Keysight Technologies High-Power Measurements Using the E5072A ENA Series Network Analyzer. Application Note

Similar documents
Keysight Technologies Multi-Channel Audio Test using the Keysight U8903A Audio Analyzer

Keysight N9355/6 Power Limiters 0.01 to 18, 26.5 and 50 GHz High Performance Power Limiters. Technical Overview

Keysight Technologies Achieve High-Quality Compliance Test Results Using A Top-Quality Test Fixture. Application Note

Keysight Technologies High Power Ampliier Measurements Using Nonlinear Vector Network Analyzer. Application Note

Keysight Technologies ad Integrated RF Test Solution

Keysight Technologies N4974A PRBS Generator 44 Gb/s. Data Sheet

Keysight N9355/6 Power Limiters 0.01 to 18, 26.5 and 50 GHz High Performance Power Limiters. Technical Overview

Keysight Technologies Millimeter Wave Frequency Extenders From Virginia Diodes Inc. for the Keysight X-Series Signal Analyzers. Technical Overview

Keysight Technologies

Keysight Technologies Understanding and Improving Network Analyzer Dynamic Range. Application Note

Keysight Technologies Decoding Automotive Key Fob Communication based on Manchester-encoded ASK Modulation

Agilent 87075C 75 Ohm Multiport Test Sets for use with Agilent E5061A ENA-L Network Analyzers

Agilent Series Harmonic Mixers

Keysight Technologies Using Oscilloscope Segmented Memory for Serial Bus Applications. Application Note

Keysight 1GC DC GHz Packaged Biasable Integrated Diode Limited

Keysight Technologies Oscilloscope Memory Architectures Why All Acquisition Memory is Not Created Equal. Application Note

Keysight Technologies

Exceptional performance

Agilent 87405C 100 MHz to 18 GHz Preamplifier

Agilent Migration from 8712/8714 Series to ENA-L Network Analyzers

Keysight Technologies Oscilloscope Measurement Tools to Help Debug Automotive Serial Buses Faster. Application Note

Keysight Technologies Segmented Memory Acquisition for InfiniiVision Series Oscilloscopes. Data Sheet

Keysight Technologies N5998A HDMI Protocol/Audio/Video Analyzer and Generator

Keysight Technologies RS-232/UART Triggering and Hardware-Based Decode (N5457A) for InfiniiVision Oscilloscopes

Keysight Technologies E5500 Series Phase Noise Measurement Solutions

Keysight N1085A PAM-4 Measurement Application For 86100D DCA-X Series Oscilloscopes. Data Sheet

Keysight Technologies 83000A Series Microwave System Amplifiers

Keysight Technologies N8480 Series Power Sensors

Keysight Technologies Oscilloscope Display Quality Impacts Ability to View Subtle Signal Details. Application Note

Keysight Technologies ad Waveform Generation & Analysis Testbed, Reference Solution

Keysight Technologies Power Sensor Modules Optical Heads Return Loss Modules. Data Sheet

Oscilloscope Measurement Tools to Help Debug Automotive Serial Buses Faster

CAN, LIN and FlexRay Protocol Triggering and Decode for Infiniium 9000A and 9000 H-Series Oscilloscopes

Keysight FieldFox Microwave Analyzers

Keysight N4965A Multi-Channel BERT 12.5 Gb/s. Data Sheet

Keysight Technologies U3801A/02A IoT Fundamentals Applied Courseware. Data Sheet

FlexRay Physical Layer Eye-diagram Mask Testing

Agilent 86120B, 86120C, 86122B Multi-Wavelength Meters. Data Sheet

Agilent CSA Spectrum Analyzer N1996A

Electrical Sampling Modules Datasheet 80E11 80E11X1 80E10B 80E09B 80E08B 80E07B 80E04 80E03 80E03-NV

SignalCorrect Software and TCS70902 Calibration Source Option SC SignalCorrect software

Agilent N5183A MXG Microwave Signal Generator

FCPM-6000RC. Mini-Circuits P.O. Box , Brooklyn, NY (718)

