CLASSROOM ACOUSTICS OF MCNEESE STATE UNIVER- SITY

Similar documents
D. BARD, J. NEGREIRA DIVISION OF ENGINEERING ACOUSTICS, LUND UNIVERSITY

Room Recommendations for the Cisco TelePresence System 3210

Getting Started with the LabVIEW Sound and Vibration Toolkit

The acoustics of the Concert Hall and the Chinese Theatre in the Beijing National Grand Theatre of China

Mr. Chris Cocallas University Architect and Director Capital Planning and Construction Colorado School of Mines th St. Golden, Colorado 80401

Coopers Gap Wind Farm AGL Energy Ltd 23-Aug-2016 Doc No AC-RP-02- Facade Sound Insulation Test Report

BACKGROUND NOISE LEVEL MEASUREMENTS WITH AND WITHOUT AUDIENCE IN A CONCERT HALL

HEAD. HEAD VISOR (Code 7500ff) Overview. Features. System for online localization of sound sources in real time

Acoustic concert halls (Statistical calculation, wave acoustic theory with reference to reconstruction of Saint- Petersburg Kapelle and philharmonic)

THE ACOUSTICS OF THE MUNICIPAL THEATRE IN MODENA

Sound Insulation Reporter

APPENDIX O RECOMMENDED GUIDELINES FOR AUDIO/VISUAL TECHNOLOGIES (AV TECHNOLOGY) TABLE OF CONTENTS E. CATV... 8 F. SECURITY SYSTEM...

Preferred acoustical conditions for musicians on stage with orchestra shell in multi-purpose halls

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Methods to measure stage acoustic parameters: overview and future research

What to look for when choosing an oscilloscope

Room Recommendations for the Cisco TelePresence System 3010

Building Technology and Architectural Design. Program 9nd lecture Case studies Room Acoustics Case studies Room Acoustics

Choosing an Oscilloscope

Modular operating rooms Sundsvall Regional Hospital

A BEM STUDY ON THE EFFECT OF SOURCE-RECEIVER PATH ROUTE AND LENGTH ON ATTENUATION OF DIRECT SOUND AND FLOOR REFLECTION WITHIN A CHAMBER ORCHESTRA

FLOW INDUCED NOISE REDUCTION TECHNIQUES FOR MICROPHONES IN LOW SPEED WIND TUNNELS

Precise Digital Integration of Fast Analogue Signals using a 12-bit Oscilloscope

Investigation into Background Noise Conditions During Music Performance

JOURNAL OF BUILDING ACOUSTICS. Volume 20 Number

Acoustic Parameters Pendopo Mangkunegaran Surakarta for Javanese Gamelan Performance

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

SREV1 Sampling Guide. An Introduction to Impulse-response Sampling with the SREV1 Sampling Reverberator

Procedia - Social and Behavioral Sciences 184 ( 2015 )

Calibration of auralisation presentations through loudspeakers

OPTIMUM Power Technology: Low Cost Combustion Analysis for University Engine Design Programs Using ICEview and NI Compact DAQ Chassis

Signal Stability Analyser

INSTRUCTION SHEET FOR NOISE MEASUREMENT

Operating Instructions

Sound and Vibration Data Acquisition

Measurement of overtone frequencies of a toy piano and perception of its pitch

QCTV PROGRAM REPORT. Council Chambers Presentation Audiovisual Systems. Member Cities: Andover, Anoka, Champlin, and Ramsey

The Ideal Videoconferencing Room

Sound and Vibration Data Acquisition

PHYSICS OF MUSIC. 1.) Charles Taylor, Exploring Music (Music Library ML3805 T )

Determination of Sound Quality of Refrigerant Compressors

Using the BHM binaural head microphone

ACOUSTIC ANALYSIS OF R.E.E.L. SEMI-REVERBERANT SOUND CHAMBER. A Thesis SEAN DAVID ELLISTON

REPORT NO CRT-001h SOUND OUTPUT MEASUREMENTS ON SIX INVERTER GENERATOR SAMPLES RENDERED TO

EXHIBIT BASIS OF DESIGN REPORT. Space Type: Space Usage: Approx. 2,000 BTU each. Off-center of room to match side screen.

