DirectOut Technologies

Similar documents
DirectOut Technologies

DirectOut Technologies

ANDIAMO 2.DA. Hardware Guide. Version 2.0

3G/HD/SD-SDI to HDMI Converter

User Manual TL-2X1-HDVC 2x1 HDMI & VGA Switcher with Control All Rights Reserved Version: TL-2X1-HDVC_160630

TR6102HD HDTV/DVD/COMPONENT VIDEO TO RGBHV TRANSCODER USER S GUIDE

User Manual TL-2X1-HDV 2x1 HDMI & VGA Switcher All Rights Reserved Version: TL-2X1-HDV_160630

DA1909 COMPUTER VIDEO LINE DRIVER WITH EQUALIZATION USER S GUIDE

User Manual CVA3. HDMI Audio Decoder. All Rights Reserved. Version: CVA3_2016V1.0

PT-C-HDADE. User Manual. HDMI Audio De-Embedder 4K (60Hz 4:4:4) Model PT-C-HDADE. Designed in Germany

8 Port HD/SD-SDI Video Switch with 2 Port Splitter

VLHDMIEXTFIB_2017V1.0

USERS GUIDE MCX-HTS. HDMI to 3G SDI Converter. Manual Number:

User Manual PS-684. HDBaseT Extender Kit 70m. All Rights Reserved. Version: UHBT70P_2016V1.2

User's Guide. MADI Converter. 6 x Bidirectional MADI Optical to BNC Converter

.Power Distribution Center. PD-1. Instruction Manual

DA IN 1-OUT LINE DRIVER WITH EQUALIZATION + AUDIO USER S GUIDE

8 Port HD/SD-SDI Switch

HD/SD-SDI Over Fiber Transmitter and Receiver Extender Kit. User Manual L-1SDI-SFE-TX/RX

User Manual TP70L. HDBaseT Extender. All Rights Reserved. Version: TP70L2016V1.1

User Guide FA

DISTRIBUTION AMPLIFIER

ml:mio manual universal. flexible. independent.

User Manual. Model 979T and 979R Digital Audio Converters

User's Guide. Time Code Option. for HDSP / HDSPe / Fireface 800

PRO-HDMI2HD. HDMI to SDI/3G-HD-SD Converter. User Manual. Made in Taiwan

Manual FERROFISH A16 MK-II. advanced audio applications. professional 16 channel AD/DA converter

User Guide. Single-Link DVI Active Cable Extender. DVI-7171c

VGA & RS232 Extender SET over Single CAT5 with RGB Delay Control

ENGLISH Antenna Distributor

VGA, Audio & RS232 Extender SET over Single CAT5 with RGB Delay Control & IR Pass Through

VGA & Audio Receiver SET over Single CAT5 with RGB Delay Control

VGA / Audio Extender Single CAT5 / CAT6 with RGB Delay Control & EQ

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 PNP202. Interconnect Box USER'S GUIDE

VGA to DVI Extender over Fiber SET

GPS4000. GPS Time Receiver System. User Manual Version 1.1. World Time Solutions. World Time Solutions Limited

KHT 1000C HV-Probe Calibrator. Instruction Manual

ASP-FIBRS1 User Manual

4, 8, 16 Port VGA and Audio Extender / Splitter with Audio over Single CAT5

1x4, 1x8, 1x12, 1x16 VGA Extender / Splitter over Single CAT5

NECT 540 U CONNECT 540 UHD USER MANUAL 3 GEBRAUCHSANLEITUNG GUIDE UTILISATEUR MODO DE EMPLEO MANUALE D ISTRUZIONI GEBRUIKSAANWIJZING

ACTIVE IF SPLITTER/COMBINER UHP-IFS

4, 8, 16 Port VGA/ Audio Extender / Splitter With Local Output with SPDIF Model #: VGA-C5SP-8

Connect 350 UHD. Connect 350 UHD USER MANUAL 3 GEBRAUCHSANLEITUNG GUIDE UTILISATEUR MODO DE EMPLEO MANUALE D ISTRUZIONI GEBRUIKSAANWIJZING

Table of Contents FCC COMPLIANCE STATEMENT... 4 WARNINGS AND PRECAUTIONS... 4 WARRANTY... 5 STANDARD WARRANTY... 5 TWO YEAR WARRANTY... 5 DISPOSAL...