Keysight Technologies x1149 Boundary Scan Analyzer. Technical Overview

Keysight E6650A EXF Wireless Test Set for Femtocell. Data Sheet

Keysight Technologies Mixed Analog and Digital Signal Debug and Analysis Using a Mixed-Signal Oscilloscope

Keysight Technologies Practices to Optimize PowerMeter/Sensor Measurement Speed and Shorten Test Times

Keysight E4887A HDMI TMDS Signal Generator Platform. Data Sheet Version 2.1

Agilent N4876A 28 Gb/s Multiplexer 2:1

Keysight Technologies N5431A XAUI Electrical Validation Application for Infiniium Oscilloscopes and Digital Signal Analyzers.

Agilent M9362A-D01-F26 PXIe Quad Downconverter

A Simple, Yet Powerful Method to Characterize Differential Interconnects

46 GBaud Multi-Format Optical Transmitter

Time-Saving Features in Economy Oscilloscopes Streamline Test

Agilent 4-Port PNA-L Microwave Network Analyzer

Agilent ESA Series Spectrum Analyzers

Agilent FieldFox RF Analyzer N9912A

Keysight Technologies DTMB (CTTB) X-Series Measurement Application N6156A & W6156A. Technical Overview

Evaluating Oscilloscope Mask Testing for Six Sigma Quality Standards

Electrical Sampling Modules

Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change.

Logic Analysis Fundamentals

JD725A Cable and Antenna Analyzer - Dual Port

Selecting the Right Oscilloscope for Protocol Analysis Applications

Agilent Understanding the Agilent 34405A DMM Operation Application Note

Agilent 87075C Multiport Test Set Product Overview

Agilent N4876A 28 Gb/s Multiplexer 2:1

Oscilloscope Display Quality Impacts Ability to View Subtle Signal Details

40 Gb/s PatternPro Programmable Pattern Generator PPG4001 Datasheet

Basic RF Amplifier Measurements using the R&S ZNB Vector Network Analyzer and SMARTerCal. Application Note

Keysight Technologies E4416A/E4417A EPM-P Series Power Meters and E-Series E9320 Peak and Average Power Sensors. Data Sheet

R&S RSC Step Attenuator Where precise signal levels count

R&S ZN-Z32/-Z33 Automatic In-line Calibration Modules Ensuring high accuracy with thermal vacuum testing and multiport measurements

Tektronix Logic Analyzer Probes P6900 Series Datasheet for DDR Memory Applications

Advanced Test Equipment Rentals ATEC (2832)

CAN/LIN Measurements (Option AMS) for Agilent s InfiniiVision Series Oscilloscopes

Agilent V3500A Handheld RF Power Meter

Troubleshooting Analog to Digital Converter Offset using a Mixed Signal Oscilloscope APPLICATION NOTE

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

R&S ZVA110 Vector Network Analyzer Specifications

USB-TG124A Tracking Generator User Manual

Keysight E4729A SystemVue Consulting Services

MILLIMETER WAVE VNA MODULE BROCHURE

Agilent 83000A Series Microwave System Amplifiers

Agilent Series Preselected Millimeter Mixers

Identifying Setup and Hold Violations with a Mixed Signal Oscilloscope APPLICATION NOTE

N5264A. New. PNA-X Measurement Receiver. Jim Puri Applications Specialist March Rev. Jan Page 1

Keysight Technologies Intrinsic Contact Noise: A Figure of Merit for Identifying High Resolution AFMs. Application Note

R&S ZN-Z85 Switch Matrix Specifications

Memory-Depth Requirements for Serial Data Analysis in a Real-Time Oscilloscope

Keysight Technologies N4917A Optical Receiver Stress Test Solution. Data Sheet Version 1.3 New: Extension to 8G Fibre Channel

R&S ZND Vector Network Analyzer Specifications

Product Brochure Version R&S RSC Step Attenuator Where precise signal levels count

40 Gb/s PatternPro Programmable Pattern Generator PPG4001 Datasheet

Analyze Frequency Response (Bode Plots) with R&S Oscilloscopes Application Note

Video Reference Timing with Tektronix Signal Generators

Keysight N9344C Handheld Spectrum Analyzer (HSA)

