PTS RABKA TRADE AND PRODUCTION COMPANY

Similar documents
SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS-2 HIGH PERFORMANCE OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

Identification - electrical services

3 Locating and Marking Products DOCUMENT OBSOLETE

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS DIELECTRIC HIGH PERFORMANCE OSP TUBE CABLE SERIES

TABLE OF CONTENTS FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES... 4

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX-2 OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

HARMONIZATION OF SYNOPTIC BLOCK DIAGRAMS ON THE CONTROL PANELS OF MV SWITCHGEAR AND CONTROLGEAR

220KV EHV NETWORK AT RELIANCE JAMNAGAR REFINERY COMPLEX

Bharat Heavy Electricals Limited HIGH PRESSURE BOILER PLANT, TIRUCHIRAPPALLI CONTROLS AND INSTRUMENTATION/FB

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTP2-1 PLENUM RATED TUBE CABLE SERIES (NFPA 262) WITH GALVANIZED STEEL INTERLOCKED ARMORING

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX / TOD DIELECTRIC OSP TUBE CABLE SERIES

IndyGo Facility Upgrades Project 35671EE

Field Instruction. Any registered training organisation UETTDRCJ21A Lay ESI electrical cables. Before commencing work:

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

SECTION TESTING, IDENTIFICATION AND ADMINISTRATION

SPECIFICATION 192F SM LOOSE TUBE, DRY CORE MINI CABLE

Our cables at: ATHENS AIRPORT PIRAEUS PORT TUNNEL IN PARIS NATIONAL PETROLEUM OIL COMPANY

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

Dynatel Advanced Cable Locator 2250

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

INSTRUCTION DE SÉCURITÉ SAFETY INSTRUCTION Mandatory as defined in SAPOCO/42 FIRE PREVENTION FOR CABLES, CABLE TRAYS AND CONDUITS

APPLICATION OF POWER SWITCHING FOR ALTERNATIVE LAND CABLE PROTECTION BETWEEN CABLE LANDING STATION AND BEACH MAN HOLE IN SUBMARINE NETWORKS

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

Revision No. 4 Page No. Page 1 of 7

Instrumentation & copper telecom cables

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

Optical Fibre Cable Technical Specification. Duct Cable GYFTY-24,48,72,144,216B1.3

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX TC01TPX (NFPA 262) PLENUM RATED TUBE

DLP200M 2 Relay Module for Heating and Cooling Plants

SPECIFICATION 96F SM LOOSE TUBE, DRY CORE MINI CABLE

ENC - LKE51 - L I B

Tab 10 - The NESC and Underground Applications. Restricted Siemens Industry, Inc All rights reserved.

Medium Voltage 12/20 (24)kV NF C cable system. Xavier Brosse Luanda May 2009

Guide for. Fibre To The Home network constructors

E-VENT. The turnkey plasma cutting machine. Technica l progress in the design

Power cable accessories catalogue

DIAS power supply and DIC 221 fibre optic cable coupling module

2002, Cisco Systems, Inc. All rights reserved.

Mid-Span Access of Loose-Tube Ribbon Fiber Optic Cable

SCHEDA TECNICA. Amarro per cavi 13,5mm Amarro per cavi 16,5mm. MS217F00 Amarro per cavi 13,5mm MS218F00 Amarro per cavi 16,5mm

3M Super 23 Electrical Tape

SECTION 4 TABLE OF CONTENTS

Transmission Cables Overhead/Underground Guidance

Connecting cables NEBS, for sensors

PSC UHF Log Periodic Antenna

PULL SUPPORT PROTECT CONNECT

TECHNICAL SPECIFICATION

Photovoltaic Module Installation Manual (IEC)

ASP-FIBRS1 User Manual

The ideal supplier for industrial, power & electrical installation

Mediacom Upgrade/Splicing Procedures (based on original document from Corporate dated 4/16/98)

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Oxymax W COS61. Technical Information. Dissolved oxygen measurement Optical sensor acc. to the fluorescence quenching principle

Newsletter

Cables for robot applications

HOG 86. The incremental HeavyDuty encoder for highest demands

Metal Theft Taskforce Identification Booklet

Road cables. The foundation for a reliable traffic infrastructure.

