Elektralite LED Cool White Dazer

Similar documents
Elektralite Dazer Downlight Warm White

ElektraLite LED Dazer RGB

ElektraLite lightstream

LED Thunder S-150 Code 1097

LED Spot 300W. Please read this user manual before your operation

MB150 USER MANUAL (V2.00) Elektralite 70 Sea Lane, Farmingdale N.Y U.S.A. Tel (+1) Fax (+1)

LED Beam Moving Head. TWIST-150LED Order No INSTRUCTION MANUAL

Fixture One XLR Signal Cable One Omega Clamp - Two Safety Chain One User Manual - One

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

1. Safety Instructions Installation Features Remote Control Operation Menu Operation DMX Table 5

Fusion 120 Zoom. User Manual. Order code: EQLED068

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

Page 1 of 6 FXLD618FRP2I4 LED FIXTURE Version 0.2 OWNERS MANUAL 10/04/17

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

PRODUCT SPECIFICATIONS

Spectra Flood Q40. Exterior Fixture User Manual. Order code: LEDJ Version LEDJ284N - 15 Version

User Manual. 360W LED Moving Zoom KEEP THIS MANUAL FOR FUTURE NEEDS. 36pcs10W 4 in 1 RGBW LEDs

BEAM MOVING HEAD YODN Lamp. 132W 2R MOVING HEAD Brightness / Stability USER MANUAL. Version 1.0 beta

Mini LED Pin Spot Light Model: PLS00571

Spectra Batten (Order code: LEDJ95)

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA

PRODUCT SPECIFICATIONS

LED IP65 Slimline Par RGBWA +UV 7x12W

DMX LED light effect with 4 lenses

Stage Wash 7x 10W LED Moving Head (RGBW)

PRODUCT SPECIFICATIONS

MY 250 USER MANUAL (V1.12)

Mover Beam 7 CKU (US) / CKE (EU) USER MANUAL

Commander 384. w w w. p r o l i g h t. c o. u k U S E R M A N U A L

aorun manual V2.0 MARCH 2018

CLF Manuals CLF Colour Par CLF Colour 12 Par CLF Colour Par 12 Version 1.0 November 2012 Version 1.0 1

180w led gobo moving USER MANUAL

TABLE OF CONTENTS PART 5 APPENDIX TROUBLE SHOOTING MAINTENANCE A CTIVATE THE PASSWORD...13.

Quick Reference Guide

ORDER CODE: EQLED65 USER MANUAL

BEAM MOVING HEAD WITH 100W OSRAM HRI LAMP AND 8-FACET PRISM USER GUIDE

80W SPOT MOVING HEAD CYCLONE-80 USER GUIDE April 2014 version

Stratos Duo RGB. User Manual. Order code: EQLED371

LED MOVING HEAD LedWash. 36 x 10w RGBW 4in1 Zooming USER MANUAL. Version 1.0 beta

ORLAND SCAN PR PR LIGHTING LTD. Yingbin Road, Dashi Panyu, Guangzhou, China

SquareLED - Aura Bar & Matrix Beam Light 100

LED Pixel Track Pro ORDERCODE 42205

KingWash 7QX 7x40w,Zoom 5-60degree. User manual. Please read the instructions carefully before use TABLE OF CONTENTS

Stage Right Party 10-Watt Mini Beam Moving Head LED Light

LED SPOT HEAD USERS GUIDE

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do

LED ZOOM PAR Please R ead O ver T his M anual B efore O perating T he L ight F ixture.

USER MANUAL. TS-3 DMX-Scanner. For your own safety, please read this user manual carefully before you initial start-up.

Venus W36 LED Moving Wash

Mini Stage Par 4 8W QCL RGBA/RGBW 25 /40 LED PAR. user manual

JunoScan MK-II LED scanner. user manual

LEDWash RGBW USER MANUAL

YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE POWERING OR INSTALLING. SAVE IT FOR FUTURE REFERENCE

Color Ground 12T 16 A USER MANUAL 5 APPENDIX 5.1 TROUBLE SHOOTING 5.2 MAINTENANCE LED MODULE. Version 1.0 SITUATION CAUSE ACTION 5 APPENDIX

Octagon Theater CW/WW/A 20 6W LED PAR. user manual

DMX Operator 192-channel lighting controller

LED Pot 12 1W RGBW LED PAR. user manual

SUPER LED F4.7 VW Vari-White INSTRUCTION MANUAL

EPAR QW. User Instructions

LED Par 36 COB RGBW 12W, LED Par 46 COB RGBW 20W, LED Par 64 COB RGBW 60W, LED Par 56 COB RGBW 30W LED PAR. user manual

This device is a lighting effect for professional use on stages, in discotheques, theatres, etc..

