UFX-EbNo Series Precision Generators

Similar documents
Noise Detector ND-1 Operating Manual

Inmarsat Downconverter Narrowband Downconverter

High-Value 100 Series (Outdoor)

R-1580A Microwave Downconverter. Product Brochure

Test Systems. Typical JFW Systems. Matrix switches Programmable assemblies Switch assemblies Manual attenuator assemblies Power divider assemblies

R3267/3273 Spectrum Analyzers

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

SYNTHESIZED COMMUNICATION CONVERTERS

L-Band Block Upconverter

Converters Series Tri-Band Frequency Converters. Back to Multiband. Specifications Upconverters Downconverters Phase Noise Options Rear Panel

MULTIBAND 1/3 RACK-MOUNTED

Synthesized Block Up- and Downconverter Indoor / Outdoor

8500A. Advanced Test Equipment Rentals ATEC (2832) channel capability. For tests on pulse mod- SERIES PEAK POWER METERS

HP 71910A and 71910P Wide Bandwidth Receiver Technical Specifications

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

Satellite Up- and Downconverter Indoor / Outdoor

MODEL OTM-4870 FREQUENCY AGILE 870MHz F.C.C. COMPATIBLE TELEVISION MODULATOR

Advanced Test Equipment Rentals ATEC (2832)

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

1/3 RACK-MOUNTED BLOCK CONVERTERS

EX04-000D. DVB-T/2xT/T2 MODULATOR DVB MODULATOR

INTEGRATED ASSEMBLIES MICROWAVE SOLUTIONS FROM TELEDYNE COUGAR

Modular Block Converter Systems

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System

L-Band Block Up- and Downconverter Indoor / Outdoor

18 GHz, 2.2 kw KLYSTRON GENERATOR GKP 24KP 18GHz WR62 3x400V

1:1 and 1:2 Redundant Low-Noise Ka-Band Block Converter Systems

FREQUENCY CONVERTER. MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS. Narda-MITEQ FEATURES OPTIONS

Technical Datasheet. 8650B Series Universal Power Meters 10 MHz to 50 GHz. 8651B Single Channel 8652B Dual Channel Rev.

Satellite Up- and Downconverter

FREQUENCY CONVERTER. MULTIPLE WIDEBAND Ku AND Ka UPCONVERTERS. Narda-MITEQ FEATURES OPTIONS

1Chapter INTRODUCTION. This chapter describes the CST-5000 C-Band satellite terminal, referred to in this manual as the CST-5000 (Figure 1-1).

High Performance Outdoor Test Translators

DA E: Series of Narrowband or Wideband Distribution Amplifiers

DVO700 P FIBRE OPTIC TRANSMITTER

Calibrating attenuators using the 9640A RF Reference

Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X

Microwave Counter, Power Meter and DVM in One Portable Package

NS-3 RF Noise Source Operation Manual

SIR MICROWAVE WIDEBAND DSP RECEIVERS UP TO 26.5 GHz. WIDE FREQUENCY RANGE: GHz

8650A SERIES UNIVERSAL POWER METERS

VM-100R. 1 RU HEIGHT PROGRAMMABLE 70 AND 140 MHz HIGH-PERFORMANCE VIDEO/AUDIO MODULATOR

Ka-Band Outdoor Block Upconverters and Low-Noise Block Downconverters

Synthesized Block Up- and Downconverter

LadyBug Technologies, LLC LB5908A True-RMS Power Sensor

Typical applications:

2 MHz Lock-In Amplifier

MTP200B WLAN / BT LE Tester

LSA Series. Signal Analyzer. Any signal, Any time, Any place

SIDC-6005 MICROWAVE WIDEBAND DOWNCONVERTER / TUNER UP TO

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Product Catalogue January 2018

SIDC-6003 MICROWAVE WIDEBAND DOWNCONVERTER / TUNER UP TO

Keysight Technologies ad Integrated RF Test Solution

FCPM-6000RC. Mini-Circuits P.O. Box , Brooklyn, NY (718)

Multiple Band Outdoor Block Up- and Downconverters

ACION 8000 Series. A8KFR1 1RU Forward Receiver

E4416A/E4417A EPM-P Series Power Meters and E-Series E9320 Peak and Average Power Sensors DATA SHEET