Cable Installation Tips

Scotch Heavy Duty Vinyl Electrical Tape 22

Cable Installation Tips

LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56

Connectivity accessories by Nestor Cables

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Sumitomo Cable Specification SE-*RU. OFNP Rated Central Tube Cable with Optical Fibers. Issued: December 2014

Motor Protection Circuit Breaker Series 8146/5-V27

HSME-C400. Data Sheet. Side-Fire Mono-Color Surface-Mount ChipLED. Features. Description. Applications

Operating instructions

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division

SPECIAL SPECIFICATION 6559 Telecommunication Cable

Metal Theft Taskforce Identification Booklet. Version 2

TRF STEP-DOWN TRANSFORMER USER MANUAL

Specification for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D)

L-clickInstallation. Easy Quick Cost-effective

DLP600M 6+1 Relay Module for Heating and Cooling Plants

SPECIAL SPECIFICATION 8540 Telecommunication Cable

CITOCUT Plasma inverter cutting range

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

Quality and Speed of cooking.

CR Signals Price List (N Gauge & General) April 2010

PEM1124ENG ENGLISH. STK TERMINATION KIT FOR PLASTIC CABLE WITHOUT ARMOURING 1 kv STKR TERMINATION KIT FOR PLASTIC CABLE WITH ARMOURING 1 kv

Installation Guide VL-MV10. Model No.

DATA SHEET MS 3780 MS3780_IT_EN_DS050REV01_IS

- Outdoor & Indoor Telephone Cables - Fiber Optic Cables - Electronic Control Cables - Control Cables - Data/LAN Cables - Coaxial Cables

SHARP Plasma inverter cutting range

Level Switch. LS Ex KS Ex RS Ex. Manual. AQ Elteknik AB

JLC-BB150 JLC-BB200 JLC-BB300 JLC-BB500 JLC-BB600 JLC-BB1200

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

SPECIFICATION. Optical Fiber Cable

UC FIBRE Optical Fibre Cable a fast, reliable and always available part of the Draka Datacom Solution. Be ready for the future: Draka Datacom Solution

CHAPTER 14 WIRING SIGNALS AND LIGHTING FIELD GUIDE Wiring Requirements WIRING

ET-5050x-BF1W Datasheet

Emerging Subsea Networks

THE COMPANY QUALITY SYSTEM

INSTRUCTION AND MAINTENANCE VIDEO MOTORE PROJECTION SCREEN

Photovoltaic Module Installation Manual (IEC)

Transcription:

PTS RABKA TRADE AND PRODUCTION COMPANY The PTS Rabka Company is a manufacturer of top quality warning and warning-detection tapes for marking telecommunication, gas, sewage and energy systems. The PTS Rabka Company has been established in 1991. In the year 1992 the Company was the first to start manufacturing tapes with the detection element tape of acid resistant steel - in the Polish market. Considering continuous development requirement as well as meeting customer s expectations the Company opened in the year 1999 a new, modern productionoffice complex in Rokiciny Podhalafskie. Our products meet all required standards, which have been confirmed in the year 2000 by the ISO 9002 and ISO 14001 Quality Certificate. We have certifications and opinions of: Faculty of Electric affiliated to the University of Technology, Szczecin Certificate of Conform ity for warning and warning-detection tapes, Experimental Plant for Communication Building, Warsaw, Oil and Gas Institute of Cracow, Institute of Power Engineering, Warsaw, Centre for Research and Development of Installations and Electric Equipment, Warsaw, and many others Our customers are: Telekomunikacja Polska S.A. (Polish Telecommunication) Polskie Górnictwo Naftowe i Gazownictwo S.A. (Polish Oil and Gas Company) Wodociagi Polskie (Polish Water Supply Plants) Zak?ady Energetyczne (Power Plants) and many manufacturing and trading companies Our company has a network of authorised distributors all over Poland.

