General Wiring and Installation Guidelines. Typical Mounting Installations Electrical Connections General Guidelines Common Questions & Answers

Similar documents
ELECTRICAL. DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from shaft end) TERMINAL CONNECTIONS COM VCC CASE

DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from clamp end)

EZ Encoder : Optical Incremental

Installation and Wiring Guide

ENC-MC58SN-L R-L1

Product Manual MNX10015 / REV C MODEL SB142, SB242. Dual Output Series Switch Boxes

Installation and Wiring Guide

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

Speed sensor MiniCoder GEL 2471

ENC-CK58SN-L R-L1

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

EM1. Transmissive Optical Encoder Module Page 1 of 8. Description. Features

NexGen SERIES 22 QUBE Encoder

Photoelectrics Through-beam Type PA18C.T..., DC

Considerations for Specifying, Installing and Interfacing Rotary Incremental Optical Encoders

EZ Encoder : Optical Incremental (P Series)

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

Material: Weight: IP Rating: Cable: Connector:

Incremental Hollow Shaft Encoder

SQM40/41 Actuators for air and gas dampers

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA

2100/2200/4100/6200 & MPB Series Bottom Mount Drive Pack. for Standard Load Parallel Shaft 60 Hz Gearmotors

2100, 2200, 4100, 6200, MPB Series Side Mount Drive Package for Light Load 60 Hz Gearmotors

SE22HR Small Encoder High Resolution 5V optical encoder up to 2048 CPR

Dial Ezy INSTRUCTION MANUAL N IRRIGATION CONTROLLER 4 or 6 Station Model SUITABLE FOR INDOOR USE ONLY OTHERWISE WARRANTY IS VOID

Installation and Wiring Guide

AWT150C/AWT150CS/ AWT151C CCD Camera

NewScope-7A Operating Manual

Step 1. 2x Kep Nut 1x Left Motor Assembly

2000 Series Weather Stations Analog Temperature / RH Sensor Upgrade Kit PRODUCT MANUAL KIT # 3613WDU

EM1. Transmissive Optical Encoder Module Page 1 of 9. Description. Features

Contactless Encoder IO-Link Ri360P0-QR24M0-IOLX2-H1141

Incremental Hollow Shaft Encoder

OWNER'S MANUAL SIGNAL COMMANDER

Field Service Procedure Replacement PCU Kit, Coastal

In-Ceiling Electric Motorized Front Projection Screen Evanesce Series. User s Guide

FIST-GCOG2-Dx6. Follow all local safety regulations related to optical fiber plant elements.

Field Service Procedure Replacement GACP Control Panel Kit, ST24

INSTALLATION INSTRUCTIONS FOR

HD Flex Patch Panel. ASSEMBLY VIEW (FLEX1UPN** shown) FS128B. CONTENTS: (#) indicates FLEX4UPN** quantity

TECHNICAL GUIDE. TOUGH GUN ThruArm G1 Series Robotic MIG Guns for FANUC Robots 100iC, 100iC-12, 100iC-6L, 100iC-7L, 120iC, 120iC-10L, 120iC-12L

Type SCH94FO. Type SCH94FO. Description

Power Injector 1520 Series

FP-QUAD-510. Features. Power Requirement OPERATING INSTRUCTIONS. 4-Axis, Quadrature Input Module

FX-4AD-TC SPECIAL FUNCTION BLOCK USER'S GUIDE

Smart-Encoder : Optical Incremental

EM1. Transmissive Optical Encoder Module Page 1 of 8. Description. Features

AUTOMATIC VIDEO LOSS A/B SWITCH

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

INSTALLATION INSTRUCTIONS FOR. MODEL 2230LED

Accessories. Servo Motors. Servo Motors B-45. Accessories

Contactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181

MOTION CONTROL SYSTEMS, MSC SERIES AUGUST 1998 EFC-240X ENCODER/FIBER OPTIC CONVERTER INSTRUCTION BOOK

TeamWork Kits Installation Guide

LED Driver Linear / area fixed output

Industrial Monitor Update Kit

AMERICAN NATIONAL STANDARD

Model /29S RF Splitter

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

Circulating Feed Delivery System Installation Instructions for Model 55, 75, 90, & HMC FLEX-AUGER Feed Delivery Systems