Agilent E5500 Series Phase Noise Measurement Solutions Product Overview

Agilent N4965A Multi-Channel BERT 12.5 Gb/s Data Sheet

The high-end network analyzers from Rohde & Schwarz now include an option for pulse profile measurements plus, the new R&S ZVA 40 covers the

Transcription:

Keysight Technologies High-Power Measurements Using the E5072A ENA Series Network Analyzer Application Note

Table of Contents Coniguration 1 Standard 2-port coniguration... 3 Coniguration 2 Measurements using a booster ampliier... 5 Coniguration 3 Direct receiver access with a booster ampliier... 6 Receiver Leveling... 8 Step-by-Step Guide for Measuring a Power Ampliier... 9 Appendix A. Power Handling Consideration... 16 Appendix B. Robust Design of the E5072A... 18 2

Introduction High-power test signal levels are often required for network analysis of antennas, power ampliiers, and components used for transmitting data in wireless communications and satellite systems. Testing these RF components with high-power signals can be a challenge as they require output power that may be beyond the measurement capability of a standard network analyzer. This application note will briely review the basic measurement fundamentals of characterizing devices with high-power signals using a network analyzer. Unique testing techniques and step-by-step test procedures using the Keysight Technologies, Inc. E5072A ENA series network analyzer will be introduced and described in detail. Coniguration 1: Standard 2-port coniguration The first configuration of a high-power measurement is shown in Figure 1. It uses a network analyzer as a standard test set and simple 2-port measurement is performed using the network analyzer s standard power level. The E5072A delivers a source power level up to +20 dbm from test ports (port 1 and port 2) in the frequency range from 300 khz to 1 GHz (SPD 1 ). The E5072A has a 65 db power sweep range (i.e. 49 to +16 dbm in 300 khz to 3 GHz) with specified leveled output power from the test ports that allows measurements of compression characteristics of active devices with a single power sweep 2, 3. The E5072A provides high output power from the test ports in a wide frequency range from 30 khz to 8.5 GHz, thus eliminating additional costs associated with extra hardware such as booster amplifiers. 1. SPD or supplemental performance data represents the value that is mostly likely to occur. Not guaranteed by the product warranty. 2. When the E5072A s source power is set to a value greater than the maximum power available, an error message Power unleveled will appear. In this case, lower the output power level to solve this problem. 3. Make sure that the power levels used during calibration do not damage the calibration kit. For Ecal modules, maximum input power and damage level are listed in the data sheet, part number 5963-3743E. Figure 1. Standard 2-port coniguration using test ports 1 and 2 3

Power level (dbm) Max leveled output power at test port 20 18 16 14 12 10 8 6 0.0E+00 5.0E+09 1.0E+10 Frequency (Hz) E5072A (SPD) E5072A (spec) E5071C (spec) Figure 2. Improved maximum output power level at E5072A s test port When testing high-power amplifiers, output power of the device under test (DUT) can exceed input compression level and/or cause maximum damage to the internal receivers of the network analyzer. A high-power level can also damage the network analyzer, resulting in costly repairs. It is necessary to reduce down time due to the repairs to lower cost of ownership. The problem with this configuration is that measurements are only performed within the output power level capability of the network analyzer. For characterizing nonlinear behavior of high-power devices, higher power levels at the DUT are required. Special care has to be taken to protect instruments by selecting appropriate attenuating components that can absorb the high power from the DUT. Refer to appendix A Power-Handling Consideration for details on the E5072A s powerhandling capability. 4