TBC & Matrix Switcher TBC-5000 Instruction Manual

TV Connector user guide

SyncGen. User s Manual

MSF1000. MSF Radio Time Code Receiver. User Manual Version 1.1. World Time Solutions. World Time Solutions Limited

AVMU2-BHD+/3G Audio monitoring Unit

ASH - EOC-01. Ethernet Over Coax Adapter User Guide

4-PROJECTOR BAR WITH 3 X 9W LEDS AND 1 X 1W FLASH LED USER GUIDE

Model 7600 HD/SD Embedder/ Disembedder Data Pack

User Manual TL-TP70-HDIR 70m Extender with ARC and IR All Rights Reserved Version: TL-TP70-HDIR_180723

Warnings and Precautions

AMU2-2MHD+ Audio monitoring Unit

User Manual TPHD-BYE. HDBaseT Extender Set 70m. All Rights Reserved. Version: TPHD-BYE_2014V1.0

TVAC20000 User manual

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

4 Channel HD SDI Over Fiber Transmitter and Reciever Extender with RS 485 Channel User Manual L-4SDI-FE-HD-TX/RX

SK2002DA SIDEKICKER 1-IN, 2-OUT VGA-UXGA DISTRIBUTION AMPLIFIER CABLE USER S GUIDE DISTRIBUTION AMPLIFIERS

User Manual MDVR8041. User Manual. Mobile DVR MDVR Digital Video Recorder. Copyright , Meriva Security All Rights Reserved

CON-AUDXTRACT USER MANUAL

ACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 TNP100. Tilt N Plug Interconnect Box USER'S GUIDE

SAFETY AND NOTICE TABLE OF CONTENTS

LINE DRIVERS MANUAL PART NUMBER: DA3000TM0 1-IN, 1-OUT COMPOSITE VIDEO + AUDIO LINE DRIVER TABLE MOUNT USER S GUIDE

VGAD-12 ORDERCODE

Instructions for Use P.154-UP (9/4) P.155-UP (9/8) P.150-UP-12 (9/12) P.150-UP-16 (9/16)

User Manual HD-70X. HDMI Twisted Pair PoC Extender. over Single Twisted Pair. All Rights Reserved. Version: HD-70X_2016V1.

Concert Series ORDERCODE D3470 ORDERCODE D3471 ORDERCODE D3472 D3470 D3471 D3472

LA1500R USER S GUIDE.

PRO-CoaxExt HDMI extender over Coaxial cable with bi-directional IR User s Guide

User Manual TP70P. HDBaseT Extender Set 70m. All Rights Reserved. Version: TP70P_2016V1.0

CV-005B. Mini Component to HDMI Converter. User Manual. Made in Taiwan

SAFETY INFORMATION. 7. Do not force switched or external connections in any way. They should all connect easily, without needing to be forced.

HDMI 5x1 Switch B-240-HDSWTCH-5X1 INSTALLATION MANUAL

Contents. Disclaimer of Product and Services Warnings and Precautions Standard Warranty Two Year Warranty Introduction...

Introduction Front Panel Functions Rear Panel Functions Precautions Placement & Ventilation... 5

User Manual TPU421. Ultra-thin HDBaseT Extender. All Rights Reserved. Version: TPU421_2016V1.0

TECHCONNECT OWNERS MANUAL

User Manual POE. Twisted Pair POE Extender

EXT-HBT70-SET_2016V1.2

*Prefer. 600 MHz 4K ULTRA. 60Hz, 4:4:4. over one SC-Terminated Fiber-Optic Cable EXT-DP-4K600-1SC. User Manual. Release A1

LINK EXT40-4KECO. 4K 40m HDMI Extender. User Manual. Version: V1.0.1

AMU1-BHD+ Audio monitoring Unit

Tube Rotator. User Guide. Version 1.2

Contents. Disclaimer of Product and Services

User Manual TP422P-4K. Ultra-thin HDBaseT Extender. All Rights Reserved. Version: TP422P-4K_2016V1.1

User Manual For X3-H0402 MDVR. Mobile Digital Video Recorder. User manual for X3-H0402

OWNER'S MANUAL MYCRO SUB

HDMI 1.3 Receiver over Signal. CAT5/CAT6 Cable. Model #: HDMI-C5-R-M. 1

4K UHD HDMI 2CH/5.1CH

AN2 Series. 900tvl. CMOS Technology High Resolution Sensor. elinetechnology.com P/N 01.BSM V1.0

