XW3D. Simple Wiring of Sensor Actuators. Connector Terminal Boxes. Specifications. Materials and Finish. Connection Combinations

Similar documents
E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

Model Number Structure

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Model Number Structure. Ordering Information

M2P. Large Rectangular-bodied Indicators. Indicator (Rectangular) List of Models

XS_-EU. M8 and M12 Sensor Connectors. Ordering Information

ZN-PD-SA. Air Particle Sensor. Continuously monitor dust fallout and particles which detract from product quality. Ordering Information.

Accessories (Order Separately)

Lighted Pushbutton Switch (Square) Ultra Bright LED Type

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure

UV Power Monitor. incident light 200 to 370 nm 300 C (Use at temperatures below the Fiber Unit s rated operating

Selector Switches 30-mm Selector Switches Universal Design. Emphasis on Color Coding, Workability, and Safety. Operation Unit Colors

M2P. Large Rectangular-bodied Indicators. Indicator (Rectangular) List of Models

XS2. Round Water-resistant Connectors (M12) Construction (XS2G Soldering Connector Plug Assemblies) Materials and Finish. Ratings and Specifications

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment

3M Pak 10 Socket 1 mm Straight and Right Angle, Surface Mount PK10 Series

CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC

LED Series Sealed Backlights

Voltage inputs: High and low signal voltages (count, reset, short, counter No. selection, I/O inhibit) No-contact outputs: RUN, forecast

EZ-LIGHT K30L Series With Independent Push Button Contact

K3MA-L. Model Number Structure. Ordering Information. Temperature Meter. Model Number Legend. List of Models

Photoelectric Sensors E3F2

EZ-STATUS WLS28-2 Multicolor LED Strip Light

Model # of Colors Colors Input Connection 1 K90TLGRPQ 2 Green, Red K90TLGYRPQ 3 Green, Red, Yellow K90TLBGYRPQ 4 Blue, Green, Yellow, Red

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

EZ-LIGHT K90FDL Daylight Visible

Model Number Structure

3M MetPak 2-FB Header

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Voltage inputs: High and low signal voltages (count, reset, short, counter No. selection, I/O inhibit) No-contact outputs: RUN, forecast

EXPlora. Introduction

Linear Array with Intensity Adjustment

Low Voltage Multifunctional LED Controller / DMX Decoder. Specification

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

Model: UHD41-ARC. Installation Guide

Instruction Guide February 2017

Instruction Manual MODEL RSP SANITARY ELECTRONIC PRESSURE TRANSMITTER

Installation Manual SaVi Note Underwater LED Light

Industrial Ethernet Cables XS5/XS6

WLS27 Multicolor LED Strip Light with EZ-STATUS

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

In-Wall Control Mount for ipod Touch

Table of Contents. Introduction Pin Description Absolute Maximum Rating Electrical Specifications... 4

45LM Series Modules. Features. Specifications. Plug-in Logic and Display Modules for Q45 Series Photoelectric Sensors

DIN Connectors DIN06 E-03

Model Extend HDMI audio and video connections up to 300 feet. Add up to 8 additional receivers with a dedicated network switch

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

EZ-LIGHT S18L Color General-Purpose Indicators

Access Converter/ 3. Operation Manual. International Headquarters. European Headquarters. B&B Electronics. 707 Dayton Road Ottawa, IL USA

American Power Design, Inc.

Website: Tel: ADDRESS: 6475 Las Positas Rd. Livermore, CA Item No. E5B/E5S Installation Guide

Instructions. P MHz 1X/10X Passive Probe

Self--powered Time Counter

CH1 CH2 CH3 CH4. Master /Fade CH5. 600s CH6. 60s SC1 SC2 SC4 SC3 SC5. SC6 Off/Pro. AL Fade 6 Pro. User guide

Model /29S RF Splitter

3M Sensored Termination (15 kv) QX-T15I-vi1-E

USER INSTRUCTIONS MODEL CSI-200 COAXIAL SYSTEM INTERFACE

3M Locator Plate N

3M 8900 Single-mode SC Crimplok Connector

1X4 HDMI Splitter with 3D Support

Q3X Laser Contrast Sensor

Ordering Information. Self -P owered Count Totalizer H7EC. Subminiature Total Counters With Improved Appearance and Features

