Powerhouse Theatre technical information and general specifications 2017

Similar documents
Visy Theatre technical information and general specifications 2019

Auditorium Seating VISY THEATRE TECHNICAL SPECIFICATIONS

VISY THEATRE TECHNICAL SPECIFICATIONS Version 2.6 3/7/2013. Auditorium Seating. Page 1 of 4 STAGE CONFIGURATIONS

Dubbo Regional Theatre & Convention Centre Theatre Technical Specifications

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

DEREHAM MEMORIAL HALL

Theatre Technical Specifications

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

There are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated.

2017 TECHNICAL SPECIFICATIONS

RPAC REDLANDS PERFORMING ARTS CENTRE

CENTRE FOR PERFORMING ARTS

BURDEKIN THEATRE BURDEKIN THEATRE. Technical Specifications. Updated 08/02/2008

Matt Dann Cultural Centre

Technical Data Sheet

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

Queensland Performing Arts Centre

TECHNICAL SPECIFICATIONS

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

Hopgood Theatre NOARLUNGA CENTRE

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

TOWER THEATRE TECHNICAL INFORMATION & GENERAL SPECIFICATIONS 2014 PLEASE DIRECT ALL ENQUIRIES TO THE OPERATIONS MANAGER:

Technical Specification Pavilion Dance

John Leslie Theatre. Technical Specifications. Updated July 2018

Dr JOHN GALLAGHER CONCERT CHAMBER

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

Sandusky State Theatre Technical Specifications

THE STREET THEATRE. Technical Specifications

HIRE AND TECHNICAL INFORMATION

Technical Specifications

JERWOOD VANBRUGH THEATRE

Arcadia Performing Arts Center Technical Specifications and Information

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

New Theatre Royal Lincoln Technical Information

ISLAND HALL TECHNICAL INFORMATION

MONASH University Academy of Performing Arts

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

Technical Pack. Attenborough Arts Centre

BECKETT THEATRE TECHNICAL INFORMATION & GENERAL SPECIFICATIONS 2014 PLEASE DIRECT ALL ENQUIRIES TO THE OPERATIONS MANAGER:

Stage point load limit: Stage point load of 700kg. Stage dimensions Non-proscenium stage. Setting line 200mm upstage from the fire curtain.

Main House Technical Specification

Auditorium: 16m x 24m (including stage area) Variable acoustics to suit different performance types

Alexander Theatre. Technical Specifications. Monash University VIC enter via Wellington Road

Darlington Hippodrome Technical Specification

UNIVERSITY CONCERT HALL. Technical Specification

Technical specifications Main theatre. Sound

SOUND. * All instruments and circuits have standard 2 pin and ground stage pin connectors. Page 1 of 5

Latrobe Performing Arts Centre

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

1400 MARKET STREET ST LOUIS, MISSOURI Main Number Main Fax

Technical requirements & conditions for hirers

Technical Specification

Technical Specification for the Alley Theatre, Strabane

332 fixed seats (max capacity) with reserved space for disable access

Monash Academy of Performing Arts (MAPA) Alexander Theatre. Technical Specifications

Technical Specifications

Esso BHP Billiton Wellington Entertainment Centre

Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black)

Technical Information

Faris Family Studio at the Dance Centre, Vancouver BC 677 Davie Street, Vancouver, British Columbia. V6B 2G6

Marjorie S. Deane Little Theater

Hopgood Theatre NOARLUNGA CENTRE

Technical Specification (Studio Theatre)

Main House Technical Specifications

Stage point load limit: Stage point load of 700kg. Stage dimensions Non-proscenium stage. Access door to stage from scene dock - 2.9m by 2.9m.

The performance is about 100 minutes long, excluding intermission. ACT 1 is 75min, ACT 2 is 20min. Intermission 20-25min.

Technical Director of Production Andrew Quick Ext 252

Theatre Technical Specifications

TECHNICAL RIDER. A full-scale diagram of the theatre can be downloaded at

Technical Information

Shouson Theatre Venue Specifications (updated Jan 2017)

T1 National Theater. Auditorium (Basement 1): 324 Under Balcony (Ground floor): 388 Royal Circle (Level 1): 161 Level 2: 316 Level 3: 422

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

Technical Specification. Updated: April 2016

Pleasance London Main House Visiting Company Information Pack May 2017

* All public events require the presence of Centerville High School Security. Contact Theatre Manager for details.

