HSK Mine and Portable Cable Splice

Similar documents
3M Cold Shrink Foldback Splice Jacket Kit

Cold Shrink Three-Conductor Splice Kit QS-III for use on Armor and Non-Armor Cables Instructions IEEE Std kv Class 250 kv BIL

K & B Flame Retardant Building Riser Closures

3M Cold Shrink Splice Kit QS-III 5416A

3M Scotchcast Flexible Power Cable Splice Kits 82-F Series

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN

3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-4/0-500

3M Cold Shrink Splice Kit QS-III 5515A

Instructions. Cable with Armor F CAUTION. October Rev A

3M Scotchcast Mine and Portable Cable Splice and Jacket Repair Kit M-40

3M Cold Shrink QS4 Integrated Splice Kit QS4-35TS

3M Cold Shrink Splice Kit QS-III 5514A

3M Motor Lead Inline Splice 5331, 5332, 5333 & 5334

Quick Term II Silicone Rubber Termination Kits for Shielded Cables Instruction Sheet

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-2-4/0

3M Cold Shrink QS-III Splice Kit 5467A(S)-WF

Cold Shrink Straight Joint

Crimplok. Connectors. 3M Crimplok ST* Connector Multimode 1. 3M Crimplok SC Connector Single-mode 2

3M Cold Shrink QS4 Integrated Splice Kit QS4-15SP-2-4/0

2178-L/S Series Fiber Optic Splice Case with Gasket

Quick Term III. 3M Cold Shrink 3 Core Indoor Termination. 3.3 kv mm 2

3M Scotchcast Reenterable Signal and Control Cable Splicing Kits 78-R Series

F CAUTION. Jacketed Concentric Neutral (JCN) Cable. Concentric Neutral (CN) Cable. IEEE Std. No. 48 Class 1 Termination 15 kv Class 110 kv BIL

3M Sensored Termination (15 kv) QX-T15I-vi1-E

3M Distribution Box (DDB)

3M Cold Shrink Rubber Splicing Kit 5552

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

Cold Shrink Silicone Rubber Termination QT-II

3M Better Buried Compound Compression Closure System

3M Better Buried Closures

3 Foam Sealed Closure 2" (50 mm) with Compound Compression

2178 Fiber Optic Splice Case and 2181 Cable Addition Kit

3M SLiC 530/533/733-2 Port 0.61 Cable Entry Bracket 3M SLiC 530/533/733-2 Port-MSM 0.61 Cable Entry Bracket

Scotch Heavy Duty Vinyl Electrical Tape 22

3 SLiC Aerial Closure with Rubber End Seal

3M Better Buried Closure (with 3M Scotchlok Shield Bond Connector 4462-FN and 3M High Gel Re-enterable Encapsulant 8882)

2178 L/S Series Fiber Optic Splice Cases and Accessories

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

Industrial Loadbreak Elbow

SLiC Fiber Aerial Closure System

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR

Solutions for Electronic Specialty Markets (ESM)

Quick Term II. Cold Shrink Silicone Rubber Termination (With High-K Stress Relief) Instruction Sheet. Quick Term II. Silicone Rubber Termination Kits

Instruction Guide February 2017

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit

3M 8900 Single-mode SC Crimplok Connector

3M Fiber Optic Splice Tray 2527 with 3M PLC Optical Splitter

Coaxial Cable Feedline Choke Kit - 50 Ω

TFT-150R-G. Tape Shield Cable (page 2) Suggested Installation Equipment (not supplied with kit) Wire Shield Cable (page 7)

3M Coupling Tray FDTC-10S-COUPLINGTRAY

3M Merchandising Catalog. Unrivaled. Product Presence to. Meet Your Merchandising Needs

3M Super 23 Electrical Tape

3M Locator Plate N

Aging test: integrated vs. non-integrated splices shield continuity systems.

