DRAFT. Proposal to modify International Standard IEC

Similar documents
Product testing and evaluation to IES LM-79-08

DCI Memorandum Regarding Direct View Displays

BUREAU OF ENERGY EFFICIENCY

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

LM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Fuel Pump Canopy Luminaires

Photometric Test Report

User requirements for a Flat Panel Display (FPD) as a Master monitor in an HDTV programme production environment. Report ITU-R BT.

DCI Requirements Image - Dynamics

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For CE INNOVATIONS LTD. (Brand Name: IRICO) 911 Denison St Markham, ON L3R 3K4 Canada

Christie MicroTiles. Technical Frequently Asked Questions (FAQs)

ENERGY STAR Program Requirements Product Specification for Televisions. Eligibility Criteria Draft 1 Version 6.0

Calibration of Colour Analysers

NVLAP LAB CODE LM Test Report. For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A)

Display Quality Assurance: Recommendations from AAPM TG270 for Tests, Tools, Patterns, and Performance Criteria

Display Quality Assurance: Recommendations from AAPM TG270 for Tests, Tools, Patterns, and Performance Criteria

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

Measurement of Microdisplays at NPL

Selected Problems of Display and Projection Color Measurement

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

ENERGY STAR Program Requirements Product Specification for Televisions. Eligibility Criteria Version 5.3

NVLAP LAB CODE:

ENERGY STAR Program Requirements Product Specification for Displays. Final Test Method Rev. Sep-2015

LightLab I N T E R N A T I O N A L

LED Floodlight RoHS. Model: inner box: L273*W240*H165mm master carton: L549*W485*H175mm 4PCS

GORDON WATSON and ASSOCIATES

LightLab I N T E R N A T I O N A L

LaCie 321 LCD Monitor

DISPLAY WEEK 2015 REVIEW AND METROLOGY ISSUE

NVLAP LAB CODE LM Test Report. For. EiKO Global, LLC. (Brand Name: EiKO) W. 84th St, Shawnee, KS USA

ENERGY STAR Program Requirements Product Specification for Televisions. Draft Test Method

PT-LB300 S P E C F I L E. LCD Projectors. As of April Specifications and appearance are subject to change without notice. 1/8.

PHONE: (303) FAX: (970) WEBSITE:

Photometric Test Report

PT-LW330 S P E C F I L E. LCD Projectors. As of April Specifications and appearance are subject to change without notice. 1/9.

NVLAP LAB CODE:

crystal radio receiver 1921

An Introduction to TrueSource

MANAGING HDR CONTENT PRODUCTION AND DISPLAY DEVICE CAPABILITIES

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

INTERNATIONAL STANDARD

Background Statement for SEMI Draft Document 5291A New Standard: TEST METHOD OF AMBIENT COLOR GAMUT FOR FPD UNDER INDOOR ENVIRONMENTS

INSTALATION PROCEDURE

ZipTwo LED - Zipper board with Diffuse Batwing Lens, High Output. IES File Performance Summary

PLV-Z2 ROLL THE FILM FOR THE FUTURE!

Number Eight Lighting Company 526 Portal Street, Cotati, CA 94931

specification hyperion colorimeter

PROJECTORS BRADLEY BRANAM

specification hyperion colorimeter

PT-LB385 S P E C F I L E. LCD Projectors. As of December Specifications and appearance are subject to change without notice.

Remote Director and NEC LCD3090WQXi on GRACoL Coated #1

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

PT-LB382 S P E C F I L E. LCD Projectors. As of July Specifications and appearance are subject to change without notice. 1/9.

Product Number : LB303 Product Name : As of October Specifications and appearance are subject to change without notice.

