Corona and Tracking Conditions in Metal-clad Switchgear Case Studies

Similar documents
Using Ultrasound and Infrared Technologies for Metal-Clad Switchgear Inspections

BY ADRIAN MESSER, UE Systems, Inc.

Methods of Inspection to Determine the Presence of Potential Arc Flash Incidents

Incorrect Temperature Measurements: The Importance of Transmissivity and IR Viewing Windows

Enhanced Diagnostics through Ultrasound Imaging

TRANSMISSION ENGINEERING STANDARD TES-P , Rev. 0 TABLE OF CONTENTS 1.0 SCOPE 2.0 CABLES SPLICES

FORENSIC CASEBOOK. By Bob Huddleston, Eastman Chemical Co. One of the most common. reasons for marriage failure

GESTAMP CHATTANOOGA, LLC CHATTANOOGA, TENNESSEE

SECTION MEDIUM VOLTAGE CABLE INSTALLATION. 1. Section Underground Ducts and Manholes.

220KV EHV NETWORK AT RELIANCE JAMNAGAR REFINERY COMPLEX

EG4015. Digital Generator Governor Controller User Manual

ELECTRICAL SAFETY INSPECTION REPORT

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

Student Services & Classroom Addition

What you can t hear can hurt you!

ELECTRICAL SAFETY INSPECTION REPORT. MTM Garments Ltd.

Dry Type Transformers. Section 10. BuyLog Catalog 10-1

PanelView 1400e CRT Maintenance


Operating Experience and Reliability Improvements on the 5 kw CW Klystron at Jefferson Lab

INSTRUCTION DE SÉCURITÉ SAFETY INSTRUCTION Mandatory as defined in SAPOCO/42 FIRE PREVENTION FOR CABLES, CABLE TRAYS AND CONDUITS

A Unique Power Supply for the PEP II Klystron at SLAC*

Achat 115 Sub A active subwoofer. user manual

3M Sensored Termination (15 kv) QX-T15I-vi1-E

DSP 18 Sub active subwoofer. user manual

3 Cold Shrink Products

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

TRF STEP-DOWN TRANSFORMER USER MANUAL

ELECTRICAL SAFETY FOLLOW UP INSPECTION REPORT (8th) Factory Name Address Factory ID

SIR-GM1 GM CLASS-2 BUS COMPATIBLE SIRIUS SATELLITE RADIO TUNER

Minimum qualifications for the Telecommunications Engineer are: A. Texas Licensed Profession Engineer (PE)

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

Mediacom Upgrade/Splicing Procedures (based on original document from Corporate dated 4/16/98)

ELECTRICAL SAFETY INSPECTION REPORT

3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT

Underground Cable Diagnostic Testing Utilizing Partial Discharge Technique

Technical Specifications

S Regulators. Supplement 1. Contents. Control Replacement Assembly Installation Instructions Supplement

KRF EMC Filters Installation, Operation and Maintenance Manual

OneFit Cable test and temporary earthing truck instruction manual

SITE All work shall be performed at Center Park Substation (1895 Kernan Blvd, Jacksonville, Fl ). DATE: 04/03/2018

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

TERMINATIONS AND JOINTS FOR XLPE-INSULATED kv MEDIUM VOLTAGE CABLES

About vacuum power tubes.

An introduction to Kabeldon cable accessories kv

USER MANUAL. 22" Class Slim HD Widescreen Monitor L215DS

Installation Guide VL-MV10. Model No.

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

IndyGo Facility Upgrades Project 35671EE

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Cold Shrink Three-Conductor Splice Kit QS-III for use on Armor and Non-Armor Cables Instructions IEEE Std kv Class 250 kv BIL

Dry Type Transformers Section 10

Photo IC type high sensitive light sensor

POLICY & APPLICATION GUIDE FOR 11kV POLYMERIC CABLES

SPECIAL SPECIFICATION 6559 Telecommunication Cable

M4000 Diagnostic Test System For Power Apparatus Condition Assessment

3M Better Buried Compound Compression Closure System

Owner s Manual. TFT-LCD TV High Brightness & Contrast NICAM/A2 Stereo Sound MODEL: L15SV6-A0, L17LV6-A1,L20AV6-A0 L17L6A-G1,L20L6A

FEATURES 1. Built-in optical filter for spectral response similar to that of the human eye

Installation Manual IPT Installation of skillet systems with 125 A track current. MV a-E.