4-PROJECTOR BAR WITH 3 X 9W LEDS AND 1 X 1W FLASH LED USER GUIDE

Opti Tri White Par. User Instructions

WaferPar HEX 12 CKU (US) / CKE (EU) USER MANUAL

AuraBeam 150 LED. User Manual KEEP THIS MANUAL FOR FUTURE NEEDS

MH-X50+ LED spot moving head. user manual

www. eklights.com Guangzhou Liangyi Lighting Equipments Co.,Ltd. 37 Gongyedadao, Xinhua, Huadu, Guangzhou PC:510800

USER MANUAL. DE-1 Police-light. CAUTION! Keep this device away from rain and moisture! Unplug mains lead before opening the housing!

LED SPOT HEAD USERS GUIDE

aorun manual V1.0 OCTOBER 2017

HEX16 Strip User Manual

2002 Martin Professional A/S, Denmark.

Owner Handbook. Jupiter Blackhole. LED UV Flood

EPAR QA. User Instructions

User Manual MAINTENANCE AND CLEANING. CAUTION Disconnect from mains before starting maintenance operation. KEEP THIS MANUAL FOR FUTURE NEEDS

TABLE OF CONTENTS. Returns Contact Us Page 2 of 21 Intimidator Spot LED 450 User Manual Rev. 2

LED Spot Light User Manual Model LS90 Big Dipper Laser Science And Technology Co., Ltd Please read this manual carefully before operating

APOLLO DESIGN TECHNOLOGY 4130 Fourier Drive Fort Wayne, IN USA Phone: Fax:

SPECIFICATIONS: Model: Supply Voltage: LED: Weight: Size: Fuse: Power Consumption: Working Position: Duty Cycle: DMX Channels:

PROFESSIONAL SCANNER USER S MANUAL

PART 1 PRODUCT (GENERAL)...1.

USER MANUAL Table of Contents

1440/2880 HP RGB+WW+CW

PRO PAR HEX 12. User Manual

VRL PAR-1745 Par Lamp

Introduction: The Dekker is part of American DJ s continuing pursuit for creating high quality affordable intelligent fixtures.

Colour Control48 Order Code: Control48

ALO 060 DMX LED scanner

Stage Right Party Mini-Spider 3W LED Light (RGBW)

Event Bar Q4. User Instructions

USER MANUAL. B-EYE Light. Please Read Over This Manual Before Operating The Light Fixture

LED Spere Direct Control 30 ORDERCODE 41125

KEEP THIS MANUAL FOR FUTURE NEEDS

Package Contents. LED Protocols Supported. Safety Information. Physical Dimensions

Stage Flood QCL 24x10W, Stage Flood Inst QCL 24x10W LED floodlight. user manual

SHOWLINE SL BEAM 100 LED LUMINAIRE SPECIFICATIONS.

MHL-1410WISPOT 14X 10W QUAD DMX 2.4GHZ

American DJ. User Instructions. Model: Mega Bar 50RGB

ArtFox Lighting. LED Beam Wash 19E. User manual. 6. Fixture Cleaning. Please read the instructions carefully before use

1. BEFORE YOU BEGIN INTRODUCTION SETUP... 7

Transcription:

Elektralite LED Cool White Dazer USER MANUAL Elektralite (a division of Group One), 70, Sea Lane, Farmingdale, NY11735, U.S.A. T. +1 (631)-396-0184. F. +1 (631)-396-0190 WWW.MYELEKTRALITE.COM