User's Guide AO4S-192 AIO

User Manual. Model 1372A and 1374A HDMI Switchers. 1T-SX-632 Model 1372A 2X1 Switcher. v1.3 2x1 SWITCHER. v1.3 INPUT ENHANCE POWER

VGA / Audio Extender Single CAT5 / CAT6 with RGB Delay Control & EQ

Installation Guide. HDMI 4x1 Switcher

Transvue HDMI 4K2K Scaler

Passive Four Channel Stereo/Mono Mixer/Splitter. Artcessories. User's Manual

Transcription:

DirectOut Technologies D.O.TEC EXBOX.ADAT Manual Version 1.1

DirectOut Technologies Copyright Note Copyright All rights reserved. Permission to reprint or electronically reproduce any document or graphic in whole or in part for any reason is expressly prohibited, unless prior written consent is obtained from the DirectOut GmbH. All trademarks and registered trademarks belong to their respective owners. It cannot be guaranteed that all product names, products, trademarks, requisitions, regulations, guidelines, specifications and norms are free from trade mark rights of third parties. All entries in this document have been thoroughly checked; however no guarantee for correctness can be given. DirectOut GmbH cannot be held responsible for any misleading or incorrect information provided throughout this manual. DirectOut GmbH reserves the right to change specifications at any time without notice. DirectOut Technologies and D.O.TEC are registered trademarks of the DirectOut GmbH. ADAT optical is a trademark of Alesis Corporation. DirectOut GmbH, 2012 DirectOut GmbH D.O.TEC EXBOX.ADAT Manual Version 1.1 page 3 of 39

Table of Contents DirectOut Technologies Table of contents About This Manual 7 How to Use This Manual 7 Conventions 7 Chapter 1: Overview 8 Introduction 8 Applications 9 How it works 9 Feature Summary 10 Chapter 2: Legal issues & facts 11 Before Installing This Device 11 Defective Parts/Modules 12 First Aid (in case of electric shock) 13 Contents 14 Updates 14 Intended Operation 14 Conditions of Warranty 15 Conformity & Certificates 16 Contact 17 Chapter 3: Installation 18 Installing the Device 18 Chapter 4: Operation 21 Introduction 21 Rear Panel - Power supply 21 Front Panel - Input / Output 22 Rear Panel - Input / Output 23 page 4 of 39 D.O.TEC EXBOX.ADAT Manual Version 1.1 DirectOut GmbH

DirectOut Technologies Table of Contents Clocking 25 Userbits 26 Format detection 26 Routing 27 Chapter 5: Application Examples 29 Introduction 29 Example 1: ADAT / MADI frontend 29 Example 2: Backup recording 30 Example 3: Inserting into MADI 31 Chapter 6: Troubleshooting and Maintenance 32 Troubleshooting 32 Maintenance 33 Technical Data 34 Appendix A - Wiring Sketch 36 Hirose HR10 (DC PSU) 36 Index 37 DirectOut GmbH D.O.TEC EXBOX.ADAT Manual Version 1.1 page 5 of 39

DirectOut Technologies This page is left blank intentionally. page 6 of 39 D.O.TEC EXBOX.ADAT Manual Version 1.1 DirectOut GmbH

DirectOut Technologies About This Manual About this Manual how to use this Manual This manual guides you through the installation and operation of the EXBOX.ADAT. Use the Table of Contents at the beginning of the manual or Index Directory (page 37) to locate help on a particular topic. You can access more information and latest news by visiting on the DirectOut website at www.directout.eu. Conventions The following symbols are used to draw your attention to: tips indicate useful tips and short cuts. notes are used for important points of clarification or cross references. warning Warnings alert you when an action should always be observed. DirectOut GmbH D.O.TEC EXBOX.ADAT Manual Version 1.1 page 7 of 39

Chapter 1: Overview DirectOut Technologies Chapter 1: Overview Introduction Welcome to the EXBOX.ADAT, D.O.TEC s MADI/ADAT converter: The EXBOX.ADAT converts MADI signals to ADAT signals and vice versa from ADAT to MADI. It provides the following interfaces: Standard MADI I/O (coaxial, BNC) Standard MADI I/O (optical, SC) 8 x ADAT I/Os (TOSLink) page 8 of 39 D.O.TEC EXBOX.ADAT Manual Version 1.1 DirectOut GmbH