Coniguration 2: Measurements using a booster ampliier Many test and measurement applications need higher power levels than are typically available from network analyzers. For instance, high-power amplifiers often require high input levels to characterize them under conditions similar to actual operation. When you need an input level higher than the network analyzer s source can provide, preamplifiers are necessary to boost the power level prior to the DUT. An additional advantage of using an external amplifier is that you can place the amplifier physically closer to your DUT, which reduces cable losses to achieve higher power at the DUT. The typical configuration is shown in Figure 3. An optional isolator or attenuator can be added between the booster amplifier and the DUT to improve the source match. Be sure that these components can handle the output power level of the booster amplifier. When the output power of the DUT exceeds the compression level of the analyzer s ports or receivers, attenuation is needed to reduce the DUT s output power. Frequency response of a booster amplifier is removed or minimized by performing a source power calibration with a power meter/sensor connected to the E5072A. A power meter is connected via GPIB/USB interface (i.e. Keysight 82357B) and a USB power sensor is connected directly to a USB port on the E5072A. After the source power calibration is complete, the output power level of the E5072A is adjusted automatically to achieve the desired power level at the input of the DUT. Source power calibration transfers the accuracy of the power sensor to the network analyzer, and makes the power level at the DUT s input with deviation of less than 1 db. The problem with this configuration is temperature drift of a booster amplifier. Since the reference signal is measured before the booster amplifier, the error due to the drift cannot be removed. Moreover, the high reverse isolation of a booster amplifier will prevent accurate reflection measurements on port 1, thus S11 measurements cannot be performed using this configuration. Figure 3. Standard 2-port coniguration with a booster ampliier 5

Coniguration 3: Direct receiver access with a booster ampliier In order to overcome the drift effect of a booster amplifier, the E5072A provides direct access to all source and receiver paths to add external components such as highpower amplifiers, directional couplers, and/or attenuators. The block diagram of the E5072A is shown in Figure 4. It is essential that the network analyzer include direct access to the internal source and receivers so that the test configuration can be modified to handle high-power. A typical test configuration is shown in Figure 5. The internal reference and test bridges are replaced with high-power external couplers since the internal bridges of the E5072A have a damage level of +26 dbm. External components (i.e. couplers or attenuators) should be selected based on their high-power limits or frequency range specifications. The incident signal can be measured in the reference receiver (i.e. receiver R1 for port 1) of the E5072A after the booster amplifier rather than before, which cancels the effect of temperature drift of the booster amplifier at the test cables and reduces measurement uncertainty. The reflected signal from the DUT is detected at the test receiver A of port 1 for S11 (=A/R1) and the transmission signal through the DUT is detected at the test receiver B of port 2 for S21 (=B/R1). External attenuators are inserted in front of the receivers of the E5072A to protect the analyzer from high-power input damage. In order to ensure measurement stability and minimize drift, the cables connected to the attenuators should be kept as short as possible. This can extend the length of time between calibrations but can also minimize the amount of drift between calibrations. With this configuration, source power calibration is required to remove the effect of the stimulus variation and insertion loss associated with external couplers or RF cables in the source path. Unleveled source power from the E5072A or power fluctuation at the booster amplifier can distort compression measurements of active components under test. Similar to the standard 2-port configuration with test ports, all calibration techniques are available when using direct receiver access from the E5072A, and high accuracy and long-term stability of measurements are guaranteed. By using direct receiver access and external couplers and attenuators, measurement accuracy is improved as shown in figure 6. Source Solid - state Attenuator (65 db) SPDT Switch Mechanical Step Attenuator (60 db, 10 db step) R1 Bias- Tee A B Bias- Tee R2 Mechanical Step Attenuator (60 db, 10 db step) RCVR R1 IN SOURCE OUT SOURCE OUT CPLR THRU CPLR ARM RCVR A IN RCVR B IN CPLR ARM Port 1 Port 2 CPLR THRU SOURCE OUT SOURCE OUT RCVR R2 IN REF 1 REF 2 Figure 4. Block diagram of the E5072A 6

Figure 5. Coniguration using direct receiver access with a booster ampliier Standard 2-port configuration Configuration with direct receiver access Figure 6. Improved measurement accuracy with coniguration using direct receiver access 7

Receiver Leveling Some active components need to be specified with a certain power level at the input or output port. When doing high-power measurements with an external booster amplifier, temperature drift of the amplifier causes variation of the input power level to the DUT giving unexpected errors in measurement results. It is desirable to know the power levels accurately and sweep the power over a desired range. If you want to measure non-linear behavior of your devices such as 1 db compression point or AM to AM/AM to PM conversion, it is necessary to know power levels more accurately. The E5072A has a powerful function that adjusts the source power level across a frequency or power sweep using its receiver measurements. Before each measurement sweep, a variable number of background sweeps are performed to repeatedly measure power at the receiver for each stimulus point. Those power measurements are then used to adjust the source power level of the E5072A. With this receiver leveling function, you can achieve greater source power level accuracy with faster throughput compared to conventional methods using a power meter and power sensor. Figure 7. Receiver leveling with the E5072A replaces conventional power-adjustment method 8