14 GHz, 2.2 kw KLYSTRON GENERATOR GKP 22KP 14GHz WR62 3x400V

Signal Stability Analyser

FREQUENCY CONVERTER HIGH-PERFORMANCE OUTDOOR BLOCK UP AND DOWNCONVERTERS. Narda-MITEQ 1 FEATURES OPTIONS

OTM FREQUENCY AGILE 750MHz F.C.C. COMPATIBLE TELEVISION MODULATOR INSTRUCTION MANUAL

Spectrum Analyzer 1.6 GHz 3 GHz HMS-X

E4416A EPM-P Series Single Channel Power Meter

RF Level Test System +20 dbm to 130 dbm

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

Cable Calibration Function for the 2400B/C and 2500A/B Series Microwave Signal Generators. Technical Brief

CDMA2000 1xRTT / 1xEV-DO Measurement of time relationship between CDMA RF signal and PP2S clock

R-1550A Tempest Wide Range Receiver

SATCOM FIBER OPTIC PRODUCTS

Agilent E4416A/E4417A EPM-P Series Power Meters and E-Series E9320 Peak and Average Power Sensors

Indoor Dual Converter

Keysight Technologies High Power Ampliier Measurements Using Nonlinear Vector Network Analyzer. Application Note

R&S ZV-Z81 Multiport Test Set, models.05/.09/.29 Specifications

DA MHz Series of Narrowband or Wideband Distribution Amplifiers

MICROWAVE MEASURING INSTRUMENTS

Bluetooth Tester CBT. Specifications. Specifications. Version January 2006

Analog & Digital RF-Solutions

DA : Series of Narrowband or Wideband Distribution Amplifiers

LPT-3000 Remote User s Guide (LPT-3000R) LP Technologies

INT-DS2 DVB-S/S2 SATELLITE MODULATOR DVB MODULATOR

HDO701 FIBRE OPTIC TRANSMITTER

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure. 1

R&S SGS100A SGMA RF Source Specifications

Frequency. Range. HP 83751A/B: 2 GHz to 20 GHz HP 83752A/B: 10 MHz to 20 GHz. Standard 10 MHz timebase: f10 ppm

VR5 HD Spatial Channel Emulator

SIDC-5004 VHF/UHF WIDEBAND TUNER/CONVERTER. FREQUENCY RANGE: 20 to 3000 MHz

GFT Channel Slave Generator

Model P/03P Upconverters

2 MHz Lock-In Amplifier

User s Manual of Signal Level Meter TABLE OF CONTENTS

InterReach Fusion Data Sheet

HMC7056. Block Upconverters / HPA's. Typical Applications. General Description. Features. Functional Block Diagram

Optical Receiver Manual. Transmitter OP-OR212JSE. Shenzhen Optostar Optoelectronics Co., Ltd (Version 2)

OBSOLETE HMC7056. Block Upconverters / HPA's. Typical Applications. General Description. Features. Functional Block Diagram

R&S ZVA110 Vector Network Analyzer Specifications

CEDAR Series. To learn more about Ogden CEDAR series signal processing platform and modular products, please visit

Full-featured CW Microwave Counters for Field, Factory or Lab

National Park Service Photo. Utah 400 Series 1. Digital Routing Switcher.

Transcription:

With compliments UFX-EbNo Series Precision Generators Precision E b /N o (C/N) Generators