/ PAT01 USER MANUAL

An Introduction to Vibration Analysis Theory and Practice

Jul03 Rev C EC

User Manual TL-TP70-HDIR 70m Extender with ARC and IR All Rights Reserved Version: TL-TP70-HDIR_180723

Henkel Installation Handbook LINEGUARD 2001

Wired Troubleshooting Manual

ANALYSIS OF FAILURE IN POWER CABLES FOR PREVENTING POWER OUTAGE IN ALEXANDRIA ELECTRICITY DISTRIBUTION COMPANY IN EGYPT

28 & 32 & 40 & 55 & 65 & 84-INCH TFT-LCD 4K MONITOR

Model CB 160 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

01. Stay safe. Privacy information

3M Motor Lead Inline Splice 5331, 5332, 5333 & 5334

XPert Filtered Balance Systems

3M Scotchcast Flexible Power Cable Splice Kits 82-F Series

STC-33 Product Specification VGA Progressive Scan Machine Vision Board Camera

COOPER POWER SERIES. 600 A 15/25 kv class DT625 T-body installation and cable preparation instructions. Deadbreak Apparatus Connectors MN650017EN

ICS Digital Menu. Installation Guide Version 1.1

SPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment

User Manual TL-2X1-HDVC 2x1 HDMI & VGA Switcher with Control All Rights Reserved Version: TL-2X1-HDVC_160630

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Operating instructions

Photovoltaic Module Installation Manual (IEC)

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment

SPECIAL SPECIFICATION 8540 Telecommunication Cable

MS2540 Current Loop Receiver with RS485 Communication

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

HEALTH AND SAFETY MANUAL

AT&T January, 2012 Revised December, 2018 TABLE OF CONTENTS SECTION 1--INTRODUCTION...1-1

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

PEM1126ENG ENGLISH STPKR. TERMINATION KIT FOR PAPER CABLE WITH LEAD SHEATH 1 kv INSTALLATION INSTRUCTION

3M Scotchcast Mine and Portable Cable Splice and Jacket Repair Kit M-40

LED Driver Linear / area fixed output

ELECTRICAL INCIDENT REPORT BUSHFIRE NEAR 22 NUKKLGUP LOOP YALLINGUP WESTERN AUSTRALIA 5 JANUARY Report prepared by: EnergySafety WA EIS

User Manual TL-2X1-HDV 2x1 HDMI & VGA Switcher All Rights Reserved Version: TL-2X1-HDV_160630

DATAGAUSS XL HARD DRIVE DEGAUSSER

Surface Mount Multilayer Ceramic Chip Capacitors for High Temperatures 200 C

LITE-ON TECHNOLOGY CORPORATION

Trends and Challenges of HV Cable Systems

Transcription:

Corona and Tracking Conditions in Metal-clad Switchgear Case Studies By James Brady, Level-III Certified Thermographer Brady Infrared Inspections, Inc. 935 Pine Castle Court, Stuart, FL 34996 (772) 288-9884 jbrady@bradyinfrared.com www.bradyinfrared.com Introduction Electrical discharge in the form of corona and tracking has caused many failures in metal-clad switchgear with little advanced warning or understanding of the cause. This is especially frustrating for the end-user when infrared technology is being utilized as a predictive tool to prevent such occurrences. Because corona and tracking conditions are voltage problems that rarely produce heat, they go undetected during a typical infrared inspection. Fortunately, the combined use of ultrasound and infrared can enhance a switchgear inspection program by providing early detection of both heating and non-heating problems. Several years ago, I was introduced to ultrasound technology at an IR INFO conference. After realizing the applications and benefits of this predictive maintenance tool, we were soon offering this service as a routine part of our infrared inspection business. That decision has more than paid for itself by finding critical electrical problems for our clients that would have otherwise gone undetected using infrared alone. This presentation will attempt to take the mystery out of the occurrence corona and tracking in metal-clad switchgear by discussing it s occurrence, what to look for during an inspection and case studies that have been documented over the past four years. What Is Corona and Tracking? Corona refers to the faint glow surrounding an electrical conductor of 3500 volts or greater as a result of the ionization of air as the nitrogen in the air breaks down. When corona occurs it creates ozone (detrimental to the human lungs, eyes, etc.), ultraviolet light, nitric acid, electromagnetic emissions and sound.

