HazLoc Essential Guides: Cable Glands

Similar documents
TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

3M Better Buried Closures

Optical Distribution Box 300 Installation Guide. Version : R0.0

Instrumentation Cables

3M Better Buried Compound Compression Closure System

AGRO. The Cable Glands.

IndyGo Facility Upgrades Project 35671EE

CONSTRUCTION SPECIFICATION FOR TRAFFIC SIGNAL EQUIPMENT

TRANSMISSION ENGINEERING STANDARD TES-P , Rev. 0 TABLE OF CONTENTS 1.0 SCOPE 2.0 CABLES SPLICES

3 Cleaning. 4 Technical data

3M Better Buried Closure (with 3M Scotchlok Shield Bond Connector 4462-FN and 3M High Gel Re-enterable Encapsulant 8882)

3M Distribution Box (DDB)

e-enterable Fiber Optic Splice Closure (Re-Enterable Aerial Closure for Access Service)

WARNING VGTWC VGF-1. Model No. Galvanized Steel Thimble and Wire Rope Cable Termination Kit

3 Foam Sealed Closure 2" (50 mm) with Compound Compression

EMC cable glands. AGRO cable glands for interference-free cable installations.

Trusted TMR I/O SmartSlot Slot Cables

Cambria County Association for the Blind and Handicapped 175 Industrial Park Road Ebensburg, PA Prepared for: Prepared by:

7 Lighting Technology

Gel-sealed in-line fiber optic closure

Contents. Track Circuit Rail Connection Components. Yellow Bonding Kits and T.P.W.S Joint and Termination Kits


Fiber Optic Splice Closure GPJ Instruction Manual

XS_-EU. M8 and M12 Sensor Connectors. Ordering Information

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division

Instructions. Cable with Armor F CAUTION. October Rev A

Flexible Cord. Inside this section

EXEL. Ex de. - Double locking system operated by hexagonal-head tool - Double channel electronic ballast - Zones 1, 2, 21, 22. G13 bi-pin lamp holder

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

VITALink Taped Splice Straight Through Crimp

Explosion Proof Audible Signal db(a) Series YA60

Installation instructions Cable transit device Roxtec RS ES Ex

EXPlora. Introduction

Quick Term III. 3M Cold Shrink 3 Core Indoor Termination. 3.3 kv mm 2

HN Connectors. Automatic Connector. Introduction. Contents. 631/ FAX 631/

3 SLiC Aerial Closure with Rubber End Seal

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

High Performance TOR-SPRING EMI/RFI Cord Grips

IEC Standard for Luminaires Part 1: General Requirements and Tests, IEC Edition 8, Issued May The

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

DOME OPTIC SPLICE CLOSURE

FIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays

Automatic Connector MHV Connectors MHV Introduction MHV series connectors Contents Polarized mating interfaces Anti-Rock mating interfaces

2178-L/S Series Fiber Optic Splice Case with Gasket

PT9420 Cable Actuated Sensor Industrial ma 0..20mA

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

PEM1126ENG ENGLISH STPKR. TERMINATION KIT FOR PAPER CABLE WITH LEAD SHEATH 1 kv INSTALLATION INSTRUCTION

Installation instructions Roxtec RS ES Ex

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

Scotch Heavy Duty Vinyl Electrical Tape 22

18W Low Energy Dusk-Dawn Bulkhead E-290B

LEGEND POWER SYSTEMS

Catalog. Industrial Plugs & Sockets The complete range

FOSC 450 C6 and D6 Closures

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.

