Cable installation guidelines

Similar documents
High Voltage Cables kv. Handling and Operating Instructions

Underground Installation of Optical Fiber Cable by Pulling

Micro duct Cable with HDPE Sheath for Installation by Blowing

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

Laying of cables and lines in electrical installations and data networks

Optical Fibre Cable Technical Specification. Duct Cable GYFTY-24,48,72,144,216B1.3

Specification for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D)

MiniXtend Cable with Binderless* FastAccess Technology Jacket and Buffer Tube Removal Procedures. 1. General. 2. Precautions

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS DIELECTRIC HIGH PERFORMANCE OSP TUBE CABLE SERIES

TRANSMISSION ENGINEERING STANDARD TES-P , Rev. 0 TABLE OF CONTENTS 1.0 SCOPE 2.0 CABLES SPLICES

Processing Specification MiniBridge IDC

Bharat Heavy Electricals Limited HIGH PRESSURE BOILER PLANT, TIRUCHIRAPPALLI CONTROLS AND INSTRUMENTATION/FB

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX / TOD DIELECTRIC OSP TUBE CABLE SERIES

TERMINATIONS AND JOINTS FOR XLPE-INSULATED kv MEDIUM VOLTAGE CABLES

OPTICAL FIBRE CABLES. for very-high bit transmission and FTTx networks

Triax TechInfo. Installing and pulling Fibre Optic cables

3M Better Buried Closure (with 3M Scotchlok Shield Bond Connector 4462-FN and 3M High Gel Re-enterable Encapsulant 8882)

3M Better Buried Closures

User manual for cables and cable systems

Installation of Optical Fiber

TECHNICAL SPECIFICATION

Product Catalogue. Fibre Optic Cable

Spec No.: ZTT Revision: 2 Date: Oct 3, Designer. Senior Technical Manager. Approver. Chief Technical Engineer

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS-2 HIGH PERFORMANCE OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

OCC Installation Conduit Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX-2 OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

PEM1126ENG ENGLISH STPKR. TERMINATION KIT FOR PAPER CABLE WITH LEAD SHEATH 1 kv INSTALLATION INSTRUCTION

Aerial Cable Installation Best Practices

Field Instruction. Any registered training organisation UETTDRCJ21A Lay ESI electrical cables. Before commencing work:

ECONOMICAL 36 kv CABLE SYSTEM FOR THE BELGIAN NETWORK

Empowering businesses through innovative network solutions.

3M Better Buried Compound Compression Closure System

All Dielectric Self Supporting (ADSS) Fiber Optic Cable Installation

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

SWA Cable BS6724 Steel Wire Armoured LSZH Eland Product Group A9L

3M Cold Shrink Splice Kit QS-III 5515A

Non-metallic Aerial Distribution Optical Cables for FTTH Networks

Flygt Submersible Motor Cables

PROFIBUS Assembling Guideline Version 1.14 May 2015 Order No: 8.022

3M Cold Shrink Splice Kit QS-III 5416A

PEM1124ENG ENGLISH. STK TERMINATION KIT FOR PLASTIC CABLE WITHOUT ARMOURING 1 kv STKR TERMINATION KIT FOR PLASTIC CABLE WITH ARMOURING 1 kv

Installing a Wire Mesh Pulling Grip on All-Dielectric DX Armored Fiber Optic Cables

INSTALLATION INSTRUCTION PEM1368ENG ENGLISH

Instrumentation Cables

Revision No. 4 Page No. Page 1 of 7

SPECIFICATION. Optical Fiber Cable

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

3M Cold Shrink Splice Kit QS-III 5514A

3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT

Installation instructions Roxtec RM PE

Product Classification. Dimensions. Environmental Specifications. General Specifications. Material Specifications. Mechanical Specifications

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTP2-1 PLENUM RATED TUBE CABLE SERIES (NFPA 262) WITH GALVANIZED STEEL INTERLOCKED ARMORING

