HeatWave Labs, Inc. 195 Aviation Way, Suite 100 Watsonville, CA Fax

Similar documents
Title: IEEE Transactions on Electron Devices Vol. 36 No. 1. Date Published: January 1989

Pulsed Klystrons for Next Generation Neutron Sources Edward L. Eisen - CPI, Inc. Palo Alto, CA, USA

High-Current Hollow Cathode Development *

A Short History of Thermionic Cathodes B. Vancil 1

CATHODE RAY OSCILLOSCOPE (CRO)

Design and Simulation of High Power RF Modulated Triode Electron Gun. A. Poursaleh

SECTION I INTRODUCTION

Correlation of Hollow Cathode Assembly and Plasma Contactor Data from Ground Testing and In-Space Operation on the International Space Station *

A HIGH POWER LONG PULSE HIGH EFFICIENCY MULTI BEAM KLYSTRON

This work was supported by FINEP (Research and Projects Financing) under contract

4.9 BEAM BLANKING AND PULSING OPTIONS

Lecture 17 Microwave Tubes: Part I

3M Advanced Materials Division. How a connected world stays connected. 3M Cathodes and Electron Guns for reliable long-range communications

SPECIFICATION NO Model 207 Automatic GTAW Welding System

THE OPERATION OF A CATHODE RAY TUBE

THERMIONIC GUN CATHODE-GRID ASSEMBLY TEST PROCEDURE

Interface Practices Subcommittee SCTE STANDARD SCTE Measurement Procedure for Noise Power Ratio

Teaching Plasma Nanotechnologies Based on Remote Access

Detailed Design Report

Defense Technical Information Center Compilation Part Notice

WELDING CONTROL UNIT: TE 450 USER MANUAL

UNIT-3 Part A. 2. What is radio sonde? [ N/D-16]

CNT FIELD EMISSION CATHODE CATALOG. XinRay Systems Inc. April 2014

Development of Multiple Beam Guns for High Power RF Sources for Accelerators and Colliders

THE OPERATION OF A CATHODE RAY TUBE

SPECIFICATION NO NOTE

2000 W, 2450 MHz Microwave Generator GMP 20K SM 56M230 FST 3 IR

Standby...For the Truth

14 GHz, 2.2 kw KLYSTRON GENERATOR GKP 22KP 14GHz WR62 3x400V

Thyratrons. High Energy Switches. Features. Description

E X P E R I M E N T 1

Section C Recorders. DPR mm Digital Strip Chart Recorder

Reliability Guideline: Generating Unit Operations During Complete Loss of Communications

18 GHz, 2.2 kw KLYSTRON GENERATOR GKP 24KP 18GHz WR62 3x400V

NEXT ION OPTICS SIMULATION VIA ffx

Tutorial: Trak design of an electron injector for a coupled-cavity linear accelerator

Cermet cathodes: A new technology for CRT applications

DESIGN AND PERFORMANCE OF L-BAND AND S-BAND MULTI BEAM KLYSTRONS

Certificate of Calibration

Evaluation of Performance, Reliability, and Risk for High Peak Power RF Sources from S-band through X-band for Advanced Accelerator Applications

BitWise (V2.1 and later) includes features for determining AP240 settings and measuring the Single Ion Area.

TEST WIRE FOR HIGH VOLTAGE POWER SUPPLY CROWBAR SYSTEM

ZX-44XL Liquid Fuel Analyzer. User s Manual Version 1.2

ME EN 363 ELEMENTARY INSTRUMENTATION Lab: Basic Lab Instruments and Data Acquisition

Design, Fabrication and Testing of Gun-Collector Test Module for 6 MW Peak, 24 kw Average Power, S-Band Klystron

Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University. Cathode-Ray Oscilloscope (CRO)

Approved by: / / R. Battaglia 12/16/2016

CR7000. CRT Analyzer & Restorer. Easily Test And Restore CRTs With The Most Complete Tests Available For Added Profit And Security.

Monitor QA Management i model

Switching Solutions for Multi-Channel High Speed Serial Port Testing

LAUREL ELECTRONICS, INC.

TOSHIBA Industrial Magnetron E3328

RF Solutions for Science.

MS2540 Current Loop Receiver with RS485 Communication

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Investigation and study on Cathode operating point of SPACE TWTs

Screen investigations for low energetic electron beams at PITZ

EVALUATION OF PERFORMANCE OF SOLAR POWERED FLASHING BEACONS AT ROOM TEMPERATURE CONDITIONS

Status of Pulse Tube Cryocooler Development at Sunpower, Inc.

IOT OPERATIONAL EXPERIENCE ON ALICE AND EMMA AT DARESBURY LABORATORY

Signal Stability Analyser

New Rotary Magnetron Magnet Bar Improves Target Utilization and Deposition Uniformity

INSTRUCTION MANUAL COMMANDER BDH MIG

Approved by Principal Investigator Date: Approved by Super User: Date:

CHAPTER 4 OSCILLOSCOPES

These are used for producing a narrow and sharply focus beam of electrons.

CHAPTER 9. Actives Devices: Diodes, Transistors,Tubes

RGA13, 12/10/17 Ultra High Resolution 20mm Quadrupole with Dual Zone operation

Reciprocating Machine Protection

Effect on Beam Current on varying the parameters of BFE and Control Anode of a TWT Electron Gun

Technical Procedure for Scanning Electron Microscope/ Energy Dispersive X-Ray System (SEM/EDX) for non-gsr Casework

technical note flicker measurement display & lighting measurement

In the tube collection there are several sensors designed for applications in some kinds of physics measurements or detection.

FCC PART 15 CLASS B MEASUREMENT AND TEST REPORT. Tritech Technology Ltd.

Page I-ix / Lab Notebooks, Lab Reports, Graphs, Parts Per Thousand Information on Lab Notebooks, Lab Reports and Graphs

Advanced Test Equipment Rentals ATEC (2832)

There are many ham radio related activities

8500A. Advanced Test Equipment Rentals ATEC (2832) channel capability. For tests on pulse mod- SERIES PEAK POWER METERS

P-224: Damage-Free Cathode Coating Process for OLEDs

Data Sheet. Electronic displays

2x1 prototype plasma-electrode Pockels cell (PEPC) for the National Ignition Facility

TECHNICAL SPECIFICATION Multi-beam S-band Klystron type BT267

CPI Gyrotrons For Fusion EC Heating

SCALE & WEIGHT DISPLAYS

28,000 hour Xenon Hollow Cathode Life Test Results

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

SNG-2150C User s Guide

HIGH VOLTAGE SWITCH PERFORMANCE OF THE EIMAC X-2159 TETRODE ABSTRACT

Activity P27: Speed of Sound in Air (Sound Sensor)

Interface Practices Subcommittee SCTE STANDARD SCTE Composite Distortion Measurements (CSO & CTB)

THE NEW LASER FAMILY FOR FINE WELDING FROM FIBER LASERS TO PULSED YAG LASERS

GENESIS Indoor Air Conditioners

MICROPROCESSOR CALCULATION MODULE - S2000

This document is a reference document that shows the menus in the 5500sc, 9610sc and 9611sc analyzers. There are 3 top-level menus:

SIDRA INTERSECTION 8.0 UPDATE HISTORY

Principles of Electrostatic Chucks 6 Rf Chuck Edge Design

4830A Accelerometer simulator Instruction manual. IM4830A, Revision E1

OF THIS DOCUMENT IS W8.MTO ^ SF6

Development of OLED Lighting Panel with World-class Practical Performance

About vacuum power tubes.