DirectOut Technologies Chapter 1: Overview Applications The EXBOX.ADAT can be used for conversion of MADI signals (AES10) to ADAT signals and vice versa. By looping one or more ADAT ports it is also possible to split / re-route a MADI signal. Typical applications include: ADAT frontend for a MADI setup splitting / conversion of MADI signals How it works The MADI input signal is routed to the eight ADAT output ports. The input signal of the eight ADAT ports is output at both MADI outputs. Each direction may use its own clock source (DualSync ). The MADI input that locks first will be used as signal and sync source for conversion. The first ADAT port (in ascending order) that locks to a signal is used as sync source for the MADI output. DirectOut GmbH D.O.TEC EXBOX.ADAT Manual Version 1.1 page 9 of 39

Chapter 1: Overview DirectOut Technologies Feature Summary MADI ports: 1 x MADI (coaxial, BNC 75 Ω) 1 x MADI (optical, SC multi/single mode) 8 x ADAT (TOSLink) MADI formats 56/64 channel, 48k/96k Frame, S/MUX 2/4 Sample rates 44.1, 48, 88.2, 96, 176.4, 192 khz +/-12.5% Power supply external, 2 x Hirose connector (9-24 V) page 10 of 39 D.O.TEC EXBOX.ADAT Manual Version 1.1 DirectOut GmbH

DirectOut Technologies Chapter 2: Legal issues & facts Chapter 2: legal issues & facts before installing this device warning Please read and observe ALL of the following notes before installing this product: Check the hardware device for transport damage. Any devices showing signs of mechanical damage or damage from the spillage of liquids MUST NOT be connected to the mains supply, or disconnected from the mains immediately by pulling out the power lead. All devices MUST be connected to the mains using the three-cord power leads supplied with the system. Only supply electrical interfaces with the voltages and signals described in these instructions. Do NOT use the device at extreme temperatures. Proper operation can only be guaranteed between temperatures of 5º C and 45º C and a maximum relative humidity of 80 %, non-condensing. The cabinet of the device will heat up. Do NOT place the device close to heat sources (e.g. heaters). Observe the environmental conditions. DirectOut GmbH D.O.TEC EXBOX.ADAT Manual Version 1.1 page 11 of 39

Chapter 2: Legal issues & facts DirectOut Technologies defective parts/modules warning This device contains no user-serviceable parts. Therefore do NOT open the device. In the event of a hardware defect, please send the device to your local service representative together with a detailed description of the fault. We would like to remind you to please check carefully whether the failure is caused by erroneous confi guration, operation or connection before sending parts in for repair. See Chapter 6: Troubleshooting and Maintenance on page 32 for assistance with troubleshooting. page 12 of 39 D.O.TEC EXBOX.ADAT Manual Version 1.1 DirectOut GmbH

DirectOut Technologies Chapter 2: Legal issues & facts first Aid (in case of electric shock) warning DO NOT touch the person or his/her clothing before power is turned off, otherwise you risk sustaining an electric shock yourself. Separate the person as quickly as possible from the electric power source as follows: Switch off the equipment. Unplug or disconnect the mains cable. Move the person away from the power source by using dry insulating material (such as wood or plastic). If the person is unconscious: Check their pulse and reanimate if their respiration is poor. Lay the body down and turn it to one side. Call for a doctor immediately. Having sustained an electric shock, ALWAYS consult a doctor. DirectOut GmbH D.O.TEC EXBOX.ADAT Manual Version 1.1 page 13 of 39

Chapter 2: Legal issues & facts DirectOut Technologies Contents The contents of your EXBOX.ADAT package should include: 1 x EXBOX.ADAT 1 x external power supply unit (9-24 V) 1 x Manual updates D.O.TEC products are continually under development, and therefore the information in this manual may be superseded by new releases. To access the latest documentation, please visit the DirectOut website: www.directout.eu. intended operation The exbox.adat is designed for conversion between ADAT and MADI signals (AES10). warning No compensation can be claimed for damages caused by operation of this unit other than for the intended use described above. Consecutive damages are also excluded explicitly. The general terms and conditions of business of DirectOut GmbH are applied. page 14 of 39 D.O.TEC EXBOX.ADAT Manual Version 1.1 DirectOut GmbH