Small Circular Connector. JN1W / JN2W Series

AE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT

Indicator (Square) Ultra Bright LED Type

3M Mini D Ribbon (MDR) Cable Assembly

User Guide. Single-Link DVI Active Cable Extender. DVI-7171c

Industrial Ethernet Cables XS5/XS6

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

3 Cleaning. 4 Technical data

APSPB PUSH BUTTON ZERO Installation Manual

VGA Extender over Single CAT 6 Cable with Audio Support. Model Extend both video and audio up to 1000 feet

DVDO VS4 HDMI Switch. User s Guide How to install, set up, and use your new DVDO product

WLC60 Heavy Duty LED Light - PWM Dimmable

HTP1502W1 Remote Controlled Multicolor Lighting System

Children cannot always recognize potential hazards properly. This 5.1 system is not designed for operation in a heavy industry environment.

Model PSKIT-H540 Ultrasonic Power Supply Kit 40 khz 500 Watts

OPERATION AND MAINTENANCE MANUAL

User Guide. HDMI Active Cable Extender. DVI-7370c

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

SD/HD-SDI 1 to 2 Distribution Amplifier VCF-1002DA-P

CON-AUDXTRACT USER MANUAL

GEKCO SUBCARRIER REFERENCE OSCILLATOR MODEL SRO10 OPERATION/SERVICE MANUAL


CardModule. Reference Manual. Series C DA Channel SDI to CVBS Converter. Version 1.0

WIRING INSTRUCTIONS CROP-LINK Drip Installation

Solid-State Digital Timer

UTP ACTIVE TRANSCEIVER HUB

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

Enable-IT 824WP Outdoor Waterproof PoE Extender Kit Quickstart Guide Professional Grade Networking

WINEGARD INSTALLATION MANUAL. Model GM Carryout Ladder Mount for mounting pipes with outer diameters between 1 to 1-1/8

1:4 3GSDI Splitter. EXT-3GSDI-144 User Manual.

Enable-IT 821P PoE Extender Quickstart Guide Professional Grade Networking

DisplayPort Extender over 2 LC Fibers

SERIES 400 SERIES 620

Ultra Small Surface Mount Coaxial Connectors - Low Profile 1.9mm or 2.4mm Mated Height

Component Video + Analog/Digital Audio Wall Plate (6-RCA) AT80COMP7

3M Distribution Box (DDB)

TAC1 Telephone Entry System

KHT 1000C HV-Probe Calibrator. Instruction Manual

Resolution (divisions) Pre-wired Model E6F-AB3C 360P/R 2M *2 Pre-wired Connector E6F-AB3C-C 360P/R 2M *2 Model (2 m) NPN open collector BCD 360

Transcription:

Terminal Boxes XWD CSM_XWD_DS_E Simple Wiring of Sensor Actuators Greatly reduce wiring in combination with the Smartclick XS. Insert the connector and turn / of a turn to lock the connectors. Higher rated current to enable output applications. Use previous M screw connectors. Specifications Materials and Finish Rated current Rated voltage Contact resistance (connector) Insulation resistance Dielectric strength (connector) A/port, A/Box (power line) 0 to 0 VDC 0 mω max. (0 mv max., 00 ma max.),000 MΩ min. (at 00 VDC) 00 VAC for min (leakage current: ma max.) Degree of protection IP (IEC0) Insertion tolerance 0 times min. Lock strength Pulling: 00 N/ s, Twisting: N m/ s Cable holding strength 00 N/ s Lock operating force 0. to 0. N m Ambient temperature range Operating: to 0 C * *Use the robot cable within a temperature range between 0 C and 0 C to prevent the wires inside the cable from being broken when bending it. Item Contacts Fixtures Case Bushing O-ring PCB Sealing resin Cable Materials/finish Brass/nickel base, 0.-μm gold-plating Nickel-plated zinc alloy PBT resin (ULV-O), light gray Rubber Rubber Glass epoxy board Urethane resin (ULV-0) UL AWM Signal lines: AWG Power and ground lines: AWG Connection Combinations OMRON model no. Terminal Box XWD Twist-and-Click Plug s XSH, XSG, XSW (plug end), XSR (plug end) M Plug s XSH, XSG, XSW (plug end), XSR (plug end) : Connected by. : Connected by screwing. is a registered trademark of the OMRON Corporation.