Experiment 13 Sampling and reconstruction

SUBJECTIVE EVALUATION OF THE BEIJING NATIONAL GRAND THEATRE OF CHINA

Advanced Test Equipment Rentals ATEC (2832)

A Matlab toolbox for. Characterisation Of Recorded Underwater Sound (CHORUS) USER S GUIDE

WELDING CONTROL UNIT: TE 450 USER MANUAL

Performing a Sound Level Measurement

Technical Guide. Installed Sound. Loudspeaker Solutions for Worship Spaces. TA-4 Version 1.2 April, Why loudspeakers at all?

EXHIBIT BASIS OF DESIGN REPORT. Space Type: Space Usage: Off-center of room to match side screen. Location

PIECEWISE PRODUCTION MACHINES

USB Mini Spectrum Analyzer User Manual PC program TSA For TSA5G35 TSA4G1 TSA6G1 TSA12G5

Experiments on tone adjustments

ACOUSTICAL SOLUTIONS IN MODERN ARCHITECTURE

Study of the Effect of the Orchestra Pit on the Acoustics of the Kraków Opera Hall

ACOUSTIC ASSESSMENT REPORT - THE WESLEY MUSIC CENTRE MUSIC ROOM

Major Differences Between the DT9847 Series Modules

Room Acoustics. Hearing is Believing? Measuring is Knowing? / Department of the Built Environment - Unit BPS PAGE 0

Real-Time Spectrogram (RTS tm )

University of Tennessee at Chattanooga Steady State and Step Response for Filter Wash Station ENGR 3280L By. Jonathan Cain. (Emily Stark, Jared Baker)

Concert halls conveyors of musical expressions

Acoustical design of Shenzhen Concert Hall, Shenzhen China

Full Disclosure Monitoring

EASY-MCS. Multichannel Scaler. Profiling Counting Rates up to 150 MHz with 15 ppm Time Resolution.

WiPry 5x User Manual. 2.4 & 5 GHz Wireless Troubleshooting Dual Band Spectrum Analyzer

Sound Level Measurements at Dance Festivals in Belgium

THE EFFECT OF PERFORMANCE STAGES ON SUBWOOFER POLAR AND FREQUENCY RESPONSES

USB Mini Spectrum Analyzer User Manual TSA Program for PC TSA4G1 TSA6G1 TSA8G1

LOUDNESS EFFECT OF THE DIFFERENT TONES ON THE TIMBRE SUBJECTIVE PERCEPTION EXPERIMENT OF ERHU

Measurement of Acoustic Properties of Rooms Using Audio Analyzer R&S UPV Application Note

Wideband Downconverters With Signatec 14-Bit Digitizers

Building Video and Audio Test Systems. NI Technical Symposium 2008

Interface Practices Subcommittee SCTE STANDARD SCTE Measurement Procedure for Noise Power Ratio

MachineryMate 800 operating guide Handheld vibration meter

Acoustics - Vibrations

Table 1 Pairs of sound samples used in this study Group1 Group2 Group1 Group2 Sound 2. Sound 2. Pair

BitWise (V2.1 and later) includes features for determining AP240 settings and measuring the Single Ion Area.