Step-by-step guide for measuring a power ampliier This section describes necessary steps to measure a high-power amplifier (15 db gain) using the E5072A. Measurement of gain compression at 1 GHz is needed under a power sweep condition to provide 0 to +43 dbm from the DUT s output. The gain compression test requires that the DUT be driven with high-power levels beyond the E5072A s capability, thus an external booster amplifier is needed to complete the test system. This measurement process is described in the following steps: Step 1 Setup of test configuration Step 2 Setup of stimulus parameters Step 3 Power calibration Step 4 Receiver calibration and receiver leveling Step 5 Calibration Step 6 Measurement Step 1 Setup of test coniguration Since the DUT needs to be operating with high-power input (> +20 dbm), the test setup requires a booster amplifier, external couplers, and attenuators as shown in Figure 8. See appendix A Power Handling Consideration to examine the power handling capability of the E5072A s hardware and determine necessary external components. A booster amplifier is added on the source path to provide maximum +28 dbm at the DUT input. Since the internal directional bridges inside the E5072A have a damage level of +26 dbm, two external high-power couplers are used instead and are connected to the output of the booster amplifier to handle the high-power. Assuming that the couplers have 1 db insertion loss and 20 db coupling factor, additional attenuators are inserted in front of the E5072A s receivers to avoid compression. R1 A B R2 RCVR R1 IN SOURCE OUT RCVR A IN -58 to -15 dbm 25 db ATT -33 to +10 dbm Booster ampliier (Gain = 20 db) -13 to +30 dbm -33 to +10 dbm Port 1 Port 2-60 to -17 dbm High-power Coupler (IL = 1 db, CF = 20 db) 25 db ATT -35 to +8 dbm DUT -15 to +28 dbm 30 db ATT 0 to +43 dbm -30 to +13 dbm Figure 8. Test coniguration for power ampliier measurement 9

Step 2 Setup of stimulus parameters Stimulus parameters should be entered before calibration and measurement. (1) Configure stimulus parameters (IF Bandwidth, NOP, sweep type, CW Frequency etc.) [Trigger] > [Hold] [Average] > [IF Bandwidth] (1 khz) [Sweep Setup] > [Points] (101) [Sweep Setup] > [Sweep Type] > [Power Sweep] [Sweep Setup] > [Power] > [CW Freq] (1 GHz) Step 3 Power calibration Power calibration with a connected power sensor is performed to get accurate power level at the DUT s input. If the power sensor cannot handle high-power input, a high-power attenuator or a directional coupler should be inserted to protect the power sensor. The effect of this attenuation is mathematically removed by a compensation table in the E5072A firmware and the power level at the DUT s input is adjusted to the target value. (1) Connect the power meter/sensor to the E5072A. Add an attenuator or coupler if necessary 1. (Figure 9) (2) Configure setup of power sensor. (In this case, instructions are given for calibration with a USB power sensor) [System] > [Misc Setup] > [Power Meter Setup] > [Select Type] (USB) [System] > [Misc Setup] > [Power Meter Setup] > [USB] (i.e. Keysight U2000 Series with its serial number) (3) Set power offset and power level at calibration plane Power offset allows you to specify a gain or loss to account for components connected between the E5072A s test port and calibration plane. Set 18 db in power offset, as a 20 db booster amplifier and two couplers with 1 db insertion loss are inserted. After entering power offset, you can setup high-power level at the calibration plane (in this case, 15 to 28 dbm). [Calibration] > [Power Calibration] > [Power Offset] (18 db) [Stimulus] > [Start] (-15 dbm) [Stimulus] > [Stop] (28 dbm) 1. Every power sensor has a maximum power level that it is able to sense. Do not exceed the values indicated on your power sensor or listed in the data sheet. 2. If the loss is too great and the source power level can not be reached at the required level, the source level will become unleveled and an error message, Power unleveled is displayed. (4) Loss compensation If you have cable loss between the analyzer and the test port, then the source power is adjusted upward to compensate for the loss 2. Loss compensation table eliminates loss of the attenuator or coupler before a power sensor. Edit the compensation table by adding a frequency point and related loss of the attenuator and cables. (Example: Frequency = 1 GHz, Loss = 20 db) When performing frequency sweep, frequency response of the attenuation should be entered in the table. [Calibration] > [Power Calibration] > [Loss Compen] (To edit the compensation table) 10

