Matt Dann Cultural Centre Matt Dann Theatre Technical Specifications 13/07/09 Technical Manager: Brad Holder Phone number: 08 9158 9369 Mobile Number: 0447 632 936 Fax number: 08 9172 2472 Email address: mdtech@porthedland.wa.gov.au Venue: Phone number: 08 9158 9369 Fax number: 08 9172 2472 Website: www.mattdann.porthedland.wa.gov.au
STAGE Brief Stage Description: The stage is a three sided thrust stage located in the corner of the auditorium. The stage is an Air-Thrust system comprising two layers of 12mm thick 5 ply with a painted parquetry top. This gives the floor a sprung feeling with an even flat surface. Stage Dimensions: Proscenium See plan for details Width 9.8m Height Overhead obstructions There are air-conditioning above light grid. Auditorium: Auditorium flanks the stage on three sides. The three seating banks are a fixed seating system with a total of four aisles. Seating capacity with additional Orchestra lift/pit seating installed 302 Seating capacity without Orchestra lift/pit seating installed Drapery: *Type Material Colour Width Height Quantity Wool 50% Legs gathered Black 1000mm 5200mm 2 Tabs / Black Wool Smother 10000mm 5200mm 2 Projection White screen 9000mm 4000mm 1 Access Equipment: Elevated Work Platform Theatre hires a boom lift for rigging when required. Ladders Aluminium Extension ladder 3200mm to 5400mm Fibre glass A frame ladder 3500mm
Stage Traps: There are 3 x Stage traps each with 1 x XLR and 2 x 240v. They are at down stage centre and centre on the prompt and opposite prompt sides. Safety Curtain: Safety Curtain installed No Loading Dock: Access The loading dock is situated at the far end of the main car park it has good access and plenty of room to turn around. Trucks reverse along a purpose built drive that is lockable once the truck is in for security. Open doors before reversing into dock drive. Loading Dock Height Door Dimensions 200mm 2900mm High 2400mm Wide LIGHTING Positions: The theatre has a fixed grid in front of and above the stage. Currently there are council restrictions in place regarding access to the lighting grid. Please check with the theatre technician. Stage LX Bars Stage bars are fixed in position. Control: Lighting desk Jands Event 48 Control channels 48 Signal output Signal distribution Remote riggers available onstage DMX No Dimmer Racks: Total Dimmers 48 Dimmer Locations Bio Box 2.4Kw Dimmer Racks Total dimmers @ 2.4kw per dimmer 48 3 x Jands Roadpack 1 x Jands HP12 House Lights: Independant control the Lx desk Control positions Fade time adjustable and No 1 channel independent 2 channels through Only in Bio box
Stage Luminare: Profiles Make Model Angle Detail / Accessories Selecon Pacific 24/40 3 x Gobo Holders 650W 8 Selecon Zoom 16/32 1000w 4 Selecon Zoom 16/32 650w 6 Selecon Zoom 24/40 650w 6 Prolite Zoom Profiles 16/32 1200w 6 Watt Total Fresnel s Make Model Detail / Accessories Watt Total Prolite Selecon All have barndoors All have barndoors 1200w 10 650w 8 Par Cans Make Model Angle Detail / Watt Total Accessories Par64 MFL 120V 1000w 28 Par56 MFL 240v 300w 6 Wash Make Model Detail / Accessories Watt Total CCT Minuette 1 500w 4 Followspots: Make Model Angle Detail / Accessories Selecon ZS 200 8-16 6 colour magazine Watt Total 1200w 1 Power: 3 Phase Outlets 4 x 32Amp Wilco 5 pin three phase outlet in control room Cabling: 240v Extension Cable
3 phase Extensions 1 x 20m 5 pin three phase extension AUDIO Control Positions: Control Room Bio box at rear of theatre, can be relocated to top of aisle or back row of seating Auditorium Centre row I Total seat allocation 6 seats Control & Amplification: Primary Mixer Yamaha O2R Digital console 24 channels 8 mic preamps 8 line channels 4 stereo channels 8 auxilary sends 8 channels phantom power Secondary Mixer Allen & Heath GL2200 24 Channels 2 stereo inputs 4 sub groups 6 auxiliary sends All 24 channels are phantom power Amplifiers 4 x Yamaha P4500 2 channel 500w@8 ohms 1 x Yamaha PC2002 2channel 300w@8 ohms Quest QA3000 2 channel 700w @ 8 ohms EQ 3 x Behringer Ultra Graph GEQ 3102 FX 1 x Behringer Virtualiser Pro DSP2024P Compression / Limiter / Gates DBX160A Compressor Mono Behringer 2 Composer T1952 Stereo Speakers: FOH Speakers 2 x EVSX300 Wall mounted FOH 2 x Yamaha SW215IV subs Floor FOH Foldback 2 x12 Yamaha SM12H series 2 speakers 2x15 Yamaha SM15H series 2 2 x Yamaha 12 S12ME
Playback: Item Make Model Detail Total Dual CD Player Denon DN1200 Dual 1 CD/Minidisk Sony MXD-D4 CD/Mini disk 1 Mini Disk Sony MDS-PC1 Mini disk player 1 Microphones: Make Model Detail / Accessories Use Total Shure SM58 Wireless Vocal 3 Shure SM58 Wired Vocal 4 Shure SM57 Wired Instrument 4 Shure PGDMK6 Drum mic kit Instrument 1 Shure PDMDK4 Drum mic kit Instrument 1 Accessories: Item Model Detail / Accessories Total Microphone Stands Tripod base Boom arm 4 Tripod base Boom Arm 3 Tripod base Straight arm 2 Instrument mic stands 3 Line Patching: Location Quantity Numbering Detail 4 1-8 4 sends 3 SL, C, SR 3 send Cabling: Audio Cable Theatre has a stock of assorted microphone cables Multicore 1 x 40m 14 send by 6 returns
BACKSTAGE Communications: Stage Managers Desk Talkback Master Unit Telex BTR300 in Bio Box Total sub stations 4 x wireless belt pack Telex TR300 Total headsets 5 Paging / Show relay Available to dressing room upon request Stage Monitor Available to dressing room upon requet Q Light System In house Q light system available NO Dressing Rooms: Dressing Room Capacity Toilets Shower Details Dressing room 14 2 2 Toilet and showers in separate room Laundry / Wardrobe: Washing Machines Dryers Drying rooms Iron / ironing board 1 Clothes racks Greenroom: Tea / Coffee facilities Fridge / freezer Microwave Running water
Stage Door: Access Stage door is located beside loading dock at rear of theatre. No access unless prior arrangement is made with venue technical staff. VENUE: Venue Contacts: Venue Address Hamilton Rd South Hedland Venue Postal Address PO Box 41 Port Hedland WA 6722