DirectOut Technologies Chapter 2: Legal issues & facts Conditions of warranty This unit has been designed and examined carefully by the manufacturer and complies with actual norms and directives. Warranty is granted by DirectOut GmbH over the period of two years for all components that are essential for proper and intended operation of the device. The date of purchase is applied for this period. warning All claims of warranty will expire once the device has been opened or modified, or if instructions and warnings were ignored. For warranty claims please contact the dealer where your device was acquired. DirectOut GmbH D.O.TEC EXBOX.ADAT Manual Version 1.1 page 15 of 39

Chapter 2: Legal issues & facts DirectOut Technologies Conformity & Certificates Ce This device complies with the basic requests of applicable EU guidelines. The appropriate procedure for approval has been carried out. rohs (Restriction of the use of certain Hazardous Substances) This device was constructed fulfilling the directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment 2002/95/EC. weee (Directive on Waste Electrical and Electronic Equipment) Due to the directive 2002/96/EC for waste disposal this device must be recycled. For correct recycling please dispatch the device to: IMM Elektronik GmbH, Leipziger Strasse 32 09648 Mittweida, Germany Only stamped parcels will be accepted! WEEE-Reg.-No. DE 93924963 page 16 of 39 D.O.TEC EXBOX.ADAT Manual Version 1.1 DirectOut GmbH

DirectOut Technologies Chapter 2: Legal issues & facts Contact Sales: DirectOut GmbH, Leipziger Strasse 32, 09648 Mittweida, Germany Phone: +49 (0)3727 6205-333 Fax: +49 (0)3727 6205-56 www.directout.eu Manufacturer: IMM Elektronik GmbH, Leipziger Strasse 32, 09648 Mittweida, Germany Phone: +49 (0)3727 6205-0 Fax: +49 (0)3727 6205-56 www.imm-gruppe.de DirectOut GmbH D.O.TEC EXBOX.ADAT Manual Version 1.1 page 17 of 39

Chapter 3: Installation DirectOut Technologies Chapter 3: installation installing the device 1. Open the packaging and check that the contents have been delivered complete and undamaged. 2. Place the device on a non-slip horizontal surface. The delivered pads may be affi xed to the bottom of the cabinet. Watch a clean and dry surface before affi xing the pads. warning The synthetics of the delivered pads might cause stains on damageable surfaces. To avoid staining of furniture surfaces it is recommended to place a protective plate under the device. warning Avoid damage from condensation by waiting for the device to adapt to the environmental temperature. Proper operation can only be guaranteed between temperatures of 5º C and 45º C and a maximum relative humidity of 80%, non-condensing. Ensure that the unit has sufficient air circulation for cooling. page 18 of 39 D.O.TEC EXBOX.ADAT Manual Version 1.1 DirectOut GmbH

DirectOut Technologies Chapter 3: Installation 3. Using the power cord of the external power supply provided, connect the device to a matching power supply and connect the output of the power supply to the Hirose connectors at the rear panel. This device may operate with only one power supply. To provide power supply redundancy, it is recommended to connect both PSU 1 and PSU 2 to independent power supplies with separate fuses. The shipment includes one external power supply unit. Additional power supply units are available from your local D.O.TEC representative. warning The external power supply MUST be connected to the mains using the three-cord power leads supplied with the device. Only supply the voltages and signals indicated (9-24 V DC) to the device. warning The connected power supply must provide a current limiting to a maximum of 2.5 A. DirectOut GmbH D.O.TEC EXBOX.ADAT Manual Version 1.1 page 19 of 39

Chapter 3: Installation DirectOut Technologies 4. Remove the protective cap from the optical MADI port before use: Retain the protective cap if the optical port is unused. This will protect against soiling which can lead to malfunction. 5. Connect the ADAT and MADI signals to the device: ADAT IN/OUT TOSLink connectors MADI IN/OUT coaxial or optical connectors Keep any packaging in order to protect the device should it need to be dispatched for service. page 20 of 39 D.O.TEC EXBOX.ADAT Manual Version 1.1 DirectOut GmbH