Our cables at: ATHENS AIRPORT PIRAEUS PORT TUNNEL IN PARIS NATIONAL PETROLEUM OIL COMPANY

Installation instructions Roxtec RM PE B

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division

SPECIFICATION 96F SM LOOSE TUBE, DRY CORE MINI CABLE

HD4K18GB-FO-xx-MM. HDMI 2.0 Active Optic Cables. Instruction Manual

Instructions. Cable with Armor F CAUTION. October Rev A

SWA Cable - BS5467 Steel Wire Armoured PVC Eland Product Group A9S

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

HITRONIC Optical Transmission Cable

Installation instructions Roxtec RM ES

PROFINET Installation Guideline for Cabling and Assembly

SPECIFICATION 192F SM LOOSE TUBE, DRY CORE MINI CABLE

INSTALLATION INSTRUCTION PEM1423ENG ENGLISH

Installation instructions Roxtec RM ES B

Installation instructions Roxtec RM BG systems

Public Works Division Lighting District Fiber Optic Specifications April 2009

Standard FTTH Drop Cable. FTTH DROP - nb6a1/g657a1

Installation instructions Roxtec RM BG B systems

FIBER OPTIC CABLE PULLING

SLiC Fiber Aerial Closure System

220KV EHV NETWORK AT RELIANCE JAMNAGAR REFINERY COMPLEX

Support Frame STB Technical Instruction Manual

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN

OPTICAL FIBER CABLE, ALL DIELECTRIC SELF SUPPORTING CABLE

Installation instructions Roxtec RM ES systems

Design Guide DSK/DSL

Number of Fiber 12 Core 24 Core 48 Core. Part Number

3 SLiC Aerial Closure with Rubber End Seal

ELECTRICAL SAFETY INSPECTION REPORT

VITALink Taped Splice Straight Through Crimp

Installation instructions Cable transit device Roxtec RS ES Ex

LEGEND POWER SYSTEMS

2178-L/S Series Fiber Optic Splice Case with Gasket

SECTION 4 TABLE OF CONTENTS

3M SLiC 530/533/733-2 Port 0.61 Cable Entry Bracket 3M SLiC 530/533/733-2 Port-MSM 0.61 Cable Entry Bracket

Number of Fiber 6 Core 12 Core. Part Number

Power and Control T YPE BY RAVI GANATR November/December IAEI NEWS

Metal Theft Taskforce Identification Booklet

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

Installing fiber optic cables

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR

Medium Voltage 12/20 (24)kV NF C cable system. Xavier Brosse Luanda May 2009

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR

Installation instructions Roxtec CF 16 EMC and Roxtec CF 16 O EMC

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-4/0-500

1. General. 1. Scope. 2. Quality Assurance

SPECIAL SPECIFICATION 2284 Fiber Optic Cable (Self-Supporting)

ETSI ES V1.1.1 ( )

Transcription:

The Quality Connection Cable installation guidelines Business Unit Industrial Projects

