Mind Alive Inc. Product History

Similar documents
INTRODUCTION COMPONENT LIST

The EEGer 4.3 Tutorial

Thought Technology Ltd Belgrave Avenue, Montreal, QC H4A 2L8 Canada

Stereo Box Pre Box Amp Box Amp Box Mono Switch Box. Tuner Box Dock Box F / V Phono Box MM Record Box USB Phono Box II

TAGx2 for Nexus BioTrace+ Theta Alpha Gamma Synchrony. Operations - Introduction

Re: ENSC 370 Project Physiological Signal Data Logger Functional Specifications

TECHNICAL SPECIFICATIONS, VALIDATION, AND RESEARCH USE CONTENTS:

SedLine Sedation Monitor

Hardware Setup. If you have any further questions after checking this document, please contact

BrainMaster tm System Type 2E Module & BMT Software for Windows tm. Display Screens for Master.exe

The Ultimate Long-term EEG Monitoring System

Current Trends in the Treatment and Management of Tinnitus

1.2 General Description

We recommend to use program 01 and 03 (SOFILIGHT PROGRAMS) to get started and become familiar with the MIND ACTIVATOR HOLIDAY.

SC24 Magnetic Field Cancelling System

An Exploration of the OpenEEG Project

SC24 Magnetic Field Cancelling System

PROGRAMMING GUIDE. Accurate Targeting. Precise Control.

Brain.fm Theory & Process

NVISION Compact Space and cost efficient utility routers

SC26 Magnetic Field Cancelling System

User Guide Slow Cortical Potentials (SCP)

DSA-1. The Prism Sound DSA-1 is a hand-held AES/EBU Signal Analyzer and Generator.

UNDERSTANDING TINNITUS AND TINNITUS TREATMENTS

PRICE-LIST RITMSCENAR DEVICES AND ADD-ON ELECTRODES. License No dated November 05, 2014 (RITM OKB ZAO, Russia)

MP212 Principles of Audio Technology II

ANTHEM NOW SHIPPING MRX 710 AND MRX 510 A/V RECEIVERS No trade offs: high-end performance with ease of integration.

USER S GUIDE DSR-1 DE-ESSER. Plug-in for Mackie Digital Mixers

UNIVERSITA DEGLI STUDI DI CATANIA Dipartimento di Ingegneria Elettrica Elettronica e dei Sistemi DIEES. Paola Belluomo

Work In Progress: Adapting Inexpensive Game Technology to Teach Principles of Neural Interface Technology and Device Control

ISCEV SINGLE CHANNEL ERG PROTOCOL DESIGN

The Bio Tuner Model BT8 Manual

PRODUCT SHEET TRANSDUCER MODULE GSR100C

The Bio Tuner. Model BT7 Manual

AUTOMATIC VIDEO LOSS A/B SWITCH

VivoSense. User Manual Galvanic Skin Response (GSR) Analysis Module. VivoSense, Inc. Newport Beach, CA, USA Tel. (858) , Fax.

Introduction to LasrPlay and DVDplay Synchronizers

CEDAR Series. To learn more about Ogden CEDAR series signal processing platform and modular products, please visit

ME EN 363 ELEMENTARY INSTRUMENTATION Lab: Basic Lab Instruments and Data Acquisition

Dynatel Advanced Cable Locator 2250

BeneHeart R3. Electrocardiograph

APPLICATION NOTE # Monitoring DTMF Digits Transmitted by a Phone

LEVEL ONE Provider Reference

MEE 1000A. Neuromaster MEE-1000A. Intra-Operative Monitoring System

PROFESSIONAL GRADE TOOLS THAT ARE EASY TO USE REVOLUTIONARY TECHNOLOGY (YOU CAN AFFORD) BYTE BROTHERS 2010 PRODUCT CATALOG

Recording to Tape (Analogue or Digital)...10

BioGraph Infiniti Physiology Suite

Pre-Processing of ERP Data. Peter J. Molfese, Ph.D. Yale University

Scan Converter Installation Guide

SMARTING SMART, RELIABLE, SIMPLE

CG-1 CAMERA-GUARD INSTRUCTION BOOK IB647501

Experiment PP-1: Electroencephalogram (EEG) Activity

PRODUCT SHEET

Operating Manual. intelligent Lifestyle

P116 SH SILENT PIANOS

Katie Rhodes, Ph.D., LCSW Learn to Feel Better

4.9 BEAM BLANKING AND PULSING OPTIONS

As the vinyl revival keeps on rolling forward, Ian Ringstead takes a listen to the 599 Pro-Ject RPM3 Carbon turntable.