Transcription:

HeatWave Labs, Inc. 195 Aviation Way, Suite 100 Watsonville, CA 95076-2069 831-722-9081 Fax 831-722-5491 E-Mail: techsales@cathode.com The TriService/NASA Cathode Life Test Facility 2002 Annual Report is made available for download with permission from: For further information contact: Commander Lawrence Dressman Code 80943, Bldg. 3168 NAVSURFWARCENDIV 300 Highway 361 Crane, IN 47522-5001 HeatWave Labs, Inc. 195 Aviation Way, Suite 100 Watsonville, CA 95076-2069 techsales@cathode.com

CATHODE LIFE TEST FACILITY ANNUAL REPORT Period Covered February 2001 March 2002 DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited. Crane Division Naval Surface Warfare Center (NAVSURFWARCENDIV) 300 Highway 361 Crane, IN 47522-5001

EXECUTIVE SUMMARY The Cathode Life Test Facility (CLTF) is an independent laboratory that offers a controlled environment and a consistent data-collection methodology for life testing existing and experimental cathode systems. The data is collected to stimulate development of longer life cathode systems for use in microwave tubes supplied to the Government. This document outlines the results of the cathode testing performed at the CLTF during the period February 2001 to March 2002. The CLTF is sponsored by TriService, Naval Research Laboratory (NRL) and NASA, and is operated by Crane Division, Naval Surface Warfare Center (NSWC) Crane, Indiana. The goals of this report are to present data collected from cathodes being tested at the CLTF, to analyze the data and note performance trends among the different types of cathodes, and to inform the cathode community of current and future developments of the CLTF. During this report period the following occurred: Twenty cathode test vehicles accumulated 173,501 hours. The CLTF was re-located to Building 3168 at NSWC Crane.

TABLE OF CONTENTS 1. INTRODUCTION... 1 1.1 Personnel Description... 3 1.1.1 NSWC Crane Personnel... 3 1.1.2 TSC Personnel... 3 1.2 Summary... 3 2. CATHODE DESCRIPTION... 3 2.1 Cathode Description... 3 2.1.1 Cathode Type Designations... 3 2.2 Data Collection... 4 3. ANALYSIS AND PERFORMANCE SUMMARY... 9 3.1 Roll-off Results and Conclusions... 9 3.1.1 M-Type Cathodes... 9 3.1.2 MK-Type Cathodes... 9 3.1.3 MMM-Type Cathodes... 9 3.1.4 RV and V-Type Cathodes... 9 3.1.5 IR-Type Cathodes... 10 3.1.6 IS-Type Cathodes... 10 3.1.7 IO-Type Cathodes... 10 3.2 Long-Term Performance... 10 4. FUTURE WORK...11 4.1 Publication and Presentation of Data...11 TABLE OF FIGURES Figure 1. Life Hours by Cathode Type... 2 TABLE OF TABLES Table 1. Physical Summary of Cathode Systems Tested at the CLTF... 5 Table 2. Emission Degradation... 11 v

APPENDICES A B C D E F G H I J K Summary and Description of CLTF Plant, Equipment and Cathode Test Vehicles Description of CLTF Operations and Maintenance Actions Data Analysis Methods Long-Term Performance Plots Data Summary M and IM Cathode Systems Data Summary MK Cathode System Data Summary MMM Cathode System Data Summary RV and V Cathode Systems Data Summary IR Cathode System Data Summary IS Cathode System Data Summary IO Cathode System vi

CATHODE LIFE TEST FACILITY ANNUAL REPORT 1. INTRODUCTION In November 1992, the Cathode Life Test Facility (CLTF) located at Rome Laboratories was transferred to Crane Division, Naval Surface Warfare Center (NSWC) Crane, Indiana. The facility has operated for approximately 20 years. During this period, many types of cathodes have been tested at the facility and the various cathode test vehicles have accumulated 3,959,889 hours of life testing (see Figure 1). During the period covered by this report, twenty test vehicles were tested. This report summarizes CLTF activities by NSWC Crane from February 2001 through March 2002. The primary aims of this report are to present data collected from cathodes being tested at the CLTF, to analyze the data and note performance trends among the different types of cathodes, and to inform the cathode community of current and future CLTF developments. In addition, the report outlines the data-collection and reduction techniques used to prepare the roll-off curves, kneepoint migration plots, Practical Work Function Distribution (PWFD) plots and long-term performance plots presented in this report, and contains appendices that (1) list the capabilities, equipment, and daily operations of the CLTF, and (2) summarize maintenance actions performed during the past year that may affect the interpretation of the data contained in the report. A series of appendices details CLTF facilities, operations, and methods used to collect data. The remaining appendices contain summary plots of the data. Appendices A and B describe facility operations and contain summary data pertaining to all cathode systems. Methods of data analysis are in Appendix C. The Appendix D contains plots comparing emission degradation of the different types of cathodes tested at CLTF. Each remaining appendix (E through K) contains the long-term performance plot for a cathode system, followed by the Miram plots and the kneepoint migration plots for the individual test vehicles tested during the last annual test cycle (March 2002). 1

LaB6 1400000 1200000 1000000 800000 600000 400000 200000 0 Total On Test No Longer on Test MK B IR CPD CD OX, IO SC RV, V TM MMM TL M, IM Figure 1. Life Test Hours by Cathode Type IP IS Life Test Hours 2

1.1 Personnel Description 1.1.1 NSWC Crane Personnel Mr. L. Dressman (Code 80943) of NSWC Crane is the project engineer and supervises the technical operations of the facility. Mr. R. Sparks (Code 80943) is responsible for the daily activities of the laboratory, including gathering data, and maintaining and repairing the facility. Questions concerning CLTF operation and requests to participate in the cathode life study should be addressed to Mr. Dressman at Address: Commander Attn: Lawrence Dressman Code 80943, Bldg. 3168 NAVSURFWARCENDIV 300 Highway 361 Crane, IN 47522-5001 Phone: (812) 854-4804 1.1.2 TSC Personnel Mr. R. Justice and Mr. A. Qualls of Technology Service Corporation (TSC) authored this report under the direction of NSWC Crane. In addition, Mr. Justice and Mr. Qualls support the CLTF in data analysis. 1.2 Summary During this report period the following occurred: Twenty cathode test vehicles accumulated 173,501 hours. The CLTF was re-located to Building 3168 at NSWC Crane. 2. CATHODE DESCRIPTION 2.1 Cathode Description In its 20 years of operation, the CLTF has received various types of cathodes for testing. In the past, the descriptive data that vendors supplied with each cathode vehicle was informal. Consequently, the level of detail and the format of this data varied considerably among the vendors, making comparison of the cathode systems difficult. NSWC Crane has reviewed the available information on the present and past cathode systems tested at the CLTF; Table 1 summarizes the data. A review of Table 1 indicates the disparity among the descriptions. Some cathodes are not listed in the table because data is unavailable; data for other cathodes is incomplete. 2.1.1 Cathode Type Designations The cathode manufacturers assign the letter designations for the different cathodes. If the manufacturer does not assign a designation, CLTF personnel create one. Each designation represents a specific cathode design. The M designation refers to the standard M-type cathode commonly used in the microwave tube industry. The M-type cathode has a sintered tungsten matrix impregnated with barium oxide and lesser amounts of calcium oxide and aluminum oxide. The emitting surface has an osmium/ruthenium film. The MMM designation refers to a mixed metal matrix cathode with a matrix composition of 80% tungsten and 20% iridium. The matrix is impregnated with typical M-type cathode impregnant compounds. The TM designation refers to another mixed metal matrix cathode. The TM-type cathodes have a matrix of 95% 3