XWD Ordering Information Sensor type and wiring -wire DC NPN/-wire DC - -wire DC -/without polarity - -wire DC PNP/-wire DC - Actuator wiring Actuator wiring - Actuator wiring - No. of ports No. of I/O Model XWD-P-G XWD-P-G XWD-P-G XWD-P-G XWD-P-G XWD-P-G XWD-P-G XWD-P-G Note. "-" and "-" are the connector s that are wired.. All cables are m long. Waterproof Cover (Sold Separately) Appearance Model No. per box Material XSZ- 0 PBT XSZ- 0 Brass with Ni plating Note. The XWD/XWB/XWA comes with a dust cover. If IP degree of protection is required, use the XSZ- or XSZ- (sold separately).. The XSZ- connection is threaded. Dimensions (Unit: mm) XWD-P@-G (Model with Four Ports).. dia.. dia. 000 00 0 0 0.. 0 XWD-P@-G (Model with Eight Ports). dia. dia... dia. 000 00 0 0 0.. 0

XWD XWD-P-G (Model with Four Ports and Eight I/O).. dia.. dia. 000 00 0 0 0.. 0 Wiring Diagrams Models with One I/O and One Port XWD-P@-@ for -wire NPN, -WIRE NPN -wire DC (without polarity -), and Actuator (-) XWD-P@-@ -WIRE for -wire DC (polarity -, without polarity -) Note: Cannot be used with NPN-type Photoelectric and Proximity Sensors. Cannot be used with Proximity Sensors with polarity -. XWD-P@-@ for -wire PNP, -wire DC (with polarity -), and Actuator (-) -WIRE PNP Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Signal Note. The above wiring diagrams are for eight-port use.. Figures in parentheses indicate lead colors.. The expression "white/red" means white and red stripes.. Here, "-" and "-" are s.. Contact numbers through in the above diagrams do not exist on Terminal Boxes with four ports. The lead colors for signals through,, and ground are the same.

XWD Models with Two I/O and One Port XWD-P-G for -wire NPN and Actuator (- or -) -WIRE NPN () XWD-P-G for -wire PNP and Actuator (- or -) -WIRE PNP () Signal B Signal B Signal A Signal A Signal B Signal B Signal A Signal A Signal B Signal B Signal A Signal A Signal B Signal B Signal A Signal A Note: Colors given in the connection diagram are lead colors. Mounting Dimensions (Unit: mm) Three, M or. dia. ±0. ±0. Note: The mounting dimensions are the same regardless of the number of ports. Safety Precautions Precautions for Correct Use Do not use the s in an atmosphere or environment that exceeds the specifications. Connection and Disconnection Mate the connectors according to the procedure. When mating s, be sure to insert the plug all the way to the back of the socket before attempting to lock the s. Do not use tools of any sort to mate the s. Always use your hands. Pliers or other tools may damage the s. When mating the s to XS or other M s, tighten the lock by hand to a torque of 0. to 0. N m. Confirm in the catalog that sensors and actuators are applicable before using them. Always turn OFF the before connecting or disconnecting connectors. Do not touch the mating surface of the connectors with wet hands. Wipe away any water around the connectors. Do not allow metal scraps or dust to enter the mating section. Cable Lead Polarity Connect the cables leads using the correct polarity (Blue:, Brown: ). If the polarity is not correct, the load may not operate or the operation indicator may not light. Always connect a load to the signal lines to operate a sensor or actuator. Applicable s Always mount a Waterproof Cover (XSZ-) or Dust Cover (XSZ-) to any unused connector on the Terminal Box. Power Supply and Operation Indicators The indicator will be lit green while power is being supplied. The operation indicator will be lit red while the sensor or actuator is operating. The XWD is for a DC sensor or actuator. Do not use it for an AC sensor or actuator. Terminal Boxes are available with either -wire or -wire internal connections, as indicated on the case. -WIRE NPN -WIRE -WIRE PNP -WIRE NPN () -WIRE PNP ()

Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron s sole obligation hereunder shall be, at Omron s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product. At Buyer s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ 0. In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 0 All Right Reserved.