TYPE APPROVAL CERTIFICATE

Similar documents
TYPE APPROVAL CERTIFICATE

with type designation(s) ECO38, -40, -43, -46 and ECP32, -34, 3 phases, 4 poles, single or double bearings, brushless A.C. generator.

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

TECHNICAL DATA. Type. TMC2X Design Specification. Category B ATEX Certificate. Code of Protection. IECEx SIR X Code of Protection

HazLoc Essential Guides: Cable Glands

Explosion Proof Audible Signal db(a) Series YA60

Pendant Light Fitting IEC Series 6470/2

Explosion Proof Audible Signal db(a) Series YA60

Pressure Measurement Transmitters for applications with advanced requirements (Advanced)

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection Part 2 of 2

KEL 183 Cable entry frames

EXPlora. Introduction

EXEL. Ex de. - Double locking system operated by hexagonal-head tool - Double channel electronic ballast - Zones 1, 2, 21, 22. G13 bi-pin lamp holder

PYROTENAX TERMINATION KITS COMMERCIAL WIRING. For Pyrotenax copper sheathed mineral insulated (MI) wiring cable

Installation instructions Ex frames

Pendant Light Fittings Series 6050

I Ex-protected connectors exlink I

Emerging Subsea Networks

KVT Split cable glands

8 Installation Equipment

Mechanical flow switch for On/Off control

Level Measurement Point level measurement - RF Capacitance switches

High Performance TOR-SPRING EMI/RFI Cord Grips

Revision 1.0 Parts List Minor

AGRO. The Cable Glands.

Revision 1.0 Parts List Salvador 1~, 3~

Installation instructions Cable transit device Roxtec RS ES Ex

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

Pressure transmitter For applications in hazardous areas Model IS-3

Revision 3.0 Parts List Salvador 1~, 3~

EMC cable glands. AGRO cable glands for interference-free cable installations.

FLEXIBLE CONDUIT AND ACCESSORIES

7 Lighting Technology

Catalog. Industrial Plugs & Sockets The complete range

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

Champ-Pak Wall Pack Luminares

Revision 2.0 Parts List Minor

XML LED X M L L E D. Explosionproof Linear LED Lighting

TFRN Industrial RTD temperature sensor. CombiTemp TM

Illustrated Feature. Options

NEW. Datasheet. Field wiring Cabtite Easy Cable Entry System!

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

TFRH Hygienic RTD temperature sensor. CombiTemp TM

EMC 2 CABLE GLANDS INTRO EMC 2 SERIES. Tighten the cable gland to the housing. Remove outer sheath of shielded cable. Insert cable until EMC spring.

Seaflex Beachflex. Joint Closures SEAFLEX BEACHFLEX JOINT CLOSURES

Revision 2.0 Parts List Minette 1~, 3~

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

RCA3 SOLENOID PILOT VALVES PENTAIR CLEAN AIR SYSTEMS

VITALink Taped Splice Straight Through Crimp

Level Measurement Point level measurement RF Capacitance switches

Revision 3.0 Parts List Minex 1~ Minex Lite, Minex 3~

EXLUX ECOLUX C-LUX 6480 Series

TURCK Network Media Products

Inductive sensor With analog output BI15-M30-LI-EXI

SPECTRUM. cordgrip connectors AMERICAN FITTINGS. SPEC-grade. Corporation 1/2 to 2. Made in the USA. Put a Little Color on Your Cords

Pilot Valves and Nema 4 Enclosures. Innovative Environmental Solutions

Installation instructions Roxtec RS ES Ex


DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

Liquid Level Sensor AKS 4100U

Absolute Encoders Multiturn

Rosemount 1151 Smart Pressure Transmitter

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

Product group 1. Product description. At a glance. Cable entry systems for entering pre-terminated cables

HN Connectors. Automatic Connector. Introduction. Contents. 631/ FAX 631/

Certificate No.: i IECEx SIR issue No.:1 9.!~~~t~I~t.CJ!y:... Issue No.1 ( ) Status;

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.

