DINTEK LAN Cabling Systems

Similar documents
Cat.6 4 Pair UTP Cable

Frequency ASRL(db) Attenuation Max. NEXT Power Sum (MHz) Minimum db/100m db/1000ft Minimum db/100m Minimum db/100m

STRUCTURED CABLING SYSTEMS (SCS)

CATEGORY 6 CABLING SOLUTIONS

Description: Pair Color Code Chart: Pair Color Chart 1 Brown White Brown 2 Orange White Orange 3 Green White Green 4 Blue White Blue.

CATEGORY 6A CABLING SOLUTIONS

CATEGORY 5e CABLING SOLUTIONS

CATEGORY 6A CABLING SOLUTIONS

STRUCTURED CABLING SOLUTIONS

TB806AUX Class E A / Cat.6A UTP Keystone Jack (Auto press-fit)

PREMIUM 5e F/UTP PRODUCTS

Tender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab*

Copper Solution Contents Cabinets Fiber Optic Solution

Clarity. Advanced solutions for 10 Gig, Category 6 and 5e copper connectivity PRODUCT SOLUTION GUIDE EXPERTISE. TECHNOLOGY. SOLUTIONS.

Multi-Media Installation Guide

Pre-terminated cabling system Modular cassette technology with 6x RJ45 C6 A ports

Compact Module. Category 6 FTP Cabling System

Dimensions. Electrical Specifications. Environmental Specifications. General Specifications. Mechanical Specifications.

ENTERPRISE COPPER SOLUTIONS

INFRASTONE BLACKSTONE 10G 6A(U/UTP) Europe, Middle East and Africa regions UNLIMITED USAGE 1

SHIELDED DIGITAL CABLES (1249C SERIES)


10G 6A F/UTP SYSTEM PRODUCTS 10G 6A F/UTP

HighBand 25. TrueNet Category 6 Solutions

...Infinite Ways to Link...

HARTING Ethernet cabling cables and connectors, 4 wire

NCB-C6SGRYR M Category 6 STP Solid Cord. Specification. Doc. Version: /09/30

APPLIANCES /// MTA, CST-100 II AND SL-156 CONNECTORS. CONNECTORS/ APPLIANCES MTA, CST-100 II and SL-156 Connectors

About Nexans 3. About Berk-Tek 4. LANmark-1000 Cat 6 UTP 5. LANmark-1000 Category 6 Plenum 6. LANmark-1000 Category 6 Riser 11

GIGALAN AUGMENTED CABLE CAT6A F/UTP 23AWGX4P LSZH

MIDDLESEX COUNTY COLLEGE WIRE AND CABLE NETWORK REQUIREMENTS BH, CB, CH, ED, MH, LH, Camera Project

Infinite ways to link... Solution Catalog

Ultra Small Surface Mount Coaxial Connectors - Low Profile 1.9mm or 2.4mm Mated Height

FLAT AND ROUND CABLE PRODUCT DESCRIPTION DESIGN ADVANTAGES. IDC Systems Cable

PATCH CORDS, PLUGS & CABLES

GenSPEED Category 5e Cables 3

System List. Structured Cabling System. In-Building RF Solution. Shield/Unshield 4pr Cable. Patch Panel. Multi-pair Cable. Patch Cord.

GIGALAN CAT.6 U/UTP 23AWGx4P - LSZH (EXP)

About Nexans 3. About Berk-Tek 4. Hyper Plus 5e Cat 5e UTP 5. HyperPlus 5e Plenum 6. Hyper Plus 5e Riser 10. HyperPlus 5e Patch 14

COLORED CATEGORY 5e BULK CABLE, SOLID-CONDUCTOR PATCH CABLE, & CATEGORY 5e BACKBONE CABLE

CAT 6 Data Wiring System Connectors

Class E A / Cat.6A Screened Coupler

CAT 6 Data Wiring System Connectors

MX5-F(XX)... Flat MAX module, T568A/B, rear strain relief cap


SMART CLASSix 24/48 UTP Patch Panels -

RJ45FC6-BLU. Base Data. Category 6 modular keystone jack - Blue - 1/bag. Article Number: Part No. RJ45FC6-BLU. Type RJ45FC6. Color.