Ozone is a strong odorous gas that deteriorates rubber-based insulation. If moisture or high humidity conditions exist nitric acids can also be formed that attacks copper and other metals. The electromagnetic emission can be heard as interference on AM radios and the corona sound can be heard by the human ear and be ultrasonic scanning devices. One important point to consider is that unlike infrared that detects heating due to current flow, corona indicates voltage problems and can be present without current flow. High potential in the electrical field is the major dictating factor for its presence. Corona activity is at its strongest on the positive (+) and negative (-) peaks of the 60Hz cycle. Once corona becomes active it leaves behind a conductive tracking path on surfaces and also creates a very conductive cloud of air around itself. A flashover can occur once a tracking pathway is completed from phase to phase or phase to ground (Figure-1). It can also occur from the conductive cloud of surrounding air once it finds a path to ground. Figure-1: Advanced stage of carbon tracks on insulation board and insulated tape wrap on 4160V bus. What Causes Corona? Based upon numerous observed conditions of corona, there are three primary causes for its development, geometric factors, spatial factors, and contamination. Geometric factors include sharp edges on conductors, connections and switchgear cabinet components. This may be the results of sharp or squared tape wraps in conductor terminations, tag ends on conductors, and corners and points on cabinet bracing and support shelves. Spatial factors include small air gap spaces between conductors and other conductors, insulation board, and switchgear cabinet components. This may results from: 1) conductors being tie-wrapped together, 2) conductors touching insulators, conduit, and edges of cabinets, 3) non-shielded cables in contact with grounded surfaces, and 4) bus bars in close proximity to fiber-resin support and insulator material (Figure-2). Page 2

Finally, contamination in the forms of dust, oils/fluids, and other particulates on conductors and insulators will create corona (Figure-3). Corona conditions are exasperated by humid and wet conditions. Figure-2: Caron tracks on insulation board close to 13kV bus bars. Figure-3: Contamination on ceramic bushing caused corona discharge to form. Visible Signs of Corona and Tracking Probably the most noticeable sign of corona will be the smell of ozone, since this is the major by-product of corona. Early stages of corona may not show any visible signs. Mild cases of corona that are caused by metal edges in switchgear cabinets may never be detected by visual inspection alone. Typically, the effects of corona on rubber-based insulators, tape, and insulation board will leave a white, fibrous power residue or dust (Figure-4). This dust is the physical breakdown of the material. Figure-4: White powder/dust residue formed on 13kV power cables that are tiewrapped together forming tight air spaces between each other; ideal locations for Figure-5: Non-shielded 23kV cables in contact with grounded porcelain collars produce corona conditions. Note discoloration of cable in foreground. Page 3

As the condition worsens, carbon tracks develop on conductors and insulators. Depending upon the distance between the phase and ground will determine the time to a flash-over. Others indicators include discoloration and pitting on cable insulation (Figure 5). Usually dull finishes and micro-crack stains on cable insulation will be noticed. In worst case scenarios, cables will be severely deteriorated (Figure-6). Unusual weathering patterns on copper bus and conductors are also good indicators or corona (Figure-7). Humid and wet conditions inside switchgear cabinets will allow nitric acid to form which attacks the copper surface leaving unusual weathering patterns. Cabinets lacking heaters, cabinets with poor weather seals, and those next to wet industrial processes are especially vulnerable to these conditions. Figure-6: Severely deteriorated power feed cable in 4160V switchgear cabinet displaying white power and carbon tracks. Figure-7: Unusual weathering pattern on 13kV copper bus under attack by corona produced nitric acid. Corona and Heating Corona activity can produce a very faint heating pattern due to the molecular disturbance of electrons associated with the ionization of air (personal communication with Dan Ninedorf of Ox Creek Energy Associates Inc.). Depending upon air movement and the intensity of the corona, the delta temperature may or may not be detectable with infrared technology (Figure-8a & 8b). This can be deceiving for the infrared thermographer who is unfamiliar with corona, as this serious condition may only receive a minor severity rating if evaluated on temperature rise criteria alone. Page 4