MARKING AND DETECTION SYSTEMS Warning tapes, warning detection tapes in the buried utilities marking system. Increasing amount of projects in telecommunication, gas engineering, water supply systems, power industry and other branches causes more concentration of different utilities mainly made of plastics. It brings significant difficulties in detecting relevant cables and pipes. Precise knowledge of the kind and location of key and sore points of the network is necessary for its failure-free work. Using warning and detection tapes along the pipelines and cables as well as additional marking in sore points such as network crossings, junctions at buildings, connections, branching boxes, watercourses, roads etc makes it possible. A layout diagram of the warning and detection tape and example galvanic method of its location is presented in the drawing. Tape for certain network incorporation in the works should have the colour to conform to the standard (the colour must correspond with the network). The tape may have an inscription usually in black, also to conform to conditions in force (example: ATTENTION! OPTOTELECOMMUNICATION CABLE, ATTENTION! WA- TER MAINS, GAS, and others). The PTS Rabka Company created a marking system using warning and warning - detection tapes. Advantages of the marking and detection marking system: early warning on possible mechanical damage of network during works; role of the detection factor possibility of precise detection of the route and depth of the pipeline (installation); EMS markers possibility of detecting sore points and crossings with other network. EMS marker (table of types catalogue symbols) UNDER SURFACE BALL-VALVE MINI- UNIVERSAL FREQUENCY [khz] Maximum depth 60 cm 150 cm 180 cm 240 cm GAS (yellow) 1436 1405 1259 1254 83,0 TELEPHONE (orange) 1432 1401 1255 1250 101,4 WATER (blue) 1434 1403 1257 1252 145,7 SEWAGE SYSTEM (green) 1435 1404 1258 1253 121,6 POWER (red) 1433 1402 1256 1251 169,8 CATV (black-orange) 1407 74,0 Example pipeline marking END EMS Warning tape with printed inscription WARNING! OPTOTELECOMMUNICATION CABLE Warning - location tape with acid-proof steel insert Telecommunications electromagnetic marker Water supply electromagnetic marker Warning tape (TO-G) Optical fibre cable in protecting tube laying a layer of 15 cm of soil before covering up the marker horizontal positioning maximum depth = 1,8 m minimmum distance of 10 cm from the marked point Optical fibre cable Sewerage Warning - location tape with perforation (TOL-G) Plastic gas pipe Branching

TELECOMMUNICATION TAPES for the Telecommunication are in the colour orange and have an inscription: ATTENTION OPTOTELE- COMMUNICATION CABLE OR ATTENTION TELECOMMUNICA- TION CABLE. Production is based on top quality raw materials, which provide high durability and mechanical strength as well as tapes resistivity to the aggressive soil factors influence. Applying the insert made of the acid resistant steel in tapes for fibre optic cable marking provides easy and reliable detection of the route. Tapes have necessary opinions and certificates required for materials applied for telecommunication lines construction. TAPE DESCRIPTION INDEX WIDTH INSCRIPTION TO-Tkt/10 10 cm Orange TO-Tkt/15 15 cm TO-Tkt/20 20 cm TO-Tkt/25 25 cm TO-Opt/10 10 cm For fibre optic cables without steel insert TO-Opt/15 15 cm TO-Opt/25 25 cm TOL-Opt/10 10 cm For fibre optic cables with steel insert TOL-Opt/20 20 cm TOL-Opt/25 25 cm Orange with steel insert TOL-6/z 6 cm ATTENTION, TELECOMMUNICATION CABLE ATTENTION OPTOTELECOMMUNICATION CABLE ATTENTION OPTOTELECOMMUNICATION CABLE LOCATION OF S LOCATION OF LOCATION TAPE MARKING-MEASURING POST CONNECTION OF SIGNAL GENERATOR TO CONTROL -MEASURING POST ELECTROMAGNETIC MUNICIPAL POST LOCATION TAPE WARNING TAPE OPTICAL FIBRE CABLE IN PROTECTING TUBE CABLE BOX CABLE STORAGE BIN telecommunication network location and Marking system

