IL591 SECTION D Rev /2011. Tek-SAFE NC150R Area of Rescue Assistance System. Operation, Installation and Service Manual

Similar documents
Installation Manual SaVi Note Underwater LED Light

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

Caution. Hanging the Screen:

IndyGo Facility Upgrades Project 35671EE

Product Manual MNX10015 / REV C MODEL SB142, SB242. Dual Output Series Switch Boxes

CR-R880-BL: Indoor/Outdoor Proximity Reader with 10cm (4in) read range

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

Warner Photoscanner MCS-500 Series LED Photoelectric Control

Master Time Clock MTC Users Manual

Distributed Design Series

Product information. Front-door station series with video for surface-mount

3 Cleaning. 4 Technical data

ICS Digital Menu. Installation Guide Version 1.1

EZCOM-1. PLC - to - AMS MESSAGE DISPLAY INTERFACE INSTALLATION AND OPERATING INSTRUCTIONS. Rev March, 2001

Hi-Rez Projections Inc. 20 Main St. Ashland, MA MP8 CRT Installation

SPECIAL SPECIFICATION 2344 TMC Support Equipment

Site Installation Model MP-8433

MODELS USIX-024 AND USIX-120 INSTRUCTION SHEET FOR FEDERAL SIGNAL UNISTAT STATUS INDICATOR MODEL USIX

STX Stairs lighting controller.

Sign Illuminating Ballasts

Model DT-311J. And DT-311J-230V(AC) DIGITAL STROBOSCOPE INSTRUCTION MANUAL

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

GE Interlogix Fiber Options S700V & S702V. Instruction Manual FIBER-OPTIC VIDEO TRANSMISSION SYSTEM

PREPAX DELUXE INTERCOM SYSTEMS

INSTRUCTION MANUAL [J] [E] [C] [G] [B] [I] [H] [D] [F] [A] 0 INTRODUCTION 1 RECOMMENDATIONS 2 ACCESSORIES INCLUDED

OWNER'S MANUAL SIGNAL COMMANDER

ART2000i Digital Dimming System. Installation guide. Stock number *8200-

SECTION COMMUNICATIONS HORIZONTAL CABLING

VALCOM HANDSFREE TALKBACK PAGING SYSTEM DESIGN/INFORMATION

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

.Power Distribution Center. PD-1. Instruction Manual

Site Installation Model MP-8424

VT VGA TFT NEMA 4/12 Flat Panel Monitor. User s Guide

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

Timer Modules. EL11 24 Hour Module EL17 7 Day Module. Installation & Operating Instructions

Modular Lube Lubrication Systems System Controls

SUBCARRIER TRANSFER FILTER INSTRUCTION BOOK IB622702

Operation Manual VMS 3.0 Video System

INSTRUCTION BOOK FOR. Lectern

INSTALLATION INSTRUCTIONS MODEL VSBX-236 LED 3 X 8 INDOOR SCOREBOARD

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

LIGHT COPILOT II. elationlighting.com Internet:

Model /29S RF Splitter

Photovoltaic Module Installation Manual (IEC)

Instromet Weather Systems Ltd

Touch Panel RGB LED Controller Part No. touch-panel-rgb

MARINE HORNS V-1030M - 5 WATT PAGING HORN AMPLIFIER ASSEMBLY V-1036M - 15 WATT PAGING HORN AMPLIFIER ASSEMBLY V-1048M - 45 OHM TALKBACK HORN

TAC1 Telephone Entry System

AUTOMATIC VIDEO LOSS A/B SWITCH

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

TV Lift System Model CL-65 Installation Instructions

SQM40/41 Actuators for air and gas dampers

Trusted 40 Channel 120 Vac Digital Input FTA

Installation Guide VL-MV10. Model No.