tungsten and 5% iridium, impregnated with standard compounds. The emitting surface has a tungsten/iridium film. The RV designation refers to a reservoir type cathode. RV-type cathodes loaded at 10 A/cm 2 are given the V designation to avoid having RV cathodes with duplicate serial numbers. The RV and V-type cathodes have a porous tungsten button with a tungsten/osmium coating. Behind this button is a barium oxide pellet from which barium diffuses to the button to replenish the emitting surface. The MK designation also refers to a reservoir type cathode. The MK-type cathodes also have a barium oxide reservoir, but have an osmiumcoated tungsten emitter. IO, IP, and IS designations refer to cathodes manufactured by Istok in Moscow, Russia, and supplied to the CLTF by Lawrence Livermore National Laboratory (LLNL). The IO designated cathodes are oxide-coated cathodes. The IM designation refers to Istok manufactured M-type osmium-coated dispenser cathodes. IS devices are scandate dispenser cathodes. The IR designation refers to iridium-coated tungsten dispenser cathodes with a 5:3:2 impregnant mixture. 2.2 Data Collection All daily power supply readings are recorded in the Cathode Life Test Daily Meter Logs and are available for analysis. (See Appendix B for the data-gathering and logging procedures used in the CLTF.) Laboratory personnel use this data to assess the performance of each test station and to ensure operating parameters remain constant. Although it is possible to track cathode degradation using this data, the CLTF does not do so because the large number of data points makes interpretation difficult, and changes over time in power supply calibration bias the daily readings. To produce meaningful degradation analyses, the technique used to measure cathode performance must remain constant throughout the life test period. Therefore, the CLTF bases cathode performance on information obtained from the annual roll-off curves. This data is used to create the graphs contained in the appendices. Appendix C explains the presentation of this data. As discussed in Appendix B, Section B1.1.2, each roll-off curve is recorded after the power supply has been completely recalibrated. This procedure minimizes errors caused by uncalibrated power supply metering. 4

Table 1. Physical Summary of Cathode Systems Tested at the CLTF DISPENSER AND RESERVOIR TYPES Type S/N Matrix Density Matrix Composition Particle Size (microns) Impregnant Molar Ratio Percent Impregnation Film Type Film Thickness (Ångstroms) IR 002 80% 100%W 4.5 IR 006 80% 100%W 4.5 M 001 80% 100%W 4.5 M 005 80% 100%W 4.5 MMM 116 71.52% 80%W/20%Ir 15-16/325 mesh MMM 118 73.35% 80%W/20%Ir 15-16/325 mesh MMM 119 73.09% 80%W/20%Ir 15-16/325 mesh MMM * 120 73.10% 80%W/20%Ir 15-16/325 mesh MMM* 121 73.08% 80%W/20%Ir 15-16/325 mesh MMM* 122 72.94% 80%W/20%Ir 15-16/325 mesh 5:3:2 75 minimum Ir 4000-6000 BaO:CaO:Al2O3 5:3:2 75 minimum Ir 4000-6000 BaO:CaO:Al2O3 5:3:2 75 minimum Os/Ru 4000-6000 BaO:CaO:Al2O3 5:3:2 75 minimum Os/Ru 4000-6000 BaO:CaO:Al2O3 6:1:2 79.11 None BaO:CaO:Al2O3 6:1:2 65.14 None BaO:CaO:Al2O3 6:1:2 65.6 None BaO:CaO:Al2O3 6:1:2 65.91 None BaO:CaO:Al2O3 6:1:2 68 None BaO:CaO:Al2O3 6:1:2 73 None BaO:CaO:Al2O3 * No longer on test. 5

Table 1. Physical Summary of Cathode Systems Tested at the CLTF DISPENSER AND RESERVOIR TYPES Type S/N Matrix Density Matrix Composition Particle Size (microns) Impregnant Molar Ratio Percent Impregnation Film Type Film Thickness (Ångstroms) MMM* 123 73.33% 80%W/20%Ir Not Available MMM* 124 72.98% 80%W/20%Ir 15-16/325 mesh MMM* 125 73.00% 80%W/20%Ir 15-16/325 mesh RV* A002 Not Available 100%W Diffuser Plug 6:1:2 BaO:CaO:Al2O3 6:1:2 BaO:CaO:Al2O3 6:1:2 BaO:CaO:Al2O3 60 None 70 None 74 None 14 High Density BaO Pellet Does Not Apply W/Os 5164 RV* A003 Not Available 100%W Diffuser Plug 14 High Density BaO Pellet Does Not Apply W/Os 5617 RV A005 Not Available 100%W Diffuser Plug 14 High Density BaO Pellet Does Not Apply W/Os 5019 RV A006 Not Available 100%W Diffuser Plug 14 High Density BaO Pellet Does Not Apply W/Os 4688 RV A007 Not Available 100%W Diffuser Plug 14 High Density BaO Pellet Does Not Apply W/Os 4688 RV A008 Not Available 100%W Diffuser Plug 14 High Density BaO Pellet Does Not Apply W/Os 5164 RV A009 Not Available 100%W Diffuser Plug 14 High Density BaO Pellet Does Not Apply W/Os Not Available SC* 003 80% 100%W 4.5 5:3:2 + X BaO:CaO:Al2O3 + Scandium Oxide 75 Minimum None 6

Table 1. Physical Summary of Cathode Systems Tested at the CLTF DISPENSER AND RESERVOIR TYPES Type S/N Matrix Density Matrix Composition Particle Size (microns) Impregnant Molar Ratio Percent Impregnation Film Type Film Thickness (Ångstroms) V Typical Not Available 100%W Diffuser Plug Not Available High Density BaO Pellet Does Not Apply W/Os Not Available TL* 12 80% W+/W/Os 8 TM* B1135 Not Available 95%W/5%Ir Not Available TM* B1240 Not Available 95%W/5%Ir Not Available TM* B1350 Not Available 95%W/5%Ir Not Available TM* B1352 Not Available 95%W/5%Ir Not Available TM* B1455 Not Available 95%W/5%Ir Not Available TM* B1462 Not Available 95%W/5%Ir Not Available TM* B1565 Not Available 95%W/5%Ir Not Available TM* B1667 Not Available 95%W/5%Ir Not Available TM* B1671 Not Available 95%W/5%Ir Not Available TM* B1672 Not Available 95%W/5%Ir Not Available 6:1:2 Not Available Os/Ru+W/Os 4020 BaO:CaO:Al2O3 6:1:2 66 50%W/50%Ir 593 BaO:CaO:Al2O3 6:1:2 73 50%W/50%Ir 4910 BaO:CaO:Al2O3 6:1:2 67 50%W/50%Ir 6034 BaO:CaO:Al2O3 6:1:2 69 50%W/50%Ir 5932 BaO:CaO:Al2O3 6:1:2 73 50%W/50%Ir 6598 BaO:CaO:Al2O3 6:1:2 72 50%W/50%Ir 6598 BaO:CaO:Al2O3 6:1:2 70 50%W/50%Ir 5181 BaO:CaO:Al2O3 6:1:2 65 50%W/50%Ir 4210 BaO:CaO:Al2O3 6:1:2 67 50%W/50%Ir 5211 BaO:CaO:Al2O3 6:1:2 68 50%W/50%Ir 5211 BaO:CaO:Al2O3 7

