USER MANUAL FOR EXPLOSION PROTECTED PENDANT LIGHTING FITTING, TYPE PLFM -.

Similar documents
Pendant Light Fitting IEC Series 6470/2

Operating instructions

Pendant Light Fittings Series 6050

Installation instructions Cable transit device Roxtec RS ES Ex

Inductive sensor NI3-EG08K-Y1-H1341

7 Lighting Technology

Installation instructions Roxtec RS ES Ex

Inductive sensor With analog output BI15-M30-LI-EXI

EXPlora. Introduction

EXLUX ECOLUX C-LUX 6480 Series

Inductive sensor BI1.5-EG08K-Y1

Inductive sensor NI10-M18-Y1X-H1141

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.

EXLUX ECOLUX 6480 Series

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

Lighting: Fluorescent Lighting FD Series: Cylindrical Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Flameproof

Modular pulse operated latching relay 16 A

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

Figure 1: Device components

Horn loudspeaker, Ex proof, short/long flare

EXEL. Ex de. - Double locking system operated by hexagonal-head tool - Double channel electronic ballast - Zones 1, 2, 21, 22. G13 bi-pin lamp holder

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

Heating thermostat Series AMHs B Operating Instructions 11.06/

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

LED MODULES READYLINE DL

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection Part 2 of 2

Installation instructions Ex frames

3 Cleaning. 4 Technical data

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

GOYEN PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS PRODUCT LEAFLET

PMG. Vibration Energy Harvesters

S020 fluorescent tube luminary

Tube Rotator. User Guide. Version 1.2

USER MANUAL. DE-1 Police-light. CAUTION! Keep this device away from rain and moisture! Unplug mains lead before opening the housing!

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

User Manual. Adjustable Speed Vortex. Fixed Speed Vortex

Technical operating data

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

Technical operating data

MKH 8060 Directional studio microphone

Model JDF Field Indicator

Hinges with built-in safety multiple switch SUPER CFSW. Hinges and connections. IP67 RoHS PA

PROPORTIONAL VALVES Sentronic plus

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

Explosion Proof Audible Signal db(a) Series YA60

Benefits. Applications

Revision 1.0 Parts List Mini

Tube Roller Shakers. User Guide. Version 1.2

SubstiTUBE Value EM ST8V-1.2m-17W-EM

8 Installation Equipment

sequenza 1000/1250 al manuale di istruzioni instruction manual 1^ edizione, ottobre st edition october 1996

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

Level Switch. LS Ex KS Ex RS Ex. Manual. AQ Elteknik AB

16 A and 25 A power contactors with or without handle

KRF EMC Filters Installation, Operation and Maintenance Manual

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

SubstiTUBE Advanced ST8-HA4

System 2000 System 2000 HLK relay insert. 1 Safety instructions. 2 Device components. 3 Function. Order No. : Operating instructions

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

HID control gear Electronic. PCIS, PCS outdoor FOX B011 PCI outdoor. Ordering data. Circuit power1. tc/ta for 60,000 h For luminaires with 1 lamp

MID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

RSCC. Load cells. Special features. Data sheet

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Optical Signal Devices. Free-standing Beacons

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

Connecting cables for valves, round plug connectors Product range overview

SubstiTUBE Value EM Fighter Tube Technical Datasheet

MODELS USIX-024 AND USIX-120 INSTRUCTION SHEET FOR FEDERAL SIGNAL UNISTAT STATUS INDICATOR MODEL USIX

Revision 1.0 Parts List Salvador 1~, 3~

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

SubstiTUBE Advanced UO EM ST8AU-1.5m-24W-EM

SubstiTUBE Value ST8-HV5

LIGHTING SOLUTIONS. The bright side of the ship

Linear flow control with actuator IFC

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

Coreline Malaga LED BRP101/102. Time for Coreline Malaga LED

PRODUCT DATASHEET QTi DALI-T/E 2X18 42 DIM

LED Driver Linear / area fixed output

Illustrated Feature. Options

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

1 Safety instructions. 2 Device components. 3 Function. Light Management Relay switch insert 2-channel. Art.-No.: 1202 URE.

Guide for installers. METTLER TOLEDO MultiRange Explosion proof weighing system with IND226x weighing terminal.