Inductive sensor NI3-EG08K-Y1-H1341

18mm ECAM Cable Entry Port

Installation instructions Roxtec RM BG systems

EX-PROTECTED PORTABLE POWER SUPPLY UNITS

Model # of Colors Colors Input Connection 1 K90TLGRPQ 2 Green, Red K90TLGYRPQ 3 Green, Red, Yellow K90TLBGYRPQ 4 Blue, Green, Yellow, Red

EXLUX ECOLUX 6480 Series

Inductive sensor BI1.5-EG08K-Y1

GOYEN PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS PRODUCT LEAFLET

KVT Split cable glands

Liquid Level Sensor Type AKS 4100U

Installation instructions Roxtec RM BG B systems

Winch Adjustable Feed Level Tubes for the Adult Turkey Feeder Installation & Operator s Instruction Manual MF /99

TFRN Industrial RTD temperature sensor. CombiTemp TM

Liquid Level Sensor Type AKS 4100/4100U

Amphenol. Circular. Connectors C 16-1 / C Circular Connectors. Amphenol-Tuchel Electronics

3 Cleaning. 4 Technical data

Safety dialogue solutions

Installation instructions Roxtec RM PE

S-503, S-570, SX15-45 and SX15-45M 45 OHM TALKBACK SPEAKERS

Control cabinet interface and cable entry systems

LIGHTING: ENCLOSED AND GASKETED AREA FLUORESCENT. Applications. Illustrated Feature. Certifications and Compliances

Parts List _2.1. Flygt /.890

PROPORTIONAL VALVES Sentronic plus

Installation instructions Roxtec RM ES

CONSTRUCTION SPECIFICATION FOR TRAFFIC SIGNAL EQUIPMENT

Flygt Handleiding voor installatie, bediening en onderhoud

MID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J

PILOT VALVES AND NEMA 4 ENCLOSURES PENTAIR ENVIRONMENTAL SYSTEMS

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Optical Signal Devices. Free-standing Beacons

Transcription:

TYPE APPROVAL CERTIFICATE Certificate No: TAE000010X File No: 828.90 Job Id: 262.1-010486-4 This is to certify: That the Cable Gland with type designation(s) ADE Issued to COOPER CAPRI SAS (EATON GROUP), is found to comply with DNV GL rules for classification Ships and offshore units Application : Hazardous areas cable glands & cable gland's accessories. Product(s) approved by this certificate is/are accepted for installation on all vessels classed by DNV GL. This Certificate is valid until 2020-12-31. Issued at Høvik on 2016-03-29 DNV GL local station: Marseille for DNV GL Approval Engineer: Nicolay Horn Marit Laumann Head of Section This Certificate is subject to terms and conditions overleaf. Any significant change in design or construction may render this Certificate invalid. The validity date relates to the Approval Certificate and not to the approval of equipment/systems installed. Form code: TA 1411a Revision: 2014-11 www.dnvgl.com Page 1 of 6 DNV GL 2014. DNV GL and the Horizon Graphic are trademarks of DNV GL AS.

Name place of manufacturers COOPER CAPRI SAS NOUAN FUZELIER, France Cooper Electric Changzhou Jiangsu China Product description ADE-1F2, ADE-1F2-Anchorage, 1F2-DS, ADE-4F, ADE-5F, ADE-6F, ADE-1FC & ADE-6FC cable glands ADE-1F2, IEC60079-0:2011, IEC60079-1:2007, IEC60079-7:2006, The user shall provide additional clamping of the cable nearby to the enclosure. A Cooper Capri Clamping module can be used. -30 to +80 C with Neoprene sealing ring -60 to +140 C with Silicon sealing ring Neoprene or Silicone Unarmoured Gland size n 3 to n 17, for cable outer diameter from Ø 2.75 to104mm Clamping module, Shroud, Locknut, Earth-tag, Sealing washer ADE-1F2 Anchorage, IEC60079-0:2011, IEC60079-1:2007, IEC60079-7:2006, -30 to +80 C with Neoprene sealing ring -60 to +140 C with Silicon sealing ring Neoprene or Silicone Unarmoured Gland size n 3 to n 17, for cable outer diameter from Ø 2.75 to104mm Shroud, Locknut, Earth-tag, Sealing washer Form code: TA 1411a Revision: 2014-11 www.dnvgl.com Page 2 of 6