Table 1. Physical Summary of Cathode Systems Tested at the CLTF DISPENSER AND RESERVOIR TYPES Type S/N Matrix Density Matrix Composition Particle Size (microns) Impregnant Molar Ratio Percent Impregnation Film Type Film Thickness (Ångstroms) MK Typical Not Available 100%W Diffuser Plug Not Available BaO Powder Does Not Apply Os Not Available IM 9, 10 Not Available 100%W Not Available 6:1:2 8-9% Mass Gain Os 4000-6000 BaO:CaO:Al2O3 IS 8 Not Available 100%W Not Available 6:1:1:1 10-11% Mass Gain None BaO:CaO:Al2O3:Sc2O3 IP 5 Does Not Apply Solid Pt/Ba Alloy Emitter Does Not Apply Does Not Apply Does Not Apply None Oxide Types Type S/N Coating Density Coating Thickness Carbonate Particle Size (microns) Carbonate Molar Ratio Coating Substrate Coating Method IO* 1 6-10 mg/cm 2 30-35 microns 1-2 47-43-10 mol % BaO-CaO-SrO Ni Sponge on Solid Ni Air Sputtering IO 3 25-40 mg/cm 2 Not Available Not Available Ni-doped Carbonate Ni Sponge Vacuum/ Pressure Impregnated and Pressed 8

3. ANALYSIS AND PERFORMANCE SUMMARY 3.1 Roll-off Results and Conclusions 3.1.1 M-Type Cathodes M 001 has accumulated 23,965 operating hours and the rate of kneepoint migration has stabilized at a lower value than was expected from the data taken in the first 10,000 hours. The M 001 PWFD is slightly higher than the Best of Class M-type cathode (see Appendix C for an explanation of Best of Class). M 005 appears to have a low work function for an M-type cathode, resulting in an operating temperature of only 885 C. The M 005 PWFD is significantly better than the Best of Class. M 005 also shows a kneepoint migration rate that is less than expected from the early test data. IM 009 and IM 010 are M-type cathodes manufactured by Istok for LLNL. These cathodes are designed to operate at 10 A/cm 2. With approximately 22,000 hours of life testing, these roll-off curves have changed little. The PWFDs of these cathodes were originally lower than the Best of Class M-type cathode, but have increased in the last 10,000 hours. The initial data for all Istok cathodes was taken from digitized hard copies of Miram curve data from initial life testing at Istok. It is advisable to keep in mind that different equipment and test methods were used in the measurements of the initial data in the roll-off plots of all the Istok cathodes. The roll-off data of the Istok cathodes appears to suggest a temperature offset between Istok measurements and CLTF measurements. The numerical roll-off data is not available for the first 5000 hours of life tests, consequently kneepoint migration plots could not be produced for Istok cathodes. 3.1.2 MK-Type Cathodes MK 12 is the only MK cathode still on test. It has accumulated 117,853 hours of testing. The relatively round knee of the roll-off curve belies the performance of this cathode when considering the relatively modest overall movement of the temperature-limited region. The operating temperature for most cathodes undergoing life test is approximately fifty degrees above the knee of the initial roll-off curve. These cathodes have operating temperatures at more than 100 degrees above the knee. The PWFD of this cathode is currently near the Best of Class. The kneepoint migration plot for MK 12 suggests that its work function changed unpredictably over time. 3.1.3 MMM-Type Cathodes MMM-type cathodes still on test have accumulated between 126,045 and 133,801 life hours. The Miram curves for these cathodes (e.g., MMM 119) show anomalous increases in emission in the space-charge-limited region. These levels of increased emission are likely due to a gradual change in electron gun geometry. Temperature-limited emission is unaffected by gun perveance and therefore, it is useful to consider only the temperature-limited portion of these Miram curves. The PWFD plots for these cathodes are all greater than the Best of Class. The kneepoint migration plots for the MMM-type cathodes exhibit a roughly stable or slightly increasing kneepoint temperature. The kneepoint migration intersects the operating temperature at values greater than 150,000 hours. The life data for these cathodes is promising. At a loading of 1 A/cm 2, the cathodes have a potential life of more than 150,000 hours in TWT applications; testing at 2 A/cm 2 indicates 80,000 hours of life could be achieved. 3.1.4 RV and V-Type Cathodes The RV-type cathodes have accumulated between 91,696 and 94,518 hours of life testing. These cathodes all increased in emission for approximately the first 2,000 hours of life testing. The Miram curves now show that some of these cathodes are still above or near their original curves. The PWFD for RV A007 is lower than the Best of Class for this type of cathode. After more than 90,000 hours of life testing, the kneepoint migration plots still indicate a low rate of kneepoint temperature increase. 9

Although the space-charge-limited emission of these cathodes is not consistent from cathode to cathode, the temperature-limited emission of these cathodes indicates a low work function. Projected life for these cathodes is over 100,000 hours at 2 A/cm 2. For space applications, the advantages this cathode has over a typical dispenser cathode would justify the higher initial cost. Developing a production source for RV-type cathodes should be considered. Tests on 10 A/cm 2 V-type reservoir cathodes are proceeding. V 002 and V 003 are being life tested with only heater power applied. Roll-off data is taken with a Miram Curve Generator. The Miram Curve Generator is an automated pulsed power supply. V 002 has accumulated 30,694 hours and has increased space-chargelimited emission but slightly decreased temperature-limited-emission. All V-type cathodes have a PWFD greater than the Best of Class reservoir cathode. V 003 is at 31,518 hours and has increased space-chargelimited emission, but temperature-limited emission is only slightly less than it was at 5371 hours. The operating temperature of V 003 has been reduced from 1150 C to 1079 C, which is 50 degrees above the knee. V 005 and V 150 are being life tested fully loaded at 10 A/cm 2 continuous emission. Both life test stations are undergoing repair; consequently no roll-off data is presented. 3.1.5 IR-Type Cathodes These cathodes have been in operation for 22,587 and 20,455 hours. Since initial data was taken, the kneepoints of these cathodes have moved to higher temperatures. The rate of kneepoint temperature increase is not as great as was indicated earlier in life testing. Because historical data is unavailable for this type of cathode the PWFD plots for the IR cathodes are compared to the Best of Class for the M-type cathode. 3.1.6 IS-Type Cathodes IS 008 is a scandium impregnated dispenser cathode manufactured by Istok. The current IS 008 roll-off data looks better than expected but this is probably due to the difference in measurement techniques (see discussion in section 3.1.1). The PWFD plot for IS 008 is compared to the Best of Class scandate cathode. 3.1.7 IO-Type Cathodes IO 003 data indicates it is at end-of-life. This cathode will be turned off. IO 001 has reached end-of-life and has been turned off. 3.2 Long-Term Performance Table 2 provides emission current degradation data taken during the last roll-off. Unlike other data presented in this report, this data is taken under life test conditions, after power supply calibration. Current degradation data taken throughout life testing is plotted in the long-term performance plots in Appendices D through I. Appendix D provides plots of averages for each cathode type on the same graph. When comparing long-term performance plots of different cathode types, it is important to remember that these are averages, and each cathode type has cathodes that performed above and below the average. It is also important to consider the number of life test hours that have been completed by any two types of cathodes being compared. As the cathodes accumulate more hours, the increased degradation brings down the average over the entire life test. Long-term performance plots are not produced for cathodes that are life tested with only heater voltage applied. Cathode-to-cathode consistency within a cathode type also can be evaluated using the long-term performance plots. The long-term performance scatter plots at the beginning of Appendices E through K provide the contribution of each cathode to the average for each type. 10