81.2 F 81 80 AR01: 79.7 F 79 78 SP01: 76.2 F 77 75.7 F 76 Figure-8a & 8b: A temperature rise of 3 F degrees observed on a 13kV bushing that has corona activity between itself and bakelite board insulation. Note white power on insulation board. Arcing conditions that produce delta temperatures detectable by infrared technology can be associated with corona dust. The conductive nature of the white power left be by corona can support arcing conditions (See Case Study 4). Ultrasound Technology Sounds above the normal range of human hearing (20 Hz to 20 kilo-hertz (khz)), is typically thought of as ultrasonic. A frequency range between 20 khz to 40 khz generally covers all of the ultrasonic applications used for predictive maintenance applications; leak detection, stream traps, bearings and lubrication, and electrical discharge. The equipment includes a receiver unit, headphones, and various modular listening devices that attach to the receiver for both airborne and structure-borne scanning. Airborne devices include cone-shaped collectors that capture ultrasonic wave traveling through air. Structure-borne devices include magnetic base collectors and rod attachments used to contact the surface of equipment. Through a process of heterodyning the ultrasound signal is converted by the receiver unit to a low frequency audible signal that can be heard trough the headphones. There is also a read-out display that shows the intensity of the received signal. Using Ultrasound to Detect Corona and Tracking Because corona and tracking problems are occurring in air, it makes senses that the best technique to detect these problems is through airborne ultrasound. Page 5

Ultrasonic waves are very directional in their movement making it relatively easy to track problems back to their source. Because ultrasound wave are directional, they will rebound off surfaces and can be partially and completely blocked. Using common sense and following the unit s strongest received signal will usually point the operator to the problem. The operator can also use blocking techniques to filter out competing ultrasound noises, if necessary. Prior to opening a switchgear cabinet, it should be standard practice to scan ventilation screen openings, the seams around the doors, and the cabinet bolt holes once a few are removed. Typically, advanced cases of corona and tracking will be heard using this initial scan technique. However, the interior geometric design of the cabinet may not always allow the signal to reach the ultrasound collector or may only allow a partial and weak signal to be heard. Likewise, mild cases of corona may have a very weak discharge signal that is not heard until the cabinet is open. If you have any question about the safety of opening a switchgear cabinet, do not open it until an outage can be secured. Other problems that may affect the initial scan are competing ultrasonic noises generated by mechanical vibration from inside switchgear cabinets and hand tools used to open the cabinets. Mechanical vibration signals can sound a lot like electrical discharge signals. By applying light pressure on the sides of cabinets and doors, you can reduce or eliminate a mechanical signal and rule it out as electrical discharge. Opening switchgear cabinets is a risky business that should only be performed by qualified person wearing the appropriate arc-flash protection equipment as prescribe by the NFPA 70-E guidelines. If at all possible, cabinets should be open while de-energized, and then energized for the inspection. If a strong smell of ozone is detected, do not open the cabinet until it is de-energized. Drafting air into a cabinet with advanced corona and tracking conditions may move conductive air over a grounded object and cause a flash-over. Teamwork between qualified persons is a must. If you are an in-house technician with high-voltage switchgear, considered installing hinges on doors and modifying bolts that can be easily handled while wearing gloves. Doors should be opened very slowly. You should minimize your exposure in front of the open equipment. Once open, the inspector should slowly scan the interior of the cabinet making sure to cover the entire area. Both front a back compartments should be scanned, if accessible. Never should the ultrasound instrument or any body parts break the plane of the cabinet or exceed the approach distance for the given voltage class. Page 6