Transcription:

d.o.o. tel. 049 900, fax 049 46 450 email: tepex@tepex.hr www.tepex.hr USER MANUAL FOR EPLOSION PROTECTED PENDANT LIGHTING FITTING, TYPE. Doc. No: TEPEx.RS.058 Ver : 0 Date: 11.014. SADRŽAJ 1. Manufacturer 1. General safety information s 1 3. Purpose 4. Product compliance 5. Degree of protection and technical data 6. Type 3 7. Mounting and installation 4 8. Dimension 4 9. Inspection, maintenance, repair and overhaul 4 10. Spare part and accessories 5 11. Responsibility and authorization 6 1. Storage and transport 6 13. Manufacturer's warranty 6 14. Marking 6 1. MANUFACTURER TEP Ex d.o.o. Prilaz dr. Franje Tuđmana 6 HR4910 ZABOK Tel: +385 49 900 Web: www.tepex.hr. GENERAL SAFETY INFORMATIONS W A R N I N G! The user manual contains basic information about the product. Mounting, installation, usage and maintenance should be carried out under this user manual to provide and ensure safe operation within the nominal characteristics. This user manual complement national Regulation and Standards. The responsible person shall ensure their implementation. Failure off implement this user manual can reduce explosion protection and endanger people, property and the environment. Any improper and illegal actions as well as noncompliance with the provisions of this user manual excludes all responsibility by manufacturer side. Before installation/commissioning: Carefully read all instructions, Execute proper training of responsible personnel, Check that the contents of these instructions is fully understandable by the responsible personnel, Make sure that all the requirements and national Regulations as well as all special security measures are applied. In lack of understanding: Contact the manufacturer.

During operation: Ensure that this user manual and other work instructions are available to the responsible staff at all times, Check the implementation of these instructions and all other safety user s instructions 3. PURPOSE Explosion proof pendant lighting fitting, type... is intended for general lighting in industrial with potentially explosive atmosphere, in Zones 1, and in areas endangered by explosive and flammable mixtures of dust and air in Zones 1, accordance with EN 60079101/: 009. 4. PRODUCT COMPLIANCE Design of lighting fitting is accordance with the standard EN 605981:008 and all related standards. The product is in compliance with Regulations concerning equipment and protective systems for use in potentially explosive atmosphere. The product complies with the ATE Directive 94/9 EC and standards: EN 600790:01, EN 600791:007, EN 600797:007, EN 6007931:009. The product has been developed, manufactured and tested according to the existing state of technique accordance with the standards EN 9001:008 and EN ISO / IEC 8007934:011. The product is in compliance with the LV Directive 006/95 EC. The product is in compliance with the RoHS Directive 011/65 EU. The product is in compliance with EMC Directive 004/108 EC. 5. DEGREE OF PROTECTION AND DATA Certificate: Category and explosion protection: Ambient temperature: EA 14 ATE 0056 II G Ex d e IIC T6T3 Gb II D Ex tb IIIC T80 C T155 C Db 0ºC Ta +40 C Mechanical protection: IP66, category 1 Resistance to shock: IK 08 Class of protection: Rated voltage: Rated power: Luminous flux I (PE protective earthing) 30 V (10% / +6%) / 50 Hz FLASH. see selection table see selection table see selection table Wiring: Radox 155 ili Betatherm 155, IEC 608:005 class 5, 1,5mm Connection terminals inside housing: treepole plug and socket terminals for connection L + N + PE;,5mm max, solid, stranded Connection terminals inside Ex e junction box: terminals of multiwire bushing for connection L + N + PE;,5mm solid, stranded it is possible through wiring Ex e cable glands and plugs two Ex e SPU 5 cable glands ISO 5 II G Ex e IIC Gb II D Ex tb IIIC Db for diameter cable Ø715 mm in accordance EN 6444:013 Certificate: EA 14 ATE 0009 two Ex e TEPEx plugs, II G Ex de IIC Gb II D Ex tb IIIC Db in accordance EN 6444:013 Certificate: EA 14 ATE 0009 Connection terminals inside Ex d e adapter ADP 3/1: terminals for connection L + NE + PE;,5 mm, solid, stranded Adapter ADP 3/1: type ADP 3/1, II G Ex d e IIC Gb II D Ex tb IIIC Db, for cable v 715 mm Certificate: EA 14 ATE...U Connection cable for direct entry via Ex d cable entries: connection on treepole plug inside housing for connection L + N + PE;,5mm solid, stranded Ex d cable gland SIB ADR S.A.S II G Ex de IIC Gb II D Ex tb IIIC Db Certificate: LCIE 05 ATE 6146 Tightening torque screws of Ex e terminal 1, Nm screws of Ex e cover of junction box 0,8 Nm