Cabinet Tools and Accessories Ordering Guide

LEGEND POWER SYSTEMS

18mm ECAM Cable Entry Port

3M Fiber Optic Closure System LL

SLiC Fiber Aerial Closure 533 and 733

27mm ECAM Double Cable Entry Port

Installation instructions Roxtec RM PE B

PEM1126ENG ENGLISH STPKR. TERMINATION KIT FOR PAPER CABLE WITH LEAD SHEATH 1 kv INSTALLATION INSTRUCTION

Installation instructions Roxtec RM ES B

3M No Polish Jacketed SC/APC Connector


PEM1124ENG ENGLISH. STK TERMINATION KIT FOR PLASTIC CABLE WITHOUT ARMOURING 1 kv STKR TERMINATION KIT FOR PLASTIC CABLE WITH ARMOURING 1 kv

Installation instructions Roxtec CM PE systems

3M Slim Lock Closures

INSTALLATION INSTRUCTION PEM1368ENG ENGLISH

3M Pak 10 Socket 1 mm Straight and Right Angle, Surface Mount PK10 Series

3M Cubitron. II Fibre Disc 982C and 987C Now available in grades 36+, 60+ and 80+ Engineered. Perfection. Epic Performance.

3M Fiber Closures BPEO

Weatherproofing Coaxial Cable Connections

ENERGY /// TRICKS OF THE TRADE TRICKS OF THE TRADE

3M Cross-Connect Cabinets 4220SVB, 4220SVC and 4220SVE Skirt and Stabilizers

INSTALLATION INSTRUCTION PEM1423ENG ENGLISH

Quante BPEO Splice-Protection Closure for Optical Fiber Cables. Features Advantages Benefits

Installation instructions Roxtec RM PE

Instructions for Use of Overlap Seam Repair Kit:

FOSC 450 C6 and D6 Closures

Installation instructions Roxtec RM ES

2016 Cable Splicing Courses

3M Cubitron. II Fibre Disc 982C and 987C. Winner of the 2010 R&D 100 Award & The Editor's Choice Award. Engineered. Perfection. Epic Performance.

FOSC-450D. Fiber Optic Splice Closure. 1 Introduction. Content. 5 Cable termination. 6 Fiber routing. 2 General. 7 Installation of the gel block

Installation instructions Roxtec RM ES systems

Communication Markets Division. 3M Fiber Closures. Smart design makes your job easier.

3M Cubitron. II Fibre Disc 982C and 987C Now available in grades 36+, 60+ and 80+ Engineered. Perfection. Epic Performance.

3M No Polish Jacketed SC/APC Connector

COOPER POWER SERIES. 600 A 15/25 kv class DT625 T-body installation and cable preparation instructions. Deadbreak Apparatus Connectors MN650017EN

Rotor Blade Protection Kit 8999K11

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

3M Cross-Connect Cabinets 4220SVB, 4220SVC and 4220SVE 3M Junction Box (JBOX)

Student Services & Classroom Addition

Sections 1. Application Equipment 2. Cable Preparation 3. Assembly 4. Termination Procedure 5. Inspection 6. Repair 7.

Scotchlok Connectors and Tools

Medium Box for Cable Termination

FIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays

24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual

Transcription:

8096-4-HSK Mine and Portable Cable Splice Instructions 5 and 8 kv rated cables; Type SHD-GC Size 2/0 4/0 (connector max. length 2 1/2") 8096-4-HSK Mine and Portable Cable Splice 78-8119-6296-4-A 1

1.0 Kit Contents: 1.1 Kit Contents are as follows: a) Heat shrinkable tube (1 ea.) b) 1.5" X 10" 80 Grit Abrasive Cloth (1 ea.) c) Scotch Super 33+ Vinyl Tape (1 roll) d) CC-2 Cable Preparation Kit with 120 Grit Abrasive Cloth (1 ea.) e) Cold Shrink Insulator Tube (3 ea.) f) Scotch #13 Semi-Conducting Tape (1 roll) g) Scotch #130C Rubber Splicing Tape (1 roll) h) Scotch #24 Shielding Tape (2 rolls) E F C H A G D B 2

