Lighthouse Theatre Technical Specification

Similar documents
DEREHAM MEMORIAL HALL

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

CHELSEA THEATRE. Technical Specifications

Technical Specification

Technical specifications Main theatre. Sound

Matt Dann Cultural Centre

Technical Specification

HIRE AND TECHNICAL INFORMATION

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

Main House Technical Specification

Technical Specification for the Alley Theatre, Strabane

The Haymarket Basingstoke Technical Specifications

New Theatre Royal Lincoln Technical Information

JERWOOD VANBRUGH THEATRE

INFORMATION FOR VISITING COMPANIES

Technical Specifications Updated 01/10/2017. Stage

Auditorium Seating VISY THEATRE TECHNICAL SPECIFICATIONS

Theatre Technical Specifications

Harrow Arts Centre, Harrow Council, Uxbridge Road, Hatch End, Harrow, HA5 4EA tel

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

2017 TECHNICAL SPECIFICATIONS

Main House Technical Specifications

There are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated.

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

Theatre Technical Specification

Dr JOHN GALLAGHER CONCERT CHAMBER

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

TECHNICAL SPECIFICATIONS

Technical Specifications

Source 4 Junior Zoom Profile 575W 14 part of universal rig

VISY THEATRE TECHNICAL SPECIFICATIONS Version 2.6 3/7/2013. Auditorium Seating. Page 1 of 4 STAGE CONFIGURATIONS

Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black)

"A Dance Tribute to Ping Pong " by Jo Strømgren Kompani. Technical Requirements

Technical Pack. Attenborough Arts Centre

Hopgood Theatre NOARLUNGA CENTRE

Technical Specification

Technical Director of Production Andrew Quick Ext 252

Dubbo Regional Theatre & Convention Centre Theatre Technical Specifications

Capacity: 60 2 Roxburgh Place, EH8 9SU. Assembly Roxy - Downstairs

Tech specs: Main Auditorium. Dimensions. Prompt Corner. Stage Floor. Dressing Rooms (Under stage)

Arlington Arts Tech Spec 2018

Technical Specifications

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

MAIN HOUSE TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

Shouson Theatre Venue Specifications (updated Jan 2017)

Technical Specification (October 2017 v4.2) Theatre and Technical Manager: Phil Pattie

UNIVERSITY CONCERT HALL. Technical Specification

Technical Specification (Studio Theatre)

Technical Specification Pavilion Dance

THE STREET THEATRE. Technical Specifications

BANYULE THEATRE TECHNICAL INFORMATION. 10 Buckingham Drive Heidelberg VIC Page 0 of 10

TECHNICAL SPECIFICATIONS

PSYCHIC SALLY PRODUCTION RIDER & FOH REQUESTS (UPDATED 2016)

Hirers Technical Information Pack

TECHNICAL SPECIFICATION

Sandusky State Theatre Technical Specifications

PRELIMINARY TECHNICAL RIDER - LITTLE RED RIVER

Technical Data Sheet

ADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION

Queensland Performing Arts Centre

ISLAND HALL TECHNICAL INFORMATION

Latrobe Performing Arts Centre

Technical Specification (Studio Theatre)

Technical Specification (Drama Theatre)

Technical Specifications Nov 2016

Salisbury Arts Centre Technical Specification v Page 1 of 7

Stage. Get In & Parking

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.

COURTYARD!!!!! THEATRE

Technical Information

Technical Specification. Updated: April 2016

Summary. Access and Parking

Hopgood Theatre NOARLUNGA CENTRE

MAIN THEATRE TECHNICAL SPECIFICATION Updated 17 th April 2014

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

Dr. Fred Speckeen Theatre. Information and Technical Specifications

MAIN AUDITORIUM TECHNICAL INFORMATION

Phil L. Thomas Performing Arts Center Shiprock, New Mexico

PLEASE NOTE THAT DUE TO A VOIDED FLOOR PYROTECHNICS ARE NOT PERMITTED IN THE STUDIO.