R&S FSW-K76/-K77 3GPP TD-SCDMA BS/UE Measurement Applications Specifications

FC Cincinnati Stadium Environmental Noise Model

Listener Envelopment LEV, Strength G and Reverberation Time RT in Concert Halls

Effectively Managing Sound in Museum Exhibits. by Steve Haas

PicoScope 4000 Automotive PC Oscilloscopes

Laser measurements in the motor bearing diagnostics. Ariel Dzwonkowski 1, Leon Swędrowski 2

The Research of Controlling Loudness in the Timbre Subjective Perception Experiment of Sheng

Trends in preference, programming and design of concert halls for symphonic music

Acoustics of new and renovated chamber music halls in Russia

VOX. Operating manual VOX VOX-01 VOX. IEC rev. 4 IEC Class 2 / ANSI S1.4 Type 2 SPEECH INTELLIGIBILITY TESTER

WiPry 5x User Manual. 2.4 & 5 GHz Wireless Troubleshooting Dual Band Spectrum Analyzer

Instrumentation Grade RF & Microwave Subsystems

Adam Aleweidat Undergraduate, Engineering Physics Physics 406: The Acoustical Physics of Music University of Illinois at Urbana-Champaign Spring 2013

-Technical Specifications-

COMPARED IMPROVEMENT BY TIME, SPACE AND FREQUENCY DATA PROCESSING OF THE PERFORMANCES OF IR CAMERAS. APPLICATION TO ELECTROMAGNETISM

Getting Started. Connect green audio output of SpikerBox/SpikerShield using green cable to your headphones input on iphone/ipad.

ROOM LOW-FREQUENCY RESPONSE ESTIMATION USING MICROPHONE AVERAGING

Detecting and Analyzing System for the Vibration Comfort of Car Seats Based on LabVIEW

1C.5.1 Voltage Fluctuation and Flicker

Effect of room acoustic conditions on masking efficiency

Transcription:

CLASSROOM ACOUSTICS OF MCNEESE STATE UNIVER- SITY Aash Chaudhary and Zhuang Li McNeese State University, Department of Chemical, Civil, and Mechanical Engineering, Lake Charles, LA, USA email: zli@mcneese.edu Acoustical conditions in a classroom have great impact on speech perception and in student learning. In this research a thorough survey was carried out in 80 unoccupied classrooms of eight different buildings at McNeese State University. Experiments were conducted to measure the reverberation time and ambient sound pressure levels. A portable test platform was developed using a ½ microphone, a USB-based data acquisition device, a laptop computer, and software programmed in LabVIEW. The experiments were designed according to the ISO and American national standards. The software saves raw data to the computer hard drive and presents both the A-weighted and C-weighted sound pressure levels. If a thermostat is available in the classroom, then ambient sound pressure levels were measured in two different conditions, air conditioning on and off, otherwise only one condition was measured. While conducting the experiment, classroom doors were closed at all times to avoid any outside noise or interference. The sound pressure level and reverberation time vary depending on the size, finish of the classroom, building, and floor. The results were analyzed and compared with the American national standards. Statistical analyses were conducted. For most of the classrooms, the sound pressure levels and the reverberation time are higher than the criteria set by the American national standard. Recommendations are provided to improve the classroom acoustics. Keywords: classroom acoustics, background noise level, reverberation time. 1. Introduction Various factors affect a classroom s acoustical conditions which further affect the speech perception and learning experiences. Background noise and reverberation time (RT) have the most prolific impact on the ability of a student to concentrate as attention is a flexible and adaptive. In a reverberant space, the reverberation time is normally defined to be the time for the sound pressure level to drop by 60 db when the sound source is cut off. An adequate RT is needed to achieve liveness of the room. However, too much reverberation would reduce clarity and speech intelligibility. This research describes the study of the acoustical conditions of different classrooms at McNeese State University. The study includes an acoustical survey of unoccupied classrooms. Sound pressure levels (both A- and C-weighted) and reverberation times were measured. In this research, we focus on background noise due to the HVAC (heating, ventilation and air conditioning) systems. The results are compared with the ANSI standards to check if the acoustical conditions are adequate and if any improvement is necessary. 1

