ALLEN BRADLEY TIMING RELAY

Similar documents
Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Magnecraft Power Relays

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

02/11/2015

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

Series CT7N Bimetallic Overload Relays

Solid-State Digital Timer

Bulletin 190 IEC Modular Starter System

AS09..S 3-pole Contactors - Spring Terminals

llen-bradley 194R-HM4-NFPA3

A V 50Hz / V 60Hz

Type Contact form Model

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

Magnecraft Power Relays. Catalog

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

-V- New. Connecting cables for valves, socket type B, industry standard Type codes Connecting cable with PUR cable sheath NEBV B2 W 3 F P K 0.

MILLITARY SPECIFICATION SHEET

relays Electromechanical 2006 /2007

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Bulletin 109 TABLE OF CONTENTS Bulletin 109 IEC Non-Reversing Starters. Enclosed Type Molded Plastic. Description Page Description Page

Single Point Flow Monitor SW118 SW119

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

Connecting cables for valves, socket type A, EN Type codes Connecting cable with PUR cable sheath

Minicontactorrelay,2NO/2NC,DCoperated

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Manual Motor Starter Specifcations

Magnetic and Hydraulic-Magnetic Circuit Breaker

Bulletin 305 AC Starters

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

ORDERING Page 6 STANDARDS, DIMENSIONS and ACCESSORIES Request bulletin SDA

Series CDP2 Definite Purpose Contactors

Pluggable interface relays CR-M Miniature relays

Movable Contacts Heavy duty silver cadmium oxide composition to resist welding and contact erosion for greater reliability

High performance circuit breakers

Interface Relays and Optocouplers Product group picture

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

1.1. Contactors and Starters... Contents Description Relays and Timers Catalog Number Selection... Product Selection...

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

TE s AGASTAT relays are available in two basic operating types: On-Delay and Off-Delay.

AC1036. Definite Purpose Contactors

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Series CDP2 Definite Purpose Contactors

Assembly. Front view. LEDs. Parametrization interface. Power Bus

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

Bulletin 100-G IEC Contactors

Process transmitter RMA422

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

Nessie Coils for VDH and VDHT valves

Agency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Your order must include: cat. no. of the miniature contactor specified with coil voltage code and, if required, cat. no. of any accessories

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1)

Modular Lube Lubrication Systems System Controls

M-relays, 2, 3 or 4 pole, 7-12 A Datasheet

Definite Purpose Contactors

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Type: DILM25 10(24V50HZ) Article No.:

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

Process Transmitter RMA 422

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

Type: DILM12 10(24VDC) Article No.:

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure

Pluggable interface relays CR-M Miniature relays

Model Number Structure

Level Measurement silometer FMC 420, FMC 423

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Model Number Structure. Ordering Information

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

GV2P05. Main. Device short name. Device application

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

Bulletin 100-G IEC Contactors

MAP110 AC-DC Series Data Sheet

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

Digital output modules

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

02/11/2015

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

Modular pulse operated latching relay 16 A

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Transcription:

ALLEN BRADLEY TIMING RELAY Configuration Details Product: 700-HS12BA1 Description: 700-HS General Purpose Square Base Timing Relay, On Delay Timer, 1.0 to 180 seconds, DPDT, 120V AC 50/60Hz CONTROL RELAY DATA: Timing Fixed Mode Timing Mode Contact Configuration Timing Range Coil Voltage Adjustable Timer On Delay Timer DPDT Contact Arrangement 1.0 to 180 seconds 120V AC 50/60Hz CERTIFICATIONS AND APPROVALS: UR CSA CE Bulletin 700-HS Timing Relay (On-Delay or Off-Delay) Rugged Blade Style Quick Connect Socket Mounting 12 A, DPDT Contact Rating 0.1 s 180 s Range Available As a Single Range or Fixed Timing (0.1 s 600 s)

PRODUCT SELECTION: Single Range Timing Relay with Blade Style Quick Connect/Solder Terminations Operating Mode On-Delay Wiring Diagrams U.S./Canada International Socket Off-Delay 700-HN154 or Bulletin 700-HS DPDT 2-Pole 2 Form C Contacts Socket 700-HN154 or 700 HS 2 2 A A1 a b c d e a Timer Type HS Square Base Adjustable Timing Relay b Mode Type Code Mode 1 On-Delay 2 Off-Delay

c Number of Poles 2 2PDT d Timing Range Code Adjustable Time Type HS A 0.1 10 s B 1.0 100 s C 0.1 10 min D 1.0 100 min E 0.1 10 hr e Coil Voltage Code Volts U12 12V AC/DC, 50/60 Hz U24 24V AC/DC, 50/60 Hz U120 120V AC/DC, 50/60 Hz Fixed Timing Relays Description Bulletin 700-HSF fixed timing relays feature a plug-in square base with blade style terminations. Construction is the same as the Bulletin 700-HS timing relay except that the adjustment knob has been removed to help prevent unwanted tampering. The timing and output specifications are identical to those of the Bulletin 700-HS timing relay. Setting will be ±5% of the time ordered. Socket: Cat. No. or 700-HN154 Bulletin 700- HSF DPDT 2 Pole 2 Form C Contacts 700 HSF 2 2 025 S U24 a b c d e f a Timer Type HSF Square Base Fixed Timing Relay b Mode Type Code Mode 1 On-Delay 2 Off-Delay