Festival City Theatres Trust Festival Theatre Technical Specification. Smoking Policy

CENTRE FOR PERFORMING ARTS

Darlington Hippodrome Technical Specification

Pleasance London Main House Visiting Company Information Pack May 2017

WYCOMBE SWAN Wycombe Arts Management Ltd registered in England and Wales No Registered Office: 16 High Holborn, London, WC1V 6BX

Visy Theatre technical information and general specifications 2019

The Haymarket. Technical Specifications. The Haymarket, Wote Street, Basingstoke, Hampshire, RG21 7NW

BURDEKIN THEATRE BURDEKIN THEATRE. Technical Specifications. Updated 08/02/2008

Technical Specifications. Taylor Little Theater

MAIN THEATRE TECHNICAL SPECIFICATION

John Leslie Theatre. Technical Specifications. Updated July 2018

TECH SHEET AND INFORMATION (Updated )

Technical Specification (Drama Theatre)

Technical Information

The Lights Technical Guide June 2017

W.L. LYONS BROWN THEATRE TECH PACK. Under the Management of

ROSE THEATRE BASEMENT

Technical Information

Transcription:

Lighthouse Theatre Technical Specification Auditorium Ground Floor 15.3m x 17.5m Balcony 4.5m x 17.5m Capacity 548 Seating Disabled Seating General Fixed tiered seating; 405 ground floor, 119 balcony, 24 in boxes 6 wheelchairs maximum Acoustically insulated roof & walls Displacement air conditioning and heating Additional: WIFI throughout and Ethernet internet access available on stage CAD drawings of theatre available on request Stage Stage area 16m (inc. wings) x 10.15m On stage area 10.5m width x 9m depth x 6m trim height Proscenium arch 11.7m wide x 5.9m high (10.5 x 5.5 with tormentors & border) Fly grid 11.9m above stage floor fitted with 20 fly barrels each with a swl of 200kg. Rear five barrels restricted flying height Stage access External door and internal doors 4.5m high x 3.5m wide via 9m x 4.5m Stage floor Power supply Orchestra pit scene dock. Personnel access from auditorium left and right Has a swl on the stage of 5KN/m² suitable for medium weight vehicles and self-propelled high level access equipment 63amp 3 phase and 32amp 3 phase travelling supply on stage. 3 phase single phase jumpers available 9.0m x 3.0m floor 2.5m below stage. Temporary cover installed when not in use but not a load bearing structure If pit is required venue must be notified a minimum of 6 weeks prior to production

Lighting The house lighting system comprises of 2 systems: System 1: High bay discharge and fluorescent working light, 300 Lux Non-dimmable System 2: Overhead and Wall Lighting, Tungsten Houselights Fully dimmable over 3 circuits (DMX channels 91-92-94) Theatrical lighting can be installed from 2 lighting galleries over auditorium, positions along front of circle and boxes, slots on either side of proscenium arch or from any of the counterweight barrels. All barrels are standard 48mm Lighting Control: Zero88 Leapfrog 48/96 from control at back of stalls Chillinet memory recall system side of stage or control room 2 DMX Universes Universe 1 for dimmers, Universe 2 distributed around auditorium and stage via 24 way splitter. Splitter can be patched to Universe 1. Lighting Stock: Stage 6 CCT 13-23 1000w (A&B size Gobo holders available) 8 Par64 1000w black fitted with CP62 Wide Lamps 15 Strand 743 1000w Fresnel 8-60 (Barndoors available in various sizes) 5 Teatro Aymmetrical 3 Cell Cyc Batterns 500w FOH Fixed 7 CCT Silhouette 19-40 1000w (A&B size Gobo holders available) 6 Par64 Long nose 1000w black fitted with CP62 Wide Lamps 2 Source Four Junior Zoom 750w 25-50 (M size Steel Gobo holders and irises available) 4 Source Four 750w 26 Lenses (B size steel Gobo holders and irises available) 2 Source Four 750w 36 Lenses (B size steel Gobo holders and irises available) 10 Strand Cadenza Zoom 12-22 2000w built in iris (A size Gobo holders available 2 Selecon Pacific 1200w Tungten Followspots. C/w 4 colour Magazine, iris and external dimmer control. Note: All lanterns are fitted with safety bonds, Clamps and Colour frames Additional Lighting in stock 4 Source Four 750w 19 Lenses (B size steel Gobo holders and irises available) 5 CCT 13-23 1000w (A&B size Gobo holders available) 5 CCT Silhouette 19-40 1000w (A&B size Gobo holders available) 4 Strand Patt 243 2000w Fresnel 16-50 4 Strand 743 1000w Fresnel 8-60 (Barndoors available in various sizes) 4 CCT Starlette 1000w Fresnel 6-57 6 Stairville Par64 10mm LED chrome double yoke. 7ch DMX. May incur a charge 20 Par64 1000w black fitted with CP62 Wide Lamps 1 Strand Nocturne Symmetrical Floods 1000w Note: Other Lamp types are available upon request and may incur a charge