ADE-1F2 DS, IEC60079-0:2011, IEC60079-1:2007, IEC60079-7:2006, -30 to +80 C with Neoprene sealing ring -60 to +140 C with Silicon sealing ring Neoprene or Silicone Unarmoured Gland size n 3 to n 17, for cable outer diameter from Ø 2.75 to104mm NPT thread size: ⅜, ½, ¾, 1, 1 ¼, 1 ½, 2, 2½, 3, 3½, 4. Shroud, Locknut, Earth-tag, Sealing washer ADE-4F. -30 C to +80 C with Neoprene sealing ring -60 C to +140 C with Silicone sealing ring Brass (option of stainless steel, marin bronze or aluminium versions) Neoprene or Silicon Armoured or braided Gland size n 4 to n 17 for cable outer diameter from Ø 4,5 to 104 mm Integrated or Independent Clamping flanges; Shroud, Locknut, Earth tag, Entry sealing washer Form code: TA 1411a Revision: 2014-11 www.dnvgl.com Page 3 of 6

ADE-5F. -30 C to +80 C with Neoprene sealing ring -60 C to +140 C with Silicone sealing ring Brass (option of stainless steel, marin bronze or aluminium versions) Neoprene or Silicon Armoured or braided Gland size n 4 to n 17 for cable outer diameter from Ø 4,5 to 104 mm Integrated or Independent Clamping flanges; Shroud, Locknut, Earth tag. Sealing washer ADE-6F With braided cable, the user shall provide additional clamping of the cable nearby to the enclosure. A Cooper Capri Clamping module can be used. -60 C to +80 C with Silicone internal sealing (Diaphragm) and Neoprene or Silicone external sealing ring. Neoprene or Silicon Armoured or braided N 5 to N 11, for cable outer diameter from Ø 6 to 48 mm Metric thread size: 16, 20, 25, 32, 40, 50, 63. NPT thread size: ⅜, ½, ¾, 1, 1 ¼, 1 ½, 2 Clamping flanges, Shroud, Locknut, Earth-tag, Sealing washer Form code: TA 1411a Revision: 2014-11 www.dnvgl.com Page 4 of 6

ADE-1FC All sizes N 4 to N 16: Additional classification for sizes N 11 to N 16: -60 C to +80 C with internal TSC Compound & Neoprene or Silicone external sealing ring. TSC Compound and Neoprene or Silicone external sealing ring Unarmoured. N 4 to N 16, for cable outer diameter from Ø 4 to 93 mm Metric thread size: 16, 20, 25, 32, 40, 50, 63, 75, 90, 110. NPT thread size: ⅜, ½, ¾, 1, 1 ¼, 1 ½, 2, 2½, 3, 3½, 4. Clamping flanges, Shroud, Locknut, Earth-tag, Sealing washer ADE-6FC All sizes N 5 to N 17: Additional classification for sizes N 11 to N 17: -60 C to +80 C with Silicone internal sealing (diaphragm). TSC Compound and Neoprene or Silicone external sealing ring Armored or braided cable N 5 to N 17, for cable outer diameter from Ø 6 to 104 mm Metric thread size: 16, 20, 25, 32, 40, 50, 63, 75, 90, 110. NPT thread size: ⅜, ½, ¾, 1, 1 ¼, 1 ½, 2, 2½, 3, 3½, 4. Clamping flanges, Shroud, Locknut, Earth-tag, Sealing washer Application/Limitation Manufacturer s application instructions to be followed. Manufacturer s assembly instructions to be followed. The information related to Ex certification from recognised test institution is given as information only. Form code: TA 1411a Revision: 2014-11 www.dnvgl.com Page 5 of 6

Approval documentation Tests carried out tests in according to IEC 60079-0, IEC 60079-1, and IEC 60079-7, UL standard. Marking of product Name of manufacturer type designation Ex rating. Periodical assessment The scope of the periodical assessment is to verify that the conditions stipulated for the approval is complied with and that no alterations are made to the product design or choice of materials. The main elements of the assessment are: Inspection on factory samples, selected at random from the production line (where practicable) Results from Production Sample Tests (PST) and Routines (RT) checked (if not available tests according to PST and RT to be carried out) Review of type approval documentation Review of possible change in design, materials and performance Ensuring traceability between manufacturer s product type marking and Approval Certificate. Assessment to be performed at least every second year. END OF CERTIFICATE Form code: TA 1411a Revision: 2014-11 www.dnvgl.com Page 6 of 6