c Number of Poles 2 2PDT d Timing Value Code Value 001 999 The three digit code represents a numeric value with one decimal place. For example: code 001 is 0.1, code 025 is 2.5, and code 999 is 99.9 The acceptable range for each time unit is listed below: Seconds - 001 999 Minutes - 001 999 Hours - 001 100 e Timing Units Code Units S Seconds M Minutes H Hours f Coil Voltage Code Volts U12 12V AC/DC, 50/60 Hz U24 24V AC/DC, 50/60 Hz U120 120V AC/DC, 50/60 Hz Use both the Timing Value and Timing Units tables to properly select the desired fixed time relay. For example: 700-HSF22025SU24 selects a timer value of 2.5 seconds and 700-HSF22025MU24 selects a timer value of 2.5 minutes.

Accessories Cat. No. Description Screw Terminal Socket Panel or DIN Rail Mounting. Guarded Terminal Construction 11-blade socket for use with Bulletin 700-HB and -HJ relays and -HS timing relays. Order must be for 10 sockets or multiples of 10. Safe separation between coil and contacts. Screw Terminal Base Socket Panel or DIN Rail Mounting. Open Style Construction 11-blade for use with Bulletin 700-HB and -HJ relays and -HS timing relays. Order must be for 10 sockets or multiples of 10. Pkg. Cat. No. Qty. 10 10 700-HN154 Cat. No. 700-HN154 DIN (#3) Symmetrical Rail 35 mm x 7.5 mm x 1 m long Zinc-plated, yellow chromated 10 199-DR1 Cat. No. 199-DR1 Retainer Clip for Cat. Nos. and -HN154 Sockets with Bulletin 700-HS Timing Relays Secures relay in socket. Order must be for 10 clips or multiples of 10. 10 700-HN160 Sample Retainer Clips Pre-printed identification tags contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets of the markings CR 9CR, TR 9TR, M 9M, F, R, 1S, and 117 blank tags. Tags are peel-off with sticky backing for easy placement on relays. Blank identification tags contains 10 sheets of blank identification tags for customer specialized printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on relays. 10 700-N40 10 700-N41 Bulletin 700-HS Timing Relay, Socket, and Retainer Clip Reference Chart Relay Type Socket 700-HS 700-HN154 Retainer Clip 700-HN160

Specifications Electrical Ratings Pilot Duty Rating Rated Thermal Current (I th) Rated Insulation Voltage (U i) Contacts Cat. No. 700- HS Cat. No. 700-HSF NEMA B300 12 A 250V IEC, 300V UL/CSA Inductive Make Break Hp Make Break Hp 120V AC 30 A 3 A 1/3 30 A 3 A 1/3 240V AC 15 A 1.5 A 1/2 15 A 1.5 A 1/2 Resistive 30V DC 12 A 12 A 12 A 12 A Permissible Coil Voltage Variation 85 110% of Nominal Voltage at 50 Hz 85 110% of Nominal Voltage at 60 Hz 80 110% of Nominal Voltage at DC Power Consumption AC 24V AC 2 VA ±10% 120V AC 3 VA 240V AC DC 1.3 W Design Specification/Test Requirements Dielectric Withstand Pole-to-Pole, same circuit (VRMS) 1000V AC Voltage Pole-to-Pole, different circuits 2000V AC (VRMS) Contact-to-Coil (VRMS) 2000V AC Electrical Life Operations 100,000 minimum Switching Frequency Operations 360/hr Coil Voltages See product selection Mechanical Degree of Protection Open Type (Guarded Terminal Sockets) Mechanical Life Operations 10 x 10 6 Switching Frequency Operations 18,000/hr Timing Duty Cycle Continuous Repeat Accuracy ±2% (Time Delay: 0.1 2 s) (constant voltage and temperature) ±1% (Time Delay: >2 s) Repeat Accuracy (variable voltage and temperature) Fixed Time Setting Accuracy ±2% (Time Delay: 0.1 2 s) ±1% (Time Delay: >2 s) Scale High End of Range +5% Tolerance Low End of Range 50% Reset Time ON Delay 100 ms OFF Delay 40 ms Environmental Temperature Operating 28 +65 C ( 18 +149 F) Storage 55 +85 C ( 67 +185 F) Altitude 2000 m (6560 ft) ±15%

SPECIFICATIONS CONTINUED: Construction Insulating Material Enclosure Contact Material Terminal Markings on Socket Sockets Molded High Dielectric Material Impact Resistant Dust Cover Silver Nickel In accordance with EN 50 005 8- or 11-Blade (On = 8, Off = 11) -HN154 Certifications CSA Certified, File LR1234, UL Recognized, File E3125 Guide NLDX 2, Listed Ind. Cont. Eq. and 700-HN154 sockets, CE Marked (per EU Low Voltage Directive 93/68 EEC) Standards EN 61812, EN 60947-5-1, CSA 22.2, UL 508 Performance Data See Important 2, publication A115. NEMA Rating Chart is on page 19 of publication 700-SG003B-EN-P.