INSTALLATION AND OPERATION M

Telemetry Receiver Installation Guide

ImproX (TRT) Twin Remote Terminal INSTALLATION MANUAL

Instructions for Use P.154-UP (9/4) P.155-UP (9/8) P.150-UP-12 (9/12) P.150-UP-16 (9/16)

TracVision R6DX Installation Guide

Low Profile Digital HDTV Over-the-Air Antenna CONTENTS

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

Trusted 40 Channel 120 Vac Digital Input FTA

USER MANUAL Table of Contents

OWNER'S MANUAL SIGNAL COMMANDER

By CHANNEL VISION. Flush Mount Amplifier A0350

INSTALLATION INSTRUCTIONS FOR. MODEL 2230LED

Photovoltaic Module Installation Manual (IEC)

SCALE & WEIGHT DISPLAYS

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

A. Section Includes: Division 1 applies to this section. Provide GPS wireless clock system, complete.

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

K Service Source. Apple High-Res Monochrome Monitor

SECTION INTERCOMMUNICATIONS AND PROGRAM SYSTEMS

INSTALLATION INSTRUCTIONS FOR

S Regulators. Supplement 1. Contents. Control Replacement Assembly Installation Instructions Supplement

INSTALLATION GUIDE. Axle Weighing Truck Scale. 60,000 lb x 20 lb Factory Calibrated Includes Pre-interfaced Wireless Remote LED Scoreboard Displays

CONTRACTORS SPECIFICATION

Design and Manufacture of Video Pipeline Inspection Systems A Full Service Company

Documentation on all Paxton products can be found on our web site -

JACK Digital HDTV Over-the-Air Antenna

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

OA White OA Black. Owner s Manual. Low Profile Digital HDTV Over-the-Air Antenna. w/built-in KING SureLock Digital TV Signal Meter

Ophera Hands Free Color Video Receiver and Accessories

Colour Explosion Proof Video Camera USER MANUAL VID-C

Omnidirectional TV/FM Antenna

Tectiv 220 Instructions for use

414 P 1. DESCRIPTION AND TECHNICAL SPECIFICATIONS 2. LAY-OUT OF STANDARD SYSTEM INSTALLATION DIMENSIONS. Fig. 1. Fig. A

Instructions for Use P.160-AP-8 (13/8) P.160-CP-8 (13/8) P.160-CP-12 (13/12) P.160-CP-16 (13/16)

SIR-GM1 GM CLASS-2 BUS COMPATIBLE SIRIUS SATELLITE RADIO TUNER

Crimp & Cleave Termination Instructions for SEL ST Connectors

Installation Manual for New or Retrofit Installations

3 Foam Sealed Closure 2" (50 mm) with Compound Compression

JACK Digital HDTV Over-the-Air Antenna w/built-in SureLock Digital TV Signal Meter

Filters for Power Lines (Low Leakage Current)

MAXX BOX. MX102/202 Series. MAXX Box

2002 Martin Professional A/S, Denmark.

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

Solid-State Digital Timer

PC-250. SMD Taped Parts Counter Operator s Manual. ISO 9001:2008 Certified. V-TEK, Incorporated 751 Summit Avenue Mankato, MN USA

Transcription:

IL591 SECTION D Rev. 12-03/2011 Tek-SAFE NC150R Area of Rescue Assistance System Operation, Installation and Service Manual Alpha Communications 42 Central Drive Farmingdale, NY 11735-1202 Phone: (631) 777-5500 Fax: (631) 777-5599 Website: www.alphacommunications.com Email: info@alphacommunications.com TOLL-FREE Technical #: 1-800-666-4800 The Tek-Safe NC150R Area of Rescue Assistance System provides communication between area of rescue assistance stations (in protected stairwells) and the building lobby. Calls are indicated at the NC150R Master Station by both visual and audible signals. The master station also has sensitive two-way communication to the IR150B, IR150N, IR150SS and IR150SS/S Remote Call Stations. Tek-SAFE meets ADA requirements for area of rescue assistance systems (check local codes for additional requirements).