Scheman Building Suite 102, 1805 Center Drive, Ames, IA Fax Number: Website:

The Haymarket Basingstoke Technical Specifications

BANYULE THEATRE TECHNICAL INFORMATION. 10 Buckingham Drive Heidelberg VIC Page 0 of 10

ROSE THEATRE BASEMENT

TECHNICAL RIDER. STAGE 32 m wide x 13 m deep (from setting line / mid point)

Technical Specifications

MAJESTIC (Circus Tent)

Technical Specifications

Monash Academy of Performing Arts

Technical Specification (Studio Theatre)

Monash University Academy of Performing Arts

Technical Services and Specification

Main Stage Technical Specs - Hall #2

TECHNICAL SPECIFICATIONS RIVERSIDE THEATRE

Technical Specification

MERMAID ARTS CENTRE. Outline Technical Specifications as of 17 th January 2018.

Phil L. Thomas Performing Arts Center Shiprock, New Mexico

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.

DUNSTAN PLAYHOUSE TECHNICAL SPECIFICATIONS

Venue details. Stage Dimensions. Stage section Width Depth Height to Grid. Main Stage 8.8m (ex. wings) 7.32m 8.1m Baptistery 7.19m 6.4m 8.

Yan Yean Theatre Technical Specifications

ICM Internationales Congress Center München DETAILS ROOM 14 including technical specifi cations and seating variants

Technical Specifications

Transcription:

Powerhouse Theatre technical information and general specifications 2017

General Information THEATRE ACCESS Artist access to the Powerhouse Theatre is via either the stage door, the lower loading dock or through the theatre doors in the foyer. DRESSING ROOMS Three dressing rooms are available to Hirers of the Powerhouse Theatre. Two are at stage level and another is located one level above next to the green room. All dressing rooms have toilets and showers. GREEN ROOM The Green Room is located one level above the stage. It is available for all staff to use and on occasion doubles as a meeting room. There is an urn on the wall and a fridge for general use. AIR CONDITIONING The Powerhouse Theatre and its associated dressing rooms are air-conditioned. DISABLED ACCESS The stage of the theatre is at foyer level and is accessible by disabled persons. Any additional requirements should be communicated to the Technical Services Department. LAUNDRY FACILITIES Basic laundry facilities are available with prior arrangement. Limited hand sewing tools are available for wardrobe repairs, but no sewing machinery is available. SMOKING The Brisbane Powerhouse is a non-smoking venue. By law smoking can only take place only in Designated Smoking Areas. INSURANCE Details of insurance are provided with the venue contract. RUBBISH All Hirer rubbish must be removed from the theatre and dressing rooms at the conclusion of bump out. A small amount of rubbish can be disposed of in the venue bins but excess usage will incur charges. PRODUCTION MEETINGS Production meetings between Brisbane Powerhouse Technical staff and the Hirer may be requested to determine production requirements. TECHNICAL STAFF Brisbane Powerhouse requires a minimum of two technical staff to be present when the Hirer is in the Powerhouse Theatre. Brisbane Powerhouse may determine additional technical staff are necessary dependent on production requirements. AWARD CONDITIONS All technical staff at Brisbane Powerhouse work under the conditions of the Live Performance Award 2010. It is the responsibility of the Hirer to be familiar with the conditions of the Award. Brisbane Powerhouse can supply the Award on request. WORKPLACE HEALTH AND SAFETY The Hirer shall ensure safe work practices are adhered to by their staff and defer to the venue staff if there is a question of safety and/or damage to the venue or equipment. All visiting Hirers including cast and crew must undergo a venue specific induction in regard to fire evacuation and workplace health and safety. A copy of the Brisbane Powerhouse fire evacuation procedure is available on request. It is a requirement of Brisbane Powerhouse that closed shoes be worn on stage for all site inspections, bump in and bump out. All electrical equipment entering the building must carry the appropriate test and tag documentation. Every Hirer must provide Brisbane Powerhouse with appropriate risk assessment documentation. HEIGHT SAFETY Height safety equipment as required is provided as part of the venue hire. Hirer staff must be inducted if its use is required. All staff doing work that requires a harness must have working at heights certification and use a harness and head protection. POWERHOUSE THEATRE TECHNICAL INFORMATION AND GENERAL SPECIFICATIONS 2017 01