2. Literature review Many experiments and research work have been carried out on classroom acoustics, optimum reverberation time and background noises. Houtgast [1] determined, from the classroom measurements, that the signal to noise ratio of more than 15 db is desirable for good communication in the classroom. Research done by Bradley [2] shows that to obtain a 100% speech intelligibility, reverberation time should not exceed 0.7 s. Hodgson [3, 4] conducted acoustical measurements in 30 randomly chosen unoccupied classroom in the University of British Columbia. His results showed that the UBC classroom stock is so far from optimum acoustical quality when unoccupied. He found that many classrooms have excessive reverberation and results in low speech levels, especially at the back of the room and noisy ventilation. He found that A-weighted noise level for unoccupied classroom with standard activity is averaged at 37 db. Knecht et. al. [5] compared their results with the limitations recommended in the American National Standard Institute standard for the acoustical characteristic of classrooms in USA (ANSI S12.60-2002). Their results indicated that most classrooms were not in compliance with ANSI noise and reverberation standards. The American national standard ANSI S12.60 Acoustical Performance Criteria, Design Requirements, and Guidelines for Schools regulates that the one-hour average A- and C-weighted background noise levels should be no more than 35 dba and 55 dbc, respectively. Both the A- and C- weighted background noise levels must be satisfied. Reverberation time should be no more than 0.6 s for classrooms with volume less than 10,000 ft 3, and no more than 0.7 s for classrooms with volume more between 10,000 ft 3 and 20,000 ft 3. 3. Experimental setup 3.1 Sensors and software The measurement system consists of the following devices. A PCB 378C20 omnidirectional microphone. The sensitivity is 50 mv/pa. A PCB microphone calibrator CAL200. A USB-based data acquisition device, NI 9234. This device has four 24-bit synchronous channels and each channel can provide ICP constant current power supply for the sensor. Software developed using LabVIEW. The software s user interface is shown in Figure 1. One can adjust the sensor s information, frequency range, frequency weighting. The interface displays the real-time waveform, sound pressure level, and 1/3 spectrum. User can calibrate the microphone, record data to hard drive, and present saved data files. Miscellaneous equipment also includes a tripod for the microphone and a laser distance device to measure the dimensions of a room. Figure 1. User interface of data acquisition software. 2 ICSV24, London, 23-27 July 2017

3.2 Reverberation time Measurements were conducted when the classroom is unoccupied and doors are closed. Clapping technique was used to measure the reverberation time. In the LabVIEW software recording time of 30 seconds was set for small classrooms and 45-50 seconds for large classrooms. Depending upon the classroom size, five to eight claps were done at different locations of the classroom at an interval of minimum five seconds between claps. Acquired data were opened and analyzed in the LabVIEW software. Figure 2 illustrates a typical reverberation measurement, where figure (a) shows the raw time waveform and (b) is the calculated sound pressure level. Two cursors were moved to choose a range of straight-line decay. For each clap the first 5 db decay were ignored. Then a straight-line curve fitting was performed between the two cursors. In Figure 2 (b) the red line is the best straight line by least square algorithm. The reverberation time is the calculated using T 60 60, (1) m where m is the slope of the straight line. The same procedure for all the claps. (a) (b) Figure 2. Reverberation time measurement. (a) Raw time waveform; (b) Sound pressure level and straight line fitting. 3.3 Background noise The experimental setup for background noise was almost the same as that for reverberation time. The HVAC system was the main background noise source considered in this experiment. Measurements were conducted when the classroom is unoccupied and doors are closed at all times to avoid any unwanted external noise. Recording time of 30 minutes was set in the software. Based on the ANSI standard S12.60-2010, both the A- and C-weighted sound pressure levels are required to evaluate the classroom background noise. Therefore, the LabVIEW software records non-weighted noise data to the hard drive, and applies the A- and C-weightings after the 30-minute data acquisition is finished. Then both the A- and C-weighted sound pressure levels are presented. The same procedure was used for all the classrooms. 4. Results and Discussions Table 1 lists the test results of reverberation time and background noise of nine different classrooms in BBC (Burton Business Centre). Except Room 119 whose background noise level is barely acceptable, all other rooms are quite noisy even when the AC is off. Regarding the reverberation time, rooms 120, 201, 301, 304 and 305 require more sound absorption. ICSV24, London, 23-27 July 2017 7