UFX-EbNo Series Precision E b /N The UFX-EbNo is a fully automated instrument that sets and maintains a highly accurate ratio between a user-supplied carrier and internally generated noise, over a wide range of signal power levels and frequencies. The UFX-EbNo gives system, design, and test engineers in the cellular/pcs, satellite and military communication industries a cost-effective means of obtaining higher yield through automated testing, plus increased confidence from repeatable, accurate test results. Features Multiple Operating Modes The UFX-EbNo provides five operating modes: carrier-tonoise (C/N), carrier-to-noise density (C/N o ), bit energy-tonoise density (E b /N o ), carrier-to-interferer (C/I), and power meter. The instrument can also be used as a precision noise generator. Custom Configurations The UFX-EbNo is available in a variety of configurations to meet your specific testing needs. Applications include: military communications, WCDMA, SATCOM, NASA TDRSS, CableTV, HDTV, IS-95, CDMA, TDMA, UMTS, GPRS L-band modems, Milstar, Inmarsat, Intelsat, and general purpose. Direct Display of E b /N o, C/N, C/I, or C/N o The 4 x 20 VFD screen provides simultaneous readout of all significant input and output signal levels relating to the chosen operating mode, including carrier-to-noise ratios. Accuracy of 0.2 db RSS A special, large-dynamic-range power meter measures both the signal and the noise, which allows the UFX-EbNo to set the desired ration to within ±0.2 db. Special configurations can provide improved accuracy. Bit Rate Entry of 1 bps to 999 Mbps and above In bit energy-to-noise density testing (E b /N o ), the instrument automatically calculates noise density based on the userspecified bit rate. Variable Output Power Output power is user-specified and can be set within the range of 55 dbm to +5 dbm. True RMS Power Meter The digital power meter is custom designed to cover the frequency range of the particular instrument. It can measure signals and noise accurately with Gaussian Noise crest factors up to 18 db. Direct Testing at both RF and Microwave Frequencies In configurations that cover two separate frequency ranges, measurements can be made directly with out the need for special conversion circuitry. Optional Tracking Feature This function is intended for users with an unstable input signal source who wish to perform accurate long-term testing at a specified E b /N o ratio. The tracking option works as an automated gain control (AGC) device, correction for input signal drift up to 0.2 db resolution. The carrier output level is kept constant and, therefore, so is the E b /N o ratio. Setting Precision C/N Ratios The UFX-EbNo accurately sets carrier-to-noise ratios using the substitution calibration method. This method eliminates the effects of any non-linearity in the measuring device, in this case the power meter, by setting the signal and the noise to the same power level at the power meter input. (See the functional block diagram). The noise power is then offset by the desired ratio. The primary source of inaccuracy within the unit is the attenuator that varies the noise power, and Noise Com uses the most accurate components available. Secondary effects such as thermal drift are negligible since the noise and the power are measured within a very short time frame. Active components in the instrument that could be attributed to long-term drift are common to both the signal and noise path, so variations in these components do not affect the calibrated ratio. The unit s linear phase and amplitude signal path ensures that the desired signal passes through undistorted.

o (C/N) Generators Since the UFX-EbNo automatically compensates for parameters like bit rates and bandwidth, taking measurement is as simple as pressing a button. Operating modes, function and parameters are set using the front panel controls. Meter In this mode, the instrument functions as a true RMS power meter, and uses various averaging methods to ensure more accurate readings. Measurements are made through couplers, allowing the signal to pass through to the output connector unaltered by the meter circuitry. E b /N o The instrument automatically sets up a desired E b /N o quickly and accurately. Based on the user-specified carrier output level, output E b /N o ratio, and bit rate, the instrument automatically calculates the required noise density. C/N This mode sets the specified carrier output level and the total noise power in the system bandwidth to the desired ratio. C/N o To obtain a specific C/N o ratio, set the instrument to E b /N o mode and enter zero for the bit rate. All other functions are the same as the E b /N o mode. GEN The instrument can also function as a precision noise generator. Simply select the mode and enter the required noise density. The unit s internal noise source provides the desired signal. Status Indicators and Display Screen Front panel indicators and the 4 x 20 VFD display provide constant feedback on the instrument state and settings. Data Entry and Function Selection Instructions and data are easily entered through the front panel keypad. The instrument can also be controlled through the standard rear panel IEEE- 488-2, optional Ethernet, TCP/IP,or optional RS-232C, RS-422 or RS-423 interfaces. TERM. SP6T SPDT PROG. STEP ATTENUATOR SPDT POWER COMB. Z MATCH C/N OUTPUT INTERFERENCE INPUT TERM. METER RANGE SELECTOR DIGITAL POWER METER CARRIER INPUT Z MATCH TRACKING MODULE PROG. STEP ATTENUATOR SPDT Simplified Functional Block Diagram The internal AWGN precision noise source is summed with the user supplied carrier signal. The unit generates extremely precise E b /N o ratios over a broad range of input or output power. For more information, call 201-261-8797