Medium Box for Cable Termination

Installation Instructions

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection Part 2 of 2

Installation Manual for New or Retrofit Installations

Safety dialogue solutions

FLEXIBLE CONDUIT AND ACCESSORIES

Bharat Heavy Electricals Limited HIGH PRESSURE BOILER PLANT, TIRUCHIRAPPALLI CONTROLS AND INSTRUMENTATION/FB

Installation instructions Ex frames

Pendant Light Fitting IEC Series 6470/2

INSTRUCTION AND MAINTENANCE VIDEO MOTORE PROJECTION SCREEN

Instruction Manual MODEL RSP SANITARY ELECTRONIC PRESSURE TRANSMITTER

OPERATION AND MAINTENANCE MANUAL

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

3M Super 23 Electrical Tape

PEM1124ENG ENGLISH. STK TERMINATION KIT FOR PLASTIC CABLE WITHOUT ARMOURING 1 kv STKR TERMINATION KIT FOR PLASTIC CABLE WITH ARMOURING 1 kv

Cable installation guidelines

SBN Pendant Pushbutton Station. Instruction Manual. Part Number: R1 January 2016 Copyright 2016 Magnetek Material Handling

Eddy Current Probe System

KEL 183 Cable entry frames

ELECTRICAL SAFETY INSPECTION REPORT

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

S020 fluorescent tube luminary

18mm ECAM Cable Entry Port

KVT Split cable glands

Signalling Cable Equivalent Sizes

TECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT

Trends and Challenges of HV Cable Systems

TERMINATIONS AND JOINTS FOR XLPE-INSULATED kv MEDIUM VOLTAGE CABLES

2178 Fiber Optic Splice Case and 2181 Cable Addition Kit

Explosion Proof Audible Signal db(a) Series YA60

TECHNICAL SPECIFICATION

PERFORMANCE SPECIFICATION SHEET CONNECTORS, PLUGS, ELECTRICAL, COAXIAL, RADIO FREQUENCY (SERIES SMA (CABLED) - PLUG, PIN CONTACT, CLASS 2)

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR

ECONOMICAL 36 kv CABLE SYSTEM FOR THE BELGIAN NETWORK

AMERICAN NATIONAL STANDARD

KVT Split cable glands

STANDARD FOR MULTI-DWELLING UNIT (MDU) OPTICAL FIBER CABLE. Publication S First Edition - June 2012

Installation instructions Roxtec RM ES B

PERFORMANCE SPECIFICATION SHEET CONNECTORS, PLUGS, ELECTRICAL, COAXIAL RADIO FREQUENCY, (SERIES TNC (CABLED), PIN CONTACT, RIGHT ANGLE, CLASS 2)

Inductive sensor NI3-EG08K-Y1-H1341

Transcription:

HazLoc Essential Guides: Cable Glands Intertek Deeside Lane, Chester, CH1 6DD UK hazloc@intertek.com 01244 882590 www.intertek-hazloc.com

Contents Contents... 1 Introduction... 1 Legislation... 3 Cable Types... 4 Types of Cable Glands... 4 Gland Sizes... 5 Marking... 5 Construction... 6 Gland Selection Guide... 7 IP Rating... 8 Earthing... 8 Corrosion... 8 Nickel Chromium/Stainless Steel Glands... 9 Gland Types... 9 Cable Glands A Type... 9 Cable Glands B Type... 10 Cable Glands C Type... 10 Cable Glands E Type... 11 Electrolytic Action... 11 Gland Kits... 11 Shrouds... 11 Locknuts... 12 Contacts... 13 About the Author: Peter Roberts... 13 Introduction Cable glands are used to terminate electric cables to electrical equipment or electrical enclosures. For the majority of electrical installations cable glands are required to be fitted. The type of gland selected will be dependant on a number of factors: a) Type of installation: domestic, commercial or industrial; b) Indoor or outdoor environment; c) Explosive atmosphere; d) Corrosive atmosphere; e) Cost www.intertek-etlsemko.com 1

Cable glands are regarded as a low priority device and are often the last thing to be considered when purchasing equipment and cables. Cable glands are critical safety devices in the overall electrical system of a plant or installation. The importance of using and selecting the correct cable gland type should not be overlooked. There are various types of cable glands from the simple A type gland right through to the compound barrier gland. This booklet is intended as a guide to the end user (the electrician) to help in understanding the different types of cable glands available and when to select one type of gland rather than another type. Fig 1: Standard industrial cable gland Cable glands are designed to be used on armoured or non-armoured cables. It must be emphasised that it does not matter what type of gland is used or how much it costs, the gland must always be fitted in accordance with the gland manufacturers instructions. www.intertek-etlsemko.com 2