RIGGING OVERHEAD All rigging is at the discretion of the Technical Director and the Head of staging. LOADING ACCESS Brisbane Powerhouse has two loading dock facilities. For rear loading trucks and vehicles, the lower loading dock is accessible from the car park and provides access to the Powerhouse Theatre via a lift from the ground floor. Please see below for access dimensions. The upper loading dock, accessible by prior arrangement with Brisbane Powerhouse, provides direct stage access to the Powerhouse Theatre for rear loading trucks and vehicles. The upper loading dock can accommodate a 40 semi-trailer. A forklift is available via prior arrangement with Brisbane Powerhouse for side loading trucks. Please see below for dimensions. Upper Loading Dock: Door width: 3.2m Height clearance: 5.5m Loading height: 0.7m 2.0m Table lift capacity: 2000kg Lower Loading Dock: Door clearance: 2.7m x 3.5m (W x H) Vehicle clearance height: 3.7m Corridor clearance: 1.76 x 2.73 (W x H) Loading height: Ground Lift to Stage Level: Door width: 1.3m Door height: 2.0m Internal: 1.5m x 2.3m x 2.17m (W x D x H) Capacity: 1700 Kg EQUIPMENT DELIVERY All production related deliveries must be itemised and all details such as hire company and delivery times should be given to the appropriate Technical Services staff prior to bump in. All equipment must have the suitable number of people to unload it. All equipment must be removed following the final performance. Anything left at the venue for more than half a day may incur charges. NOISE LEVELS The Powerhouse Theatre noise levels are limited to 110db (C). The levels are measured 3 meters from the source with the db meter in C weighting and fast response. ASSISTED LISTENING SYSTEM The venue is equipped with an UHF assistive hearing system for patrons. Headsets are collected by patrons from box office as needed. FIRE SERVICES Use of a smoke machine, hazer, aerosolised paint, metal cutting tools, or anything that is likely to trigger the venue smoke detectors will require the alarm system to be isolated. The isolation can only be performed by appropriate venue staff. On occasion additional venue staff may be required ensure adequate fire monitoring. Any charges arising from false alarms, including the cost of Fire Brigade attendance are the responsibility of the Hirer. ACCESS EQUIPMENT AND LADDERS Brisbane Powerhouse has a range of ladders and height access equipment available. Hirer use of this equipment is at the discretion of Brisbane Powerhouse Technical Services staff and will require an induction in its use. WORKSHOP FACILITIES Brisbane Powerhouse has a small workshop and basic tools available for Hirers to use at the Technical Directors discretion. STAGE MANAGEMENT SYSTEM The Stage Managers Desk (SMD) is located prompt side. The system has full paging and relay to the dressing rooms attached to the Powerhouse Theatre. As part of the venue hire, single channel wired comms packs are provided at the SMD, sound desk and lighting desk. Additional comms are available for hire if required. It also features an in-built cue light system and stage monitor. PIANOS The following pianos are available for hire 1 x Yamaha 52 key Upright piano 1 x 5 1 Boston 52 key Baby Grand piano POWER Brisbane Powerhouse works on a distributed dual earth power system. 40 amp 3 phase outlets are distributed throughout the theatre. A reasonable supply of 240v leads are available within the space. The audio system operates on an Uninterruptable Power Supply (UPS) to condition the power and is on a separate earth to regular mains power. POWERHOUSE THEATRE TECHNICAL INFORMATION AND GENERAL SPECIFICATIONS 2017 02