2 Cable installation guidelines www.leoni-industrial-projects.com GENERAL Installation methods Many different methods are used for cable installation. These include pulling, blowing and pushing into ducts, direct burial and aerial installation. Cable properties relevant for installation The most important properties of cables during installation are the tensile force, the bending radius and the installation temperature. The sections below provide some general guidelines for cable installation. The permissible temperature range, the maximum tensile force and the minimum bending radii are specified in the relevant data sheet for the cable. Additional relevant data may be specified if necessary, for example recommended microduct sizes for microduct cables. Some cable designs may require special drum handling and installation procedures. General installation guidelines Regardless of the cable type and installation method used, a few general recommendations should be complied with. Details on the various cable types are given in the following sections. During transport and installation, drums should always be handled in an upright position. For additional information, please refer to our Guidelines for Cable Drum Handling. Cables and drums should be inspected before installation. Special care should be taken in the following cases: If the winding package is loose. A loose package may cause loops during payoff. If the outer surface winding layer of the cable is damaged. Please do not use these cable sections for installation. If the labels on the drum are illegible or missing altogether. Please check to ensure that the right cable is installed. If the drum is lying on its flange or has been dropped. Invisible damages may have occurred or cable windings may have slipped over each other. If a drum is damaged, loose or rotting. It may break down during payoff. If drum screws are loose. Tighten them if necessary. If cable end seals are damaged or missing. Water may have seeped into the cable. If nails or clamps have been driven into or through the flange. In this case, the cable could be damaged or become damaged during installation. A check must be made as to whether any nails on the inside of the flange are loose. They must be removed because they could easily cause damage to the cable sheath. Before a cable is unreeled, its inner end on the drum must be released from the flange. The permissible temperature range for installation must be complied with at all times. The specified value is related to the cable temperature and not to the environmental temperature. In case of low temperatures, it may be necessary to preheat the cable before installation. The maximum tensile force must never be exceeded during installation. The installation equipment must allow online measurement of the tensile force and should have a suitable emergency stop which is activated when the maximum permissible force is exceeded. The cable must never be bent around radii smaller than those specified. All rollers, sheaves and sheave assemblies must not have smaller bending radii than those specified as the minimum radii for the cable. The radius of a roller is the distance between wheel tread and central axle. During installation, all curvatures should be smooth. The cable should be bent as little as possible. Turn-backs and all sharp changes of direction should be avoided. This publication provides information of value for the laying and installation of cables important for us as a cable manufacturer. For this reason, it should not be seen as a "complete" document which treats the subject exhaustively.

www.leoni-industrial-projects.com Cable installation guidelines 3 INSTALLATION, PROPERTIES AND COMPONENTS Bending radius It must be ensured that the permissible minimum bending radius is complied with during the entire installation process. All wheels must have the required minimum radius. The "real" radius of a wheel is the distance from tread to centre, not from flange to centre. r Pulling eye and wire mesh grip A pulling eye or a wire mesh grip is used for pulling cables. These tools transfer the pulling force to the cable. The pulling eye allows higher pulling forces because all strain-bearing elements of the cable are connected to it whereas the wire mesh grip is connected with the outer sheath only. Cable end equipped with pulling eye Avoid excessively small bending radii. or wire mesh grip. Instead of one big wheel, a set of wheels may be used to ensure a suitable bending radius. Never use multiple bends. Avoid turn-backs. Cable rollers During installation, cables should not slide over the floor, causing friction. To avoid damage, cable rollers should be used. Cable rollers

4 Cable installation guidelines www.leoni-industrial-projects.com INSTALLATION METHODS Depending on their design, cables are installed using various different techniques. Most outdoor cables are installed as underground cables. The following main methods are used for underground installation: Installation in ducts (by blowing, pushing or pulling) Installation in covered ducts Installation via direct burial Installation in ducts Depending on design, weight and dimensions, cables can be either pulled or blown into the ducts. Lightweight and rigid cables should preferably be installed by blowing whereas heavy cables should be installed by pulling. Pulling methods require higher tensile forces than blowing methods do. It must be ensured that the maximum tensile force permitted for the cable is not exceeded. The ends of the cables have to be sealed against moisture before, during and after installation. Cable ends should not be damaged during installation. Cables can be pulled using a cable grip (wire mesh grip) on the outer sheath or a pulling eye. It should be kept in mind that the first few metres (usually approx. 1 to 2 metres) of the cable may be unusable or damaged after installation due to the use of pulling eyes or cable grips and may have to be cut away. Entry into the duct should be in a straight line in order to avoid bends and scratches. This can be ensured by the use of a funnelshaped bore guide. Lubricating grease may be used to help the cable to slide in the duct. Lubricating materials must be compatible with cable sheath and duct material. A small cavity under the cable front of the duct is suitable to prevent sand, small stones and dust from entering the duct during pulling. After pulling, a cushion layer should be placed under the cable. Lower tensile forces occur during blowing because the cable is mainly transported by the air stream. Using an end cap to tighten the cable head towards the duct adds some tensile force. Cables should be unwound without turn-backs. Unwinding of cables (direction depends on position of duct). Avoid turn-backs. Cable should enter the duct in a straight line. A funnel-shaped duct bore guide. Lubrication may be used if necessary. A cavity in front of the duct prevents stones from entering the duct. Place a cushion layer under the cable after pulling.