XC-77 (EIA), XC-77CE (CCIR)

WLC60 Heavy Duty LED Light - PWM Dimmable

General viewing conditions for subjective assessment of quality of SDTV and HDTV television pictures on flat panel displays

3/2/2016. Medical Display Performance and Evaluation. Objectives. Outline

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

Bartco Lighting 5761 Research Drive, Huntington Beach, CA

Secrets of the Studio. TELEVISION CAMERAS Technology and Practise Part 1 Chris Phillips

Methods for the Measurement of the performance of Studio Monitors

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

Osram Sylvania 200 Ballardvale Street Wilmington, Mass

Product Number : LW373 Product Name : As of October Specifications and appearance are subject to change without notice.

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

Common assumptions in color characterization of projectors

Lecture 2 Video Formation and Representation

FNP3 Series Tri-Lens for Nichia NS6x083 and NS6x183 LEDs

specification MSE series MSE and MSE+ colorimeter

Using Low-Cost Plasma Displays As Reference Monitors. Peter Putman, CTS, ISF President, ROAM Consulting LLC Editor/Publisher, HDTVexpert.

Measurement of automatic brightness control in televisions critical for effective policy-making

Qualifying Criteria Versions 4.1 and 5.1

Company Software Manual version Issued Date Sony Corporation Projector Calibration Pro Version 0.04 Mar 3rd, 2017

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU

Remote Director. Apple 23 LCD Display. Collaborative Soft Proofing using the I. MANUFACTURER INTRODUCTION. SWOP Application Data Sheet

The Extron MGP 464 is a powerful, highly effective tool for advanced A/V communications and presentations. It has the

Fixture is tested with no special conditions. No seasoning was performed in accordance with IESNA LM-79. PS-AC02 CD-SN03-S2 MT-SC01-S2 2MR97 SPR-3000

FS3 Series Tri-Lens for SEOUL SEMICONDUCTOR Z-POWER P4 TM LEDs

SIM2 NERO4 PLATFORM/ 4K HDR at its best! We work for Excellence

Using the VP300 to Adjust Video Display User Controls

PRODUCT NO.: PT-L735 PRODUCT NAME: Ultra Portable LCD Projector

White Paper. Uniform Luminance Technology. What s inside? What is non-uniformity and noise in LCDs? Why is it a problem? How is it solved?

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

RECOMMENDATION ITU-R BT (Question ITU-R 211/11)

CHAPTER 2. Black and White Television Systems

LMT X1 - a 12.1" VHB

Computer Graphics Hardware

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

Remote Director. EIZO ColorEdge CG21. Collaborative Soft Proofing using the I. MANUFACTURER INTRODUCTION. SWOP Application Data Sheet

for Television ---- Bit-Serial Digital Interface for High-Definition Television Systems Type FC

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. INFINILINE X 120V LED Light DI-120V-INFX60

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. INFINILINE X 120V LED Light DI-120V-INFX27

SIM2 CRYSTAL4 PLATFORM Perfect balance of HDR power, precision and innovation. We work for Excellence

Number Eight Lighting Company 803/K2-HI-25-XX/DIM /FS-P-1-WH

Transcription:

Imaging & Color Science Research & Product Development 2528 Waunona Way, Madison, WI 53713 (608) 222-0378 www.lumita.com Proposal to modify International Standard IEC 61947-1 Electronic projection Measurement and documentation of key performance criteria Part 1: Fixed resolution projectors December 30th, 2007 DRAFT