Legislation Cable glands are designed, manufactured and tested to meet the stringent standards laid down by British, European and international standards. The flow chart shown below shows the standards used in the UK over the last forty years. The European Standard EN 50262 for metric cable glands was published in September 1998. As a result the previous UK national standard BS 6121 for mechanical cable glands was withdrawn. EN 50262 was published in the UK as BS EN 50262 in March 1999. The latest edition of BS 6121 part 1- mechanical cable glands. Armour glands. Requirements and test methods and part 5 - code of practice for selection, installation and inspection of cable glands and armour glands was published in 2005. www.intertek-etlsemko.com 3

Cable Types For cable types refer to booklet entitled Cable used in potentially explosive atmospheres. Types of Cable Glands BS 6121 specified requirements for the design and construction of cable glands and gave type designations to glands. The following designations are sometimes used by cable gland manufacturers in their product codes. The basic designations of the glands where as follows: Type A1. For unarmoured cable with an elastomeric or plastic outer sheath, where the function of the gland is to secure the outer sheath of the cable. Type A2. As type A1, but with an IP66 seal between the outer sheath and gland. Type A3. As type A1, but with an electrical bond for the metallic inner sheath. Type A4. As type A2, but with an electrical bond for the metallic inner sheath. Type B. For armoured or wire braid cable, where the function of the gland is to secure the armour or metallic braid and to provide electrical continuity between such armour or braid and the threaded fixing component of the gland. Type C. For armoured or wire braid cable with elastomeric or plastic outer sheath. As type B, but with an IP66 seal between outer sheath and gland. Type D1. For armoured or wire braid cable with elastomeric or plastic outer sheath. As type B, but with an IP66 seal between inner sheath and threaded fixing component. Type D2. As type D1, but with an electrical bond for the metallic inner sheath. Type E1. For armoured or wire braid cable with an extruded elastomeric or plastics inner sheath and elastomeric or plastics outer sheath. As type C, but with an IP66 seal between inner sheath and gland and between the inner sheath and threaded fixing component. Type E2. As type E1, but with an electrical bond for the metallic inner sheath. www.intertek-etlsemko.com 4

Glands of type B, C, D1, E1 and E2 suitable for armoured or wire braided types of protection shall be identified by a suffix, added to the designation, to indicate the type of protection for which the gland is suitable. The suffix for each type of protection shall be as follows. Single wire armoured Pliable wire armoured flexible Wire braided Aluminium strip armoured Double steel tape armoured W T X Y Z If a gland is suitable for more than one type of protection, all of the relevant suffixes are used. Note: The following is an example of type designations Type CW. A gland for armoured cable with an IP66 seal between outer sheath and gland, for single wire armoured cable. Gland Sizes There are numerous sizes of glands. Refer to cable gland manufacturers literature for full details. Marking All glands shall be marked in accordance with the appropriate standards. An appropriate part of the gland shall be legibly and permanently marked with the following particulars: a) the number of this standard, i.e. BS EN 50262 b) the size designation of the gland c) Whenever possible, the type of the gland and the appropriate suffix. www.intertek-etlsemko.com 5

Construction Cable glands for armoured or braided cables generally have an armour-locking ring refer to figure 2 with the exception of the B type gland. Refer to figure 4. Fig 2: Armoured cable gland The length of the thread on the hub is dependant on the size of the cable gland e.g. a gland size of 20 the hub length is approximately 16mm whilst for a larger cable gland size 90 then the hub thread length is 25mm. Fig 3: Steel wired armoured cable plus gland The armour wires are trapped between a locking ring and the armour cone of the threaded fixing component by the action of screwing the gland body to the hub. www.intertek-etlsemko.com 6