1. Unpacking Thank you for choosing the Elektralite Led Pro Line Cool White Dazer fixture. For your own safety, please read this manual before installing the fixture. This manual covers important information on installation and applications. Please keep this manual for future reference. To keep this simple, we are going to refer to the fixture as the Elektralite CW Dazer throughout the manual. The Elektralite CW Dazer fixture uses 36 high powered 5 watt leds in a balanced arrangement giving incredible output. Please unpack it carefully and check whether it was damaged in shipping. The following items should be in the box with the fixture:- Color/Gel frame DMX 5 pin male to 5 pin female cable 2. Safety Instructions. This device has left the factory in perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual. The Elektralite CW Dazer is a high voltage fixture. Be careful when dealing with high voltages. Please read this manual. If you do not read this manual and damages occur to the Elektralite CW Dazer, then it could void the warranty. During shipping, Elektralite CW Dazer may have been exposed to high temperature changes or humidity changes. So, as a precaution, do not switch Elektralite CW Dazer on immediately. Condensation can damage Elektralite CW Dazer so leave it switched off, until it has reached room temperature. The electric connection must be carry out by a qualified person and it is absolutely essential that the Elektralite CW Dazer be grounded. This is imperative and is a safety issue. Do not break or bend out of the way, the ground center pin on the plug. Always disconnect the Elektralite CW Dazer from the power source, when the device is not in use or before cleaning it. Only unplug Elektralite CW Dazer from the power cord. Never pull out the plug out by pulling on the power cord. Please keep the Elektralite CW Dazer away from children and the general public. Please be intelligent and use common sense when operating the Elektralite CW Dazer. 3. General Guidelines. The Elektralite CW Dazer is a lighting fixture for professional use on stages, in churches, theatres, etc. The Elektralite CW Dazer should only be operated at between 120 to 240 volts and only indoors. The Elektralite CW Dazer should not be operated 24/7 (24 hours a day; 7 days a week). The Elektralite CW Dazer needs operation breaks to ensure that it will work for a long time without problems. Please do not shake the Elektralite CW Dazer and avoid using brute force when installing or operating it. When choosing the location to install the Elektralite CW Dazer, please make sure that it is not exposed to extreme heat, moisture or dust. The minimum distance between the Elektralite CW Dazer and the illuminated surface must be more than 3 feet. Always mount the Elektralite CW Dazer with an appropriate safety cable/chain. Operate the Elektralite CW Dazer only when you are familiar with the features on the fixture. Do not permit operation by persons not qualified to operate it. All modifications to the Elektralite CW Dazer will invalidate the warranty. There are absolutely no exceptions. If Elektralite CW Dazer is operated in any way different to the one described in this manual, the Elektralite CW Dazer maybe damaged and the guarantee will be void.

4. Installation Please ensure that the Elektralite CW Dazer is hung using the appropriate "C" clamp or half cheeseboro. A safety chain or cable should also be used as a secondary point of holding the fixture in case the clamp comes loose. Never hang the fixture without a safety chain or cable. Make sure the Gel frame (Gel holder) is clipped into position correctly and cannot come loose. If you are not qualified or have any doubts about hanging the Elektralite CW Dazer then do NOT hang it. Do not clamp the cable to the U bracket or clamp. That is not a secondary safety point. A secondary safety point is any point that will adequately hold the Elektralite CW Dazer if the "C" clamp or half cheesboro fails. Then the safety cable would be the backup and stop the fixture from falling to the ground. So do NOT fix the safety to the same place that the "C"clamp is attached. Installation during construction. Many times fixtures are installed during the construction phase of a building. It is imperative that the fixture is protected during this phase. A lot of dust is usually created. This dust can adversely affect the fixture. Specifically, of course, in coating the lenses and therefore reducing the output. However much more seriously, dust, like sheetrock dust, can get inside the fan bearings especially if the fixture is being operated during construction. Sheetrock dust, mixed with the grease of the fan motor, will result in the fan s premature failure and that is not covered under the fixture s warranty. It is therefore strongly advised to keep the fixtures covered up during the construction phase and not used. 5. Grounding. Always make sure that there is sufficient grounding (earth) for the fixture. This is not only imperative within the circuit that the fixture is being connected to, but also make sure there is sufficient grounding into the building. All fixtures regardless of manufacturer have a surge at initial turn-on. Once initial turn-on is complete, the surge current (per fixture) will travel down the ground. While each 20 Amp circuit may have the correct size of ground wire, the ground input to the building and/or electrical panel may not be sufficient for the job. Please review this with the electrical contractor. The Elektralite CW Dazer has a surge current over and above its operating current of approximately 2 Amp at 120 volts. If an installation has 100 Dazers that means 200 Amps needs to be dissipated through the GROUND WIRING. If there is a lack of a sufficiently big enough ground cable into the building or on the individual circuits it can cause severe damage to the fixture and this is not covered under the warranty. One further check : the ground to neutral voltage for each circuit. In a lot of buildings, voltages across these can damage fixtures or cause operational problems both for the fixture and DMX. Please review these two important points with a qualified electrical contractor. If in any doubt, have an independent qualified third party electrical contractor check the installation, well before commencing installation. Circuit Limitation :- There should be no more than 5 CW Dazers on a 20 amp 120 volt circuit, having no other load on it. That means to say a, maximum of 5 CW Dazers are on a 20 amp 120 volt circuit with nothing else plugged into that circuit.