Introduction This document outlines a proposal to modify IEC 61947-1 Electronic projection Measurement and documentation of key performance criteria Part 1: Fixed resolution projectors Specifically the proposal is a change to Section 5 Light output measurement. The current standard measurement for projector brightness is IEC illuminance often misrepresented on projector datasheets as ANSI lumens. The ANSI specification was withdrawn (in 2002) and the international standard IEC 61947-1 replaced it. The IEC illuminance specification is a key performance metric for the comparison of light output. Consumers use this specification as a primary metric when making purchase decisions. Historically this metric has been clearly indicative of projector performance. Recently new projector technologies have significantly distorted the performance of this metric and depreciated it s utility as a fair comparison of total image brightness. The current specification samples a grid of test points on a white field and uses an average of those measurements multiplied by the projected area to arrive at the result. Historically projectors used, and primaries to create the white field, matching the method used in the (RGB) input signal. The measured white field was the sum of the color primaries individual luminance, as such the IEC illuminance specification clearly represented how bright any individual image or scene on one projector would appear compared to another. Recent development in some projector technologies has seen the addition of more than three primary colors and in some cases the addition of a white primary. In some of these projectors the luminance of the red, green and blue primaries do not add up to the luminance of white. In fact the white of the projector may exceed the luminance of RGB by more than 50%. Because of this discrepancy the IEC illuminance specification no longer represents the overall brightness of the projected color Image. A full color image on a 1500 lumen projector that utilises a white primary may look darker than the same image on a 1000 lumen RGB projector. RGB not suming to white can also create a significant perceptual distortion of color photographic images. [Heckamen, Fairchild - Journal of the SID 14/9, 2006] The luminance of white continues to be an important metric and no change in the current White Illuminance specification is proposed. When the projector will mostly be used to display black or white text, white luminance is significant. However, if the projector will be used to display color imagery, the existing metric fails to represent actual performance and misleads the consumer. To remedy this failure an additional metric is proposed. This metric would be called Color Illuminance. The Color Illuminance specification would be required alongside the White Luminance specification. IEC White Illuminance 1800 lumens @ 6500K IEC Color Illuminance 900 lumens @ 6500K The Color Illuminance of a projector is the total illuminance of the maximum red, green, and blue input signal measured independently and then added together. As the input color encoding for all these projectors are based on RGB primaries, this new metric clearly represents the expected perceptual luminance of color images on the subject projector. [Lang, Proceedings of the 15th Color Imaging Conference, 2007] 2

Section 5, Proposed Modification - IEC 61947-1: 5 Light output measurement and specification The light output specification shall be stated in lumens for projectors with separate screens, and in candela per square metre (nits) for displays with self-contained screens. The following conditions shall be met: input signals shall be supplied by a standard test signal source, as specified in Annex B; the pixel resolution of the input signal for light output measurment shall match the native resolution of the projector. If the projector has digital signal inputs this input and signal type should be used. the light meter shall be photopically and cosine corrected, calibrated, and traceable to a national standard; a special test pattern (see Figure A.1) shall be used to set the controls for making measurements. The black level (or brightness control) shall be set to the point where the maximum number of signal level blocks on the top line, representing 0 %, 5 %, 10 % and 15 % signal levels, are visible and distinct from the adjacent signal level blocks. The video gain (contrast or picture control) shall be advanced from minimum until the maximum number of signal level blocks in the lower line of the pattern, representing the 85 %, 90 %, 95 %, and 100 % signal levels, are visible and distinct from the adjacent signal level blocks, or until the picture no longer increases in brightness as limited by automatic brightness circuitry. In the event of controls interacting, they shall be readjusted in sequence in order to achieve the described conditions on the screen. The controls shall remain at these settings for all measurements. The total number of signal level blocks distinguishable in this pattern shall be stated in the specification. A 100 % full white image shall be used for the correlated colour temperature (CCT) and white screen illuminance measurements, immediately following with no changes to the projector settings, the color illuminance measurment shall be performed using test targets 4, 5 and 6 in annex A. For display devices where the screen is not an integral part of the viewing system, the CCT shall be measured by placing a cosine corrected colorimeter in the plane of the focused image. For display devices the screen of which is an integral part of the projection device, the CCT shall be measured by focusing a colorimeter at the centre of the screen. The measurement field shall be at least 3 pixels by 3 pixels. The projection system shall be adjusted until the desired CCT is obtained. The equipment shall be stabilized without further adjustment for at least 15 min before making any colour or other measurement. All measurements shall be made in a darkened room. Light from the projector shall be measured with a photopically corrected, cosine corrected light-meter, the calibration of which is traceable to a national standard. Note: Meters may suffer from errors due to such problems as spectral mismatch of tristimulus filters. Also, scanning or pulsed source displays may saturate the meter. For diagnostics, solutions, and further information concerning light meters, see Annex H. For display devices where the screen is not an integral part of the viewing system, the white illuminance shall be measured with a light meter, the sensor of which is placed in and parallel to the plane of the focused image at the centre of each of nine equal rectangles and four corners (see Figure A.2) or the detector can be placed at the viewing space design centre. The measurement field shall be at least 3 pixels by 3 pixels. The average of the nine white field readings in lux (lumens per square metre) shall be multiplied by the number of square metres covered by the image at the plane of the meter readings. The result shall be taken as the white light output of the projector, in lumens. For display devices where the screen is not an integral part of the viewing system, the color illuminance shall be measured with a light meter, the sensor of which is placed in and parallel to the plane of the focused image at the centre of each of nine equal rectangles (see Figure A.2) or the detector can be placed at the viewing space design centre. The nine measurerment points shall be sampled for each of the three color illuminance test targets (see Figure A.4, A.5, and A.6) 3