Venue Layouts The Powerhouse Theatre is a studio style space with a variety of stage and seating configurations. The venue is supplied in the standard layout as part of the standard hire. Listed below are the alternate venue layouts. Any changes from the standard layout will incur a labour cost to reconfigure the space. STANDARD LAYOUT The stage size in Standard mode is approx. 13m x 9.5m (dependent on masking.) Removable Pit Seating 46 Seating bank rows A to P Upper Galleries 379 (restricted viewing) 37 Lower Galleries 32 Balcony 49 Total Capacity 543 DANCE LAYOUT In Dance Mode the pit seating is removed. The stage size is approx. 13m x 12m (dependent on masking and show requirements.) A black harlequin dance floor is available for hire. Seating bank rows A to P 379 Upper Galleries (restricted viewing) 37 Lower Galleries (restricted viewing) 32 Balcony Seating (restricted viewing) 49 Total Capacity 497 CABARET LAYOUT In Cabaret mode the seating bank is partially retracted, the pit seating is removed, and 35 tables are placed on the venue floor in front of the seating bank. The stage size in this mode is 10m x 5m x.8m. Seating bank rows B to I 184 Table seating 210 Upper Galleries (restricted viewing) 37 Lower Galleries 32 Balcony 49 Total Capacity 512 EXTENDED SEATING LAYOUT In extended mode the pit seating is removed and eight rows of chairs are placed on the venue floor. The stage size in this mode is 12m x 4m x 1m. Seating bank rows A to P 379 Flat Floor Chairs 234 Upper Galleries (restricted viewing) 37 Lower Galleries 32 Balcony 49 Total Capacity 731 FLAT FLOOR LAYOUT The seating bank is retracted and pit seating removed to create a large flexible space with multiple stage options. Standing Room 729 Upper Galleries (restricted viewing) 37 Lower Galleries 32 Balcony Seating 49 Total Capacity 847 REDUCED SEATING LAYOUT Seating remains in standard mode, but a curtain is dropped from the balcony level to reduce stalls capacity. Removable Pit Seating 46 Stall Rows A to I 184 Total Capacity 230 THEATRE PLANS Plans and pictures of the venue are available from brisbanepowerhouse.org. CAD drawings are available on request from the Technical Services Department. POWERHOUSE THEATRE TECHNICAL INFORMATION AND GENERAL SPECIFICATIONS 2017 03

Staging Information Staging options in the Powerhouse Theatre are extremely flexible. The Powerhouse Theatre does not have a fly tower or Proscenium. Rigging in the space takes place from I beams which run up and downstage spaced at 2.1m. The grid loading is co-dependent. All rigging must be submitted to Brisbane Powerhouse Technical Services a minimum of 6 weeks prior to bump-in so load calculations can be completed. Along with the equipment listed below additional staging and rigging equipment is available for hire. STAGE FLOOR The stage is a sprung timber dance floor. The top deck is 6mm thick Masonite painted with black low sheen Dulux X10. The floor has a 750kg per square meter distributed load. Screwing into surface is permitted but requires assessment and approval from the Technical Services. RIGGING 5 x fixed catwalks with an upstage and downstage upper and lower lighting bar comprising of 48mm heavy wall steel scaffold pipe Lower lighting bar height is 9.6m to the underside of the pipe Upper lighting bar height is 10.5m to the underside of the pipe 60kg per metre max distributed load on lighting bars 75mm I beams pan the roof from US to DS spaced 2.1m apart and are 11.5m from floor to underside of beam 4 x powered fly bars with a WLL of 300kg 1 x 14m length of 300mm Global tri-truss suspended mid-stage from 2 x 1 tonne chain motors (subject to prior agreement and SWL) 1 x 14m length of 500mm Box truss suspended US from 2 x 1 tonne chain motors (subject to prior agreement and SWL) DRAPES The standard masking in the space consists of: 1 x pair of rear tabs, 8.0m x 9.0m each on track rigged from US box truss (75% fullness) 1 x pair of mid stage tabs, 8.0m x 10.5m on track rigged from motorized bar 4 (75% fullness) 10 x 2.0m x 6.9m flat wool legs (moveable US/DS on Unistrut track.) Basic PS and OP Panorama masking Additional masking is available at the Hirers expense. 1 x 4.6m deep black border (flat) 1 x 2m deep black border (flat) 1 x white cyclorama, 14.0m x 9.0m 1 x black sharks tooth gauze / scrim 14.0m x 9.0m *Please note: use of the Cyclorama and rear tabs will reduce stage depth by 0.5m. Please contact Brisbane Powerhouse Technical Services for details. FALSE PROSCENIUM The Powerhouse Theatre has no proscenium. A false proscenium is available and can be installed at the Hirer s expense. Downstage opening 14m w x 7.75m h Upstage opening 11m w x 7.75mm h The proscenium is 2.05m deep and opens on a 55 angle POWERHOUSE THEATRE TECHNICAL INFORMATION AND GENERAL SPECIFICATIONS 2017 04