2.0 Kit Contents: 2.1 Slide heat shrinkable tube onto one cable. 2.2 Position cables, cut squarely and remove cable jackets for 10". Remove cable fillers to jacket. 10" 2.3 Scuff, or abrade cable jackets for 6". Use 1 1/2" X 8" 80 grit abrasive. 6" Outer jacket needs to be clean and abraded to obtain good bond. 2.4 Apply two wraps of Super 33+ tape at a distance 4 1/4" from end of each phase. 4 1/4" 2.5 Bend shielding wires back over 33+ tape. Evenly distribute wires and cut to 3/4". 3/4" For tape shielded cables, use #13 tape and cut off shield at end. 3

2.6 Remove color coding fabric and/or semi-conducting cloth 1/4" beyond 33+ tape. 1/4" 2.7 Remove cable insulation for one half of connector length plus 1/4". (Maximum connector length is 2 1/2") 2.8 Pencil insulations for 3/4". PENCILS MUST BE SMOOTH AND EVEN. Use abrasive from CC-2 Kit. Clean and smooth exposed insulations using CC-2 Prep Kit. 3/4" 4

3.0 Splicing: 3.1 Slide Cold Shrink insulator onto phase, one side only. 3.2 Match phase, and join using proper size connector and crimping tool. Grounds and ground check will be joined later. 3.3 Fill crimp indents with rolled pieces of #13 semiconducting tape. Roll up small pieces of #13 tape and apply in crimp indents. This step is necessary to "round out" the connector and prevent flat spots during subsequent tape build-up steps. 3.4 Apply two highly elongated layers of #13 tape over connector. Overlap 1/16" onto pencil. 3.5 Using the 130C rubber tape, build up diameter of insulation between pencils to level of cable insulation. Apply tape 1/16" beyond top of pencil. 5

3.6 Slide Cold Shrink insulator over connector. Tube will grow approximately 1/4" in length as core is removed, so offset starting position 1/4" towards cable shield. 3.7 Wrap one half-lapped layer of #13 tape across Cold Shrink tube, beginning and ending 1/2" onto metallic shield. 3.8 Wrap one half-lapped layer of #24 shielding tape across previously applied #13 tape, beginning and ending 1/2" beyond the #13 tape. Secure the ends of #24 tape with 33+ vinyl tape. 3.9 Repeat steps 3.1 through 3.8 on the other two phases. 6

3.10 Join ground wires with proper connector and crimping tool. Join ground check wires with proper connector and crimping tool and reinsulate connector area with two layers of 33+ vinyl tape. 3.11 Bind phases, ground(s) and ground check together with Super 33+ vinyl tape with the adhesive side out. This step is needed so that all the phases and wires remain flexible within the splice. 4.0 Rejacketing: 4.1 Center heat shrinkable tube and install, using torch. Shrink tube from the center towards the ends. 4.2 Splice is completed. 7

Important Notice All statements, technical information and recommendations related to the Seller's products are based on information believed to be reliable, but the accuracy or completeness thereof is not guaranteed. Before utilizing the product, the user should determine the suitability of the product for its intended use. The user assumes all risks and liability whatsoever in connection with such use. Any statements or recommendations of the Seller which are not contained in the Seller's current publications shall have no force or effect unless contained in an agreement signed by an authorized officer of the Seller. The statements contained herein are made in lieu of all warranties, expressed or implied, including but not limited to the implied warranties of merchantability and fitness for a particular purpose which warranties are hereby expressly disclaimed. SELLER SHALL NOT BE LIABLE TO THE USER OR ANY OTHER PERSON UNDER ANY LEGAL THEORY, INCLUDING BUT NOT LIMITED TO NEGLIGENCE OR STRICT LIABILITY, FOR ANY INJURY OR FOR ANY DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES SUSTAINED OR INCURRED BY REASON OF THE USE OF ANY OF THE SELLER'S PRODUCTS. Electrical Products Division 6801 River Place Blvd. Austin, TX 78726-9000 800/245-3573 Printed on 50% recycled paper with 10% post-consumer 8 Litho in USA 3M 1998 78-8119-6296-4-A