LCS 2 RJ 45 Cat. 6A HD panels and units

MCX Miniature Coaxial Connectors

Product information 19" 1U HD Patch Panel 48xRJ45/s, Cat. 6A, gray, fully populated

August " BLANK PATCH PANEL FOR STP KEYSTONE JACKS. 19" PATCH PANEL - 24x STP CAT6A PORTS 19" BLANK PATCH PANEL FOR STP KEYSTONE JACKS

LCS2 Cat. 6 RJ 45 Patch panels and units

3M Supported Applications Map 100,000 (2005) Single-mode. Fiber. Multimode. Fiber. Copper

CAT5E NETWORK PATCH LEADS

Magic Patch Patch Leads & Accessories

GenSPEED 10 MTP Category 6A Cable An Unshielded 6A Cable with Superior Protection Against Alien Crosstalk

Ethernet Series. Etherplug Etherlink V Etherlink V Specialty Connectors Specifi cations...

Structured Cabling System. Leading Solution

Connect with the industry s best CAT6 and CAT5e channel solutions!

Non Magnetic Connectors

TB876BSX-3WH Class E A / Cat.6A STP Keystone Jack (Auto press-fit)

Volition TM RJ45 K5e Jacks

LEGRAND CABLING SYSTEM 2 PERFORMANCE FROM TECHNICAL ROOM TO WORKSTATION

Product Description. Product Specifications. Technical Specifications. Construction and Dimensions. Conductor: Insulation: Color Chart 1:

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017

6-Connector- Channel-Link Class E A (STP)

ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES

SMART CLASSix 48 UTP Patch Panels (with patching switches) -

Detailed Specifications & Technical Data

10G 6A UTP SYSTEM PRODUCTS 10G 6A UTP

Coastal Carolina University RE-BID WILLIAMS BRICE RENOVATION AND REPAIR October 19, 2018 Construction Documents

Detailed Specifications & Technical Data

Professionally Install Products Right the First Time. TOOL-CRIMP Radial Linear compression tool for BNC, F & RCA connectors

FUTURE PROOF YOUR CONNECTIONS

VERICOM GLOBAL SOLUTIONS Knoxville, Tennessee

Part Number: 7940A Cat 6 DataTuff, (4 pr) 23 AW G Solid BC, PO/PVC, EtherNet/IP, CMR, CMX-Outdoor

MTA, CST-100 II, SL-156 and AMP Economy Power (EP) Connectors. NOT the LATEST REVISION

75 Ohm BNC Male Connector Crimp/Solder Attachment for PE-B159, 1855A, Mini 59

75 Ohm N Male Connector Crimp/Solder Attachment for RG6

Detailed Specifications & Technical Data

SECTION COMMUNICATIONS HORIZONTAL CABLING

Category 6 Solutions

HDBT Installation Guide

Stainless Steel SMA Connectors Product Catalog

SPECIAL SPECIFICATION 2344 TMC Support Equipment

Coaxial Cable Termination

Belden IBDN System 10GX The next level of cabling performance

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

Solarstar Electronics Industrial Co.,Ltd. 3/F,58,Junxin Rd.,Guanlan,Longhua,Shenzhen,China

BUS UNITRONIC BUS CAN

SMA One Piece Semi-Rigid Connectors

Belden IBDN System 10GX 10GX Modules and 10GX Patch Panels

Structured Cabling Introduction & Installation Guide

Horizontal or Vertical PCB contacts Bulk Packaging LED colour - Red, Green, Yellow or Blue combinations. Ordering Codes

SECTION 7 -- CROSS-CONNECT SYSTEMS

10Gb/s Copper Physical Infrastructure Next Generation Category 6A Cabling System

Detailed Specifications & Technical Data

Indoor cabling LAN Cabling Systems

Siam Pacific Electric Wire & Cable Co., Ltd.

HELLERMANNTYTON DESCRIPTION DIMENSIONS PKG. PART NO. (HXWXD) QTY. RE18 Residential Enclosure Base: 18 H x 14.1 W x 4 D 1 Cover: 19.5 H x 15.

Transcription:

4 Pair UTP Cable Application: Voice Fast Ethernet(IEEE802.3) VgAnyLAN(IEEE 802.12) Token Ring(IEEE 802.5) TPPMD(ANSI X3T9.5) BaseT Ethernet(IEEE 802.3u) 155/622 Mbps 1.2/ 2.4 Gbps ATM 0BaseT Ethernet 550 MHz Broadband video Industry Standard: UL, ETL Verified TIA/EIA 568B.21 ISO/IEC 11801 EN 50173 Cable Data: No. of Pairs:4 Jacket Color:Gray Insulation Thickness: 0.33mm Nom.O.D.:6.5mm Flame Rating:CM Transmission quality verified up to 250MHz Product Electrical Characteristics: Impedance:±15 ohms Mutual Capacitance, max. nf/ m: 5.6 DC Resistance, max. Ohms/ m: 9.38 Capacitance Unbalance(Pair to Ground): 330pf/ m max. P/N Description Jacket Color Std Pkg Qty 110104001 Cat.6, 4P, UTP, 23AWG, Solid PVC Gray 305M/reel in a box 110104004 Cat.6, 4P, UTP, 23AWG, Solid PVC Gray 305M/ Pull box For LSZH requirements, please contact us. Frequency Attenuation Max. NEXT Power Sum ELFEXT (MHz) db/m db/m Minimum db/m (db/ m) 1 2.0 74.3 72.3 67.8 4 3.8 65.3 63.3 55.8 10 6.0 59.3 57.3 47.8 16 7.6 56.2 54.2 43.7 20 8.5 54.8 52.8 41.8 31.25 10.7 51.9 49.9 37.9 62.5 15.4 47.4 45.4 31.9 19.8 44.3 42.3 27.8 200 29.0 39.8 37.8 21.8 250 32.8 38.3 36.3 19.8 1

