Reducing CCD Imaging Data

Similar documents
Data Reduction Procedures. Python

GMOS CCD Upgrade Options S. Kleinman, J. Jensen 26Sep08

Removing the Pattern Noise from all STIS Side-2 CCD data

Python Quick-Look Utilities for Ground WFC3 Images

Results of the June 2000 NICMOS+NCS EMI Test

Delivery test of the ALFOSC camera with E2V CCD Ser. no

Reducing GMOS Spectroscopic data

PACS. Dark Current of Ge:Ga detectors from FM-ILT. J. Schreiber 1, U. Klaas 1, H. Dannerbauer 1, M. Nielbock 1, J. Bouwman 1.

Bias, Auto-Bias And getting the most from Your Trifid Camera.

Introduction. Edge Enhancement (SEE( Advantages of Scalable SEE) Lijun Yin. Scalable Enhancement and Optimization. Case Study:

Reduction of Device Damage During Dry Etching of Advanced MMIC Devices Using Optical Emission Spectroscopy

Mosaic 1.1 Progress Report April, 2010

111 Highland Drive Putnam, CT USA PHONE (860) FAX (860) SM32Pro SDK

CCD Element Linear Image Sensor CCD Element Line Scan Image Sensor

GG450 4/12/2010. Today s material comes from p in the text book. Please read and understand all of this material!

A Real Time Infrared Imaging System Based on DSP & FPGA

Financial disclosure statement. Fluoroscopic Equipment Design: What s s Different with Flat Panel? Concept of flat panel imager

Confocal Application Notes Vol. 2 May 2004

SPATIAL LIGHT MODULATORS

Smart Coding Technology

Cycle-7 MAMA Pulse height distribution stability: Fold Analysis Measurement

Internal monitoring of ACS charge transfer efficiency

Readout techniques for drift and low frequency noise rejection in infrared arrays

FPA (Focal Plane Array) Characterization set up (CamIRa) Standard Operating Procedure

Solid State Photon-Counters

Overview of All Pixel Circuits for Active Matrix Organic Light Emitting Diode (AMOLED)

From light to color: how design choices make the difference

Normalization Methods for Two-Color Microarray Data

FIES Automatic Data Reduction Software version 1.0. User Manual. Eric Stempels

ADVANCE INFORMATION TC PIXEL CCD IMAGE SENSOR. description

Critical Benefits of Cooled DFB Lasers for RF over Fiber Optics Transmission Provided by OPTICAL ZONU CORPORATION

Measuring Small. The technique of measuring very small Lateral Tape Motion (LTM) Gary Collins, P.E.

WFC3 TV2 Testing: Calibration Subsystem Performance

Analysis of WFS Measurements from first half of 2004

Data flow architecture for high-speed optical processors

Comparison of SONY ILX511B CCD and Hamamatsu S10420 BT-CCD for VIS Spectroscopy

Spatial Light Modulators XY Series

Standard Operating Procedure of nanoir2-s

Development of Simple-Matrix LCD Module for Motion Picture

Understanding Compression Technologies for HD and Megapixel Surveillance

Video Projector. Operating Instructions VPL-HW55ES (1)

ST10XME Power Extension Cable Test

CCD 143A 2048-Element High Speed Linear Image Sensor

HIgh speed Photo-POlarimeter (HIPPO) User's manual Version November 2008 Stephen Potter

Optimizing Displays for Digital Dailies

Sodern recent development in the design and verification of the passive polarization scramblers for space applications

THE DIGITAL FLAT-PANEL X-RAY DETECTORS

TechNote: MuraTool CA: 1 2/9/00. Figure 1: High contrast fringe ring mura on a microdisplay

Application Note AN-LD09 Rev. B Troubleshooting Low Noise Systems. April, 2015 Page 1 NOISE MEASUREMENT SYSTEM BASELINES INTRODUCTION

OPERATING GUIDE. M-Vision Cine 3D series. High Brightness Digital Video Projector 16:9 widescreen display. Rev A August A

Measurement of Microdisplays at NPL

LaserPXIe Series. Tunable Laser Source PRELIMINARY SPEC SHEET

Company Software Manual version Issued Date Sony Corporation Projector Calibration Pro Version 0.04 Mar 3rd, 2017