(5) Set tolerance and maximum iteration for power calibration Measurement sweep of power calibration is continued until the power level at the calibration plane is adjusted within the accuracy tolerance. Maximum iteration allows you to set the maximum number of sweeps for power calibration until the required accuracy is obtained. [Calibration] > [Power Calibration] > [Tolerance] (0.1 db) [Calibration] > [Power Calibration] > [Max Iteration] (10) (6) Perform power calibration [Calibration] > [Power Calibration] > [Take Cal Sweep] The calibration indicator ( PC ) in blue will be displayed bottom-right of the channel display. R1 A B R2-58 to -15 dbm 25 db ATT RCVR R1 IN SOURCE OUT -33 to +10 dbm Booster ampliier (Gain = 20 db) -13 to +30 dbm Port 1-33 to +10 dbm RCVR A IN -60 to -17 dbm 25 db ATT -35 to +8 dbm Calibration Plane 20 db ATT High-power Coupler (IL = 1 db, CF = 20 db) -15 to +28 dbm Port 2 30 db ATT -35 to +8 dbm -30 to +13 dbm Power Sensor (i.e. Keysight U2004A) Figure 9. Connecting a power sensor for power calibration 11

Step 4 Receiver calibration and receiver leveling To avoid short-term temperature drift of a booster amplifier, use receiver leveling to adjust the power level at the DUT s input. Receiver calibration should be performed prior to receiver leveling. Receiver calibration mathematically removes frequency response in the receiver path, and adjusts the E5072A s readings to the same as the power level in dbm at the calibration plane. Receiver leveling is performed to adjust the E5072A s source power to obtain the target power level at the calibration plane. Leveling sweeps are performed at each stimulus data point and the deviation from the target power level is applied to the source power level until the desired target power level is achieved. Receiver calibration: (1) Select source and receiver port to be calibrated. [Calibration] > [Receiver Calibration] > [Select Receiver] (R1) [Calibration] > [Receiver Calibration] > [Source Port] (1) [Calibration] >[Receiver Calibration] > [Power Offset] (0 db) (2) Perform receiver calibration [Calibration] > [Receiver Calibration] > [Calibrate] If the R1(1) (the absolute value at receiver R1 when port 1 is selected for the source) is selected as a measurement trace, the power level in dbm at the calibration plane is displayed. When receiver calibration is completed, softkey [Correction] under [Receiver Calibration] is turned on. Receiver leveling: (1) Select a receiver to be used for receiver leveling. [Sweep Setup] > [Power] > [Receiver Leveling] > [Port 1] > [Receiver R1] (2) Set power offset for receiver leveling Power offset value for power calibration is normally used for power offset for receiver leveling. [Sweep Setup] > [Power] > [Receiver Leveling] > [Port 1] > [Power Offset] (18 db) (3) Set tolerance and maximum iteration Receiver leveling continues until the target power level at the calibration plane for each stimulus data point is adjusted within the specified tolerance value, or until the specific number of leveling sweeps has been reached. [Sweep Setup] > [Power] > [Receiver Leveling] > [Port 1] > [Tolerance] (0.1 db) [Sweep Setup] > [Power] > [Receiver Leveling] > [Port 1] > [Max Iteration] (5) (4) Turn on receiver leveling for port 1. [Sweep Setup] > [Power] > [Receiver Leveling] > [Port 1] > [Leveling] (On) 12

