Vitesse Plus Pre-set configurations
Vitesse Plus Lighting Control Module (LCM) The Vitesse Plus lighting control module provides control of up to 12 luminaires over 7 channels. This offers ultimate flexibility for dimming and switching groups of luminaires. The LCM has 4 RJ45 PIR inputs and SELV inputs for the connection of up to 5 centre biased retractive switches and a master on switch. Additional pluggable connections are provided for corridor hold and Emergency lighting test. Scene Control Plates The Vitesse Plus scene plate provides scene setting functions for the Vitesse Plus Lighting Control system. when used in conjunction with dimming lighting control modules and compatible dimming luminaires lighting scenes can be set for applications such as meeting rooms and classrooms. Presence detectors The Vitesse Plus range of presence detectors including ceiling flush mount (shown), long and mid-range microwave detectors and a mini PIR for integration into luminaires. All connected to the LCM using a RJ45 lead.
Contents Vitesse Plus Quick Start guide Commercial applications Presets 1 7 Corridor applications Presets 8 9 Education Graduated dimming Presets 10 17 Education Perimeter dimming Presets 18 25 Education Perimeter switching Presets 26 33 Scene Setting Commercial applications Presets 34 38 Scene Setting Education Presets 39 48 Specialised variations Presets 49 60
C H1 CH2 CH3 CH4 CH5 C H 6 CH6 CH 7 Vitesse Plus Quick Start guide 1 Connect all detectors and switches to the LCM before following this procedure. Refer to the VITP7-MB installation guide for details on how to do this. Mains power supply CH1 CH2 CH3 CH4 CH6 Emergency lighting test CH5 CH7 Master switch
Vitesse Plus Quick Start guide 2
Vitesse Plus Quick Start guide 3
Commercial applications Preset 1
Commercial applications Preset 2
Commercial applications Preset 3
Commercial applications Preset 4
Commercial applications Preset 5
Commercial applications Preset 6
Commercial applications Preset 7
Corridor applications Preset 8 The maximum number of LCMs connected together using the corridor hold connections is 20. The CSA of the cable should be 1.50mm and the length of run should not exceed 100m. The LCM that is feeding the offices is linked to the LCM in the corridor via the corridor hold connections. If any one of the offices is occupied the corridor lights will remain on. If there is natural light available in the corridor the local detector connected to the corridor LCM will switch off the corridor luminaire s. Windows IN OUT IN OUT
Corridor applications Preset 9 The maximum number of LCMs connected together using the corridor hold connections is 20. The CSA of the cable should be 1.50mm and the length of run should not exceed 100m. The LCM that is feeding the offices is linked to the LCM in the corridor via the corridor hold connections. If any one of the offices is occupied the corridor lights will remain on. If there is natural light available in the corridor the local detector connected to the corridor LCM will dim the corridor luminaire s. Windows IN OUT IN OUT
Education Graduated dimming Preset 10
Education Graduated dimming Preset 11
Education Graduated dimming Preset 12
Education Graduated dimming Preset 13
Education Graduated dimming Preset 14
Education Graduated dimming Preset 15
Education Graduated dimming Preset 16
Education Graduated dimming Preset 17
Education Perimeter dimming Preset 18
Education Perimeter dimming Preset 19
Education Perimeter dimming Preset 20
Education Perimeter dimming Preset 21
Education Perimeter dimming Preset 22
Education Perimeter dimming Preset 23
Education Perimeter dimming Preset 24
Education Perimeter dimming Preset 25
Education Perimeter switching Preset 26
Education Perimeter switching Preset 27
Education Perimeter switching Preset 28
Education Perimeter switching Preset 29
Education Perimeter switching Preset 30
Education Perimeter switching Preset 31
Education Perimeter switching Preset 32
Education Perimeter switching Preset 33
Scene Setting Commercial applications Preset 34
Scene Setting Commercial applications Preset 35
Scene Setting Commercial applications Preset 36
Scene Setting Commercial applications Preset 37
Scene Setting Commercial applications Preset 38
Scene Setting Education Preset 39
Scene Setting Education Preset 40
Scene Setting Education Preset 41
Scene Setting Education Preset 42
Scene Setting Education Preset 43
Scene Setting Education Preset 44
Scene Setting Education Preset 45
Scene Setting Education Preset 46
Reserved for future use Scene Setting Education Preset 47
Scene Setting Education Preset 48 Reserved for future use
Specialised variations Preset 49
Specialised variations Preset 50
Specialised variations Preset 51
Specialised variations Preset 52
Specialised variations Preset 53
Specialised variations Preset 54
Specialised variations Preset 55
Specialised variations Preset 56
Specialised variations Preset 57
Specialised variations Preset 58
Specialised variations Preset 59
Specialised variations Preset 60
CP Electronics Ltd. Brent Crescent London NW10 7XR United Kingdom t. +44 (0)333 900 0671 f. +44(0)333 900 0674 info@cpelectronics.co.uk connect with us www.cpelectronics.co.uk for product information www. cpelectronicscorporate.com for company information PM-VITP-CONFIGS