UTP Patch Cord Application: Voice Fast Ethernet(IEEE802.3) VgAnyLAN(IEEE 802.12) Token Ring(IEEE 802.5) TPPMD(ANSI X3T9.5) BaseT Ethernet(IEEE 802.3u) 155/622 Mbps 1.2/ 2.4 Gbps ATM 0BaseT Ethernet 550 MHz Broadband video Product Description: Molded boots prevent pin from bending and cables from kinking Fully tested to meet TIA/EIA568B.21 Category 6 requirements Stranded 24AWG wires provides maximum flexibility ETL verified to EIA/ TIA568B specifications UL listed Wiring: T568B Industry Standard: UL, ETL Verified TIA/EIA 568B.21 ISO/IEC 11801 EN 50173 Prevent from broken on spring leaf of plug Stackable design for high density modular jack P/N Description Length(M) Color Std Pkg Qty 120104032 Cat.6 4 pair UTP patch cord 1 Gray 10 120104038 Cat.6 4 pair UTP patch cord 2 Gray 10 120104044 Cat.6 4 pair UTP patch cord 3 Gray 10 120104050 Cat.6 4 pair UTP patch cord 5 Gray 10 Please contact us for any customized requirements. 2

19 Patch Panel 110 Enhanced Cat.6 Patch Panel: UL Listed & Verified. High performance, exceeds TIA/EIA 568B.21 Category 6 Hardware transmission performance 110 and Krone dual type IDC termination 19 24 port patch panel, 1U size & 48 port panel, 2U size Accepts 2226 AWG, stranded or solid wire Wiring:T568A/ B Optional rear cable manager Highlow contact design improves transmission performance IDC connector with large spacer for each pair to improve crosstalk Press fit IDC connector terminal for high frequency application P/N Description Std. Ctn. Qty 140204010 Cat.6 19 110/ krone dual type Patch Panel 24 ports, 1U size Component level 25 140204001 Cat.6 19 110/ krone dual type Patch Panel 24 ports, 1U size Channel level 25 140204003 Cat.6 19 110/ krone dual type Patch Panel 48 ports, 2U size Channel level 10 149900001 19 Rear cable management 45 Installing the wire management Step 1. Align the tongue of the minder with the corresponding groove on the patch panel and insert it into the groove. Step 2. After installing two jacks, use a tie wrap to attach wires to the wire manager. Do not over tighten the tie wrap! It crushes the wires. Continue this until all the jacks have been installed. 3

Keystone Jack Industry Standard: UL Listed & Verified. High performance, exceeds TIA/EIA 568B.21 Category 6 Hardware transmission performance Meets FCC parts 68 ANSI/TIA/ EIA568B ISO/IEC 11801 Physical: IDC connector accepts 2226 AWG solid wire Jack wiring:50 u gold plated over u nickel Housing:High impact flame retardant plastic UL94V0 rated IDC connector suitable for 110 punch down and Krone tool Mechanical: Plug insertion life:750 cycle min. Plug retention force:30 lbs min. Electrical: Current rating:1.5 Amps Insulation resistance:500megaohms min. Contact resistance:20 milliohms max. DC resistance:0.1 ohms max. Data transmission rates up to 250Mbps IDC connector with large space between each pair to improve crosstalk Press fit IDC connector terminal for high frequency application P/N Description Std Pkg Qty Std Ctn Qty 130504012 Cat.6 110/ Krone horizontal type Keystone Jack, T568A/ B Component level 400 130504002 Cat.6 110/ Krone horizontal type Keystone Jack, T568A/B Channel level 400 130504013 Cat.6 110/ Krone vertical type Keystone Jack, T568A/ B Component level 400 130504003 Cat.6 110/ Krone vertical type Keystone Jack, T568A/ B Channel level 400 Channel passive performance test configuration ETL & 3P verified 4