Operation, Installation and Service Manual Copyright 2003 2011 TekTone Sound & Signal Mfg., Inc., All rights reserved. No part of this publication may be copied without the express written permission of TekTone Sound & Signal Mfg., Inc. The content of this manual is furnished for informational use only, is subject to change without notice, and should not be construed as a commitment by TekTone Sound & Signal Mfg., Inc. TekTone Sound & Signal Mfg., Inc. assumes no responsibility or liability for any errors or inaccuracies that may appear in this documentation. TekTone, the TekTone logo, Tek-Call, Tek-Care, Tek-Check-In, Tek-Com, Tek-Digicare, Tek-Door, Tek-Entry III, Tek-Guard, Tek- Micro, Tek-Micro II, Tek-MMARS II, TekNIOS, TekNIOS II, Tek-Paging, Tek-Phone, Tek-Safe, Tek-Select II, Tek-Sentry, Tek- Sound, Tek-Status, Tek-Trio and Tek-View are either registered trademarks or trademarks of TekTone Sound & Signal Mfg., Inc. in the United States and/or other countries. All other trademarks are the property of their respective owners. ii IL591 Tek-SAFE Area of Rescue Assistance Manual Copyright TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

Table of Contents System Operating Instructions... 1 NC150R Master Station... 1 IR150B, IR150N, IR150SS, IR150SS/S Remote Call Stations... 1 System Installation... 3 Installation Procedure... 3 Equipment Locations... 3 NC150R Master Station... 3 IR150B, IR150N, IR150SS, IR150SS/S Remote Call Stations... 3 PK151A, PK152 Power & Control Units... 3 Wiring Installation... 3 Housing Installation... 3 NC150R Master Station... 3 IR150B Remote Call Stations... 3 IR150N Remote Call Stations... 3 IR150SS Remote Call Stations... 3 IR150SS/S Remote Call Stations... 3 PK151A or PK152 Power & Control Unit, SS106 24 VAC 30 VA Transformer, IH151N Junction Box... 3 Wire Checkout... 4 Wire Connections... 4 Connections Checkout... 4 System Test Instructions... 4 System Maintenance Instructions... 6 NC150R Master Stations... 6 Replacement Parts... 7 Frameable Users Guide... 8 Illustrations Figure 1 Master and Remote Call Station Control Locations... 2 Figure 2 Master Panel Housing Chart and Wall Cut-Out Details... 2 Figure 3 Panel Removal & Replacement... 2 Figure 4 Ring & Back Box for IR150B Remote Call Stations... 2 Figure 5 SS106 Transformer Installation... 4 Figure 6 NC150R Selector Lamp/Switch Lens, Filter and Lamp Replacement... 4 Figure 7 Tek-SAFE System Wiring Diagram... 5 Copyright TekTone Sound & Signal Mfg., Inc. All Rights Reserved. IL591 Tek-SAFE Area of Rescue Assistance Manual iii