GAS Tapes for marking gas grids by applying steel insert similar as in the case of tapes for telecommunication network provide easy and reliable detection. Yellow, clear colour of the tapes assures identification in case of digging it out by an excavator and therefore avoiding damage to the gas grid. For the sake of safety assurance the tape is perforated lengthwise which protects from liquids and gas accumulation. Both tapes for marking gas grids and telecommunication network have inscription on the tape lengthwise, which allows easy and quick identification of the network. Marking system in conformance with ZN G 3001: 2001 standard involves application of sets of two tapes: Warning tape Detection tape (with acid resistant insert) TAPE DESCRIPTION INDEX WIDTH INSCRIPTION TO-G/20 20 cm Yellow, perforated TO-G/30 30 cm TO-G/40 40 cm TO-Gn/20 20 cm Yellow, plain with inscription TO-Gn/30 30 cm GAS TO-Gn/40 40 cm TO-G1/20 20 cm Yellow, perforated with steel insert TO-G1/30 30 cm TO-G1/40 40 cm TO-Gn1/20 20 cm Yellow, perforated with steel insert TO-Gn1/30 30 cm GAS TO-Gn1/40 40 cm Yellow, plain with steel insert TOL-6/z 6 cm LOCATION OF LOCATION TAPE LOCATION OF S MARKING-MEASURING POST CONNECTION OF SIGNAL GENERATOR TO CONTROL- MEASURING POST ELECTROMAGNETIC MUNICIPAL POST LOCATION TAPE ELECTROMAGNETIC WATER SUPPLY SYSTEM WARNING TAPE GAS network location and Marking system

POWER ENGINEERING Marking the underground power networks with warning tapes is of a great importance especially for the reason of great danger to human lives in case of cables damage. Tapes for underground power systems marking are manufactured in two colours: BLUE for cables of voltage rating below 1 kv, RED for cables of voltage rating over 1 kv. Colouring and thickness of tapes applied for marking power networks conform to standards relevant to voltage rating of the network. Raw materials and materials used for such tapes production provide top quality and resi-stance. TAPE DESCRIPTION INDEX WIDTH THICKNESS INSCRIPTION Marking tape for electrical power engineering cables of voltage rating of 1 kv and below blue red TO-ENN/08/20 20 cm 0,08 mm ATTENTION CABLE TO-ENN/12/20 20 cm 0,12 mm ATTENTION CABLE TO-ENN/16/20 20 cm 0,16 mm ATTENTION CABLE TO-ENN/40/20 20 cm 0,40 mm ATTENTION CABLE TO-ENN/45/20 20 cm 0,45 mm ATTENTION CABLE Marking tape for electrical power engineeing cables of rating voltage over 1 kv TO-ENN/08/20 20 cm 0,08 mm ATTENTION CABLE TO-ENN/12/20 20 cm 0,12 mm ATTENTION CABLE TO-ENN/16/20 20 cm 0,16 mm ATTENTION CABLE TO-ENN/40/20 20 cm 0,40 mm ATTENTION CABLE LOCATION OF S LOCATION OF CABLE ELECTROMAGNETIC CABLE BOX WARNING TAPE POWER CABLE IN PROTECTING TUBE CABLE STORAGE BIN POWER ENGINEERING network location and Marking system

AND THERMAL POWER ENGINEERING The big concentration of water supply systems especially in urban areas makes the problem of marking its routes special significance. Warning tapes and warning - detection tapes used for water supply systems marking may be a solution here. It gives the possibility of early warning about the water supply system and therefore protect from water pipes damage. Application of acid resistant steel insert provides easy detection of the network. This solution may also be utilised for sewage and drainage systems. Similar to the water supply systems, marking of the thermal power engineering also becomes of special importance in urban areas. In case of accidental damage of networks protection we use warning and warning-detection tapes for thermal power engineering in the colour of green-white. Easy network detection is achieved by using tapes with steel insert. TAPE DESCRIPTION INDEKS WIDTH TYP INSCRIPTION TO-W/20 20 cm Blue TO-Wn/20 20 cm ATTENTION WATER SUPPLY PIPELINE TOL-W/20 20 cm With steel insert TOL-Wn/20 20 cm With steel insert ATTENTION WATER SUPPLY PIPELINE Blue with steel insert TOL-6 6 cm glued TOL-6z 20 cm bonded Blue/White TO-Wbn/20 20 cm TOL-Wbn/20 20 cm With steel insert Green TO-Z/20 20 cm TOL-Z/20 20 cm With steel insert Green/White TO-EC/20 20 cm TOL-EC/20 20 cm With steel insert LOCATION OF S LOCATION OF LOCATION TAPE ELECTROMAGNETIC MARKING-MEASURING POST CONNECTION OF SIGNAL GENERATOR TO CONTROL- MEASURING POST MUNICIPAL POST WATER SUPPLY SYSTEM SEWERAGE WATER SUPPLY network location and Marking system