Sample Connections: Viessmann Semaphore Signals with one and two drive units

Similar documents
To be a Digital-Professional! Digital switching of Viessmann Semaphore Signals with one and two drive units (Märklin 3-rail conductor)

To be a Digital-Professional! Digital driving and switching of dual-coil drives with RedBox and 2-rails conductor

Control of the Märklin Turntable 7286 with the Turntable-Decoder TT-DEC via the turntable symbol at the track control of the Central Station 3 (plus)

Operation Instruction TurnTable-Decoder TT-DEC

Be a Digital Professional! Set-Up of TrainController 8.0 Gold for the TurnTable- Decoder TT-DEC-R with Roco H0 Turntable 42615

Pricelist No. 1/2017 (Validity from 1. February 2017)

Operation Instruction TurnTable-Decoder TT-DEC

To be a Digital-Professional! American Color Light signals digital controlled by the Light-Signal Decoder LS-DEC-USA

Basic Manual Light-DEC

SHUTTLE WITH INFRA-RED DETECTION SAS2-IR

LED Interior Lighting Sets Instruction Manual (380mm)

Turnout Decoder TD Maxi. User Manual - version 0.1.6

Tailgate module BEXPRO PRINS VSI

Azatrax Model Railroad Track Signal Control - Single Track

M150SP USER S AND INSTALLER S MANUAL. v2.0 REV. 03/2017

Atlas Drop In Decoder

RF Wireless Receiver (Model S4PU-DC-ANT3)

SPECIFICATION NO NOTE

MYSTERIOUS BEHAVIOUR OF VIESSMANN 5211 ACCESSORY DECODERS USED WITH ECoS 2 A journey of discovery by Walter Dorman October 2017

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

Dear Railway Modeller,

Understanding VFD. Variable Frequency Drive. nfi. nfi

DR4018 DIGISWITCH HANDLEIDING / MANUAL BEDIENUNGSANLEITUNG / MANUEL. DR4018 DIGISWITCH (v1.2) V1.2 ( )

FUTURE-CENTRAL-CONTROL (FCC) Operating instructions

SPECIFICATION NO Model 207 Automatic GTAW Welding System

LF101XF Six Function DCC Function Only Decoder Art. No February 2007

AC 2-wire Inductive Sensors

21 Channel Light Show PWM LED Controller with Remote Control

SECU-16. Specifications Power: Input Voltage 9-12V DC or AC Input Current Max 200mA. 8 2-wire inputs, Analog (0 5VDC) or Supervised

Introduction to Layout Control with JMRI/PanelPro. Create a Detailed CTC Machine Model with JMRI/PanelPro

H2633IP-1 RELAY CARD K2633

STX Stairs lighting controller.

Art M Digital codelock module

LD-G-30 LD-G-31 LD-G-32 LD-G-33 LD-G-34 LD-W-32 LD-W-33

User Manual. LokSound2. Version 1.0 January 2002

HS-509 VIBRATION TRIP MODULE

File E Project December 11, 2013 REPORT DRIVERS FOR LIGHT-EMITTING DIODES ARRAYS MODULES AND CONTROLLERS

CL-DMX-2900 Decoder Specification

PRODUCT MANUAL. Chroma Flow PRO RGB LED Controller. and Receiver. Product Description. Main Functions: This manual reviews: Receiver.

ECoSDetector Extension

USER GUIDE. DM Engineering Multi Station Relay Adapter (MSRA and MSRA-RM) Version DM Engineering

FD400Multi Function Decoder. User Manual. 04/2013

Light-It Decoder p/n Lighting decoder w/built-in white LED

User Manual. LokSoundXL. Version 2.1 May 2002

Information LG100 Brake Module

Ordering details. Approval. Classification

FOREST SHUTTLE S / L / M RECEIVER

N3ZI Digital Dial Manual For kit with Backlit LCD Rev 4.00 Jan 2013 PCB

RGB LED Controller and Dimmer Pro Plus RF Remote 3-Channels, 12 or 24 VDC Part No. RGB-3-Dimmer-Pro

Projector Lift. User Guide INSTALLATION OPERATION SETUP PROGRAM IR REMOTE FACTORY RESET