Table 1. Test results of Burton Business Centre 119 7,956 0.622 AC on 36.2 56.8 120 8,872 1.077 AC on 52.5 63.6 AC off 41.5 61.1 121 8,505 0.695 AC on 47.7 60.2 AC off 38.1 56.8 122 6,905 0.695 AC on 56.1 68.3 AC off 53.9 65.9 153 13,910 0.651 AC on 52.1 62.8 AC off 39.6 56.1 201 9,450 1.002 AC off 41.9 59.9 301 9,450 1.002 AC off 41.9 59.9 304 9,450 1.002 AC off 41.9 59.9 305 8,872 1.077 AC on 52.5 63.6 AC off 41.5 61.1 Table 2 lists the test results of reverberation time and background noise of 12 different classrooms in Drew Hall. Seven classrooms have satisfactory background noise when AC is off: 110, 125, 126, 219, 229, 320, and 321. However, when AC is on, all the rooms are quite noisy. Regarding the reverberation time, most of the classrooms are fine except room 320 requires more sound absorption. Table 2. Test results of Drew Hall 107 10,323 0.85 AC on 55.1 66.6 110 6,426 0.728 AC on 54.0 64.0 AC off 33.6 53.9 125 6,417 0.78 AC on 51.7 61.7 AC off 34.4 55.8 126 6,417 0.747 AC on 51.2 68.2 AC off 35.3 53.0 219 7,533 0.696 AC on 55.2 67.9 AC off 32.8 51.8 229 8,190 0.681 AC on 48.4 57.0 AC off 36.2 51.9 303 9,870 0.728 AC on 49.9 63.7 AC off 37.2 61.8 304 9,450 0.540 AC off 41.9 55.9 305 8,872 0.76 AC on 52.5 63.6 AC off 41.5 61.1 320 7,264 0.952 AC on 48.9 61.2 AC off 32.7 49.1 321 7,481 0.74 AC on 49.9 60.8 AC off 33.5 55.4 328 7,238 0.74 AC on 57.5 66.7 AC off 42.6 61.5 4 ICSV24, London, 23-27 July 2017

Table 3 lists the test results of reverberation time and background noise of 12 different classrooms in Farrar Hall. When AC is on, all the rooms are quite noisy except room 112. Regarding the reverberation time, most of the classrooms are fine except room 321 requires more sound absorption. Table 3. Test results of Farrar Hall Room Volume (ft3) RT(sec) Condition dba dbc 112 4,931 0.587 AC on 35.9 56.2 132 5,576 0.623 AC on 48.7 66.8 137 8,516 0.693 AC on 48.8 63.3 141 4,817 0.626 AC on 45.9 60.8 232 5,670 0.496 AC on 34.8 60.2 216 8,100 0.65 AC on 48.1 69.4 221 5,130 0.807 AC on 40.8 67.9 239 6,210 0.611 AC off 41.9 55.9 306 6,750 0.78 AC on 52.5 63.6 AC off 41.5 61.1 321 8,100 1.085 AC on 48.9 61.2 AC off 32.7 49.1 322 7,830 0.698 AC on 49.9 60.8 AC off 33.5 55.4 332 7,290 0.769 AC on 57.5 66.7 AC off 42.6 61.5 Table 4 lists the test results of reverberation time and background noise of Frasch Hall. As half of the building was closed for reconstruction, we only measured four classrooms. The AC is always on and the background noise levels are quite higher than the standard for every classroom. Regarding the reverberation time, most of the classrooms are fine except room 130. Table 4. Test results of Frasch hall Room Volume (ft3) RT(sec) Condition dba dbc 130 24,596 0.986 AC on 44.8 62.3 136 6,928 0.657 AC on 51.9 72.9 138 4,778 0.577 AC on 44.8 64.1 337 6,639 0.648 AC on 45.0 57.7 Table 5 lists the test results of reverberation time and background noise of four classrooms in Hardtner Hall. The AC is always on for every classroom, but the background noise levels are satisfactory except room 304. Regarding the reverberation time, most of the classrooms are fine except room 304 requires more sound absorption. Table 6 lists the test results of reverberation time and background noise of 13 classrooms in Kirkman Hall. All the classrooms have unsatisfactory background noise levels. Regarding the reverberation time, most of the classrooms are fine except rooms 108, 109, and 115 require more sound absorption. ICSV24, London, 23-27 July 2017 7