System Operating Instructions This section provides complete operating instructions for all Tek-SAFE functions, as well as reference drawings for use in locating and describing all controls. System operators must read the following operating instructions concerning system equipment and the terms used in conjunction `with the equipment. NC150R Master Station Refer to Figure 1 for locations, names and functions of controls and indicators. Answer a Call: Normal calls are indicated by simultaneous operation of the following signals: Steady illumination of the associated station selector lamp which is marked to indicate call origin, steady illumination of call lamp, and slowly pulsing audible tone. To establish conversation with the calling station, press the associated station selector button. The remote station s in use LED will illuminate. To speak to the caller, press the TALK button while speaking and release to listen. When the conversation is complete, press the associated station selector button to release the station. The remote station s in use LED will turn off. Call a Remote Call Station: Locate the station selector button associated with the station to be called. Press that selector button to establish a conversation path. The remote call station s in use LED will illuminate. To produce an announcing tone at the remote call station, press the TALK and CALL buttons simultaneously. Press the TALK button while speaking, and release to listen. The remote area may be monitored by selecting the remote station and releasing the TALK button. When conversation or monitoring is complete, press the station selector button to release it. The remote station s in use LED will turn off. Test Station Selector Lamps: Press TEST button. All station selector lamps should illuminate. Improper Operation: If the NC150R Master Station fails to operate as described, contact qualified maintenance personnel. There are no user replaceable parts on the NC150R Master Stations other than the station selector lamps. IR150B, IR150N, IR150SS, IR150SS/S Remote Call Stations Refer to Figure 1 for locations, names and functions of controls and indicators. Call the NC150R Master Station: Press the CALL button. The call placed lamp will illuminate to indicate call placement. When the call is answered, the call placed lamp will go off and the in use LED will illuminate to indicate a communication path has been established to the master station. Speak in a normal voice. Cancel a Call: Press the RESET or CANCEL button. Call placed lamp will go off. Improper Operation: Contact qualified service personnel if the station does not operate as described. There are no user serviceable parts on the IR150B, IR150N, IR150SS, IR150SS/S Remote Call Stations. Copyright TekTone Sound & Signal Mfg., Inc. All Rights Reserved. IL591 Tek-SAFE Area of Rescue Assistance Manual 1

NC150R Master Station Figure 1 Master and Remote Call Station Control Locations IR150SS, IR150SS/S Remote Call Station 8 5 IR150N Remote Call Station AUDIO 6 4 3 1 2 1 Call Button: Tone call to selected remote when pressed. Call Lamp: Indicates incoming call when illuminated. 2 Talk Button: Talk when pressed. Listen when released. 3 Selector Buttons: Establishes conversation path with associated remote station when depressed. Selector Lamps: Indicates incoming call from associated remote when illuminated. 4 Call Button: Places a call when pressed. 5 Call Placed Lamp: Indicates a call is placed when illuminated. 6 Reset Button: Cancels the call when pressed. 7 In Use LED: Indicates station is in use when illuminated. 8 Audio On Lamp: Indicates master station is listening when illuminated. 8 4 6 5 IR150B Remote Call Station 6, 7 4, 5 Figure 2 Master Panel Housing Chart and Wall Cut-Out Details 4" min. Finished Wall 11.625" 16" 4.4375" 11.625" 4.4375" 4.4375" 3.75" 66" Finished Floor In masonry walls, install 0.5" 4" wood fillers at top and bottom of opening for housing attachment. Wall Opening Flush Housing Width Height OH150 4-7/16" 11-5/8" Figure 3 Panel Removal & Replacement Panel Removal: First remove the self-tapping metal screws located in the top U-channel just above each panel. Then lift up on panel to clear bottom channel. After removal, adequate space is available to grasp and remove the remaining panels. Figure 4 Ring & Back Box for IR150B Remote Call Stations Panel Replacement: Insert top of panel into top channel, push panel in at bottom, and release. Panel should fall into place in bottom channel. Replace self-tapping metal screws. Install ring with panel mounting holes at top and bottom, as shown. 2 IL591 Tek-SAFE Area of Rescue Assistance Manual Copyright TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