This ring will continue to trap the armour wires even if the gland body became loose through heat cycling, vibration or during maintenance. The earth continuity can be visually inspected and electrically tested after installation. This is not possible to do with the two-part gland because of the absence of the locking ring. See figure 4. If the gland body is slackened off the earth continuity has gone and there is nothing to inspect. Figure 4: Two Part Gland (C Type) Outdoor cable glands contain either one seal or two seals. As the cable gland is tightened it compresses the seal, which grips the cable. The seals have been tested to IP66 and meet the requirements of the standard. Gland Selection Guide The following list should be used to ensure that the cable gland selected is correct: Select the type of cable and identify the correct gland type Check the type, size and voltage rating of the cable. Check ACTUAL size of cable over the inner sheath. Check ACTUAL size of overall cable diameter. Check the size and type of armour or braiding, if any. Check any special environment conditions including enclosure material in relation to corrosion. Check whether installation is in Hazardous Areas, and consider seal protection for indoor/outdoor use. Check that an entry thread seal is required for IP66 conditions. Check accessories, (i.e. Shrouds, slip on earth tags, locknuts etc). www.intertek-etlsemko.com 7

IP Rating To maintain IP66 between the equipment and the cable gland, the use of a nylon entry seal is recommended. Refer to section on sealing washers. A threaded joint sealed with a suitable setting compound will maintain IP66. Care should be taken however, to preserve any electrical continuity requirement. With this in mind, glands in conjunction with good quality enclosures (at least 6mm thick) shall maintain an IP rating of IP54 without any additional sealing. Earthing Electrical continuity is normally achieved via the screwed entry into metal boxes. Whenever there is a clearance hole entry situation it is essential to obtain direct metal-to-metal contact between the glands, and therefore an earth tag is used between the gland and the enclosure. For situations where there is a requirement for positive earthing due to high potential currents, the use of armouring alone as the only earthing is not recommended, a range of integral earth glands are available. Insulated adaptors are available for installations where it is necessary to avoid connection between the cable armour/braid and earth at one end of the route, e.g. the break in the earth loop that can otherwise generate spurious signals. Corrosion The standard material used in gland manufacture in the UK is brass; the majority of other countries tend to go for nickel chromium or in special conditions stainless steel. Brass and nickel chromium is suitable for the majority of applications. However, certain environments, notably ammonia and derivatives can cause severe corrosion problem for cable glands. Due to the possibility of bi-metallic corrosion and electrolytic action, especially in moist atmospheres, it is advisable to avoid the contact of dissimilar metals where possible. Brass glands installed in plants or outside areas (moist conditions) should be fitted with brass locknuts. www.intertek-etlsemko.com 8

Nickel Chromium/Stainless Steel Glands Resistant to alkalis, like caustic and potash; to salt solution and brines, like seawater; to acid gas environments, like those found in the petro-chemical industry. The glands also have good resistance to ammonia solutions; organic acids, like lactic or acetic, like hydrochloric or sulphuric. Gland Types Cable Glands A Type A type glands more commonly known as stuffing glands. There are two types of A gland. A1 and A2, A1 is retained on the cable whilst the A2 gland seals and retains on the cable. Suitable for unarmoured, plastic or rubber sheathed cables. Indoor and outdoor applications. For unarmoured, plastic or rubber sheathed cables. Suitable for most indoor and outdoor applications. Plastic or brass Seal rated to IP66 (A2 version) A1 Cable Gland - A1 cable gland, Plastic only (IP4X) non-certified version only. A2 Cable Gland - A2 cable gland, Plastic and/or brass (IP66) non-certified and certified versions available. www.intertek-etlsemko.com 9