6. DMX-512 Control Connection Connect the provided XLR cable to the female 5-pin XLR output of the Elektralite CP 16/24 or other DMX controller. The other end should be connected to the male 5-pin XLR input of the Elektralite CW Dazer. Then daisy-chain out of the first Elektralite CW Dazer and into the next Elektralite CW Dazer or other dmx device. Never Y split the DMX connection. If you need more cable, then it should be two core, screened cable fitted with a 5 pin XLR input and output connector. Please refer to the diagram below. 5 4 1 2 3 DMX-512 connection with DMX terminator For installations where the DMX cable has to run a long distance or is in an electrically noisy environment, it is recommended that a DMX terminator is used. This helps prevent corruption of the digital control signal. The DMX terminator is simply a 5 pin XLR plug (male) with a 120 Ω resistor connected between pins 2 and 3. It is then plugged into the output XLR socket of the last Elektralite CW Dazer or other dmx device in the chain. Please see illustration below. 5 4 3 1 2 120

7. Menus in the fixture. Root Menu Sub Menu 1 Sub Menu 2 STAT (STATIC LOOK) W(HITE) 0-255 S(STROBE) 0-255 RUN DMX STMT DMX ASSIGN DMX CHANNEL 1-512 PERS (PERSONALITY) WD WS WS Id ID ID 01 THROUGH 255 1-255 SET REST (RESET) DV DIM KEY OFF ON 8. Static Look. The Elektralite CW Dazer can be set to a single static look quickly. Use the Menu button to get to STAT. Press Enter. The next screen will read W.000. This is addressing the White leds. Use the or to increase or decrease the output of the leds. Numbers are expressed in DMX values so 0 is no output and 255 is highest output. Press Enter to save the value. The screen will automatically advance to the strobe. S.000 means the strobe is off Use the or to increase or decrease the speed of the strobing or leave at S.000 if you want no strobe. S.001 is the slowest and S.020 is the fastest strobing. Press Enter to save the value. It will automatically bring you back to the output screen again. Press the Menu button to exit out of STAT and back to the Root directory. 9. Run Mode. Run allows the fixture to operate in either DMX or STMT. DMX Mode is where control of the fixture is via the industry standard DMX signal. Further, when the DMX signal is lost, the fixture will maintain the last refresh of the DMX signal prior. This way the facility is not plunged into total darkness. In STMT Mode, when the DMX signal is lost, the fixture will go to whatever the output values are set at in the STATIC LOOK. STMT mode is good in an emergency. If the fixtures are in a venue that needs, in an emergency, the lights to come FULL ON, then engage STMT mode and also make sure that the STATIC LOOK is set such that all leds are at 255. (See #8 Static Look above). Using the Menu button in the root menu go to RUN. Press Enter to get to DMX mode. Press Enter again to save the RUN mode as DMX. A "ok" will appear and then the display will return to display RUN. If the fixture is to be run in STMT mode, then when DMX mode appears on the screen instead of pressing enter use the or to get to STMT. Then press enter to save the STMT mode setting.