110 CrossConnect Block Exceeds TIA/EIA 568B.21 category 6 standard Ideal for use in cross connections and consolidation point applications Highly visible colorcoded wiring slots for easy wiring Mounts to standard TIA/EIA 19 racks Available with or without mounting legs for a variety of mounting options Can be terminated with single or multiple position punch down tools Large space between each pair to improve crosstalk Colorcoded design for easy wiring P/N Description Std. Ctn. Qty 180206 Cat.6 Wiring blocks w/o mounting legs, w/ 48pair 180202003 Cat.6 Wiring blocks w/o mounting legs, w/ 96pair 180204001 Cat.6 Wiring blocks w/o mounting legs, w/ 288pair 180104 Cat.6 Wiring blocks w/mounting legs, w/ 48pair 180102004 Cat.6 Wiring blocks w/mounting legs, w/ 96pair 180104001 Cat.6 Wiring blocks w/mounting legs, w/ 288pair 180403003 Cat.6 connecting blocks 4 pair 5

4 Pair SSTP Cable Application: Voice Fast Ethernet(IEEE802.3) VgAnyLAN(IEEE 802.12) Token Ring(IEEE 802.5) TPPMD(ANSI X3T9.5) BaseT Ethernet(IEEE 802.3u) 155/622 Mbps 1.2/ 2.4 Gbps ATM 0BaseT Ethernet 550 MHz Broadband video Industry Standard: UL444 communication cables standard, UL AWM style 2835 TIA/EIA 568B.21 Product Electrical Characteristics: Impedance:±15 ohms Mutual Capacitance: nom. 13.6pf/ft DC Resistance: max. 6.8ohm/m at 20 C Voltage rating: 30V Rated temperature: 60 C Cable Data: No. of Pairs:4 pair Size of conductor: 23AWG (solid anneal copper wire) Overall Diameter:7.4±0.3mm Individual Shielding: Aluminumfoil laminated tape. Overall Shielding: Tinned copper wire braiding. Jacket material: PVC or LSZH, flame retardant and/or CM grade. P/N Description Jacket Std Pkg Qty 110704001 Cat.6 4P SSTP with braiding 23AWG solid cable PVC 305m (1,000ft) /reel 110704004 Cat.6 4P SSTP without braiding 23AWG solid cable PVC 305m (1,000ft) /reel For LSZH requirements, please contact us. Frequency Attenuation Max. NEXT PSNEXT ELFEXT PSELFEXT Return Loss (MHz) db/m db/m Min. db/m (db/ m) (db/ m) (db/ m) 1 2.0 74.3 72.3 67.8 64.8 20.0 4 3.8 65.3 63.3 55.7 52.7 23.0 8 5.3 60.8 58.8 49.7 46.7 24.5 10 6.0 59.3 57.3 47.8 44.8 25.0 16 7.6 56.3 54.3 43.7 40.7 25.0 20 8.5 54.8 52.8 41.7 38.7 25.0 25 9.5 53.4 51.4 39.8 36.8 24.3 31.25 10.7 51.9 49.9 37.9 34.9 23.6 62.5 15.4 47.4 45.4 31.8 28.8 21.5 19.9 44.3 42.3 27.8 24.8 20.1 200 28.98 39.8 37.8 21.7 18.7 18.0 250 32.85 38.4 36.4 19.8 16.8 17.3 6

SSTP Patch Cord Application: Voice Fast Ethernet(IEEE802.3) VgAnyLAN(IEEE 802.12) Token Ring(IEEE 802.5) TPPMD(ANSI X3T9.5) BaseT Ethernet(IEEE 802.3u) 155/622 Mbps 1.2/ 2.4 Gbps ATM 0BaseT Ethernet 550 MHz Broadband video Industry Standard: UL444 communication cables standard, UL AWM style 2835 TIA/EIA 568B.21 ISO/IEC 11801 Cable Data: No. of pairs: 4 Size of conductor: 26AWG (Stranded Anneal copper wire) Dielectric material: Foamed P.E Diameter of Dielectric core: 1.0±0.05mm Individual Shielding:Aluminumfoil laminated tape Overall Shielding: Tinned copper wire braiding, normal with min. 65% coverage. Jacket: PVC, flame retardant CM grade O.D.: 5.7±0.2mm Product Description: Molded boots prevent pin from bending and cables from kinking Fully tested to meet TIA/EIA568B.21 category 6 requirements 50u gold plating on RJ45 plug contacts. Durability: 750 cycles min. Wiring: T568B P/N Description Length(M) Color Std Pkg Qty 120104022 Cat.6 4P SSTP patch cord 1 Gray 10 120104023 Cat.6 4P SSTP patch cord 2 Gray 10 120104024 Cat.6 4P SSTP patch cord 3 Gray 10 120104025 Cat.6 4P SSTP patch cord 5 Gray 10 Please contact us for any customized requirements. Cat.6 shielded channel performance 3P verified 7