Table 2. Emission Degradation Cathode Type S/N Life Hours Loading Operating Temperature Percent Change in Current M 001 23,965 2 928 C T -0.8 M 005 21,317 2 885 C T -0.2 MK 12 117,853 2 1020 C B -0.9 MMM 116 133,801 1 969 C T 16.0 MMM 118 126,045 1 994 C T 13.0 MMM 119 130,651 1 969 C T 21.8 RV A005 94,383 2 952 C T 1.1 RV A006 91,696 4 968 C T 0.8 RV A007 92,510 4 948 C T 5.6 RV A008 94,518 2 933 C T 2.5 RV A009 94,499 2 934 C T -0.4 V H B002 30,694 10 1131 C T V H B003 31,514 10 1079 C T IM H 9 22,480 10 P 1077 C B IM H 10 22,097 10 P 1077 C B IS H 8 17,779 6 P 957 C T IR 002 22,587 2 975 C T -0.4 IR 006 20,455 2 947 C T -0.8 C T = True Temperature (two-color pyrometer) C B = Brightness Temperature (disappearing filament pyrometer) H P = Life tested heater-only, emission tested using Miram Curve Generator = Designed for pulsed operation 4. FUTURE WORK 4.1 Publication and Presentation of Data The CLTF annual report is distributed within the Department of Defense (DoD), NASA, and to the industry participants. Further, the CLTF data is reported at conferences such as the International Vacuum Electron Sources Conference. NSWC Crane intends to continue to ensure the widest possible distribution by publishing of the annual report and reporting data at appropriate conferences. 11

This Page Intentionally Left Blank

APPENDIX A SUMMARY AND DESCRIPTION OF CLTF PLANT, EQUIPMENT AND CATHODE TEST VEHICLES (Unclassified) (2 Pages Attached)

This Page Intentionally Left Blank

APPENDIX A SUMMARY AND DESCRIPTION OF CLTF PLANT, EQUIPMENT AND CATHODE TEST VEHICLES A1. BACKGROUND The CLTF is an independent laboratory offering a controlled environment and a consistent data-collection methodology for life testing existing and experimental cathode systems. This data is collected to stimulate development of longer life cathode systems for use in microwave tubes supplied to the Government. A2. FACILITY During this report period the CLTF was re-located to the main laboratory in Building 3168 of the NSWC Crane Microwave Components Directorate (Code 809). Approximately 840 square feet are devoted to the laboratory, which contains the main test facility and a repair stock storage area. The facility is equipped with 26 cathode life test sets manufactured by Cober Electronics, and two 15 kw test sets developed at NSWC Crane. Each cathode test vehicle has its own power supply and most share an ion pump power supply with other cathode test vehicles. Table A-1 contains the power supply specifications for both types of power supplies. Appendix B reviews the laboratory operations and summarizes maintenance actions that may affect the interpretation of the life data presented in this report. The cathodes tested by the CLTF are packaged into test vehicles by the agency requesting the test. Each cathode test vehicle contains (1) a vacuum envelope (most have an integral ion pump), (2) the test cathode mounted in a gun assembly containing a heater filament and the electrodes necessary to load the cathode to a predetermined current density, and (3) a suitable collector. NSWC Crane has drawings for its preferred configuration, CPI model #V-7355; however, NSWC Crane will consider other options. A-1

Table A-1. Cober Power Supply Electrical Specifications 1. Input Voltage 115 Vac, 1 Phase, 60 Hz Line Regulated 2. Cathode Power Supply Output Voltage Manually adjustable from 0 to -6 kvdc Output Current 0-240 ma Regulation better than 1% Ripple Less than 4 volts peak-to-peak 3. Collector Power Supply Output Voltage Fixed Ratio (30%) of cathode voltage Ripple Less than 5% 4. Filament Power Supply Output Voltage Variable from 0 to 10 Vac Output Current 4 A rms, maximum Regulation Better than 1% 15-KILOWATT CATHODE POWER SUPPLY SPECIFICATIONS 1. Input Voltage 208 Vac, 3 Phase, 60 Hz Line Regulated Load Regulated 2. Cathode Power Supply Output Voltage 0 to -10 kvdc Output Current 0 to 1.5 Adc Regulation 0.01% 3. Filament Power Supply Output Voltage 13 Vac Output Current 5 Aac, maximum A-2

APPENDIX B DESCRIPTION OF CLTF OPERATIONS AND MAINTENANCE ACTIONS (Unclassified) (2 Pages Attached)

This Page Intentionally Left Blank

APPENDIX B DESCRIPTION OF CLTF OPERATIONS AND MAINTENANCE ACTIONS B1. FACILITY OPERATION This appendix summarizes the general operation of the CLTF. It describes the routine operations of the facility. It discusses non-routine events that interrupted the normal life test cycle during the past year and how they may affect data interpretation. It presents the criteria used to determine when cathode test vehicles are removed from testing. B1.1 Scheduled Operations B1.1.1 Daily Operations Each day laboratory personnel read, then record all power supply voltages and currents in the Cathode Life Test Daily Meter Logs. All power supply drifts are eliminated by resetting each power supply to the voltage listed on the voltage settings reference card attached to each power supply. All ion pump readings are checked for any change in test vehicle vacuum level. Any major problems discovered during the daily checks are reported to the project engineer. B1.1.2 Annual Calibrations and Testing Power supply calibrations are performed and cathode roll-off curves are produced annually. Each power supply is calibrated before performing the cathode roll-off test. The data from each cathode roll-off test is used to create a Miram curve, a PWFD plot, and to add data points to the kneepoint migration and longterm degradation plots. The calibration procedure, roll-off test procedure and Miram curve generation guidelines are contained in the Rome Laboratory technical report Cathode Life Prediction (Rome Laboratory report number RL-TR-91-321, dated December 1991). The latest roll-off curves, which form the database for this report, were completed in March 2002. B1.2 Non-Routine Events This section describes the unscheduled events that occurred during the past year. It includes the power outages that occurred and lists power supply malfunctions and the corrective actions taken. Also, it documents the addition and removal of test vehicles. B1.2.1 Re-location All test sets were shut down on 2 August 2001 for facility re-location. Test sets were re-energized on 30 August 2001. Each power supply affected was returned to service following the procedures detailed in Rome Laboratory report, RL-TR-91-321. B1.2.2 Power Supply Malfunctions Four power supply repair actions were recorded in the period covered by this report. The actions that interrupted life testing are listed in Table B-1. B1.2.3 Test Vehicle Activity IO 1 is at end-of-life and has been removed from test. IO 3 appears to be at end-of-life and will undergo further evaluation to determine if it will be removed from test. B-1