Step 5 Calibration In transmission measurements, enhanced response calibration improves accuracy compared to a typical response calibration. Although this calibration technique is not as accurate as a full 2-port calibration, it provides a fast measurement with a single frequency sweep. You must make sure that the power levels of the calibration measurements do not damage the calibration standards. When using an electrical calibration unit (ECal), the power levels of calibration should not exceed the compression level of the standard. Compression level and damage level is listed in the data sheet for the ECal modules, part number 5963-3743E. (1) Select calibration method [Calibration] > [Calibrate] > [Enhanced Response] > [Select Ports] > [2-1 (S21 S11)] (2) Perform reflection measurement for full 1-port calibration using connected calibration standards (Figure 10) [Calibration] > [Calibrate] > [Enhanced Response] > [Open] [Calibration] > [Calibrate] > [Enhanced Response] > [Short] [Calibration] > [Calibrate] > [Enhanced Response] > [Load] (3) Connect thru standard and perform calibration measurement (Figure 11) [Calibration] > [Calibrate] > [Enhanced Response] > [Thru] (4) Enable error correction [Calibration] > [Calibrate] > [Enhanced Response] > [Done] When calibration measurements are completed, the calibration indicator ( Cor ) in blue will be displayed at bottom-right of the channel display. 13

R1 A B R2-58 to -15 dbm 25 db ATT RCVR R1 IN SOURCE OUT -33 to +10 dbm Booster ampliier (Gain = 20 db) -13 to +30 dbm Port 1-33 to +10 dbm RCVR A IN -60 to -17 dbm 25 db ATT -35 to +8 dbm Calibration Plane High-power Coupler (IL = 1 db, CF = 20 db) - -15 to +28 dbm Open Short Load Port 2-30 to +13 dbm 30 db ATT Figure 10. Connecting calibration standards (Open/Short/Load) for full 1-port calibration R1 A B R2-58 to -15 dbm 25 db ATT RCVR R1 IN -33 to +10 dbm SOURCE OUT Booster ampliier (Gain = 20 db) -13 to +30 dbm Port 1-33 to +10 dbm RCVR A IN -60 to -17 dbm 25 db ATT -35 to +8 dbm Calibration Plane Thru High-power Coupler (IL = 1 db, CF = 20 db) -15 to - +28 dbm Port 2-45 to -2 dbm 30 db ATT Figure 11. Connecting thru standard for calibration measurement 14

Step 6 Measurement The gain compression (S21) of the amplifier under test is measured with a single trigger. [Meas] > [S21] [Trigger] > [Single] Summary This application note reviewed the basic techniques for high-power measurements using network analyzers with a configurable test set and a step-by-step measurement procedure using a power amplifier and the E5072A ENA series network analyzer. The cost-effective E5072A is an ideal solution for characterization of your devices with high-power levels. 15

Appendix A. Power Handling Consideration One of the main factors to consider in a high-power network analyzer measurement is the power handling capability of the internal components of the network analyzer. High power levels can damage the network analyzer, and it is costly to repair the internal components of the analyzer. It is important to understand how the analyzer works and the power handling capability of each component in the signal path. Each test port of the E5072A is associated with six SMA connectors and three jumper cables for direct receiver access on the front panel (Figure 12). The damage level and compression level are listed in Table 1. Be sure not to exceed these levels and add external attenuating components such as attenuators or couplers to the test system if necessary. The input power level should be at least 3 db below the damage level of the connectors on the E5072A (ideally at least 6 db lower). Figure 12. Test port jumpers on front panel Table 1. Damage level and compression level of test ports Connector RF Damage Level (Typ.) DC Damage Level (Typ.) 0.1 db Compression Level (SPD) Test port 1 & 2 +26 dbm ± 35 VDC +6 dbm (30 to 300 khz) +16 dbm (300 k to 2 GHz) +14 dbm (2 G to 6 GHz) +10 dbm (6 G to 8.5 GHz) CPLR ARM +15 dbm 0 VDC RCVR A IN, RCVR B IN +15 dbm ± 16 VDC 15 dbm (30 to 300 khz) 10 dbm (300 k to 8.5 GHz) SOURCE OUT (Port 1 & 2) +26 dbm 0 VDC CPLR THRU (Port 1 & 2) +26 dbm ± 35 VDC REF 1/ 2 SOURCE OUT +15 dbm 0 VDC RCVR R1 IN, RCVR R2 IN +15 dbm ± 16 VDC 15 dbm (30 to 300 khz) 10 dbm (300 k to 8.5 GHz) It is important to know the loss of path associated with internal components of the E5072A, in order to determine the power level applied to the individual components. The loss of internal directional bridges on the E5072A is listed in data sheet, part number 5990-8002EN. Typical coupling factor and insertion loss of internal directional bridges are shown in Figure 13 and Figure 14. 16