Fully Shielded 19 Patch Panel Features: High performance, meets all Cat.6 channel link requirements specifed in TIA/EIA568B.21 % shielded for complete EMI/RFI protection 19 24port patch panel, 1U size. 110 and Krone dual type IDC termination Accepts 2226AWG, Stranded or solid wire Wiring: T568A/B Electrical: Insulation resistance: 10 Mega ohms min. Dielectric with standing voltage: 1,000 Volts, RMS, 60Hz, 1min. Contact resistance: 20 milli ohms max. Current rating: 1.5 AMPS at 20 C Physical: Housing: Highimpact, flameretardant plastic,ul94v0 rated. Material: Phosphor Bronze Alloy. Plating: 50u gold plated over u nickel. Sheel: Brass alloy plated with u nickel. Plate: SPCCSD 16G. Mechanical: Total mating force: 800 grams for a 8 wire leads min. Retention: 30 lbs min between the jack and plug. Insertion/Extraction life: 750 cycles min. Number of IDC terminations: 200 cycles min. Grounding lock 8 in 1 module 9 position IDC termination with spring wire/contact blades and includes the ninth slot for the drain wire. P/N Description Std. Ctn. Qty 140204004 Cat.6 19 110/Krone type fully shielded patch panel 24 ports, 1U size 10 8

Fully Shielded 19 Patch Panel install instruction Step 1. Strip approximately 7.7cm of the jacket from the cable. Be sure that the foil and/or braid remains intact. Step 2. For cable with foil but no braid: Fold the foil shield back over the jacket of the cable. For braided cable: Slide the braid back over the wire, wrap jacket and,if there is a drain wire,wrap it around the braid close to the fold at least 3 times (See Step 5 for alternative drain wire instruction) Step 3. For cable with foil but no braid: Wrap the drain wire around the foil shield. Do not wrap the drain wire more than 1.3cm from the fold in the foil shield. (See step 5 for alternative drain wire instruction). For braided cable: Unwrap the foil that extends beyond the jacket from each pair and cut it off. Step 6. Fasten the cable to the strain relief tabs with cable ties and trim off the excess cable tie. Step 5. Instead of wrapping the drain wire around the foil shield, the drain wire may be inserted into the ninth slot (the slot with no color code) on the IDC connecting block as shown. Step 4. For braided cables: Insert the cable though the ground clip as shown. Step 7. Tighten the ground clip screw until it reaches the bottom. Ensure that there is no foil in contact with the ground clip. Step 8. Press the wires into the IDC connecting blocks according to the color code on the blocks. Punch the wires down with an impact tool in order to terminate them. Do not forget to teminate the drain wire if it has been inserted into the ninth slot. Step 9. Slide the rear cover into place and lock it into position by clasping the two plastic buttons. Attach a g r o u n d w i r e f r o m the ground lug to a grounding device. 9

Fully Shielded Keystone Jack Transmission performance: Meets cat.6 channel performance requirements specified in TIA/EIA568B.21 Mechanical: Total mating force: 800 grams for a 8 wire leads minimum. Retention: 30lbs min between the jack and plug. Insertion/Extraction life: 750 cycles min. Number of IDC terminations:200 cycles min. Electrical: Electrical insulation resistance: 10 mega ohms min. Dielectric with standing voltage: 1,000 V, RMS, 60Hz, 1min. Contact resistance: 20 milli ohms max. Current rating: 1.5 AMPS at 20 C Physical: Housing: Highimpact, flameretardant plastic, UL94V0 rated. Spring wire/contact blades: Material: Phosphor Bronze alloy. Plating: 50u gold plated over u nickel. Shell: Brass alloy plated with u nickel. P/N Description Std Pkg Qty Std Ctn Qty 130504006 Cat.6 110/ Krone horizontal type fully shielded keystone Jack, T568A/ B 200 130504007 Cat.6 110/ Krone vertical type fully shielded keystone Jack, T568A/ B 200 Horizonal fully shielded keystone jack installion step Step 1. Step 2. Step 3. Step 4. Step 5. ground wire Vertical fully shielded keystone jack installion step Step 1. Step 2. Step 3. Step 4. Step 5. Wrap with tape Wrap with copper foil tape 10