Satellite Dish Installation Manual (Ver. 2) 1

Contactless Encoder Analog RI360P0-QR24M0-ELIU5X2-H1151

03-Durchfuehren_RZ_0708_EN.qxd:03-Durchfuehren GB.qxd :06 Uhr Seite 200 Feed-through

WC-2100 WORD CLOCK DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL

3 SLiC Aerial Closure with Rubber End Seal

Absolute Encoders Multiturn

Vibratory Deck Sieves 15 in. (380 mm)

Index. Index. 1.0 Introduction...2 This Manual Operation Finger Lift Cable Lift Pneumatic Operation...

WDK-2500-STROBE. User Guide

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

Quick Release Roof-Mount Kit MB700

DLM471S-5.1 MULTICHANNEL AUDIO LEVEL MASTER OPERATION MANUAL IB B. (Mounted in RMS400 Rack Mount & Power Supply) (One of 4 Typical Cards)

Accessories. Servo Motors. Servo Motors B-47. Accessories

VHF + UHF Amplified HDTV Antenna Model OA8000 & OA8001 Installation Instructions Reception Frequencies

Troubleshooting Guide 9630 Series

TAC1 Telephone Entry System

Sigma 1 - Axis Servo Motor and Cables - Troubleshooting Guide

OWNER'S MANUAL SIGNAL COMMANDER

Installation Manual SaVi Note Underwater LED Light

Contactless encoder RI360P0-QR24M0-INCRX2-H1181

Up to 85% higher Service Life due to efficient sealing method.

Automatic Connector MHV Connectors MHV Introduction MHV series connectors Contents Polarized mating interfaces Anti-Rock mating interfaces

HN Connectors. Automatic Connector. Introduction. Contents. 631/ FAX 631/

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

AS09..S 3-pole Contactors - Spring Terminals

AUDIO ROOF KIT P/N , , APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Instr Rev Page 1 of 6

Scale Track System. 21 Century y Signal System 2-Rail Manual

INSTALLATION INSTRUCTIONS MODEL VSBX-236 LED 3 X 8 INDOOR SCOREBOARD

Heidenhain Feedback Option Card for PowerFlex 700S Phase II Drives

Proper Installation of SCR s will Extend Life Author - George A. Sites, AMETEK HDR Power Systems

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Commissioning Guide. firepickdelta. Commissioning Guide. Written By: Neil Jansen firepickdelta.dozuki.com Page 1 of 22

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

Circulating Feed Delivery System Installation Instructions for Model 55, 75, 90, & HMC FLEX-AUGER Feed Delivery Systems

GAP SUPER C ANTENNA. Installation and Assembly Instructions. GAP Antenna Products, Inc. 99 North Willow St Fellsmere, FL (561)

Materials: Programming Objectives:

Absolute Rotary Encoder E6CP

Transcription:

General Wiring and Installation Guidelines Typical Mounting Installations Electrical Connections General Guidelines Common Questions & Answers

Congratulations on your purchase of a Dynapar brand encoder. All Dynapar brand encoders are 100% final tested and have a full one-year warranty against defects in material and workmanship. This booklet is provided to you as a guideline for the installation of your new encoder. TYPICAL MOUNTING INSTALLATIONS Dynapar brand encoders feature industry standard mounting configurations and mounting bracket accessories to help simplify installation. Shaft Encoders Shaft encoders are typically servo, flange, face, or foot mounted. MOUNTING CLIPS (3) PANEL SERVO MOUNT FACE MOUNT FOOT MOUNT FLANGE MOUNT Because shaft encoders have no flexture, mechanically coupling one to a machine requires important consideration. Backlash or modulation in the coupling can cause errors in position indication. Rigid attachment of the shaft may cause bearing failure. Therefore, a flexible coupling, which compensates for misalignment between the encoder shaft and the machine, must be used. 1

