximum of your column. Stop time is the length of your run. Post time is the amount of wait time. Use the time table to create gradients in solvent. To make an instantaneous switch of mobile phase (solvent), set time in time table to x +.01, where x is the time of the previous step. See figure 4. 4

Figure 4: Red outlined box shows flow rate, green box shows where you can name and select solvents (mobile phases) and blue box shows where you can set up the mobile phase for all the runs 8. Sampler: Set the injection volume (100µL maximum). 9. Column Comp: you will set the temperature you will like for your experiment. See figure 5. 5

Figure 5: Red outlined box shows where you set column temperature. 10. DAD: This is the step where you set the signals you would like to measure. To measure a signal, make sure it is checked. Peak width is how fast you want to collect data points. Selecting ALL will collect all peaks under spectrum. See figure 6. 6

Figure 6: Red outlined box shows where you set the signals to measure and blue outlined box shows where you set peak width. 11. Instrument Curves: This section is where you select the data other than the signals you will like to collect. Always collect pressure data. See figure 7. 7

Figure 7: Red outlined box shows where to check the pressure. 12. MSD Spray Chamber: DO NOT CHANGE 13. MSD Signals: To collect MSD signals, you must have this section checked. To collect a signal, check active signal. SIM measures a target mass. SIM ION is the signal mass. Select SIM on Sample Target Masses. Scan will look at a range of signal masses. See figure 8. 8

Figure 8: Red outlined box is where you select active signals to measure and blue outlined box is where to select scan versus a SIM. 14. No FIA nor Purity. 15. Leave integration on default. You will want to collect data and change data integration of the methods section then. 16. Specify Report: allows you set up how the report from a experiment is printed out. 17. Data aquisition/ data analysis: Set this up in the data analysis tab after the method has been used. 18. You have finished setting up your method. Now you will save the method. Select File tab Save as Method 5 Sequence Creation With a method created, you will want to create a sequence to allow you to run a series of samples fully automated. Again, you start with the default sequence, edit it and save as a new sequence: 9

1. Select Sequence tab Sequence table. Figure 9: Red outlined box shows Sequence Table 2. Column Chooser lets you select the options you wish to set for your sequence. The options you wish to set must be checked. You will want to have the following always selected: Sample Location: location of the sample Sample name: name of sample Method: method to test sample with. Make sure to make and save method prior to making sequence. Injection volume: volume of sample to inject into system. This LC/MS has a 100µL maximum. Inj/Loc: number of times an injection will be taken from this sample Sample type: Target mass: appends the signal in the method to measure without creation of a new method. Data File: Name of file you wish to have it saved as. Please use the following nomenclature [Group Initials] [Sample Type] Hit OK. 10

3. Fill out the options for each sample Figure 10: Red outlined box shows shows all the options to fill out 4. Sequence parameters (under sequence): Use Auto. Check Post-Sequence command/macro. Select STANDBY for Post-Sequence command/macro. See figure 11. 11

Figure 11: Red outlined box Auto selected and blue outlined box shows STANDBY selected under Post-Sequence command/macro. 5. Your sequence is created. Now you will save it: Select File tab Save as Sequence. Please name sequence with the following nomenclature [Group Initials] [Date] Check List BEFORE running Sequence: Solvent Bottles Full in control panel Waste bottle ready (look before computer) Purge valve closed (Turned to right). Rinse Bottle is full and in position 21. 6 Data Analysis To perform data analysis on data: 12

1. Select Data Analysis tab on left side of software window. See figure 12. Figure 12: Red outlined box highlights Data Analysis tab, blue outlined box highlights linear integration tool and green outlined box highlights print icon. 2. Once the Data Analysis is open you can integrate and measure peaks from both the LC (UV detector) and the MS. Use the linear integration tool (see figure 12). To use this tool click the left side, hold and drag to the right side of the peak. 3. Click the print icon to get a print out of data (peak location, peak area, peak width, etc.) (see figure 12). 6.1 Mass Spectrum To visualize the Mass spectra, use the tool (shown in figure 13) and just click the peak you wish to see a mass spectra for. 13

Figure 13: Red the tool to have selected under the spectrum tab to get a mass spectrum for a specific peak. 6.2 EIC: Extracted Ion Content To get a EIC (extracted ion content), the chromatograph for a specific mass, go to file and then select Extract ions... (see figure 14). You will then fill out the pop for the specific range you want for your species. Figure 14: Red outlined box highlights the path to getting a EIC chromatograph. 14

6.3 Extract of Data Extract Chromatogram Click File Export File CSV File... Then select Signal, name your file and then hit OK.. Select the signal you want: DAD is the UV detector, MSD TIC is the total ion content and MSD... EIC is the extracted ion content. You will need all three for all six samples. The file will output two columns: the first is time in minutes and the second is counts. Extract UV and Mass Spectra First use the Select spectrumat peak apex position tool to show the spectra you want. Next click File Export File CSV File... Then select Active Graphic Window, name your file and then hit OK. You must extract every UV and Mass spectra of interest! Make sure to name the file properly to know the difference between them. The file will output two columns: the first is m/z and the second is content. Extract peak area for EIC Peak First make and EIC for the specific mass of interest (see above). Next Then select Integration Results, name your file and then hit OK.. Select MSD1 xxx, EIC=yyy:zzz. Have the following boxes checked: RetTime Area Height Width Your output file will have four columns: RetTime, Area, Height and Width. You NEED the EIC integration for the glucose peak for all samples. Make sure to note HOW you performed your EIC so you know which standard curve to use to get your glucose concentration. 15