6. TYPE pressure nut of cable gland,5 Nm Ballast: 30V/50Hz 70/50W 1,00/0,76A λ=0,37 tw=130 C ΔT=70/50K in accordance EN 613471:008/A:013, Vossloh Schwabe, GmbH Lamp holder: E7, 50V, 4A, according to EN 6038:004, Vossloh Schwabe, GmbH Dimension: Weight: 339 x 08 x 130 mm 100., 100/1., 100/., 100/3., 0 LED., FLASH. 380 x 08 x 130 mm 70 HSE. 3,5 kg 100., 100/1., 100/., 1003., FLASH. 4,5 kg 0 LED., 70 HSE. Mounting: allowed only vertical mounting 100/1. allowed deviation from the vertical max. 30 100., 100/., 100/3., 0 LED., FLASH..... basic type code maximal wattage and type of sources: 100 A incandescent lamp 100W max, A ECO halogen lamp 105W max, QT halogen lamp 100W max. 100/1 LME mixed discharge lamp 100W max. 100/ TCSB compact fluorescent lamp 3W max. 100/3 LED BULB lamp 15W max. 0 LED LED MODUL special 0W max. FLASH ENON MODUL special 5W max. 70 HSE HSEI high pressure sodium discharge lamp 70W, HSEI high pressure sodium discharge lamp 50W. Type of entries: 1 indirect entry type with Ex e junction box, indirect entry type with Ex d adapter ADP 3/1, 3 direct entry type with Ex d cable gland. Type of reference sources: Model code Max. wattage 100. 100/1. 100/. 100/3. 0 LED. FLASH. 70 HSE. LBT marking Nominal voltage Luminous flux Lamp holder Temp. class (gas) T 0 MA (dust) T a =40 C T a =40 C OSRAM type 100 W A 30V 1340 lm E7 T4 130 C 116 W Osram 105 W Philips A ECO 30 V 135 lm Osram 1980 lm Philips E7 T4 130 C 100 W QT 30 V 1800 lm Osram E7 T4 130 C 100 W LME W Osram 3 W Philips 1 W Osram 13 W Philips TCSB 30 V, 50 Hz 30 V, 50 Hz Halogen Classic A ECO Halolux Ceram Eco 1100 lm E7 T3 155 C 1440 lm E7 T6 80 C Osram Deluxe Intelligent Longlife Parathorm Ledotron Classic A PHILIPS type EcoClassic A shape Another supplier GE Lighting Rough Service GLS Clear ML Mixed Light lamps Master PL Electronic LED 30 V, 810 lm Osram 50 Hz 1055 lm Philips E7 T6 80 C Master LED bulb 0 W LED 30 V, modul 50 Hz 1300 lm T6 80 C 10 100 V DC 5 W ENON 110 V AC 4J/90Hz T6 80 C 30 V AC 70 W HSE 30 V, 5900 lm Osram Vialox NAVE SON 70W I E7 E7 T4 130 C 50 Hz 5600 lm Philips 70W/I CO 1CT 50W HSE 3600 lm Osram Vialox NAVE SON 50W I E7 30 V, 50 Hz E7 T4 130 C 3500 lm Osram 50W/I CO 1CT Vossloh LED LR 4 RS Components Miniature enon beacons

N N L 7. MOUNTING AND INSTALLATION Mounting of the lamp: With vertical suspension on the bolt with ring bolt head M8 witch is twisted in the housing and further blocked from selfloosening Mounting on the tube and blocking it with two M10 screws Before opening the housing, unscrewing the assembly of the protective glass, mechanical release should be carried out by unscrewing the blocking screws M4x14 ISO 407 in the framework of the glass. Removing the lamps is only allowed in the not energized state. Not energized state must be ensured by the exclusion of the voltage at the master switch. It is recommended only to install sources listed in the source table. Electrical connection is made by connecting the power cable to the terminal connection terminals L phase conductor, N neutral, PE protective earth. For direct entry of cable, electrical connection is made by connecting the power cable to the plug. Type 70 HSE is factory wired for High pressure sodium source of 70W and connection diagram is shown in the following figure: ž.z. 1 mm 70W plava 1 mm ž.z. 1 mm smeđa 1 mm plava 1 mm ž.z. 1 mm smeđa 1 mm L plava 1 mm L smeđa 1 mm 30V/50Hz 70W 50W 50W 70W smeđa 1 mm If the user wants to install High pressure sodium source of 50W, it is necessary that the brown phase conductor which is connected to the lampholder E7 is reconnected to the twopole terminal from 70W to 50W. After each opening lamp protective fitting must be protected with "Baplex" protective agents (manufacturer's recommendation).