Flexible Couplings - Encoder shafts and bearings are designed to require very restricted axial and radial play. When shafts are coupled, excessive shaft loading, electrical leakage, and thermal stress can cause encoder failures. Therefore, a flexible coupling (Dynapar brand CPL Series) which provides maximum mechanical, thermal, and electrical protection for encoder shaft connections, should be used to ensure long encoder life. The CPL Series provides a full range of flexible coupling models designed to match specific encoders. Each is supplied with input-shaft size adapters. When selecting a flexible shaft coupling, there are four major criteria which must be considered: 1. Encoder Application (light duty to extra heavy duty) 2. Encoder Shaft Size 3. Drive Shaft Size 4. Endplay of Shaft Most applications use the Primary Bore as the encoder end; however, it is permissible to reverse the coupling to provide for specific shaft accommodations. Secondary bore inserts are supplied. There are also dimensional options available - D=Diameter (0.75 to 2.0 ), L=Length (0.875 to 2.0 ), and G=Grip (0.23 to 0.45 ). G L D Primary Bore Insert Secondary Bore Attachment of a flexible coupling at both ends is via integral 360 clamps which firmly grip the encoder shaft and the input shaft while remaining slip-free to the rated torque of the coupling. NOTE: Shafts may extend beyond the clamp-grip area (G) to the flexture area but they must not butt. 2

Direct Mounted Encoders There are encoders which do not have shafts and are mounted directly onto machine or motor shafts. Examples include hub shaft or hollowshaft models with integral flexible mounts and ring kits which include separately mounted rings and gears. Since coupling between encoder and machine or motor shafts does not occur, flexible shaft couplings are not required. In addition, there may be no need for mounting brackets or adapters. HOLLOWSHAFT ENCODER RING MOUNT ENCODER GEAR REDUCER MOTOR HUB SHAFT OR HOLLOWSHAFT MOUNT 56C MACHINE RING MOUNT A hub shaft or hollowshaft encoder should be mounted so that its shaft receptacle is in as close as possible alignment with the axis of the driving machine or motor shaft. Clamp or set screws should then be tightened to secure the encoder. NOTE: Do not defeat or restrict the flexure. This causes failure of the encoder or driving shaft bearings. A ring kit encoder should be mounted so that its mounting holes are in exact alignment with the holes or studs on the motor frame. All fasteners should then be firmly tightened with equal torque so as not to distort the shape of the ring. The gear is then positioned on the motor so that it is centered relative to the sensor. NOTE: Check the rotation of the motor shaft and gear to determine that the specified gap between the gear teeth and sensor is properly maintained. 3

ELECTRICAL CONNECTIONS Cable - The use of shielded cable is recommended for all encoder installations. When a Dynapar brand encoder is ordered, the type of termination is generally defined (usually the last selectable code in Ordering Information). If a code for a cable was indicated, the encoder was manufactured to include a shielded cable. If any other type of termination was selected or if selection of termination type was not requested, a cable assembly must be ordered. (The cable assembly easily hooks onto the encoder s connector making it ready for wiring.) To determine which cable assembly to order, refer to the Electrical Connections table (in the encoder s technical bulletin). In some cases, there may be more than one table or the table may be broken into sections due to different output types. If so, refer to the information listed for the output type selected for the encoder (in Ordering Information). Wiring should be run through dedicated conduits or harnesses (not shared with any other wiring) which are spaced at least 12 inches apart. This protects the cable from physical damage while providing a degree of electrical isolation. Also, do not run cable in close proximity to other conductors which carry current to heavy loads such as motors, motor starters, contactors, or solenoids. Doing so could result in electrical transients in the encoder cable which cause undesired signal pulses. NOTE: Never connect or disconnect the encoder connector or wiring while power is ON. Doing so may damage the encoder. 4

Grounding - DO NOT ground the encoder through both the machine and the cable wiring. Connect the shield at the input device only. NOTE: If the shield is connected at both ends, grounding problems that degrade system performance will result. For European-based applications requiring CE-compliance, cable length must not exceed 30m. Connect common to building ground and connect the shield to building ground on both ends. CE-compliant products are tested to EN61326 EMC. Features - All encoders have the following electrical features: Power (+DC) Common Output Signal(s) Power (also referred to as supply, power source, and power +V/VCC) is always +DC for encoders. Therefore, power should always be connected to the positive (+) side of DC power. In addition, encoder power should be regulated to within ±5% at the encoder and should be free of induced transients. Common (also referred to as Com, supply common, and ground) is generally a black wire (verify via Electrical Connections table). Common should always be connected to the negative (-) side of DC power. All encoders have at least one output signal (A); however, it is common for encoders to have three signals (A, B, and Z {Z may also be referred to as C, X, or index}). The outputs should each be connected to the receiving device at the appropriate terminal. NOTE: Never connect A, B, or Z to the + or - side of DC power. When encoders have a differential line driver, there are two signals for each of the outputs. Each signal (A, B, 5