Release Notes for LAS AF version 1.8.0

843-R 843-R LASER POWER METER USER MANUAL. NEWPORT CORPORATION

Review Report of The SACLA Detector Meeting

Mastering Phase Noise Measurements (Part 3)

An ASIC for Delta Sigma Digitization of Technical CCD Video

Cisco Video Surveillance 6400 IP Camera

T sors, such that when the bias of a flip-flop circuit is

Murdoch redux. Colorimetry as Linear Algebra. Math of additive mixing. Approaching color mathematically. RGB colors add as vectors

APPLICATION NOTE. Fiber Alignment Now Achievable with Commercial Software

Threshold Tuning of the ATLAS Pixel Detector

BitWise (V2.1 and later) includes features for determining AP240 settings and measuring the Single Ion Area.

Techniques for Extending Real-Time Oscilloscope Bandwidth

DISPLAY WEEK 2015 REVIEW AND METROLOGY ISSUE

OPTICAL POWER METER WITH SMART DETECTOR HEAD

BTV Tuesday 21 November 2006

AWAIC: A WISE Astronomical Image Co-adder (and HiRes er!)

Scalable self-aligned active matrix IGZO TFT backplane technology and its use in flexible semi-transparent image sensors. Albert van Breemen

An Introduction to TrueSource

Maintenance/ Discontinued

Optimization and Deployment of the e2v L3-Vision CCD220 Mark Downing 1, Javier Reyes1, Leander Mehrgan1, Jorge Romero 2,

Illuminating the home theater experience.

The hybrid photon detectors for the LHCb-RICH counters

Testing and Characterization of the MPA Pixel Readout ASIC for the Upgrade of the CMS Outer Tracker at the High Luminosity LHC

Cisco Video Surveillance 6050 IP Camera Data Sheet

The Lecture Contains: Frequency Response of the Human Visual System: Temporal Vision: Consequences of persistence of vision: Objectives_template

Superior Digital Video Images through Multi-Dimensional Color Tables

Bringing Better Pixels to UHD with Quantum Dots

Abstract. Keywords INTRODUCTION. Electron beam has been increasingly used for defect inspection in IC chip

A TARGET-based camera for CTA

HITACHI. Instruction Manual VL-21A

Durham Magneto Optics Ltd. NanoMOKE 3 Wafer Mapper. Specifications

Signal to noise the key to increased marine seismic bandwidth

Compact multichannel MEMS based spectrometer for FBG sensing

Instrument Status Review. GSC Meeting October 2009

APPLICATIONS OF DIGITAL IMAGE ENHANCEMENT TECHNIQUES FOR IMPROVED

J R Sky, Inc. Cross-Modulation Distortion Analyzer

Scintillation Tile Hodoscope for the PANDA Barrel Time-Of-Flight Detector

Leica TCS CARS. Live Molecular Profiling Technical Documentation. Living up to Life

Other funding sources. Amount requested/awarded: $200,000 This is matching funding per the CASC SCRI project

Selected Problems of Display and Projection Color Measurement

Maintenance/ Discontinued

Smart Lighting Demos

Lecture 2 Video Formation and Representation

1ms Column Parallel Vision System and It's Application of High Speed Target Tracking

Advanced Techniques for Spurious Measurements with R&S FSW-K50 White Paper

Uncooled amorphous silicon ¼ VGA IRFPA with 25 µm pixel-pitch for High End applications

Light Emitting Diodes

Transcription:

Reducing CCD Imaging Data

Science and Calibration Data Exactly what you need will depend on the data set, but all the images generally fall into two categories. Science Exposures: Self-explanatory -- this is the data you care about Calibration Exposures: All the non-science images that must be taken for use in reducing your data. Types of calibration that are typical for optical imaging include: Dark and Bias Frames Flatfields (Dome, Twilight, Sky) Off-source sky images for sky subtraction (only for large sources) Standard Stars (for photometric calibration) Both science and calibration data can come as individual images or mosaics for multiple detector instruments. For mosaics you need to do everything described separately for each detector.