MEE 1000A. For more than 50 years, healthcare. Neuromaster MEE-1000A Intra-Operative Monitoring System

Stud Welding Equipment

WAVES Cobalt Saphira. User Guide

TED Pro Energy Monitoring and Control System

Metal Electrode Meter

S1 Digital/Analogue Radio Broadcast Mixer September 2009

WVR500 Waveform/Vector Monitor

OPERATOR S MANUAL MICRO SEVEN, INC MODEL LS15-C1 TELEPHONE LINE SIMULATOR

USER MANUAL. Blackburst, Sync, Audio Tone Generator. For Models BSG-50, RM-50/BSG, SR-50/BSG. Doc Rev. F (C) Copyright 2014

Auxiliary states devices

AC182A 8 Input x 8 Output S-Video Matrix Switch with Audio

Camera Setup Instructions

LD-V4300D DUAL STANDARD PLAYER. Industrial LaserDisc TM Player

3-DRX. AUTOMATIC THREE CHANNEL DIGITAL AES/EBU REPEATER and ANALOG AUDIO SWITCHER INSTALLATION AND OPERATING MANUAL

Development of 16-channels Compact EEG System Using Real-time High-speed Wireless Transmission

Flexible Counter Series in DIN size 24 x 48 mm

7000 Series RossGear Series RossGear

ATEM Television Studio

Zero Crossover Dynamic Power Synchronization Technology Overview

CMN-91. Multiformat Signal Analyzer FEATURES

5/8/2013. Tinnitus Population. The Neuromonics Sanctuary. relief. 50 Million individuals suffer from tinnitus

potentiostat/galvanostat

Emotiv Xavier Pure.EEG Epoc/ Epoc+

Specifications. End-Point Linearity - ±5% F.S., when used with HACO SCR-speed control

User Guide EMG. This user guide has been created to educate and inform the reader about doing EMG measurements

Displays Open Frame Monitor Model Number: AND-TFT-150Bxx

INSTRUCTION MANUAL. J800 Weld Controller. 3/25/2018 Revision

Stimulus System of Shielded Room (DC)

medlab One Channel ECG OEM Module EG 01000

Model LTM-1400 User Manual LTM Multiformat 1x4 Assignment Router / DA. (Component, Y/C, Composite, Balanced Audio, RS422) 2001 Laird Telemedia.

PRO-HDMI2HD. HDMI to SDI/3G-HD-SD Converter. User Manual. Made in Taiwan

G ARD SECURITY SYSTEM Product Listing 2007

MULTIDYNE INNOVATIONS IN TELEVISION TESTING & DISTRIBUTION DIGITAL VIDEO, AUDIO & DATA FIBER OPTIC MULTIPLEXER TRANSPORT SYSTEM

UTAH 100/UDS Universal Distribution System

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

PROGRAMMER MANUAL. Programmer Model Rx Only

Tonaki Tinnitus Protocol Review

What is sync? Why is sync important? How can sync signals be compromised within an A/V system?... 3

MTP 15HD A Series MTP - MINI TWISTED PAIR TRANSMITTERS & RECEIVERS FOR COMPUTER VIDEO & AUDIO. Twisted Pair.