Figure 13. Typical coupling factor of internal directional bridges for test receivers A or B (CPLR THRU to CPLR ARM) Figure 14. Typical insertion loss of internal directional bridges (Test port (port 1 or port 2) to CPLR THRU) 17

Appendix B. Robust Design of the E5072A The E5072A have adopted a robust design for its internal architecture, both hardware and software. Protection circuits inside the instrument protect the E5072A from electronic stress thus dramatically reducing downtime and repair costs. Power trip The E5072A has implemented a useful function called power trip that monitors input signal levels at the internal receivers (R1, R2, A or B) of the E5072A. If the excessive signal levels are detected, output power from the E5072A s source is turned off automatically. This function protects the E5072A s internal circuits from the unexpected damage, especially when making high-power measurements with an external booster amplifier. Since the monitored frequency range is not limited to tuned frequency at the receivers but the whole operation frequency of the E5072A (that is 30 k to 4.5 GHz for option 245, 30 k to 8.5 GHz for option 285), this function is beneficial when measuring devices with frequency-offset mode turned on. Power limit Maximum power limit sets a maximum power level from the E5072A s source for each port of the E5072A. Once the maximum power limit is set, the power level can only be set below the defined maximum power limit. This prevents an unexpected high-power input to the DUT or the booster amplifier and potential damage of the receivers of the E5072A. [System] > [Misc Setup] > [Power Limit Setup] > [Port 1 (2)] > [Max Power] (i.e. 10 dbm) [System] > [Misc Setup] > [Power Limit Setup] > [Port 1 (2)] > [Enable] (On) User preset As a default, presetting the E5072A will preset the output power level to 0 dbm, which may result in damaging the booster amplifier of the DUT in the test system or the E5072A itself with high-power input. In this case, setup user preset to recall a pre-defined state file with the power level lower than factory preset condition. [Save/Recall] > [Save State] > [UserPres] [System] > [Misc Setup] > [Preset Setup] > [State] > [User] 18

References E5072A Configuration Guide, part number 5990-8001EN E5072A Data Sheet, part number 5990-8002EN E5072A Quick Fact Sheet, part number 5990-8003EN E5072A Technical Overview, part number 5990-8004EN 7 Reasons to update from the 8753 to the ENA, part number 5989-0206EN Network Analyzer Selection Guide, part number 5968-5260E ENA series web page: http://www.keysight.com/find/ena E5072A web page: http://www.keysight.com/find/e5072a 19

20 Keysight High-Power Measurements Using the E5072A ENA Series Network Analyzer - Application Note mykeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. www.lxistandard.org LAN extensions for Instruments puts the power of Ethernet and the Web inside your test systems. Keysight is a founding member of the LXI consortium. Three-Year Warranty www.keysight.com/find/threeyearwarranty Keysight s commitment to superior product quality and lower total cost of ownership. The only test and measurement company with three-year warranty standard on all instruments, worldwide. Keysight Assurance Plans www.keysight.com/find/assuranceplans Up to five years of protection and no budgetary surprises to ensure your instruments are operating to specification so you can rely on accurate measurements. www.keysight.com/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2008 Quality Management System Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight s measurement expertise and product breadth, combined with channel partner convenience. For more information on Keysight Technologies products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 Asia Paciic Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 0800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-07-10-14) This information is subject to change without notice. Keysight Technologies, 2011-2014 Published in USA, August 1, 2014 5990-8005EN www.keysight.com