Calibration Images An observed CCD image includes signals from three sources: 1. Photons imaged onto CCD by telescope! Sources: Astronomical objects and sky! Generated by photoelectric effect 2. Dark current 3. Bias! Source: thermal electrons collected in each pixel during the exposure! A signal added to each pixel during readout Must subtract off dark current and bias. Courtesy: John Oliver

Calibration: Dark Frames Dark Frames What: Exposures taken with the shutter closed (hence dark )! Darks should have the same exposure time as your science images.! Darks should also be taken at the same temperature as your science images (why?).! You want to take multiple dark images and (median or average) combine them.! Reduces the noise! Eliminates spurious pixels in individual frames! Combined image typically called the master dark. Purpose: Remove the dark current from thermally excited electrons. Application: The master dark frame is subtracted from the science image. This dark frame will include the thermal noise from the bias, so you do not need a separate bias frame if you take darks. For this reason, you will sometimes hear people use the terms tarks and biases interchangeably.

Calibration: Bias Frames Bias Frames What: Zero second dark exposures! You want to take multiple bias images and (median or average) combine them.! Reduces the noise! Eliminates spurious pixels in individual frames! Combined image typically called the master bias. Purpose: Remove the bias signal! The bias is an offset level introduced when the detector is read out.! Even if the output from the CCD were 0 electrons, there would still be a bias signal that varies from pixel to pixel in a repeatable fashion.! This is an additive offset. Application: The master bias frame is subtracted from the science image. Relevant IRAF Tasks: ccdproc, imcombine, imarith

Calibration: Overscan Regions CCD Overscan Regions Overscan Regions: Many CCD images now include what are called overscan regions. Overscan regions are rows and columns along the image edge that are not exposed to light. These regions essentially act as darks that can be subtracted directly from the image. Typically you will have both overscan rows and overscan columns. Overscan regions can be used alone or in conjunction with dark or bias frames. If used with dark (bias) frames, then the dark (bias) should be subtracted from the overscan region as well as the rest of the image. Advantages:! Overscan taken at same time as data, so reflects actual electronic noise and any time variability Disadvantages:! Overscan regions do not contain full 2D information contained in a dark or bias.

Calibration: Overscan Regions Overscan

Calibration: Overscan Regions CCD Overscan Regions Application: 1. For an set of overscan columns (rows) compute the average or median across the columns (rows). 2. Normally you want to smooth across a few columns (rows) to make the overscan less noisy. 3. Subtract this average/median value from all the other pixels in the image. 4. If you have both overscan colums and rows, subtract them sequentially. When you do the first subtraction -- say subtraction of the overscan columns, you will want to subtract this value from the overscan region as well as the rest of the image. Relevant IRAF tasks: colbias linebias Colbias is used in one of the IRAF tutorials that you are working through in lab.

Calibration: Dark,Bias,Overscan Practical Notes:! For most of the optical data sets that you download, there will not be separate dark frames.! You will likely either have a bias frame or just overscan regions.! It is a good idea to look at the overscan region and mask out any regions that sharply spike in brightness. These are generally spurious and will result in streaks in your images if you include them. Using the median rather than average also helps minimize the impact of these pixels

Calibration: Flatfields Flatfields What: Exposures of a uniformly illuminated source! Types of flatfields: Dome, Twilight, Sky! You want to use multiple flatfield images and median combine them.! Reduces the noise and eliminates spurious pixels in individual frames.! Eliminates objects for twilight and sky flats! Must normalize all images to same mean value before combining! Combined image typically called the master flat.! Normalized to have a mean value of 1.! Taken in each filter! For dome and twilight flats, you want to have as many counts per pixel as possible to reduce noise, but not so bright as to saturate or have concerns about nonlinearity. Purpose: Correct for pixel-to-pixel sensitivity variations! Each pixel has a different response! Quantum efficiency variations, dust on the optics, vignetting,...! If illuminate all pixels with the same brightness, then you can measure and correct for these variations Application: Divide the science frame by the master flat. Relevant IRAF tasks: imcombine, flatcombine, ccdproc, imarith

Flatfields Dust Donut Bad Pixel Fringing**

Calibration: Flatfields Flatfields Dome Flats Images of a uniformly illuminated white screen inside the dome. Twilight Flats Images taken at twilight, when the sky is much brighter than astronomical sources. Effectively using the sky as your uniformly illuminated screen. Sky Flats Median combination of many science exposures during the night, again using the sky as your uniformly illuminated screen....each has advantages and disadvantages...what you use will be determined by what s available in the archive...