Lighting Information Lighting is rigged from five fixed bridges with upper and lower lighting bars located on the upstage and downstage sides of each catwalk. The height to the underside of the lower and upper lighting bars is 9.6m and 10.5m respectively. The Lighting bars are fixed to the bridges. Additional lighting positions are available from the galleries and from the motorised bars and trusses with prior arrangement. A standard lighting rig is provided as part of the standard room hire. For point loads and rigging information please refer to the rigging section. LIGHTING CONTROL 1 x Grandma 2 ultra-light 20 x HP 12 10 amp digital dimmer racks *14 racks are fixed position for catwalk outlets *6 racks are mobile for galleries and stage level positions DMX is distributed via Pathport nodes over a Cat6 network. Network ports for additional nodes are available around the venue. House lights are controlled via a Dynalite System with DMX input as required. LIGHTING FIXTURES 31 x ETC 750w Source Four 19o 20 x ETC 750w Source Four 26o 6 x ETC 750w Source Four 25/50 zoom 6 x ETC 750w Source Four 15/30 zoom 38 x Robert Juliat 329 2k Fresnel s 10 x Robert Juliat 329 2k PC 44 x 110v Par 64 MFL 28 x 110v Par 64 NSP on two way bars 9 x Selecon 1.2k compact PC 5 x Selecon Aurora 1250w 4 cell cyc battens 6 x PLCYC2 8 x 28v ACL with 60v splitters 8 x LED par wash with barn doors Unique 2.1 hazer 2 x LDR Canto 1200w MSR follow spots (on bridge one) Additional lighting equipment is available for hire, for a list please contact the Technical Services Department. ACCESSORIES 10 x Iris four ETC Source Four profiles 20 x B size gobo holders 8 x Medium B size breakup gobos 8 x Vertical slot B size gobos 8 x Horizontal slot B size gobos 10 x Trolley boom bases (various pipe heights available) 40 x S4 size top hats 12 x S4 size half hats Accessories are shared between multiple spaces, please confirm availability. POWERHOUSE THEATRE TECHNICAL INFORMATION AND GENERAL SPECIFICATIONS 2017 05

Audio and Vision Information The Powerhouse Theatre is supplied with a Martin Audio MLA Compact audio system for sound reinforcement. This system is supplemented with front fill, subwoofers, and stage monitors as required. A standard package of microphones, stands, cables, and power leads and interconnects are included in the standard venue hire. Additional audio equipment is available for hire. Please contact Brisbane Powerhouse Technical Services for a list of available equipment. SIGNAL CONTROL AND SPEAKER MANAGEMENT 1 x Digico SD8/24 digital mixing console 1 x 48in/8out Digico Madi stage rack 1 x Martin Audio Merlin digital loudspeaker and network manager. FRONT OF HOUSE PA 12 x martin audio MLA compact loudspeakers (6 per side) 6 x Martin DD6 Front Fill 2 x Martin Audio DSX Subs ADDITIONAL AUDIO EQUIPMENT Additional and specialty audio equipment such as side-fill speakers, wireless microphones, and recording interfaces are available for hire. Please contact Brisbane Powerhouse Technical Services for further details. VISION No vision equipment is included in the standard venue hire. The following vision equipment is available for hire: Sanyo 6K PLC-RM150L projector with various lens options HD220 16:9 screen (Front and rear projection) Dalite 4:3 screen Roland V-40HD video switcher Please discuss any vision requirements with Brisbane Powerhouse Technical Services staff. MONITOR SYSTEM 8 x Martin LE12JB wedges 4 x QSC amplifiers A Digico SD9 mixing console is available to hire as a monitor console. MICROPHONES AND DI BOXES 12 x SM 58 12 X SM 57 1X Beta 52 1X SM91 4X Rode NT5 6X Neumann KM 184 4X BSS audio DI 4X Radial DI STANDS 12X tall boom mic stands 12X short Boom mic stands POWERHOUSE THEATRE TECHNICAL INFORMATION AND GENERAL SPECIFICATIONS 2017 06

Contacts Kevin Stallan, Technical Director KevinS@brisbanepowerhouse.org Matt Staples, Head of Staging MattS@brisbanepowerhouse.org Pearl Bailey, Head of Sound and AV PearlB@brisbanepowerhouse.org Simon Cook, Head of Lighting SimonC@brisbanepowerhouse.org