QuickTIPS REMOTE CONTROL TRULINK FOR ANDROID DEVICES VOLUME CHANGES MEMORY CHANGES. PRODUCT AVAILABILITY: Halo iq, Halo 2, and Halo Devices

Mini Electronic Pulse Massager

Hitachi Kokusai Electric Comark LLC

Transcription:

Mind Alive Inc. Product History Product Type Years Sold DAVID 1 AVE (1984-1990) DAVID Jr & DAVID Jr.+ AVE (1988-1990) DAVID Paradise AVE (1990-2000) DAVID Paradise Jr AVE (1995-2000) DAVID 2001 AVE (1995-2003) DAVID Paradise XL AVE (1995-2007) DAVID Paradise TC AVE (2000-2007) DAVID Paradise XL + AVE + CES (2001-2007) DAVID Pal AVE (2003-2011) DAVID Pal 36 AVE (2003 2011) DAVID Pal 36 & with CES AVE & CES (2006-2011) DAVID ALERT AVE (2007 - Present) DAVID Delight AVE (2009 Present) DAVID Delight Plus AVE (2010 Present) DAVID Delight Pro AVE & CES (2010 Present) DAVID ALERT Pro AVE & CES (2012 Present) DAVID SMART AVE (2012 Present)

Oasis (3-wire) CES (1993 1994) Oasis 2-wire CES (1994-1995) Oasis Stereo CES (1995-2001) Oasis Variable Frequency CES (2001-2007) Oasis II CES (2008 2013) CESta CES & tdcs (2007-2011) Oasis Pro CES & tdcs (2011 Present) Bioscan EDA EDR Biofeedback (1997 2007) Bioscan ABT EEG Biofeedback (2002-2006) Definitions AVE CES TENS tdcs EDR Biofeedback ABT Biofeedback - Audio-Visual Entrainment - Cranio-Electro Stimulation - Transcranial Electro-neural Stimulation - transcranial Direct Current Stimulation - Electrodermal Response - measures electrical resistance of skin to detect stress - Alpha Brainwave Trainer - measures brain EEG activity to differentiate between attention and meditation Audio-Visual Entrainment (AVE) Products In November of 1984, I began design of the DAVID 1, used to help Performing Arts students overcome stagefright. I finished the first product in June of 1985. Word caught on quickly with clinicians and I sold about 150 more units. There seemed to be a need for a lower cost device for the general population, we developed the DAVID Jr., a 10-session AVE device and then shortly thereafter, the DAVID Jr. Plus, which was essentially a DAVID Jr, but onesession (one module) programmable and in an attractive case with a sloped panel. We wanted an AVE product that had more sessions, a numeric display and a keypad for selecting the various sessions, but also allowed manual control and so the DAVID Paradise was born. It held 36 sessions and could be manually programmed via the keypad with one fairly complex session consisting of many modules. We made 19 variations of the Paradise. We wanted a family of devices, so we made a lower-cost Paradise Jr. in 1995.

With the development of the Tru-Vu (field-independent) eyesets, we developed the Paradise XL, which looked much like the Paradise, but supported dual-frequency stimulation and pulse-width control. Users could also program their own sessions into it using the Paradise XL Session Editor. It was programmable via the serial port on a computer. It held 40 factory-preset sessions and could accommodate up to 24 custom-made sessions (with an overall total of 140 modules), plus another 24 proprietary sessions, that could be purchased as add-ons. It also had non-volatile memory in that the battery could go dead and the User Defined Sessions would not be lost from memory. In 1995, we also developed the DAVID 2001. This was a concept AVE device that used large cup-sized headphones in which all of the electronics were embedded into the left cup. It had 18 sessions plus intensity control. Volume was controlled via dials on each ear cup. Rechargeable batteries were slipped into the padded band covering the head and the band end was stitched closed to keep the batteries in. There was an eyeset jack on the left cup and the eyeset had a short 3 wire that plugged into it. The 2001 was very popular and nice to use. In 2000, we introduced the Paradise TC. The display and the manual frequency adjustment was removed, and it was priced lower than the Paradise XL. The DAVID Pal Brand With the development of smaller microcontrollers, we were able to dramatically reduce the size and cost of the electronics and, so we developed the Pal series of devices. The Pal devices (Pal, Pal 36 & Pal 36 with CES) were compact and quite easy to use. The Sound Sync was also dramatically improved, producing sometimes vivid imagery from various audio files and music and it would shut off automatically when the audio ended. The Pal had 18 sessions in one library consisting of three banks of six sessions. The Pal 36 had two libraries of 18 sessions and the Pal 36 with CES had a small slider in the front that also controlled CES. And it was smart too! If the slider wasn t turned up for stimulation, it would shut the CES section off as a battery-saving feature. It also knew if the slider was left turned up and refused to provide stimulation until the CES stimulation was turned down first. The session editor was also improved dramatically and renamed as the DAVID Session Editor. The DAVID Delight Brand The Delight series (Delight, Delight Plus and Delight Pro) really are a delight to use. Icons were used for virtually all functions to make it accommodate clients of all languages. All of the sessions are in categories, making it easy to select a session without consulting the manual all of the time. They also remember the last session used in each category, making it easy to go back to your favorite session. The Delight has five categories of two sessions each. Simply press the icon and that session will run. The Delight Plus also had five categories plus a user-defined section. However, it contained 25 sessions plus five Sound Sync sessions, so the bar graph was used for the actual session within a selected category. It remembered the last session selected in any category, making it easy to replay favorite sessions.