System Installation Installation Procedure Equipment Locations Wiring Installation Housing Installation Determine equipment locations. Install wiring. Install housings. Check wires. Connect equipment. Check connections. NC150R Master Station: Locate NC150R Master Station in building lobby within easy reach of operating personnel. Do not exceed operating temperature of 10 30 C. IR150B, IR150N, IR150SS, IR150SS/S Remote Call Stations: Locate IR150B, IR150N, IR150SS, IR150SS/S Remote Call Stations in protected area of rescue assistance locations. Up to 8 remote call stations are supported by each NC150R Master Station. Do not exceed operating temperature range of 10 40 C. The IR150SS includes weather stripping and a Mylar speaker for weather resistance, and may be mounted in areas that are exposed to weather effects (outdoors but under an overhanging roof), but not in areas directly exposed to weather (driving rain with no coverage). PK151A, PK152 Power & Control Units: Locate the PK151A or PK152 and the SS106 within an IH151N Junction Box in an accessible area. (The junction box, transformer and power & control unit are also available preassembled from the factory as part number IH151NK.) Do not exceed operating temperature range of 10 30 C. Location should provide for convenient cable runs to remote call and master stations. Cable run from the PK151A or PK152 to the NC150R Master Station must not exceed 100'. The necessary wiring information can be found in Figure 7. Run wiring conduit from remote call station to remote call station and terminate at the PK151A or PK152 Power & Control Unit. Limit each run to 16 stations and 600 feet of wire. NC150R Master Station: To flush wall mount, provide wall cutout as shown in Figure 2. Remove panels from frame as shown in Figure 3. Fit back box and frame assembly into prepared opening. Fasten assembly into place using screws provided in back box. Housing must be TekTone OH150. Replace panels using the procedure as shown in Figure 3. IR150B Remote Call Stations: Install the back box (Steel City #H3BD with Steel City #3GC plaster ring or exact equivalent) as shown in Figure 4 for each station in system. If a smaller back box is desired, use ARCO #2GB with ARCO #3GC ring. Minimum dimensions of the back box must be no less than 8.6" 4.5" 2.5". Minimum clearance from live parts on the station to dead metal parts must be no less than 0.5". IR150N Remote Call Stations: Install a TekTone IH106N back box horizontally for each station in system. IR150SS Remote Call Stations: Install a TekTone OH600 back box horizontally for each station in system. IR150SS/S Remote Call Stations: No back box is necessary to surface mount. PK151A or PK152 Power & Control Unit, SS106 24 VAC 30 VA Transformer, IH151N Junction Box: Fasten IH151N Junction Box to wall using suitable fasteners. Mount PK151A or PK152 inside junction box. Minimum dimensions of junction box must be no less than 12" 12" 4". Minimum clearance from live parts to dead metal parts on housing must be 1". Install SS106 Transformer in junction box as shown in Figure 5. Do not connect transformer primary to power source until entire installation is completed and checked for shorts and grounds. Install transformer connection box as shown in Figure 5. Minimum dimen- Copyright TekTone Sound & Signal Mfg., Inc. All Rights Reserved. IL591 Tek-SAFE Area of Rescue Assistance Manual 3

System Installation sions must be no less than 1.75" 3.75" 1.5". The junction box, transformer and power & control unit are also available preassembled from the factory as part number IH151NK. Wire Checkout Wire Connections Connections Checkout System Test Instructions Use an ohmmeter or other continuity checking device to test wires for shorts or grounds. If shorts or grounds are encountered, find and correct the problem before continuing. Make sure minimum number of conductors needed for all of the equipment being used in the system are available. Use crimp-style connectors for all wire connections. Do not use wire nuts. NC150R Master Station: Connect wires as shown in Figure 7. IR150B, IR150N, IR150SS, IR150SS/S Remote Call Stations: Connect wires as shown in Figure 7. PK151A or PK152 Power & Control Unit: Connect wires as shown in Figure 7Also connect secondary from the SS106 Transformer (24 VAC, 30 VA connections) to the PK151A or PK152 as shown in Figure 7. Do not connect transformer primary to power source until entire installation is completed and has been checked for shorts and grounds. Recheck all connections to equipment. If all wires and connections are satisfactory, connect primary coil of SS106 Transformer to source of 117 VAC 60 hz (40 watts max.) and operation of system can be checked according to System Test Instructions. Before proceeding with a system test, set all stations to normal conditions as follows: NC150R Master Station: All push buttons should be in the out position. A depressed button may be released by pressing the button and then releasing it. IR150B, IR150N, IR150SS, IR150SS/S Remote Call Stations: If the call placed lamp is illuminated, press the RESET button to reset it. Test IR150B, IR150N, IR150SS, IR150SS/S Remote Call Stations: Test remote call stations one at a time. Press the CALL button on each remote call station to place a call. Check for operation of the following signals: Figure 5 SS106 Transformer Installation Figure 6 NC150R Selector Lamp/Switch Lens, Filter and Lamp Replacement 1 Lens 2 Filter 3 24V Lamp 4 Switch Knob 1 2 3 4 4 IL591 Tek-SAFE Area of Rescue Assistance Manual Copyright TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