10. DMX 512 Setting (address). Sets up the address for the dmx. Using the Menu button in the root menu go to DMX Press Enter to get into DMX menu and the display will read the current dmx channel. The display will read for example d.001 This means the fixture's current address is 001 To change it, use the or buttons to get to the correct address. Press Enter to save the dmx address. The display will momentarily display the word "OK" and then go back to the DMX menu. To exit out to the root directory, use the menu button. 11. Fixture Personality. There are several different choices on how the fixture will operate. What these "Personalities" do in terms of their channel assignments is detailed on the tables page 8. To change a Personality use the Menu button to get to PERS Press Enter and then using the or buttons go to the personality required. Press Enter to save the Personality. 12. ID Address. A fixture can be addressed (controlled) through the dmx or instead it can have its own unique ID address. There are a total of 255 different ID addresses from 1 to 255. To set up the address for a fixture, use the Menu button in the root menu go to ID Press Enter and then using the or buttons,to select the ID address. Press Enter to save the address. For the ID address to work you must chose the WS id personality. This allows you to access the ID address system on channel 4. Set the DMX address to d.001 for the fixture. So if ID address 123 is chosen then go to channel 4 on the lighting board and set the level at 123. You will then be controlling only fixture(s) with ID address 123.

13. SET. (Set has several Sub Menus which allow functions to be used). 1). REST This resets all values to their default. Using the Menu button, go through the Root Menu until SET. Press Enter and then use the or buttons to get to REST. Press Enter. The display will have 4 dots across the bottom. The password needs to be entered. The password is the following sequence using the and buttons. then press Enter once, to complete the reset. The display will read "OK" followed by a return to the REST sub menu. The Menu button will need pressing to return to the Root Menu. Only when at the Root Menu will dmx control work. Please note the Reset also takes the dmx address back to 001. 2). DIM The Dim function allows different Dimmer curves to be chosen. There are 5 choices. Choice 1 :- this is Dim off. The Dimmer curve is 0 which means any change in dimmer level is instantaneous. Choice 2:- Dim 1. The dimmer curve has the shortest fade in and fade out time. Choice 3:- Dim 2. The dimmer curve has the 2 nd shortest fade in and fade out time. Choice 4:- Dim 3. The dimmer curve has the 3 rd shortest fade in and fade out time Choice 5:- Dim 4. The dimmer curve has the longest fade in and the fade out time. Using the Menu button, go through the Root Menu until Set. Press Enter and then use the or buttons to get to DIM. Press Enter and then use the or buttons to get to the DIM choice required. Once chosen, press Enter to save it and then use the Menu button to exit back to the root directory. 3).DV The DV setting allows the ability of the leds to not flicker when using video camera. The choices are NTSC or PAL. NTSC is the USA system. Go through the Root Menu until Set. Press Enter and then use the or buttons to get to DV. Press Enter and then use the or buttons to get to either NTSC or PAL. Once chosen, press Enter to save the setting and the Menu to exit back to the Root Menu. 14. KEY The Key function is an access password for the fixture. The KEY can be turned OFF or ON which then deactivates or activates the password. To set the KEY go through the Root Menu until KEY, press Enter and use the or to set the KEY to either OFF or ON. If the Key is turned ON then a password is required to go into sensitive Menus and to change functions. The password is (Up + Down + Up + Down) 15. Glass front plate. Certain fixtures come with a glass plate. This glass plate fits onto the front of the leds. It slots in the gel frame holder and the clip latches the plate into position.

16. The Personalities of the CW Dazer. WD 1 0-255 Dimmer 0-50 Linear dimmer speed(dim=off) 51-100 nonlinear speed1(dim1) 2 101-150 nonlinear speed 2(DIM2) 151-200 nonlinear speed 3(DIM3) 201-255 nonlinear speed 4(DIM4) WS 1 0-255 Dimmer 0-9 No Function 10-49 Synchronized strobe slow 2 50-99 Non synchronized strobe slow 100-149 Random strobe slow 150-199 Non synchronized fast strobe 200-255 Synchronized fast strobe 0-50 Linear dimmer speed(dim=off) 51-100 nonlinear speed 1(DIM1) 3 101-150 nonlinear speed 2(DIM2) 151-200 nonlinear speed 3(DIM3) 201-255 nonlinear speed 4(DIM4) WS Id 1 0-255 Dimmer 0-9 No Function 10-49 Synchronized strobe slow 2 50-99 Non Synchronized strobe slow 100-149 Random strobe slow 150-199 Non Synchronized strobe fast 200-255 Synchronized strobe fast 0-50 Linear dimmer speed(dim=off) 51-100 nonlinear speed 1(DIM1) 3 101-150 nonlinear speed 2(DIM2) 151-200 nonlinear speed 3(DIM3) 201-255 nonlinear speed 4(DIM4) 0 All ID address work together 4 1-255 Each dmx value is an ID address value. Each ID address is controlled individually at that DMX value