Table 5. Test results of Hardtner Hall 103 15,800 0.646 AC on 37.6 55.8 104 15,800 0.596 AC on 36.4 55.7 106 6682 0.702 AC on 36.7 52.7 304 8463 0.969 AC on 42.9 64.3 Table 6. Test results of Kirkman Hall 107 7,841 0.77 AC on 37.8 59.6 108 7,349 0.95 AC on 36.7 59.8 109 7,349 0.95 AC on 36.7 59.8 111 7,168 0.69 AC on - - AC off 38.5 62.1 115 7,349 0.95 AC on 36.7 59.8 123 6,518 0.7 AC on 52.2 68.6 AC off 44.1 66.0 124 6,518 0.77 AC on 52.2 68.6 AC off 44.1 66.0 126 6,128 0.73 AC on 41.4 62.4 140 5,343 0.58 AC on 43.4 63.1 200 7,013 0.567 AC on 42.6 67.3 202 7,347 0.792 AC on 45.7 65.0 203 6,473 0.684 AC on 44.8 69 204 8190 0.593 AC on 41.6 65.0 Table 7. Test results of Kauffman Hall 200 5,116 0.636 AC on 38.3 54.9 201 8,224 0.58 AC on 47.6 62.2 202 8,403 0.616 AC on 46.9 61.3 203 5,016 0.628 AC on 48.7 63.4 205 5,671 0.789 AC on 36.4 54.8 207 5,787 0.632 AC on 49.0 65.0 208 5,328 0.618 AC on 49.3 65.1 214 9,769 0.969 AC on 44.6 64.4 215 9,770 0.943 AC on 45.2 68.4 216 6,697 0.859 AC on 47.4 63.0 217 6,733 0.961 AC on 39.9 60.6 219 6,758 0.879 AC on 48.8 65.1 220 6,690 0.794 AC on 50.1 65.3 322 9,769 0.969 AC on 44.6 64.4 327 6,714 0.94 AC on 48.8 66.3 6 ICSV24, London, 23-27 July 2017