System Installation The call placed lamp on the remote call station should be illuminated. On the NC150R Master Station, the CALL lamp should be illuminated and the associated station selector lamp (marked to identify the calling station) should be illuminated. A slowly repeating audible call tone should be heard. Press the RESET button on the remote call station to reset the call. All signals should be canceled. Test the Intercom Function: Press the CALL button on the remote call station to place a call. At the master station, select the calling station by pressing the illuminated station selector button, and check for the following: The station selector lamp should be canceled. The CALL lamp should turn off. The audible call tone should be canceled. The remote call station s in use LED should be illuminated. Press the CALL button and the TALK button on the master station. An electronic call tone should be heard at the master station and at the remote call station. Press the TALK button and speak in a normal voice. Release the button to hear the reply. At the remote call station, the call placed lamp should turn off, and the in use LED should be illuminated. When voice communication is heard, reply in a normal voice. Return all controls to the normal position. Figure 7 Tek-SAFE System Wiring Diagram NC150R Master Panel NC150R Control UN XLXL J E C DPP1 Selector Switch Module X XLXLX LXL Selector Switch Module L XL Notes: 1. Terminal identifications shown are not in actual order. 2. Main supply circuit: Connect to 117 VAC, 60Hz, 40 Watts maximum. Use #18 gauge wire. 3. Use shielded cable if not in a metal conduit. If shielded cable is used, shield drain wire replaces conductor connected to terminal C on CONTROL module on NC150R. Connect shields from twisted shielded pairs to C terminal on master. #22 PK151A / PK152 J D R R P P T1 T2 N N Q Q E #18 #18 #18 SS106 IR150B, IR150N, IR150SS, IR150SS/S Yellow (R) Brown (P) Blue (C) Orange (L) Red (Y) Green (X) IR150B, IR150N, IR150SS, IR150SS/S Yellow (R) Brown (P) Blue (C) Orange (L) Red (Y) Green (X) Typical of up to 8 stations maximum 24 VAC 117 VAC 1 Twisted Shielded Pair #22 1 Twisted Shielded Pair #22 IL591 NC150R Wiring Rev5 100510 1 Copyright TekTone Sound & Signal Mfg., Inc. All Rights Reserved. IL591 Tek-SAFE Area of Rescue Assistance Manual 5