8. DIMENSIONS 175 175 30 345 361 386 9. INSPECTION, MAINTENANCE, REPAIR AND OVERHAUL Inspections are carried out in accordance with IEC 6007917:014, general and special conditions of manufacturer and users Regulations and includes supervision of parts on which the explosion protection depends, especially: that the housing, all part of housing, replacement glass and gaskets without rupture and damage, that the housing completely closed with replacement glass compound and that mechanical blockage against self opening is done, that the cable gland, plug, adapter, pressure nut of cable gland, screws cover of junction box and connection terminal are fastened with nominal torque. All the repairs are performed by the manufacturer or the manufacturer's authorized personal and the original parts must be provided according to the product documentation, all in accordance with EN 6007919:011. If repair or any other procedure are performed on the product by unauthorized person, all producer responsibility for the product and the warranty and the manufacturer's declaration of conformity becomes invalid. 10. SPARE PART AND ACCESSORIES SKETCH DESCRIPTION CODE SKETCH DESCRIPTION CODE Replacement glass 10 10 plug and socket terminals 10180 Gasket 10 140 Adapter ADP 31 0 110 Heat sink SET 10180 Ex e cable gland SPU 5 SPU 5 Lamp holder 10 150 Ex e plug SPC 5 SPC 5 Ballast SET 10170 Ex d cable gland

100. 100/1. 100/. 100/3. FLASH. 70 HSE. 0 LED. Ex e priključna komora Ex d e adapter ADP 3/1 Ex d uvodnica 11. RESPONSIBILITY AND AUTHORIZATION This instruction is the basic information about the product. It is completed by the corresponding national laws and regulations. Production, use, certification and supervision are determined at the national level: a) Regulations concerning equipment and protective systems intended for use in potentially explosive atmospheres EU directive 94/9 EC (ATE 95) b) Regulations on minimum requirements for safety and health protection of workers and technical inspection of facilities, equipment, installations and equipment in hazardous areas EU directive 1999/9/EC (ATE 137). The responsible person shall ensure their implementation at the working facility. 1. STORAGE AND TRANSPORT Transportation and warehousing of the lamps is only allowed in the original packaging, as outlined in a cardboard box. 13. MANUFACTURER'S WARRANTY The manufacturer provides a warranty on the product for a period of one year under the provisions of this user manual and the law on obligations. This statement has the force of Warranty sheet.

14. MARKING Explosionprotected pendant lighting fitting, type..... is labeled with: warning plate on housing, type 100., 100/1 1, 100/1, 70 HSE.: WARNING DO NOT OPEN WHEN ENERGIZED AFTER DEENERGIZED DELEY FIVE MINUTES BEFORE OPENING warning plate on housing, type 100/., 100/3., 0 LED., FLASH.: warning plate on housing, type 100/13: WARNING AFTER DEENERGIZED DELEY FIVE MINUTES BEFORE OPENING DO NOT OPEN WHEN AN EPLOSIVE ATMOSPHERE IS PRESENT WARNING DO NOT OPEN WHEN ENERGIZED AFTER DEENERGIZED DELEY FIVE MINUTES BEFORE OPENING USE CABLE SUITABLE FOR A MINUMUM TEMPERATURE +90 marking plate with technical data on housing and inside housing: 100. 30V/50 Hz 100W A E7 IP66 II G Ex d e IIC T4 Gb II D Ex tb IIIC T130 C Db 100. 30V/50 Hz 100W QT E7 IP66 II G Ex d e IIC T4 Gb II D Ex tb IIIC T130 C Db 100. 30V/50 Hz 116W A ECO E7 IP66 II G Ex d e IIC T4 Gb II D Ex tb IIIC T130 C Db 100/3. 30V/50 Hz 13 W LED E7 IP66 II G Ex d e IIC T6 Gb II D Ex tb IIIC T80 C Db 100/1. 30V/50 Hz 100W LME E7 IP66 II G Ex d e IIC T3 Gb II D Ex tb IIIC T155 C Db 100/. 30V/50 Hz 3 W TCSB E7 IP66 II G Ex d e IIC T6 Gb II D Ex tb IIIC T80 C Db 0 LED. 30V/50 Hz 0 W LED IP66 II G Ex d e IIC T6 Gb II D Ex tb IIIC T80 C Db FLASH. 30V AC 5 W ENON 50mA IP66 II G Ex d e IIC T6 Gb II D Ex tb IIIC T80 C Db 70 HSE. 30V/50 Hz 70 W HSEI E7 IP66 II G Ex d e IIC T4 Gb II D Ex tb IIIC T130 C Db 70 HSE. 30V/50 Hz 50 W HSEI E7 IP66 II G Ex d e IIC T4 Gb II D Ex tb IIIC T130 C Db 1) entered type of sources ) entered the number of certificates 3) entered the number of individual tests 4) entered a date