The average of the 9 red measurements in lux plus the average of the 9 green measurements in lux plus the average of the 9 blue measurements in lux shall be multiplied by the number of square meters covered by the image at the plane of the meter readings. The result shall be taken as the projectors color light output, in lumens. The light output specification shall also state the aspect ratio of the display, horizontal and vertical scan rates, CCT and the lens throw distance ratio and type. For display devices where the screen is an integral part of the projection device, the white luminance of the screen is measured in candela per square metre (nits) at the centre of each of the nine equal rectangles (see Figure A.2) or the detector can be placed at the designed viewing distance. The standard viewing distance shall be four times the screen height and the standard viewing angle shall be selected as the peak angle in order to obtain the maximum luminance of the white picture at the centre of the screen. White Luminance shall be measured for nine zones. The measurement field shall be at least 3 pixels by 3 pixels. An average of the nine readings shall be taken in order to calculate the light output specification, in candela per square metre (nits). For display devices where the screen is an integral part of the viewing system, the color luminance of the screen is measured in candela per square metre (nits) at the centre of each of the nine equal rectangles (see Figure A.2) or the detector can be placed at the designed viewing distance. The nine measurerment points shall be sampled for each of the three color illuminance test targets (see Figure A.4, A.5, and A.6) The average of the 9 red measurements in cd/m 2 plus the average of the 9 green measurements in cd/m 2 plus the average of the 9 blue measurements in cd/m 2 shall be taken as the projectors color light output, in cd/m 2. 5.1 Light output specifications 5.1.1 Light output specification for projectors with a separate screen White illuminance and color illuminance specificatiions shall always be provided together. EXAMPLE Light output measurement conditions: 6500 K CCT, 4:3 aspect ratio, and a 2:1 lens; IEC White illuminance 1800 lumens IEC Color illuminance 900 lumens 5.1.2 Full black light level specification Measurements shall be made at the same signal level as the black rectangles for contrast ratio measurement (see Figure A.3). EXAMPLE Full black light level: 1.2 lumens 5.1.3 Luminance specification for devices with an integral screen EXAMPLE Luminance measurement conditions: 9300 K CCT, 4:3 aspect ratio, and a total screen viewing angle of 60 horizontal, 20 vertical (higher luminance values are better): IEC White luminance 175 cd/m 2 IEC Color luminance 120 cd/m 2 Note: Direct comparisons can be made between displays with and without integral screens using candela per square metre, if both screens have the same horizontal and vertical angles of view. If this is not the case, mathematical conversions may be made, but will result in unreliable data of questionable value. 4

Additions to Annex A: Test Pattern A.4 Test Pattern A.5 5

Test Pattern A.6 Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Zone 9 Figure A.7-9 point measurement grid for illuminance testing. 6