Table 7 lists the test results of reverberation time and background noise of 15 classrooms in Kauffman Hall. The AC is always on for every classroom. Although reconstruction was done two years ago, only two classrooms have satisfactory background noise: 200 and 205. In addition, many rooms also suffer from long reverberation time: 205, 214, 215, 216, 217, 219, 220, 322, 327. Table 8 lists the test results of reverberation time and background noise of 11 classrooms in Gayle Hall. It can be seen that all these rooms suffer from bad acoustics. Table 8. Test results of Gayle Hall Room Volume (ft 3 ) RT(Sec) Condition dba abc 104B 34,302 1.174 AC on 41.8 60.4 104C 16,602 1.073 AC on 36.3 58.9 203 6,518 0.856 AC on 47.5 55.7 AC off 45.0 52.2 206 9,067 0.938 AC on 48.1 60.0 AC off 46.3 53.3 212 14,577 0.673 AC on 43.3 55.2 301 8,941 0.968 AC on 45.4 56.5 AC off 38.9 52.2 302 11,710 0.908 AC on 48.8 57.0 AC off 47.1 53.2 303 6,255 0.924 AC on 47.9 58.0 AC off 40.7 54.6 304 5,961 0.822 AC on 45.8 57.8 AC off 40.0 52.1 305 6,261 0.885 AC on 46.9 57.8 AC off 37.9 52.3 308 11,191 0.52 AC on 45.5 55.5 AC off 40.4 52.9 Based on the data shown above, statistical analysis results can be summarized as follows. There are 70 classrooms that are less than 10,000 ft 3. Reverberation times are in a range from 0.5 s to 1.1 s with average 0.77 s and standard deviation 0.15 s. Only 9 classrooms (12.9 %) satisfy the ANSI S12.60 requirement (RT 0.6 s). There are 9 classrooms whose volumes are between 10,000 ft 3 and 20,000 ft 3. Reverberation times are in a range from 0.52 s to 1.07 s with average 0.81 s and standard deviation 0.22 s. Five classrooms (55.6 %) satisfy the ANSI S12.60 requirement (RT 0.7 s). A two-sample t-test indicates that the reverberation times of smaller classrooms are not significantly less than those of larger classrooms (p value is 0.326). For classrooms with AC on (79 samples), the A-weighted background noise levels are in a range from 34.8 dba to 57.5 dba with average 50.2 dba. The C-weighted background noise levels are in a range from 52.7 dbc to 72.9 dbc with average 64.2 dbc. For classrooms with AC off (35 samples), the A-weighted background noise levels are in a range from 32.7 dba to 53.9 dba with average 42.9 dba. The C-weighted background noise levels are in a range from 49.1 dbc to 66 dbc with average 59.5 dbc. Two-sample t-tests indicate that the background noise levels with AC off is significantly less than those with AC on. Figure 3 and Figure 4 compare the histograms of background noise levels with and without AC. ICSV24, London, 23-27 July 2017 7

14 12 12 10 10 8 frequency 8 6 frequency 6 4 4 2 2 0 30 35 40 45 50 55 60 A-weighted background noise level - AC on Figure 3. 0 30 35 40 45 50 55 A-weighted background noise level - AC off A-weighted background noise of classrooms frequency 8 7 6 5 4 3 2 1 frequency 20 18 16 14 12 10 8 6 4 2 0 48 50 52 54 56 58 60 62 64 66 C-weighted background noise level - AC off 5. Conclusions Figure 4. C-weighted background noise of classrooms A detailed survey of the acoustical condition of classroom was carried out for 80 classrooms at McNeese State University. The results of the classroom acoustical survey show that the overall acoustical quality of unoccupied classroom is far from optimum. Many classrooms have excessive reverberation time. This problem can be solved by increasing the sound absorption areas in these classrooms. The most effective way is to upgrade acoustical ceiling tiles with high NRC (e.g. 0.9 or 0.95). The amount of sound absorption will be calculated in the next phase of the project. Many classrooms have high background noise level due to the ventilation system. This is a more serious problem. First, there are various HVAC noise sources: fans, duct radiation, flow noise, etc. Second, the ductwork is either above suspended ceilings or in shafts. So they are more difficult to access. In addition, the resolutions to HVAC noise are more expensive. In the next phase of the project, the noise mitigation methods will be recommended. REFERENCES 0 50 55 60 65 70 75 C-weighted background noise level - AC on 1. Houtgast, T. The effect of ambient noise on speech intelligibility in classrooms, Applied Acoustics, 14(1), January February 1981, pp. 15-25 2. Bradley J.S. Speech intelligibility studies in classrooms, J Acoust Soc Am. 1986 Sep; 80(3), 846-854. 3. Hodgson, M. Experimental investigation of the acoustical characteristics of university classrooms. J. Acoust. Soc. Am. 106, 1810 (1999). 4. Hodgson, M. Rating, ranking, and understanding acoustical quality in university classrooms. J Acoust Soc Am. 112(2):568-575 (2002) 5. Knecht, H.A, Nelson P.B, Whitelaw GM, Feth LL, Background noise levels and reverberation times in unoccupied classrooms: predictions and measurements. Am J Audiol. 2002 Dec;11(2):65-71. 8 ICSV24, London, 23-27 July 2017