Cable Glands B Type Suitable for single wire armoured, plastic or rubber sheathed cables. Application - for use in dry, indoor situations only. Brass only IP30 Cable Glands C Type Suitable for cables that are: Plastic or rubber sheathed Extruded or lapped bedded Armoured or braided Outer seal grips sheath of cable Seal rated to IP66 For use in most climatic conditions weatherproof and waterproof. Brass or Stainless steel Design has separate armour locking ring. www.intertek-etlsemko.com 10

Cable Glands E Type Suitable for cables that are: Plastic or rubber sheathed Extruded or lapped bedded Armoured or braided Outer seal grips sheath of cable Inner seal grips bedding layer of cable Inner and outer seal rated to IP66 For use in most climatic conditions weatherproof and waterproof. Brass or Stainless steel Design has separate armour locking ring. Electrolytic Action There maybe in some cases electrolytic action between two dissimilar metals e.g. gland and enclosure if incompatible materials are selected. This can shorten the lifetime of the gland and the enclosure Gland Kits Advantage: convenient, ready to use. Shrouds For fitting over cable glands where additional protection against onerous weather conditions and corrosion is required. Three types of shrouds available: PCP: used in most hostile conditions and cannot be effected by ultraviolet rays contained in sunlight. PVC: for fast and simple installation. LSF: Low smoke and fume www.intertek-etlsemko.com 11

Cable gland shrouds can be used where additional protection against environmental conditions is required. Great care should be taken to ensure that the shroud is a snug fit over the cable gland and where necessary the shroud should trimmed to suit the cable diameter. Locknuts There are five types of locknuts available, these are: Mild steel; Stainless steel; Brass; Aluminium; Plastic; Each type has its advantages and disadvantages. Brass locknuts are recommended for most outdoor industrial applications. For corrosive environments, stainless steel locknuts may be the preferred option. Aluminium locknuts should only be used with aluminium glands. Cable glands fitted into clearance hole should be secured by a locking device e.g. locknut, inside the apparatus which is capable of meeting the gland torque requirements. Where a lock nut is the sole means of providing earth continuity to the equipment, it should be brass or mild steel. www.intertek-etlsemko.com 12

Contacts Technical Peter Roberts peter.roberts@intertek.com Sales Asif Akbar asif.akbar@intertek.com Intertek, Deeside Lane, Chester, Flintshire, CH1 6DD, UK Telephone: +44 (0)1244 882590 About the Author: Peter Roberts Peter started work with the National Coal Board (British Coal) in 1970 as an indentured apprentice electrician. Following a 4-year apprenticeship he worked as a mine craft electrician, and then after further additional studies, became a supervisory electrician and finally qualified as an Electrical Engineer for the mines. In 1987 he moved from the coal mines to the chemical industry and was employed as an Electrical Technician and ultimately becoming the electrical inspector for the 150 Acre site with responsibility for the electrical infrastructure both for the nonhazardous and hazardous areas associated with a top tie COMAH site. Over his many years in the industry, Peter has worked on all types of electrical equipment both hazardous and non-hazardous and on a wide range of voltages from 7.5v dc up to and including 11000 volts. After 15 years in the chemical industry he joined Epsilon, which has recently become part of Intertek. He is now one of the Principal Engineers associated with the site services department with responsibility for on-site work at locations throughout the world. Peter is also involved as Lecturer/Trainer/Assessor for the UK s national recognised CompEx Training scheme. For more information on specific testing and certification information, please contact Intertek at 1-800-WORLDLAB, email icenter@intertek.com, or visit our website at www.intertek-hazloc.com. Copyright Notice & Disclaimer This publication is copyright Intertek 2009 and may not be reproduced or transmitted in any form in whole or in part without the prior written permission of Intertek. While due care has been taken during the preparation of this document, Intertek cannot be held responsible for the accuracy of the information herein or for any consequence arising from it. Clients are encouraged to seek Intertek s current advice on their specific needs before acting upon any of the content. This booklet is for the exclusive use of Intertek s Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this information. This booklet may not be reproduced and distributed in whole or part to third parties without the express permission of Intertek www.intertek-etlsemko.com 13