System Maintenance Instructions Most of the equipment and parts used in the NC150R Area of Rescue Assistance System are not user serviceable and cannot be replaced or repaired by the end user. Equipment must be repaired by qualified service personnel only. There are no user serviceable parts in the PK151A and PK152 Power & Control Units or the IR150B, IR150N, IR150SS, IR150SS/S Remote Call Stations notify qualified service personnel for repair or replacement. Parts which are user serviceable are listed in the following section and their replacement explained. NC150R Master Stations Replacement Parts There are several user serviceable parts in the NC150R Master Stations. Only one of these parts is electrically operated. The user serviceable parts and replacement procedures are explained below. Refer to Figure 6 to identify replacement switch parts. A full list of replacement parts and numbers appears in the Replacement Parts section. Selector Lamp/Switch Lens Replacement: Remove lens by squeezing top and bottom together and pulling away from panel. Replace with same color lens by pushing new lens towards panel. The lens should snap into place on the selector lamp/switch knob with a noticeable click. Selector Lamp/Switch Filter Identification: Remove lens by squeezing top and bottom together and pulling away from panel. Remove white filter by lifting it out of selector lamp/switch knob. Identify filter by room number or other means using dry transfer lettering, labels, or other similar methods. Be sure identified filter is replaced in knob so that lettering is readable right side up. Defective Lamp Replacement: Remove lens and filter by method described above. Using needle-nosed pliers, tweezers or similar tool, pull lamp out of socket by gripping lamp at sides and moving it from side to side as it is pulled away from the panel. WARNING: Do not squeeze too tightly, or it will break. Replace lamp by holding with tool and pushing into socket. Be sure lamp is turned so that the base is lined up with the slot in the socket. Lamp must be pushed in below the level of the filter. Push test button to make sure lamp has been placed in socket properly. If lamp does not light, try pressing more firmly into socket. If lamp still does not light, repeat steps above with new lamp until one works properly. Replace lens and filter in lamp/switch knob as previously described. Part No. Description Used For LI014K 24V Lamp, 10 each NC150R Selector Module Lamps RP021K Blank Filter, 10 each NC150R Selector Button Label RP022K Orange Lens, 10 each NC150R Call and Selector Buttons RP024 Green Lens, 1 each NC150R Talk Button RP027K Clear Lens, 10 each NC150R Button (not used) RP028 Yellow Lens, 1 each NC150R Button (not used) 6 IL591 Tek-SAFE Area of Rescue Assistance Manual Copyright TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

Copy this Users Guide and place it next to the NC150R Master Station. This page will fit in a standard 8" 10" frame when cut on the dotted lines. Users Guide for Tek-SAFE Area of Rescue Assistance System IL591 - Page 7 Rev. 12-03/2011 NC150R Master Station IR150SS, IR150SS/S Remote Call Station 8 5 IR150B Remote Call Station 6 4 3 1 2 1 Call Button: Tone call to selected remote when pressed. Call Lamp: Indicates incoming call when illuminated. 2 Talk Button: Talk when pressed. Listen when released. 3 Selector Buttons: Establishes conversation path with associated remote station when depressed. Selector Lamps: Indicates incoming call from associated remote when illuminated. 4 Call Button: Places a call when pressed. 5 Call Placed Lamp: Indicates a call is placed when illuminated. 6 Reset Button: Cancels the call when pressed. 7 In Use LED: Indicates station is in use when illuminated. 8 Audio On Lamp: Indicates master station is listening when illuminated. IR150N Remote Call Station 8 AUDIO 6, 7 4, 5 4 6 5 NC150R MASTER STATION OPERATION Answer a Call: Normal calls are indicated by simultaneous operation of the following signals: Steady illumination of the associated station selector lamp which is marked to indicate call origin, steady illumination of call lamp, and slowly pulsing audible tone. To establish conversation with the calling station, press the associated station selector button. The remote station s in use LED will illuminate. To speak to the caller, press the TALK button while speaking and release to listen. When the conversation is complete, press the associated station selector button to release the station. The remote station s in use LED will turn off. Call a Remote Call Station: Locate the station selector button associated with the remote station to be called. Press that selector button to establish a conversation path. The remote station s in use LED will illuminate. To produce an announcing tone at the remote station, press the TALK and CALL buttons simultaneously. Press the TALK button while speaking, and release button to listen. The remote area may be monitored by selecting the remote station and releasing the TALK button. When conversation or monitoring is complete, press the station selector button to release it. The remote station s in use LED will turn off. Test Station Selector Lamps: Press TEST button. All station selector lamps should illuminate. IR150B, IR150N, IR150SS, IR150SS/S REMOTE STATION OPERATION Call the NC150R Master Station: Press the CALL button. The call placed lamp will illuminate to indicate call placement. When the call is answered, the call placed lamp will go off and the in use LED will illuminate to indicate a communication path has been established to the master station. Speak in a normal voice. Cancel a Call: Press the RESET or CANCEL button. Call placed lamp will go off. Copyright TekTone Sound & Signal Mfg., Inc. All Rights Reserved. IL591 Tek-SAFE Area of Rescue Assistance Manual 7