Technical Description Track-Control

Visit the Abrams Railroad Empire at

AVS50 USER GUIDE. 2.4GHz Audio/Video Sender System - AVS50

8 Ports. 16 Ports. ED5219LGT Series. CATV Single Channel EDFA 1310nm Forward Optical Transmitter

E R A I GATE OPENERS DEPARTMENT

90 Series - Sockets and accessories for 60 series relays

REMOTE DISPLAY WIRELESS DECODER MK II

N3ZI Digital Dial Manual For kit with Serial LCD Rev 3.04 Aug 2012

Contents: 1 LANsmart Pro Main Unit 4 Remote Unit: ID1, ID2, ID3, ID4

CET DOUBLE COUNTER WITH TWO THRESHOLDS LBM62CD. Type: TECHNICAL FEATURES

XT-17M-B relay - Delay-off, 1 C/O, 16 A

Master Time Clock MTC Users Manual

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

ECoS - Just Play ESU LLC

Chapter 9 MSI Logic Circuits

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

SLICE6 3-CHANNEL SENSOR CONNECTOR ASSEMBLY DOCUMENT

Automatic Transfer Switch Control PLC Operator s Manual

INSTRUCTIONS FOR USE Pro-Ject Tuner Box S2

LokPilot V4.0. Instruction Manual. LokPilot V4.0. LokPilot V4.0 DCC LokPilot micro V4.0 LokPilot micro V4.0 DCC

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

Documentation VFD clock 8 a clock

ESU LokSound Select Direct Micro "Keep-Alive"

Colour Control48 Order Code: Control48

Datasheet - SRB301LC 24VAC/DC

DCC Install Primer. Victor Pinamonti

High intensity led illuminator ILED42A FEATURES: DESCRIPTION: ELECTRICAL CHARACTERISTICS:

Selection guide siemens.com/sirius-modular-system

VU Meter Buffer DIY Kit

Solenoid Valves. Inline Valves IV. Nominal diameter 3 mm. Suitability for Industry-Specific Applications Schmalz - Applications.

Mal-2 assembly guide v1.0

INSTRUCTIONS FOR USE Pro-Ject Phono Box DS2 USB

Manual for the NMRA compatible DCCaccessory

POINTS POSITION INDICATOR PPI4

Complete Train Control. Run Your Trains, Not Your Track!

Pluggable interface relays CR-M Miniature relays

Signet 2250 Hydrostatic Level Sensor

Total solder points: 123 Difficulty level: beginner 1. advanced AUDIO ANALYZER K8098. audio gea Give your. . high-tech ILLUSTRATED ASSEMBLY MANUAL

Repairing Mitsubishi WS Blinking green light fuse replacement

Type MG-6 Auxiliary Relay Class 1E

MOD028 GLOCKENSPIEL TECHNO-MUSIC-OLOGY

One channel multiswitch EMS-16-R EMS-16-G EMS-24-G

Digital Ratio Controller

Series CT7N Bimetallic Overload Relays

Kicker SUM8 OEM integration solution

RENFE TAF / CP FOGUETE References: & 47023

Manual for the NMRA compatible DCC- DIY accessory decoder. WDecN-90

N14IP Decoder. $29.95 Decoder version 3.5. Direct plug in for Con Cor N-Scale PA1, and other locomotives with DCC 8 pin socket

INSTALLATION AND OPERATION MANUAL

MODULAR RAILROAD SPECIFICATIONS FAQ

Transcription:

Sample Connections: Viessmann Semaphore Signals with one and two drive units 1. Digital Operation of Viessmann Semaphore Signals with one Drive Unit (e.g. 4400, 4401, 4405, 4500, 4501, 4505, 4900 and 4901) Viessmann Semaphore Signals with one drive unit can be operated either via the LDT-Turnout Decoder S-DEC-4 or the Switch Decoder SA-DEC-4. One signal can be digital controlled by each output. The following sample connections will show the function. KL2 S-DEC-4 Rev. 2.3 + ~ ~ - 12... 18V~ 4-fach Magnetartikeldecoder 15... 24V= 4-fold turnout decoder G R R 3 G R 4 G Magnetartikel-Decoder S-DEC-4-MM Für 4 Doppelspulenantriebe für Märklin-Motorola Digitalsysteme. Schaltstrom: 1 Ampere pro R R G Semaphore Signal with one drive unit connected to the Turnout Decoder S-DEC-4-MM or S-DEC-4-DC Address Phone 1