www.leoni-industrial-projects.com Cable installation guidelines 5 Installation in covered ducts or troughs Covered ducts or troughs are cable tunnels which usually contain a larger number of cables. To install cables, the covers are removed. Ducts or troughs should be provided with deflector rollers to avoid friction between cable and duct or trough. The cable may be positioned manually. If feasible, the payoff itself can be moved along the duct or trough. If the cable is pulled, suitable rollers should be used to guide the cable and to guarantee safe bending radii. It is recommended to use sufficient installation rollers to ensure that the cable does not slide over the floor, causing friction. Motor-driven rollers are recommended for the installation of heavy cables. Installation via direct burial Underground cables installed via direct burial usually have a stronger sheath design than duct cables in order to allow them to withstand higher mechanical forces such as impact or crushing. Other possible influences on cable design such as rodent protection, chemical resistance, etc. should also be considered. Cables are either laid in pre-dug trenches or ploughed in when the trench is dug. The trench is filled up with soil again after cable installation. The cable itself is usually protected by a cushion layer of sand or something similar. Suitable measures must be taken to avoid excessively small bending radii. Cable rollers Installation with and without motor-driven rollers.

6 Cable installation guidelines www.leoni-industrial-projects.com INSTALLATION OF COPPER CABLES Tensile load During the mechanical pulling of cables, particular care must be taken to ensure that the permissible tensile loads are not exceeded. It is vital to make constant checks of the tensile load and provide safety devices which will stop the winch if tensile loads become too high. The data shown in Table 1 apply for the calculation of the permissible tensile loads. For the exact values, please see the relevant data sheet for the cable. Table1: Determination of the permissible tensile load Type of pulling Cable design Formula Factor With pulling Cables of all types P = x S σ = 50 N/mm² eye on conductors With pulling Plastic cables without P = σ x S σ = 50 N/mm² grip metal sheath and without armouring With pulling Plastic cable with P = K x d² K = 9 N/mm² grip wire armouring P: max. tensile load in N σ: max. tensile stress in N/mm² S: sum of conductor cross-sections in mm² (circuit and grounding conductors only, no screens) K: factor in N/mm² d: overall diameter of cable Installation temperatures Cables should not be installed below the following minimum temperatures: Type of cable min. temp. Cable with PVC sheath 5 C Cable with oil-resistant PVC sheath + 5 C ICON Arctic Cable with FRILON PVC sheath 30 C (optimised for low temperatures) Cable with PE or XLPE insulation and PE sheath 20 C These figures apply to the cable and not to the ambient temperature. If cables are to be installed at a lower temperature, they must be pre-heated beforehand. Care must be taken to ensure that the temperature of the cable does not drop below the lowest permissible installation temperature during installation. Special requirements for cables with flat steel wire armour and counter helix When installing cables with armour made of flat steel wires, special attention must be paid to cable payoff from the drum in order to avoid caging of the armour wires due to multiple bends in the cable. When a cable is installed in a duct, it must be unwound from the bottom. Unwind from the bottom. Bending radii The following values should generally be complied with when cables are installed. For the exact values, please see the relevant data sheet for the cable. Bending radii can be reduced to half the permitted values in extreme cases provided that they are bent once only and that expert installation is guaranteed (heating up to 30 C, bending over a template). In the case of products manufactured according to specific national or international standards, the relevant bending radii should be complied with. Table 2: Permissible bending radii Cable type Bending radius Cable without armouring 7.5 x overall cable diameter and lead cover Cable with armouring 10 x overall cable diameter Cable with lead cover 15 x overall cable diameter Special requirements for heavy cables, e.g. cables with a lead sheath When installing heavy cables, it must be borne in mind that loose windings will cause loops. Even small loose windings invisible from the outside are critical. In the case of heavy cables, unwinding must be done very carefully, using a slow speed in order to allow the cable to move on the drum. The inner end of the cable must be loose in order to allow free movement. It may be a good idea to always unwind the cable from the bottom. Unwind from the bottom.