DirectOut Technologies Chapter 4: Operation Chapter 4: operation introduction This chapter describes the basic operation of the device. Note that throughout this manual, the abbreviation FS refers to sample rate or sample frequency. So, when dealing with scaling factors, the following sample rates can be written as: 44.1 khz = 1 FS; 88.2 khz = 2 FS; 176,4 khz = 4 FS or 48 khz = 1 FS; 96 khz = 2 FS; 192 khz = 4 FS rear panel - power supply psu 1 psu 2 hirose socket Connect the power supply here (9 V - 24 V). hirose socket Connect the power supply here (9 V - 24 V). The device does not provide a power switch. Connecting a working power supply to the device will power up the device immediately. DirectOut GmbH D.O.TEC EXBOX.ADAT Manual Version 1.1 page 21 of 39

Chapter 4: Operation DirectOut Technologies Front Panel - Input / Output ADAT IN (ports 1 to 8) ADAT OUT (ports 1 to 8) LED Sync (ports 1 to 8) TOSLink sockets Connect here ADAT input signals. Conversion ADAT to MADI TOSLink sockets Connect here ADAT output signals. Conversion MADI to ADAT This LED indicates the use of the ADAT input and its lock status. LED OFF = no signal LED blinking = signal present (LOCK) LED ON = signal is in sync with clock source (SYNC) The EXBOX.ADAT detects whether a valid signal is fed to the ADAT inputs. A LED indicates the status of each input discretely. If no signal is connected to any of the ADAT inputs, the Sync LEDs show a running light to indicate that the device is in operation. page 22 of 39 D.O.TEC EXBOX.ADAT Manual Version 1.1 DirectOut GmbH

DirectOut Technologies Chapter 4: Operation Rear Panel - Input / Output MADI 1 OUT MADI 1 IN MADI 2 OUT MADI 2 IN SC socket (optical) MADI output - connect here MADI output signal SC socket (optical) MADI input - connect here MADI input signal BNC socket (coaxial) MADI output - connect here MADI output signal BNC socket (coaxial) MADI input - connect here MADI input signal DirectOut GmbH D.O.TEC EXBOX.ADAT Manual Version 1.1 page 23 of 39

Chapter 4: Operation DirectOut Technologies The EXBOX.ADAT detects whether a valid signal is fed to the MADI inputs. A LED indicates the status of each input discretely. LED Sync (MADI 1) LED Sync (MADI 2) This LED indicates the use of the MADI 1 input and its lock status. LED OFF = no signal LED blinking = signal present (LOCK) LED ON = input is used as clock and input source (SYNC) This LED indicates the use of the MADI 2 input and its lock status. LED OFF = no signal LED blinking = signal present (LOCK) LED ON = input is used as clock and input source (SYNC) If both MADI inputs are connected the LED of the unused input will glow with a reduced intensity. The MADI input that locks first will be used as signal and sync source for conversion. page 24 of 39 D.O.TEC EXBOX.ADAT Manual Version 1.1 DirectOut GmbH

DirectOut Technologies Chapter 4: Operation Clocking Both directions of conversion may use their own clock source - D.O.TEC DualSync. That means that an ADAT port is used as clock source for conversion from ADAT to MADI and a MADI port is used as clock (and input) source for conversion from MADI to ADAT. The selection of the ADAT port as clock source uses the following pattern in ascending order: lowest input port receiving a valid ADAT signal If no ADAT input detects a valid input signal, the MADI input is used. A change of the ADAT input signal condition may result in a different clock source. The MADI input that locks fi rst will be used as signal and sync source for conversion. D.O.TEC DualSync : output MADI ADAT Clock source lowest input port receiving a valid ADAT signal or MADI input (if no ADAT port is active) used MADI input DirectOut GmbH D.O.TEC EXBOX.ADAT Manual Version 1.1 page 25 of 39

Chapter 4: Operation DirectOut Technologies userbits There is no transparency of userbits between MADI input and MADI output. However, embedded serial (RS 232) and MIDI data at the MADI input is processed unchanged to the MADI outputs. Embedded serial data: userbit of signal Channel 1 to 9 RS 232 / 422 Channel 56 MIDI Processing of serial data is possible even if MADI input and output use different sync sources. The ADAT format does not provide userbits for each channel. format detection The format (frame mode, channel mode) of the MADI output signal is defi ned by the input conditions of the used MADI input and ADAT port 8: Frame mode follows the MADI input: MAdi input 48k Frame 96k Frame MAdi output 48k Frame 96k Frame Channel mode follows the lock state of ADAT port 8: AdAt port 8 no signal present signal present (lock) MAdi output 56 ch mode 64 ch mode page 26 of 39 D.O.TEC EXBOX.ADAT Manual Version 1.1 DirectOut GmbH