R Schaltdecoder SA-DEC-4-MM 4-fach Schaltdecoder 4-fold Switch Decoder 12...18V~ SA-DEC-4 15... 24V= Rev. 2.4 3 4 Mit 4 bistabilen Relais für Märklin-Motorola Digitalsysteme. Schaltstrom: 4 Ampere pro Semaphore Signal with one drive unit connected to the Switch Decoder SA-DEC-4-MM or SA-DEC-4-DC Address Phone 2

2. Digital Operation of Viessmann Semaphore Signals with two drive units (e.g. 4402, 4502 and 4902) As semaphore signals with two wings require eventually only one control command for a new signal aspect with both wings there is a control module implemented within the connection of the signal with two drive units to assure the requi intersection. For the selection of the control system Viessmann has themselves orientated to positive control impulses as used by the Märklin system. LDT Decoder produces negative control impulses. For controlling turnouts or signals with solenoid drives or uncoupling devices the polarity of the control impulses are not important. 2.1. For the application of decoder with negative switch impulses Viessmann offers a suitable control module by a respective request. Control module Steuermodul negative Schaltimpulse negative switch impulses KL2 S-DEC-4 Rev. 2.3 + ~ ~ - 12... 18V~ 4-fach Magnetartikeldecoder 15... 24V= 4-fold turnout decoder G R 3 G R 4 G Magnetartikel-Decoder S-DEC-4-MM Für 4 Doppelspulenantriebe für Märklin-Motorola Digitalsysteme. Schaltstrom: 1 Ampere pro R R G Semaphore Signal with two drive units on the Turnout Decoder S-DEC-4-MM or S-DEC-4-DC with control module for negative switch impulses (supplied by Viessmann by respective request or realized by turning the diodes at the control module as explained under 2.2). Address Phone 3

2.2. Even with low experience in soldering electronic components you can easily rebuild a module for negative switch impulses out of a control module with positive switch impulses. You have just to unsolder all 4 diodes of the control module, turn them by 180 degree and re-solder them at the old position. The connection plan at the previous page shows how to connect the LDT-Decoder S-DEC-4-MM or the S-DEC-4-DC to a two wings semaphore signal. 2.3. The next sample connection shows the possible application of a semaphore signal with two drive units and a control module for positive switch impulses (as supplied ex-factory by Viessmann together with the signal) with LDT-Decoder. It is possible to use our switch decoder SA-DEC-4-MM or SA-DEC-4-DC for this application. The wiring corresponds to the sample connection within the Viessmann operation instruction for the signal. The switch decoder includes 4 potential-free switch contacts for digital control. Control module Steuermodul positive Schaltimpulse positive switch impulses Schaltdecoder SA-DEC-4-MM 4-fach Schaltdecoder 4-fold Switch Decoder 12...18V~ SA-DEC-4 15... 24V= Rev. 2.4 3 4 Mit 4 bistabilen Relais für Märklin-Motorola Digitalsysteme. Schaltstrom: 4 Ampere pro Semaphore Signal on the SA-DEC-4-MM or SA-DEC-4-DC with control module for positive switch impulses. Address Phone 4

To be able to a digital switching of a three-aspect signal are two decoder addresses respectively outputs requi. Via the address 1 will be the signal switched to Stop and Proceed. With the address 2 will be the semaphore signal switched to Slow approach. The signal will be switched as follows: "Stop" "Proceed" "Slow approach" Output 1 ON Output 1 OFF; Output 2 ON Output 1 OFF; Output 2 OFF If you want an automatic switching of the signal (with MEMORY or with a computer software), is this possibility recommended. But if you intend to switch the signal via a KEYBOARD or a remote control it is recommended to use the first solution by using the Turnout Decoder S-DEC-4 because then it will be requi to activate just one key to switch the signal. Subject to technical changes and errors. 03/2015 by LDT Address Phone 5