B2. DETERMINING END-OF-LIFE At present, end-of-life for a cathode is determined from its Miram curve (see Appendix C for a discussion of Miram curves) and is defined as a 5% reduction in the cathode current at its operating temperature. However, in the past, life tests were commonly continued until a replacement test vehicle became available. Each test vehicle is reviewed after the annual roll-off curves are produced and those cathodes that have reached end-of-life are removed from test. POWER SUPPLY Table B-1. Power Supply Repairs CO12632A Replaced K12. CO12637A CO12643A CO12646B Replaced ETM. FAILURE/REPAIR Replaced body current meter. Replaced ETM. B-2

APPENDIX C DATA ANALYSIS METHODS (Unclassified) (3 Pages Attached)

This Page Intentionally Left Blank

APPENDIX C DATA ANALYSIS METHODS C1. DATA REDUCTION Cathode performance data is presented in four standard forms: (1) as Miram curves for each cathode vehicle, (2) as least-squares-fitted plots of emission versus time for each cathode system, (3) as kneepoint migration plots that summarize the change in kneepoint temperature of the cathode during life testing, and (4) as PWFDs. TYPICAL MIRAM CURVE C1.1 Miram Curves Miram curves standardize data presentations in two ways: (1) each plot shows the cathode s operating temperature as a vertical line referenced to the X axis (temperature), and (2) all currents are expressed as a percentage of the cathode s current at the first data point (highest temperature) of the initial roll-off curve. Each cathode s annual Miram curve is plotted with the cathode s initial Miram curve. Plotting these curves on a single chart visually presents the changes in the cathode s performance. A typical chart is shown in Figure C-1. ent Percent of Initial Curr 110 100 90 80 70 60 50 40 30 Legend 2 A/cm 2 Loading Initial Curve 1018 o C Present Curve 800 850 900 950 1000 1050 1100 1150 1200 Temperature ( o C) Operating Temperature C1.2 Long-Term Performance Plots Figure C-1 In addition to displaying the data as Miram curves for each cathode vehicle, the long-term performance of each cathode system is presented as a degradation plot. In each plot, the scaled current at the operating temperature is plotted as a function of life hours. The resultant plot shows the behavior of the cathode system over time and provides a convenient method of comparing the potential life of different cathode systems. C1.3 Kneepoint Migration Percent of Initial Current 110 100 90 80 70 60 Kneepoint (1000oC, 105.8%) 96,303 Hours Kneepoint Determination Temperature Limited Region Space Charge Limited Region NSWC Crane developed a computer program to calculate kneepoints of roll-off data. This program uses a graphical interface to allow the user to select points that will be used to 850 900 950 1000 1050 1100 1150 1200 Temperature ( o C) calculate the kneepoint. The kneepoint is Figure C-2 defined as the intersection of the best fit line to the data in the space-charge-limited region with the best fit line to the data in the temperature-limited region (see Figure C-2). This report contains kneepoint migration plots that show how quickly the knee temperature of a cathode approaches its operating temperature. A new Windows version of the kneepoint calculation program is available to interested parties. To obtain a copy of this software, contact Mr. Dressman at NSWC Crane (see Section 1.1.1). 50 40 C-1

C1.4 Practical Work Function Distribution This report also includes PWFD plots for all cathodes currently being tested. This data is plotted in the bottom right corner of the Miram curve graph for each cathode (see Figure C-3). The work function data for the PWFD is calculated from the Richardson-Dushman equation J = 2 KT 120 T e φ f(φ) 60 50 40 30 20 Best of Class Current PWFD PWFD using Miram curve data. 1 The function ƒ(φ) is simply the Miram curve percent current scale reflected about the 50% point. If emission data was not taken at 50% then the data was interpolated to give the PWFD a well-defined peak. George Miram developed the PWFD to provide a standard method for assessing cathode quality and predicting life expectancy. For high-quality cathodes, the PWFD width will not 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 φ(ev) change and the peak will not shift throughout its useful life. Initial cathode quality can be assessed by comparing the PWFD of the cathode to the PWFD of the Best of Class (see Figure C-4). The Best of Class represents the best PWFD achieved so far for that type of cathode. Cathodes developed with a PWFD peak lower in work function than the current Best of Class will become the Best of Class. C1.5 Data Organization 10 0-10 Figure C-3 All roll-off data taken at the CLTF is stored in a computer database. The database contains more than 1000 records and is updated after each annual roll-off. Information from this database is available upon request. Requests for data should be directed to Mr. Dressman at NSWC Crane (see Section 1.1.1). 1 G. V. Miram and M. Cattelino, Life Test Facility for Thermionic Cathodes, 1994 TriService/NASA Cathode Workshop. C-2

G. V. Miram, and M. Cattelino, 1994 Life Test Facility for Thermionic Cathodes Conference Record 1994 Tri-Service/NASA Cathode Workshop, Cleveland, 29-31 March. Figure C-4 C-3

This Page Intentionally Left Blank

APPENDIX D LONG-TERM PERFORMANCE PLOTS (Unclassified) (2 Pages Attached)

110 105 100 95 90 85 80 75 70 LONG-TERM PERFORMANCE 2 A/cm 2 IR RV SC MK MMM B M 0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000 110000 120000 130000 140000 Life Hours Percent of Initial Current D-1

110 105 100 95 90 85 80 75 70 LONG-TERM PERFORMANCE 4 A/cm 2 RV MK M TM 0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000 110000 120000 130000 140000 Life Hours Percent of Initial Current D-2

This Page Intentionally Left Blank

APPENDIX E DATA SUMMARY M AND IM CATHODE SYSTEMS (Unclassified) (8 Pages Attached)

110 105 100 95 90 85 80 75 70 M LONG-TERM PERFORMANCE 2 A/cm 2 M 202 M 209 M 210 M 215 M 218 M 001 M 005 Best Fit Line 0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000 110000 120000 130000 140000 Life Hours Percent of Initial Current E-1

110 105 100 95 90 85 80 75 70 M LONG-TERM PERFORMANCE 4 A/cm 2 M 212 Best Fit Line 0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000 110000 120000 130000 140000 Life Hours Percent of Initial Current E-2

110 100 90 80 70 60 50 40 IM 009 MIRAM CURVE Initial Data, 1000 Hours (See Note) March 2002, 22480 Hours Operating Temperature 1077 C 10 A/cm 2 60 PWFD 50 Best of Class* Current PWFD 40 30 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 φ(ev) 900 950 1000 1050 1100 1150 1200 Temperature ( C) Percent of Initial Current f(φ) 20 10 0-10 NOTE: Initial data taken at Istock using different test methods and equipment. * See explanation of Best of Class in Appendix C. E-3

110 100 90 80 70 60 50 40 IM 010 MIRAM CURVE Initial Data, 1000 Hours (See Note) March 2002, 22097 Hours Operating Temperature 1077 C 10 A/cm 2 60 PWFD 50 Best of Class* Current PWFD 40 30 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 φ(ev) 900 950 1000 1050 1100 1150 1200 Temperature ( C) Percent of Initial Current f(φ) 20 10 0-10 NOTE: Initial data taken at Istock using different test methods and equipment. * See explanation of Best of Class in Appendix C. E-4

110 100 90 80 70 60 50 40 M 001 MIRAM CURVE October, 1999 4730 Hours February 2002, 23965 Hours Operating Temperature 928 C 2 A/cm 2 60 50 PWFD Best of Class* Current PWFD 40 30 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 φ(ev) 750 800 850 900 950 1000 1050 1100 1150 1200 Temperature ( C) Percent of Initial Current f(φ) 20 10 0-10 * See explanation of Best of Class in Appendix C. E-5