Calibration: Standard Stars Standard Stars What: Images of stars with well-known magnitudes (and colors)! Only relevant when the weather is photometric! Each standard star should be observed multiple times during the night at different airmasses Purpose: To enable photometry! Need an object with known magnitude to determine the magnitudes of other sources that are your science targets Application for Projects: For VLT data sets you will be able to obtain the photometric zeropoint directly from the archive without calibration. For the other telescopes rough zeropoints must be computed using standards from the same night. Landolt 1992, AJ, 104, 340

Calibration: Sky Subtraction Off-Source Sky Subtraction Images What: Images of blank parts of the sky near your target. Purpose:! If the target you are observing is a nebula or other very extended source, this is the only way to cleanly remove the sky. Application for Projects: You do not need to worry about off-source sky images

Calibration: Sky Subtraction Off-Source Sky Subtraction Images What: Images of blank parts of the sky near your target. Purpose:! If the target you are observing is a nebula or other very extended source, this is the only way to cleanly remove the sky. Application for Projects: You do not need to worry about off-source sky images Landolt 1992, AJ, 104, 340

Reductions: Cosmic Rays Cosmic Ray Removal What: Elimination of cosmic ray events from images. Purpose:! If not removed, cosmic rays compromise photometry and yield spurious detections. Application for Projects: Cosmic rays can be removed when stacking images. Why would HST have lots of cosmic rays? HST Raw Image Stacked ACS image after cosmic ray removal

Steps In Reducing Your Data Outline (every one of these can be discussed in great detail): 1. Download all science and calibration images 2. Average or median combine your dark or bias frames and subtract this median from the rest of your images. 3. Subtract the overscan regions (if applicable) from all your images. 4. Create a combined flatfield and divide the images by the flatfield. 5. Use the flatfield to create a bad pixel mask, and mask the bad pixels in all images. 6. Fringe removal: for red bands (e.g i,z), where fringing is an issue, you may need to construct a fringe frame and remove the fringes. 7. Depending on the wavelength and science, possibly perform a sky subtraction. 8. Determine the offsets between all the images of a given field and align the images 9. Stack the images to produce a single, deep frame for each filter. During the stacking you will want to use a clipping algorithm to remove cosmic rays.

Optimal Timeline Below is a suggested timeline for completing different portions of the independent projects. The pace at which you proceed is left to your discretion, but you are encouraged to start early in case of setbacks. Note that, while 7 lab periods are dedicated to the projects, you will be expected to also work on the projects outside of lab. February Lab periods on Feb 13, 20 (note that the idl tutorial has been cancelled)! Finish downloading data! Perform bias subtraction and overscan subtraction! Create and apply flatfields! Make and apply bad pixel masks March Lab period on March 6! Perform fringe correction or sky subtraction if necessary! Align and combine images April Lab periods on April 3,10,17,24! Photometry! Analysis (CMD, color-color diagrams)! Final Report

Filters: A Review There are a host of different filters used in astronomy, typically defined based upon some combination of the physics being studied and atmospheric transmission.! For all filters one can define a resolution, R=!/"!.! Filters are generally considered broad, medium, or narrowband depending upon the resolution.! Very Rough Guide! Broad: R<10! Medium: R~10-50! Narrow: R>50! Make sure you know which filters you are using for your projects. www.noao.edu/kpno/mosaic/filters

Broadband Filters Johnson-Cousins Filter Set! UBVRI! Classical filter set! Ultraviolet (U)! Blue (B)! Red (R)! Infrared (I)! Optical, very near IR! Wavelength cutoffs not very sharp www.fli-cam.com/images/bessell.gif

Broadband Filters Sloan Filter Set! g r i z! Relatively new! Sharp cutoffs! Used for Sloan Digital Sky Survey! Optical and very near IR! No red cutoff for z www.noao.edu/kpno/wiyn

Broadband Filters Many Different Systems Kron Washington... Even filters on the same system will have slightly different transmission KPNO MOSAIC FILTERS http://pleiadi.pd.astro.it/isoc_photsys.00/filters1.jpg www.noao.edu/kpno/wiyn

Narrowband Filters Typically target specific emission lines! H-alpha! Lyman-alpha! OII! OIII! etc... www.noao.edu/kpno/mosaic/filters

Reducing CCD Imaging Data Note: This lecture is largely comprised of examples that are not part of the posted notes.