DirectOut Technologies Chapter 4: Operation Routing The routing of the audio signals is fixed. The MADI input signal is output at the ADAT ports. The ADAT input signals are output at the MADI outputs. Both MADI outputs work in parallel. Channel map (1 FS): ADAT port MADI signal 1 channel 01 to 08 2 channel 09 to 16 3 channel 17 to 24 4 channel 25 to 32 5 channel 33 to 40 6 channel 41 to 48 7 channel 49 to 56 8 channel 57 to 64 The way MADI and ADAT handle audio data at higher sample rates is quite similar. At higher sample rates (2 FS / 4 FS) the number of available audio channels is reduced (32 channels / 16 channels). The higher amount of signal data is distributed across several signal channels (S/MUX). DirectOut GmbH D.O.TEC EXBOX.ADAT Manual Version 1.1 page 27 of 39

Chapter 4: Operation DirectOut Technologies Channel map (2 FS): AdAt port MAdi signal 1 channel 01 to 04 2 channel 05 to 08 3 channel 09 to 12 4 channel 13 to 16 5 channel 17 to 20 6 channel 21 to 24 7 channel 25 to 28 8 channel 29 to 32 Channel map (4 FS): AdAt port MAdi signal 1 channel 01 to 02 2 channel 03 to 04 3 channel 05 to 06 4 channel 07 to 08 5 channel 09 to 10 6 channel 11 to 12 7 channel 13 to 14 8 channel 15 to 16 To pass through audio data from the MADI input to the MADI outputs, connect the ADAT output to the ADAT input of the respective port(s). See Example 3: Inserting into MADI on page 31. page 28 of 39 D.O.TEC EXBOX.ADAT Manual Version 1.1 DirectOut GmbH

DirectOut Technologies Chapter 5: Application Examples Chapter 5: Application examples introduction This chapter describes how the EXBOX.ADAT device can be used. example 1: AdAt / MAdi frontend MADI input and output of an EXBOX.ADAT are connected to the MADI router M.1k2. Devices with ADAT signals can be integrated into a MADI environment. 8 x ADAT signal from EXBOX.ADAT bidirectional MADI signal 8 x ADAT signal to EXBOX.ADAT DirectOut GmbH D.O.TEC EXBOX.ADAT Manual Version 1.1 page 29 of 39

Chapter 5: Application Examples DirectOut Technologies example 2: backup recording The recording signal is fed to the optical MADI input of the EXBOX.ADAT. This signal is output at the coaxial MADI port - feeding a DAW. Additionally it is output at three of the eight ADAT ports - feeding a backup recording system; e.g. multitrack HD recorders. 1 x MADI signal to EXBOX.ADAT 3 x ADAT signal to HD24 1 x MADI signal to DAW The second MADI output port (optical) feeds the identical signal as the coaxial output port and could be used to connect another device. Since both MADI outputs work in parallel, the EXBOX. ADAT may be used for signal conversion between optical and coaxial MADI. page 30 of 39 D.O.TEC EXBOX.ADAT Manual Version 1.1 DirectOut GmbH

DirectOut Technologies Chapter 5: Application Examples example 3: inserting into MAdi The MADI signal from the mixing console is fed to the coaxial input of the EXBOX.ADAT. ADAT ports 1 to 7 are looped. ADAT port 8 is fed by an external ADAT signal source. Its signal is inserted into the MADI channels 57 to 64. The optical MADI output port feeds a DAW with a combined MADI signal containing channels 01 to 56 of the mixing console plus eight channels (57-64) of the external signal source. ADAT port looped 1 x ADAT signal (inserted) 1 x MADI signal to DAW 1 x MADI signal from mixing console A slight delay of three samples is introduced on each I/O. So, in this example the latency between MADI input and MADI output adds up to six samples in total. All devices must be in sync to each other. DirectOut GmbH D.O.TEC EXBOX.ADAT Manual Version 1.1 page 31 of 39