17. DMX Channel Assignments. Depending on the Personality chosen, the Elektralite CW Dazer can be 2, 3 or 4 channels. Personalities:- WD = 2 channels (the first two channels listed below) WS = 3 channels (the first three channels listed below). WS is the most common choice. WS Id = 4 channels (as listed below all 4 channels) 1 0-255 Dimmer 0-9 No Function 10-49 Synchronized strobe slow 2 50-99 Non Synchronized strobe slow 100-149 Random strobe slow 150-199 Non Synchronized strobe fast 200-255 Synchronized strobe fast 0-50 Linear dimmer speed(dim=off) 51-100 nonlinear speed 1(DIM1) 3 101-150 nonlinear speed 2(DIM2) 151-200 nonlinear speed 3(DIM3) 201-255 nonlinear speed 4(DIM4) 0 All ID address work together 4 1-255 Each dmx value is an ID address value. Each ID address is controlled individually at that DMX value

18. Cleaning and maintenance. Now ignoring maintenance and cleaning is very good way of creating problems "down the road" and many companies and installations do just that. However the net result is, no matter what the fixture, premature failure! Changing the oil in a car most people do on a regular basis. So with the fixtures, regular maintenance is an excellent practice, if you want the fixtures to last. So what is the maintenance for the fixture? Clean the fan! That s really it! Use a small vacuum cleaner and suck the dust and fur balls out. Do not use a can of co². That will just blast the dust and dirt everywhere! The fan keeps the LEDs cool and keep the electronics cool too. Without the fan working efficiently and dust free, the fixtures will fail and that will be a lot more costly than having someone vacuum the fixtures on a regular basis. How often should the fan be cleaned? It depends on where the fixtures are; in a very dusty atmosphere once a week. So check the fan on a regular basis, it may not need cleaned every week but a quick visual inspection should be done. The front plastic cover for the lenses should be cleaned so the light output is maintained. Use only a moist lint-free cloth. Never use alcohol or solvents to clean the fixture. 19. Technical Specification. Operating voltage 100 250v Frequency 50 60 Hertz 36 x 5 watt leds Fan cooled 305mm x 276mm x 230mm 12" x 10.9" x 9.1" 8.5 kgs 19 pounds Elektralite is a division of Group One. Group One and its divisions are constantly improving their product range and we reserve the right to make changes without prior notice.

Other Products. ElektraLED has other great products that are manufactured under the Elektralite product line. Go check out the website at www.myelektralite.com A preview of the products include:- Elektralite Elektrabar with glare shield for perfect cuts Utilizing homogenized 6-in-1 leds. RGBWAI where the I is indigo (not UV) ; this way perfect pastels like Lee 170 Lavender are flawlessly achieved. The Elektralite 1018 Using 18 high powered 12 watt leds, the Elektralite 1018 is available using 4-in-1 or 6-in-1 leds. Each led can produce any combination of colors as each led is either an RGBW or RGBWAI device

Elektralite ML902 The ML902 utilizes a 120 watt Led and is brighter than a 250 discharge light source. Features include:- Color wheel, two gobo wheels, rotating gobos, rotating 3 facet prism, focus, dimmer, strobe and 16 bit pan and tilt. Elektralite Stingray Ellipsoidal The Elektralite Stingray is a 300 watt LED ellipsoidal with the output of a conventional 750 watt fixture. Different LED types are available including Warm White.

Elektralite SLA The SLA is the perfect compact IP65 fixture for accent lighting everything from trees and walls to product high lighting. Even though it is compact it packs a massive punch with its 15 watt Cree RGBW leds. Elektralite Dazer Downlight The ideal pendant light. Made specifically for the installation market. Can be simply installed by an electrical contractor. 180 watts of power. Comes with 25 degree lenses installed but a lens pack (15,45, & 60) allows you to change the beam angles.