A good range of Lee Filters are stocked. Note: Substitutes will be made as close to gels requested for all Rosco Gels or colour not in stock unless otherwise stated. This may incur a charge. No Gobos are held in stock, please advise if Gobos are required. These may incur a charge. The Lighthouse has a generic Lighting Rig, to cater for the majority of performances. This consists of: 4 colour wash on stage and FOH Gobo breakup wash 6 on stage profile specials 3 colour cyc wash Parcan back lighting 6 FOH specials FOH warm and cold wash The rig plan is attached to this document. Dimming 72 channels of Dimming via Zero88 Chillinet 2410 Dimmers. Max load of 10amps per channel (2.5kw) 2 x Zero88 Betapack Portable 6way Dimmer Analogue 5amp per channel. 32amp single phase power 1 x showtec analogue DMX convertor (DEMUX) Cables Small stock of 15amp extension leads, Various lengths Small stock of 13amp extension leads, Various lengths Small stock of 16amp extension leads, Various lengths Small stock of adaptors, grelcos, jumpers 2 x 63amp 3 phase long extension leads 2 x 32amp 3 phase long extension leads Various 3 phase single phase jumpers

Sound Mixing desk Soundcraft Live 8 (40 channel) Analogue desk 6 aux sends, 8 groups 4 stereo inputs (Installed at rear of stalls. A toured desk can be sited here also.) Equipment Twin deck CD Playback MD playback 1 x Alesis dual channel compressor / limiter 1 x Lavalier OR handheld radio microphones Channel 70 Induction hearing loop system Dressing room relay 5 x Crest Audio amplifiers 1 x Peavey quad amp (4 monitor feeds) Monitor distribution patch panel 3 x Samson Crossovers 4 x Peavey Sanctuary Series SSE 1564 FOH speakers 2 x Peavey Black Widow Subwoofers 4 x Monitor Speakers (2 x Stageline, 2 x JBL) 2 x 32 band EQ 1 x SM58 vocal microphone 1 x SM57 microphone 1 x Yoga FX510L microphone Shure Drum mic kit Various tall and short boom mic stands 5 x Passive DI s 24/8 Multi to back of stalls Communication Show audio relay to dressing rooms from fixed FOH microphone Microphone feed to dressing rooms 6 way Canford Tecpro Talkback System (distribution throughout the theatre) 2 x two way radios Video relay to stage and dressing rooms Sound and Video feed to FOH Special Effects Pyrotechnics Smoke Machines Snow Machines Le Maitre pyroflash 6/24 firing system Note: Pyrotechnics effects must be agreed and organised with the technical management and will incur cost for consumables 1 x Le maitre G100 1 x Antari 2 x Vivid 2 x Skytec Haze Machine 1 x Look Solutions unique 2 Misc 1 x Strobe light 2000w strobe light fixture 2 x UV Balcklight fixtures Note: All special effects must have prior agreement with the venue before use

Rigging & Flying 4 x Tank trap boom stands Stock of cable grips (Dogs) 4 x 1 tonne 2m flying drifts with hard eye to eye 8 x Alloy Bow shackles, 1 tonne Audio Visual The Lighthouse has access to various projectors and screens suitable for the venue. Costs may be incurred. Other: Dressing rooms 5 dressing rooms, 6.5m x 3.5m Each dressing room has: Toilets and showers Individual air conditioning units Full length mirror Tea & Coffee making facilities Dressing tables with mirrors Clothes rails with hangers Note: Ground floor dressing rooms are lockable. Access and use of the third floor backstage is strictly prohibited without prior arrangement. Additional dressing rooms are available FOH and may incur a charge. Furniture Storage Equipment Hire Equipment Prices We are able to supply a number of chairs and tables with prior arrangement. We are unable to store any particulars of your show after the performances without prior arrangement. A charge may be incurred for items left at the venue. Any items left will be disposed of after 1 month. We have a close team of trusted and capable hire companies that provide us with equipment required for a performance that we do not have on site. Please discuss your requirements with us in good time of your production or before hiring as we are able to gain very competitive rates. Please enquire about our equipment prices. We aim to provide you with our best possible prices from our suppliers. For any further information please contact: Theatre Manager: rob@lighthousetheatre.co.uk Telephone: 01536 414141 Technician: Dave Jones Telephone: 07895 458411

Diagram 1: Lighthouse Theatre Lighting Rig