1100 1050 1000 950 900 850 800 M 001 KNEEPOINT MIGRATION Slope = 9.23 C / 10,000 Hours Operating Temperature = 928 C 0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000 110000 120000 130000 140000 Life Test Hours Kneepoint Temperature C E-6

110 100 90 80 70 60 50 40 M 005 MIRAM CURVE October 1999, 2532 Hours February 2002, 21317 Hours Operating Temperature 885 C 2 A/cm 2 60 PWFD 50 Best of Class* Current PWFD 40 30 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 φ(ev) 700 750 800 850 900 950 1000 1050 1100 Temperature ( C) Percent of Initial Current f(φ) 20 10 0 * See explanation of Best of Class in Appendix C. E-7

1100 1050 1000 950 900 850 800 M 005 KNEEPOINT MIGRATION Operating Temperature = 885 C Slope = 4.77 C / 10,000 Hours 0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000 110000 120000 130000 140000 Life Test Hours Kneepoint Temperature C E-8

This Page Intentionally Left Blank

APPENDIX F DATA SUMMARY MK CATHODE SYSTEM (Unclassified) (4 Pages Attached)

110 105 100 95 90 85 80 75 70 MK LONG-TERM PERFORMANCE 2 A/cm 2 MK 2 MK 6 MK 7 MK 12 Best Fit Line 0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000 110000 120000 130000 140000 Life Hours Percent of Initial Current F-1

110 105 100 95 90 85 80 75 70 MK LONG-TERM PERFORMANCE 4 A/cm 2 MK 4 MK 8 MK 17 Best Fit Line 0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000 110000 120000 130000 140000 Life Hours Percent of Initial Current F-2

110 100 90 80 70 60 50 40 MK 12 MIRAM CURVE September 1986, 2978 Hours February 2002, 117853 Hours Operating Temperature Smoothed Curve 2 A/cm 2 1020 C 60 50 PWFD Best of Class* Current PWFD 40 30 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 φ(ev) 800 850 900 950 1000 1050 1100 1150 1200 1250 Temperature ( C) Percent of Initial Current f(φ) 20 10 0 * See explanation of Best of Class in Appendix C. F-3

1100 1050 1000 950 900 850 800 MK 12 KNEEPOINT MIGRATION Operating Temperature = 1020 C Slope = 2.01 C / 10,000 Hours 0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000 110000 120000 130000 140000 Life Test Hours Kneepoint Temperature C F-4

This Page Intentionally Left Blank

APPENDIX G DATA SUMMARY MMM CATHODE SYSTEM (Unclassified) (8 Pages Attached)

110 105 100 95 90 85 80 75 70 MMM LONG-TERM PERFORMANCE 1 A/cm 2 MMM 116 MMM 118 MMM 119 Best Fit Line 0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000 110000 120000 130000 140000 Life Hours Percent of Initial Current G-1

110 105 100 95 90 85 80 75 70 MMM LONG-TERM PERFORMANCE 2 A/cm 2 MMM 120 MMM 121 MMM 122 MMM 123 MMM 124 MMM 125 Best Fit Line 0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000 110000 120000 130000 140000 Life Hours Percent of Initial Current G-2

120 110 100 90 80 70 60 50 40 MMM 116 MIRAM CURVE October 1982, 48 Hours February 2002, 133801 Hours Operating Temperature 969 C 1 A/cm 2 60 50 PWFD Best of Class* Current PWFD 40 30 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 φ(ev) 750 800 850 900 950 1000 1050 1100 1150 1200 Temperature ( C) Percent of Initial Current f(φ) 20 10 0 * See explanation of Best of Class in Appendix C. G-3

1100 1050 1000 950 900 850 800 MMM 116 KNEEPOINT MIGRATION Operating Temperature = 969 C Slope = 2.38 C / 10,000 Hours 0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000 110000 120000 130000 140000 Life Test Hours Kneepoint Temperature C G-4

120 110 100 90 80 70 60 50 40 MMM 118 MIRAM CURVE November 1982, 140 Hours February 2002, 126045 Hours Operating Temperature Smoothed Curve 1 A/cm 2 994 C 60 50 PWFD Best of Class* Current PWFD 40 30 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 φ(ev) 800 850 900 950 1000 1050 1100 1150 1200 1250 Temperature ( C) Percent of Initial Current f(φ) 20 10 0 * See explanation of Best of Class in Appendix C. G-5

1100 1050 1000 950 900 850 800 MMM 118 KNEEPOINT MIGRATION Operating Temperature = 994 C Slope = 3.31 C / 10,000 Hours 0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000 110000 120000 130000 140000 Life Test Hours Kneepoint Temperature C G-6

140 130 120 110 100 90 80 70 60 50 40 MMM 119 MIRAM CURVE December 1982, 124 Hours February 2002, 130651 Hours Operating Temperature Smoothed Curve 969 C 1 A/cm 2 60 PWFD 50 Best of Class* Current PWFD 40 30 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 φ(ev) 750 800 850 900 950 1000 1050 1100 1150 1200 Temperature ( C) Percent of Initial Current f(φ) 20 10 0 * See explanation of Best of Class in Appendix C. G-7

1100 1050 1000 950 900 850 800 MMM 119 KNEEPOINT MIGRATION Operating Temperature = 969 C Slope = 3.72 C / 10,000 Hours 0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000 110000 120000 130000 140000 Life Test Hours Kneepoint Temperature C G-8

This Page Intentionally Left Blank

APPENDIX H DATA SUMMARY RV AND V CATHODE SYSTEMS (Unclassified) (16 Pages Attached)

110 105 100 95 90 85 80 75 70 RV LONG-TERM PERFORMANCE 2 A/cm 2 RV A003 RV A005 RV A008 RV A009 Best Fit Line 0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000 110000 120000 130000 140000 Life Hours Percent of Initial Current H-1

110 105 100 95 90 85 80 75 70 RV LONG-TERM PERFORMANCE 4 A/cm 2 RV A002 RV A006 RV A007 Best Fit Line 0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000 110000 120000 130000 140000 Life Hours Percent of Initial Current H-2

110 100 90 80 70 60 50 40 RV A005 MIRAM CURVE March 1990, 273 Hours February 2002, 94383 Hours Operating Temperature 952 C 2 A/cm 2 60 PWFD 50 Best of Class* Current PWFD 40 30 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 φ(ev) 750 800 850 900 950 1000 1050 1100 1150 1200 Temperature ( C) Percent of Initial Current f(φ) 20 10 0-10 * See explanation of Best of Class in Appendix C. H-3

1100 1050 1000 950 900 850 800 RV A005 KNEEPOINT MIGRATION Operating Temperature = 952 C Slope = 0.45 C / 10,000 Hours 0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000 110000 120000 130000 140000 Life Test Hours Kneepoint Temperature C H-4

110 100 90 80 70 60 50 40 RV A006 MIRAM CURVE March 1990, 197 Hours February 2002, 91696 Hours Operating Temperature 4 A/cm 2 968 C 60 PWFD 50 Best of Class* Current PWFD 40 30 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 φ(ev) 750 800 850 900 950 1000 1050 1100 1150 1200 Temperature ( C) Percent of Initial Current f(φ) 20 10 0-10 * See explanation of Best of Class in Appendix C. H-5