and Z) has a compliment or inverse (A, B, and Z - referred to as A not, B not, and Z not). The signal and its compliment (i.e. A and A) are separate outputs. Connection of the outputs is the same as for single signals per output. NOTE: Never connect these signals together or to the + or - side of DC power. Connections - Obviously not all receiving devices are the same. However, connecting your encoder to one, no matter what type or brand it may be, is not difficult. As discussed in the previous section, all encoders have certain electrical features. Each of these features/functions is identified in the encoder s Electrical Connections table along with its corresponding pin and wire color. Each wire specified in the table must be connected to the receiving device. Determining where to connect each wire is as easy as following the Electrical Connections table and matching each wire to the proper terminal on the receiving device. In general, no matter what type of receiving device you are using, the terminal strip is marked, indicating the proper location for each function/wire. These markings may either be numbers (such as on the illustrations on page 7) or text labels identifying functions. If they are numbers, the receiving device s manual should define what function corresponds to each number. Since receiving devices are made by various manufacturers, not all text labels are the same. There are various ways to identify each function. Following are a few examples: 6

Power = DC Power Supply + = +12VDC Common = DC Power Supply - = COMM A = Input A = A+ = Term A A = A- = A Not Z = C = Index = Marker The receiving device will have one of two types of connection methods: 1 2 3 4 Each wire is inserted into the appropriate opening. The corresponding screws (located on the side of the terminal block) are then turned to tighten the clamps and secure the wires. OR 16 17 18 19 The screws are loosened, and each wire is wrapped around the appropriate screw. The screws are then turned to secure the wires. 7

GENERAL GUIDELINES Encoders provide quality measurements and long life when common sense, care, and accurate alignments are provided during installation. The following general guidelines will help to ensure a trouble-free installation. Mounting the Encoder Do not shock the encoder. Do not subject the encoder to axial or radial shaft stresses. Do not disassemble the encoder. Do not use a rigid coupling. Do not tool the encoder or its shaft. Do not use makeshift techniques to mount the encoder. Wiring the Encoder Never connect or disconnect the encoder connector or wiring while power is ON. Doing so may damage the encoder. Power should always be connected to the + side of DC power. Common should always be connected to the - side of DC power. Never connect A, B, or Z to the + or - side of DC power. 8

COMMON QUESTIONS & ANSWERS There are additional colored wires which are not referred to in the Electrical Specifications table. What do I do with them? Do not connect them to the receiving device. Any unused encoder signal wires must be individually insulated and tied back. They should NEVER be in contact with common, power sources, or other output signal lines. The encoder is correctly connected to the receiving device per the Electrical Specifications table and the receiving device s terminal strip label; however, it s counting in the wrong direction. What s wrong? In order to reverse the counting direction, the output signal connections must be switched. Simply flip-flop the connections for signals A and B. However, if the encoder has a differential line driver, one signal and its compliment must be reversed (flip-flop the connections for A and A). I ve connected the encoder and it doesn t work (No Outputs). What can I do? Hxxx Series encoders have internal protection circuits which shut down the encoder to prevent damage if the input power is not correct or the outputs are overloaded. Check the following: Input Voltage (is it too high?); Input Polarity (is it reversed?); and Output Wiring (are they wired properly?). For all other series encoders, check power and output wiring. I ve read and followed the technical manual and these guidelines and the encoder still doesn t work properly. Help!? Calm down - help is at your fingertips! Simply pick up the phone and dial our Applications Engineering Department at 1-800-234-8731 (US & Canada) or 847-662-2666 from 8:00 AM to 4:45 PM (Central time) Monday - Friday. One of our engineers will gladly walk through the problem with you and help determine a solution. 9

1675 Delany Road Gurnee, IL 60031-1282 Phone: 847.662.2666 Fax: 847.662.6633 E-mail: dancon@dancon.com 702111-0001 Rev. D November 2, 2007