www.leoni-industrial-projects.com Cable installation guidelines 7 INSTALLATION OF LSZH SHEATHED CABLES In general, there is no difference between the installation of cables with PVC and LSZH sheaths, except that the strict observance of the installation temperature is of great importance. place (figure of eight), so it is important to lay the cable in a figure of eight in the correct way. 3 Cable with LSZH sheath min. temp. max temp. Minimum temperature 5 C + 50 C 4 3 2 1 1st Layer 2nd Layer 3rd Layer 1 2 1st Layer 2nd Layer 3rd Layer The permissible temperature range for installation must be complied with at all times. The specified value ( 5 C to + 50 C) applies to the cable temperature and not to the ambient temperature. During the installation process at temperatures of + 50 C and above, LSZH sheathed cables are more sensitive to cracks and other damage caused by mechanical stress. The risk of damage occurring during the installation process rises with the temperature. Mechanical stress can be caused by: falling below the permissible bending radius. mechanical influences (pressure on the outer sheath) at crossing points: the armour wires of one or two cables crossing each other generate a point of high pressure at this INSTALLATION OF FIBER OPTIC CABLES In addition to installation by pulling or blowing, improved methods for blowing and pushing into microducts are commonly used for Fiber optic cables. These techniques are especially suitable for use with lightweight and rigid cables. Blowing into microducts Fiber optic cables should preferably be installed by pulling or blowing. Instead of installing a cable in a duct, several microducts (= small ducts) can be blown in first. Microduct cables are then blown into the microducts. Common microduct types have inner diameters of between 3.5 mm and 10 mm. Optimised microduct cables and special blowing equipment must be used for these ducts. Regular blowing distances are between 1000 m to 2000 m. Short installation distances of up to 100 m to 200 m can be achieved by pushing in most cases. The installation performance depends to a great extent on cable design, blowing equipment and type and condition of the microduct. Right Wrong cables damaged beforehand due to the pulling process. rough handling of the cables during the pulling process (for example pulling cables over edges). torsion of the cable in the wrong direction ( opening of armour wires ): it is important that the cables are FIRST turned in such a way that the armouring becomes tighter. If they are first turned in such a way that the armour wires open or if this is done too frequently, stress is applied to the outer sheath, causing the outer sheath to open at high temperatures. In comparison with PVC, LSZH material has a very low tear resistance, so once a cable is damaged, the crack will split further. The blowing equipment must have an automatic emergency stop. Otherwise cables may be damaged or destroyed if the blowing process is interrupted. Bending radii for Fiber optic cables If not specified otherwise for this type of cable, the bending radius should not fall below the value given below. For exact values please see the relevant data sheet for the cable. Table 3: Minimum bending radii Installation Bending radius During installation 20 x overall cable diameter (up to maximum tensile force) After installation (no tensile force) 15 x overall cable diameter Temperature range If not specified otherwise, the minimum installation temperatures for the Fiber optic cables are as given in Table 4. With this installation method, it is vital to use clean cables, i.e. cables may not be stored outside and the drum must always be protected against dirt by a plastic tape. The cable should be lubricated before blowing. Only lightweight drums without defects which allow perfect payoff may be used. Table 4: Minimum installation temperature Type of cable sheath Minimum installation temperature Minimum storage and transportation temperature Polyethylene sheath 10 C 25 C PVC sheath 5 C 25 C LSZH sheath 5 C 25 C

Find out more: Business Unit Industrial Projects www.leoni-industrial-projects.com LEONI Kerpen GmbH Zweifaller Str. 275 287 52224 Stolberg Germany Phone +49 (0)24 02-17-1 Fax +49 (0)24 02-1 75 62 E-mail industrial-project@leoni.com PM Industrial/Cable installation guide 3/2017