Chapter 6: Troubleshooting and Maintenance DirectOut Technologies Chapter 6: Troubleshooting and Maintenance Troubleshooting To identify a possible defect with the device please consult the following table. If the fault cannot be resolved using these instructions, please contact your local D.O.TEC representative or visit support. directout.eu. Issue Possible reason Solution Device doesn t work. Optical port does not work. No signal at the output port. No signal at the output port. No signal at the output port. Power supply is broken. Optic is dirty. Connections (input / output) are mixed up. Signal cable defective. Connectors of the signal cable are dirty. Check that the device is connected to the power supply and that the socket is working. Defective fuses must be exchanged by qualified service personal only. Use an air supply to carefully remove any dust. Never use objects for cleaning. Check the connections and change the cables if necessary. Exchange the signal cable. Use an air supply to carefully remove any dust. Never use objects for cleaning. or Exchange the signal cable. Always use protecting caps. page 32 of 39 D.O.TEC EXBOX.ADAT Manual Version 1.1 DirectOut GmbH

DirectOut Technologies Chapter 6: Troubleshooting and Maintenance issue possible reason solution MADI signal at the input is not stable. Signal source is defective or bad signal condition (Jitter > 1 ns) - e.g. due to exceeded length or bad screening attenuation of signal cable. Change the source or use appropriate cables (see Technical Data on page 34). Maintenance To clean the device, use a soft, dry cloth. To protect the surface, avoid using cleaning agents. The device should be disconnected from the power supply during the cleaning process. DirectOut GmbH D.O.TEC EXBOX.ADAT Manual Version 1.1 page 33 of 39

Technical Data DirectOut Technologies technical data dimensions Width 140 mm Height 42 mm Depth 140 mm weight 0.8 kg power consumption 5 watts, standby power < 0.5 watts (effi ciency level V) power supply 2 x Hirose socket (HR10) 9 V - 24 V DC (external) warning The connected power supply must provide a current limiting to a maximum of 2.5 A. environmental conditions Operating temperature +5 C up to +45 C Relative humidity: 10% - 80%, non-condensing page 34 of 39 D.O.TEC EXBOX.ADAT Manual Version 1.1 DirectOut GmbH

DirectOut Technologies Technical Data MADI Port - optical 1 x SC socket FDDI (input/output) ISO/IEC 9314-3 Wave length 1300 nm Multi-Mode 62.5/125 or 50/125 MADI Port - coaxial 2 x BNC socket (input / output) Impedance: 75 Ω 0.3 V up to 0.6 V (peak to peak) ADAT Ports - optical 16 x TOSLink socket (8 x input / 8 x output) Cable Specifications coaxial cable (MADI coaxial) - impedance 75 Ω, screening attenuation better than 85 db TOSLink - max. cable length 10 m DirectOut GmbH D.O.TEC EXBOX.ADAT Manual Version 1.1 page 35 of 39

Appendix A - Wiring Sketch DirectOut Technologies Appendix A - wiring sketch hirose hr10 (dc psu) 1 2 4 3 Pin Signal 1 DC + 2 DC + 3 DC - 4 DC - To ensure proper operation all pins should be connected. page 36 of 39 D.O.TEC EXBOX.ADAT Manual Version 1.1 DirectOut GmbH

DirectOut Technologies Index Index Symbols A B C Cable Specifications 35 CE 16 Channel mapping 27 Clock sources 25 Conditions of Warranty see Warranty Conformity & Certificates WEEE see WEEE Contact 17 Contents 14 Conventions 7 D Defective parts 12 Dimensions 34 DualSync 9, 25 E Environmental conditions 34 F Feature summary 10 First Aid 13 G H FS See Scaling factor DirectOut GmbH D.O.TEC EXBOX.ADAT Manual Version 1.1 page 37 of 39

Index DirectOut Technologies I Intended operation 14 J K L M MADI formats 10 N O P Power supply 10 Q R RoHS 16 S Sample rates 10 Scaling factor 21 Serial data embedded... 26 Servicing 12 Sketch Hirose... 36 S/MUX 27 T Technical data 34 Troubleshooting 32 U page 38 of 39 D.O.TEC EXBOX.ADAT Manual Version 1.1 DirectOut GmbH

DirectOut Technologies Index Updates 14 V W Warnings 7 Warranty 15 WEEE 16 X Y Z DirectOut GmbH D.O.TEC EXBOX.ADAT Manual Version 1.1 page 39 of 39