Electro-Stim Products TENS - Transcutaneous Electro-Neural Stimulation CES - Cranio-Electro Stimulation tdcs - Transcranial DC Stimulation Oasis Brand The Oasis products are hand-held, 9-volt powered CES/Micro-TENS devices. The original Oasis had three wires, based on the Neuropulse and operated at the Schumann Resonance frequency of 7.8 Hz. The next Oasis had two wires only and a bi-phasic pulse. It could also be synchronized with the lights on the Paradise. My third design of the Oasis could be synchronized in a proprietary stereo technique with the photic stimulation of the Paradise XL, which was now incorporating the Tru-Vu (independent-field) eyesets. The fourth was the Variable Frequency Oasis, which also had a frequency dial on it, ranging from 1 to 20 Hz. The Oasis II and the new Oasis Pro are microprocessor controlled. The Oasis II is a two-channel CES/MET device that does very simple 0.5 and 100 Hz stimulation. There are several unique aspects to the stimulation, including a rounded front pulse edge (patented) to reduce sting plus randomization (patented) of the stimulus timing to reduce habituation. CESta Based on the DAVID Pal format, this was our first multi-session, programmable CES device. It also supported transcranial DC Stimulation, an up-and-coming fascinating approach to Neurotherapy. We later added 50% duty cycle to the CES section. The CESta was also capable of producing colloidal silver. Both the tdcs and the colloidal silver were digitally current controlled. Oasis Pro The new Oasis Pro is an improved design of our original CESta. It has improved controls and electrode impedance-checking ability. It outputs dual frequencies from 0.1 to 25.4 Hz plus 100 Hz. The stimulus may be fixed or randomized. Sessions can be programmed to run any length of time from under a minute to 9 hours. It also automatically shows the frequency range (delta, theta, alpha, beta, etc) that it is stimulating at. It also has a tdcs bar graph showing the exact amperage output. It is our nicest electro-stimulation device to date. Biofeedback Products EDA Bioscan I had originally made an electro-dermal activity monitoring feedback device as early as the late 80s. Then I came to realize that it would be a valuable clinical tool if a baseline measurement could be made such that a clinician could see a referenced, objective trend over the course of treatment. So in 1997, I designed the EDA Bioscan, which comprised of a bar graph and variable tone pitch to indicate state arousal. A Trait dial was added, which allowed the clinician to determine a person s overall trait arousal and observe that trend over the weeks, against the level prior to treatment.

ABT Bioscan The Alpha-Brainwave Trainer (ABT) Bioscan was developed primarily to help people learn the difference between meditation and focused attention. There were selections for theta, alpha or SMR frequency bands. A bar graph and a variable pitch tone would indicate the amplitude of the brain wave. We didn t sell very many of these units, but they were fun to play with and demo. DAVID Session Editor Clinicians often need to stimulate their patients at a frequency in accordance with EEG or QEEG brain wave analysis. This graphical editor allows for user programming of all of our AVE and CES/tDCS units, except the Oasis II.