Specifications Operating modes Carrier-to-noise (C/N), carrier-to-noise density (C/N o ), bit energy-to-noise density (E b /N o ), carrier-to-interferer (C/I), noise generator, power meter. Carrier Path Input power range: -55 dbm to +5 dbm Maximum input power: +21 dbm (with no damage) Output power range: -55 dbm to +5 dbm Nominal gain: ±1.0 db Gain resolution: 0 to 60 db in 0.1 db steps Gain flatness: ±0.2 db for 70 MHz ±20 MHz ±0.3 db for 140 MHz ±40 MHz ±0.4 db for others Group delay: ±0.20 ns/40 MHz for frequencies above 20 MHz Third-order intercept point: +29 dbm typical Tracking range (Ubopt01): +4 db to 4 db Tracking update rate: 100 milliseconds, nominal Noise path Output power range: -55 dbm to +5 dbm Flatness: ±0.2 db/40 MHz ±0.3 db/80 MHz ±0.4 db/200 MHz ±0.5 db/300 MHz Attenuation range: 60 db in 0.25 db steps (0.1 db steps with Ubopt06) Ratio accuracy ±0.2 db RSS, ±0.3 db WCU Power meter range -55 dbm to +5 dbm Power meter accuracy ±0.5 db Power meter averaging 10 to 65,535. Each sample requires approximately 2.2 milliseconds Control Local and IEEE-488 Baud rate (Ubopt04) 150, 300, 600, 1200, 2400, 4800, and 9600 to be used with optional serial interface ports (8 data bits, no parity, 1 stop bit) Interferer input -4 dbm ±2 db. Frequency range is equal to the noise bandwidth. RF connectors BNC-75Ω below 800 MHz, N-type female 50Ω above 800 MHz DC on RF connectors 0 volts, maximum Primary power Voltage 85 to 264 VAC Frequency 47 to 63 Hz Consumption 2 amps, maximum Fuse 2 A Operating temperature 0 to 50 C Dimensions 17 W x 5.25 H x 17.5 D Specification values apply following a 30 minute warmup. Specifications subject to change without notice. 2002 Wireless Telecom Group, Inc. All rights reserved. All trademarks or registered trademarks are the property of their respective holders. Ordering Information Model Number* Frequency Applications Range UFX-EbNo-45 5 to 90 MHz General Purpose UFX-EbNo-70 50 to 90 MHz General purpose/ SATCOM UFX-EbNo-IF1 50 to 90 MHz and Intelsat, SATCOM 100 to 180 MHz UFX-EbNo-IBS/IDR 50 to 90 MHz, Intelsat, SATCOM 68 to 72 MHz, and 100 to 180 MHz UFX-EbNo-255 240 to 270 MHz SATCOM UFX-EbNo-370 350 to 390 MHz NASA TDRSS UFX-EbNo-CATV 50 to 860 MHz Cable TV in 4 bands UFX-EbNo-750 650 to 850 MHz Iridium UFX-EbNo-892 822 to 962 MHz IS-95 (CDMA), IS-136 (TDMA) UFX-EbNo-892/1850 822 to 962 MHz Dual-band CDMA & 1710 to 1990 MHz UFX-EbNo-1200 950 to 1210 MHz L-band modems & 1190 to 1450 MHz UFX-EbNo-1545 1530 to 1560 MHz Inmarsat UFX-EbNo-1850 1710 to 1990 MHz J-STD-008 (CDMA) UFX-EbNo-2050 1900 to 2200 MHz Wideband CDMA UFX-EbNo-2442 2400 to 2484 MHz 802.11b Wireless LAN UFX-EbNo-5500 5000 to 6000 MHz 802.11a Wireless LAN UFX-EbNo-20000 18 to 22 GHz Military Custom Frequency Ranges to 44GHz Option Number Description UEopt01 Automatic gain control to maintain constant carrier power level (Tracking) UEopt03 50Ω input and output impedance** UEopt04 RS-232C, RS-422, or RS-423 interface*** UEopt05 230 VAC, 50 Hz UEopt06 0.1 db/step on output noise and C/N UEopt07 Uninterrupted Carrier during E b N o calibration UEopt08 Dual Channel UEopt09 Ethernet, TCP/IP remote interface UEopt10 0.01dB attenuation, E b /N o resolution**** * Call Noise Com regarding custom configurations ** Below 800 MHz, standard impedance is 75Ω. Above 800 MHz, 50Ω is assumed. *** In addition to standard IEEE-488-2 **** Not available on all models With compliments E. 64 Midland Avenue Paramus, NJ 07652 Phone: (201) 261-8797 Fax: (201) 261-8339 Email: info@noisecom.com Web site: www.noisecom.com

With compliments

With compliments