1100 1050 1000 950 900 850 800 RV A006 KNEEPOINT MIGRATION Operating Temperature = 968 C Slope = 2.57 C / 10,000 hours 0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000 110000 120000 130000 140000 Life Test Hours Kneepoint Temperature C H-6

110 100 90 80 70 60 50 40 RV A007 MIRAM CURVE March 1990, 209 Hours February 2002, 92510 Hours Operating Temperature 948 C 4 A/cm 2 60 PWFD 50 Best of Class* Current PWFD 40 30 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 φ(ev) 750 800 850 900 950 1000 1050 1100 1150 1200 Temperature ( C) Percent of Initial Current f(φ) 20 10 0-10 * See explanation of Best of Class in Appendix C. H-7

1100 1050 1000 950 900 850 800 RV A007 KNEEPOINT MIGRATION Operating Temperature = 948 C Slope = 2.56 C / 10,000 Hours 0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000 110000 120000 130000 140000 Life Test Hours Kneepoint Temperature C H-8

110 100 90 80 70 60 50 40 RV A008 MIRAM CURVE March 1990, 234 Hours February 2002, 94518 Hours Operating Temperature 933 C 2 A/cm 2 60 PWFD 50 Best of Class* Current PWFD 40 30 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 φ(ev) 750 800 850 900 950 1000 1050 1100 1150 1200 Temperature ( C) Percent of Initial Current f(φ) 20 10 0-10 * See explanation of Best of Class in Appendix C. H-9

1100 1050 1000 950 900 850 800 RV A008 KNEEPOINT MIGRATION Operating Temperature = 933 C Slope = 1.62 C / 10,000 Hours 0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000 110000 120000 130000 140000 Life Test Hours Kneepoint Temperature C H-10

110 100 90 80 70 60 50 40 RV A009 MIRAM CURVE March 1990, 156 Hours February 2002, 94499 Hours Operating Temperature 934 C 2 A/cm 2 60 PWFD 50 Best of Class* Current PWFD 40 30 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 φ(ev) 750 800 850 900 950 1000 1050 1100 1150 1200 Temperature ( C) Percent of Initial Current f(φ) 20 10 0-10 * See explanation of Best of Class in Appendix C. H-11

1100 1050 1000 950 900 850 800 RV A009 KNEEPOINT MIGRATION Operating Temperature = 934 C Slope = 0.58 C / 10,000 Hours 0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000 110000 120000 130000 140000 Life Test Hours Kneepoint Temperature C H-12

110 100 90 80 70 60 50 40 V B002 MIRAM CURVE February 1999, 4341 Hours March 2002, 30694 Hours Operating Temperature 1110 C 10 A/cm 2 60 PWFD 50 Best of Class* Current PWFD 40 30 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 φ(ev) 950 1000 1050 1100 1150 1200 1250 Temperature ( C) Percent of Initial Current f(φ) 20 10 0-10 * See explanation of Best of Class in Appendix C. H-13

1150 1100 1050 1000 950 V B002 KNEEPOINT MIGRATION Operating Temperature = 1110 C Slope = 5.67 C / 10,000 Hours 0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000 110000 120000 130000 140000 Life Test Hours Kneepoint Temperature C H-14

120 110 100 90 80 70 60 50 40 V B003 MIRAM CURVE February 1999, 5371 Hours March 2002, 31514 Hours Operating Temperature 1079 C 10 A/cm 2 60 PWFD 50 40 Best of Class* Current PWFD 30 20 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 φ(ev) 900 950 1000 1050 1100 1150 1200 1250 Temperature ( C) Percent of Initial Current f(φ) 10 0-10 -20 * See explanation of Best of Class in Appendix C. H-15

1200 1150 1100 1050 1000 V B003 KNEEPOINT MIGRATION Operating Temperature = 1079 C Slope = 5.41 C / 10,000 Hours 0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000 110000 120000 130000 140000 Life Test Hours Kneepoint Temperature C H-16

This Page Intentionally Left Blank

APPENDIX I DATA SUMMARY IR CATHODE SYSTEM (Unclassified) (5 Pages Attached)

This Page Intentionally Left Blank

110 105 100 95 90 85 80 75 70 IR LONG-TERM PERFORMANCE 2 A/cm 2 IR 002 IR 006 Best Fit Line 0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000 110000 120000 130000 140000 Life Hours Percent of Initial Current I-1

110 100 90 80 70 60 50 40 IR 002 MIRAM CURVE July 1999, 1791 Hours February 2002, 22587 Hours Operating Temperature 975 C 2 A/cm 2 60 50 PWFD Best of Class* Current PWFD 40 30 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 φ(ev) 800 850 900 950 1000 1050 1100 1150 1200 1250 Temperature ( C) Percent of Initial Current f(φ) 20 10 0-10 * See explanation of Best of Class in Appendix C. I-2

1100 1050 1000 950 900 850 800 IR 002 KNEEPOINT MIGRATION Operating Temperature = 975 C Slope = 5.24 C / 10,000 Hours 0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000 110000 120000 130000 140000 Life Test Hours Kneepoint Temperature C I-3

110 100 90 80 70 60 50 40 IR 006 MIRAM CURVE October 1999, 2063 Hours February 2002, 20455 Hours Operating Temperature 947 C 2 A/cm 2 60 50 PWFD Best of Class* Current PWFD 40 30 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 φ(ev) 800 850 900 950 1000 1050 1100 1150 1200 1250 Temperature ( C) Percent of Initial Current f(φ) 20 10 0 * See explanation of Best of Class in Appendix C. I-4

1100 1050 1000 950 900 850 800 IR 006 KNEEPOINT MIGRATION Slope = 17.17 C / 10,000 Hours Operating Temperature = 947 C 0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000 110000 120000 130000 140000 Life Test Hours Kneepoint Temperature C I-5

This Page Intentionally Left Blank X-X

APPENDIX J DATA SUMMARY IS CATHODE SYSTEM (Unclassified) (1 Page Attached)

This Page Intentionally Left Blank

IS 008 MIRAM CURVE 110 100 Initial Data, 1000 Hours (See Note) March 2002, 17779 Hours Operating Temperature 957 C 6 A/cm 2 90 80 60 50 PWFD Best of Class* Current PWFD 70 40 30 60 50 40 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 φ(ev) 700 750 800 850 900 950 1000 1050 1100 1150 1200 Temperature ( C) Percent of Initial Current f(φ) 20 10 0-10 NOTE: Initial data taken at Istock using different test methods and equipment. * See explanation of Best of Class in Appendix C. J-1

This Page Intentionally Left Blank

APPENDIX K DATA SUMMARY IO CATHODE SYSTEM (Unclassified) (1 Page Attached)

This Page Intentionally Left Blank

110 100 90 80 70 60 50 40 IO 003 MIRAM CURVE Initial Data, 1000 Hours (See Note) February 2002, 16966 Hours Operating Temperature 2 A/cm 2 800 C 60 50 PWFD Best of Class* Current PWFD 40 30 1.2 1.4 1.6 1.8 2.0 φ(ev) 750 800 850 900 950 1000 1050 1100 1150 Temperature ( C) Percent of Initial Current f(φ) 20 10 0 NOTE: Initial data taken at Istock using different test methods and equipment. * See explanation of Best of Class in Appendix C. K-1

This Page Intentionally Left Blank