What Are We Listen For? Corona problems will be heard as a continuous buzzing or frying noise. The intensity of this noise will be directly related to the severity of the problem. Tracking problems will sound much like corona problems but will have pauses and possible drops and builds in intensity. Once a problem is detected, the problem should be described, photographed, and recorded, if desired. Because of the dangers involved with getting too close to this type of equipment, using a telephoto lens will help become your eyes to get close to problems. Also, a bright flashlight will help illuminate dark and tight areas where corona problems may occur. Corrective Action You just received word that corona is present in you switchgear. How bad is it? What corrective action should I take? The presence of corona and/or tracking in switchgear is a serious problem that should be addressed as soon as possible. The following corrective actions have been suggested by Mark Lautenschlager, PE and Senior Vice-President of Engineering with High Voltage Maintenance Corporation in an article printed by NETA World, Fall 1998. Any physical sign of breakdown or injury to conductors, insulators and insulation board should be corrected by repairing or replacing the damaged component. Fill air gas with silicon tape, silicon sealant or other corona suppressive compound. Air gaps can also be increased or replaced with porcelain insulators. Smooth sharp edges, apply corona rings, apply semi-conductive tape or compound or wrap edges with metallic screening to form round conductive surfaces. Replace damaged terminations and splices on conductors. Support nonshielded cables from ground. Conclusion Unlike resistance problems associated with current flow that can be detected by infrared, corona is a voltage problem that seldom generates heat. Corona and tracking problems can be easily missed by infrared and remain enigmatic until a major fault occurs that destroys switchgear equipment. The use of ultrasound Page 7

technology compliments an infrared inspection program by increasing ones ability to locate these destructive problems and take corrective action. In most cases, corona and tracking problems provide visual evidence of their existence. Understanding the factors that cause these problems and their physical clues should bring a new awareness to the infrared thermographer. Case Studies Four case studies are presented here that provide a cross section of various problems and conditions associated with corona and tracking problems in metalclad switchgear. Case #1: Tracking Inside 13kV Rack-in Breaker Cabinet Background: During a recent inspection at a substation for an utilities provider, a series of 13kV rack-in breaker cabinets were being scanned with infrared and ultrasound. One the rack-in breakers was completely removed from the main bus cabinet following a recent flash-over. Because of the no load conditions inside the cabinet, infrared was ineffective. However, tracking discharge was easily picked up by the ultrasound scanner. Comments: The most logical explanation for the tracking condition is the problem that caused the initial flashover is still present. The presence of carbon-rich flash residue will only exasperate the situation by providing very conductive material for tracking paths. Avoided Cost: Prevented the potential loss of a main bus responsible for five feeder breakers at a downtown substation. Case #2: Tracking Inside 13kV Load Interrupter Switch Background: During an inspection last year at a citrus industry, the outside ventilation screen on a 13kV load interrupter switch cabinets was scanned using ultrasound. The switch was tied to a step-down transformer which in turn was tied to 480V switchgear, of which the main breaker was open. Because of this, it was determined that the 13kV switch was under very light load. Ultrasound detected a very strong signal characteristic of tracking conditions. The 13kV switch was de-energized and open for visual inspection. Carbon tracks were discovered on the insulation board separating the B- and C-phase fuses. Comments: Fortunately, this condition was found just in time. This switch was scheduled to be brought on-line with load shortly after the inspection and would have undoubtedly failed soon thereafter. Maintenance personnel replaced fuses, cleaned all metal parts and installed new insulation board. Once repairs were complete, the switch was energized and a follow-up ultrasound scan was performed confirming repairs were successful. The switch was then brought on-line with load and ultrasound and infrared were performed, again confirming that repairs were successful. Avoided Cost: Prevented the potential catastrophic loss of a 13kV load interrupter switch responsible for over 20 million gallons of citrus product storage. Page 8

Case #3: Corona inside 13kV Transformer Cable Compartment Background: During an inspection last year at a citrus industry, a pad-mount step-down transformer cabinet was scanned with infrared and ultrasound. Infrared results showed all connections and conductors to be normal. Ultrasound found advanced stages of corona on the 13kV power feed cables entering the transformer cabinet through a 3-inch galvanized conduit. Comments: A visual sign of the corona was white residue power in the small air gap spaces between the cables and the conduit. Avoided Cost: Prevented the potential catastrophic loss of a pad mount transformer and adjacent 13kV load interrupter switch responsible for the plant s feed mill operations. All of the others plant s operations are dictated by the operation of the feed mill. Case #4: Corona and arcing on 23kV Ceramic Bushing Background: During an inspection two years ago at telecommunications provider for South America, the 23kV main switchgear cabinet for facility was inspected with infrared and ultrasound. Infrared results showed a small hot spot on one of the ceramic support bushings for the B-phase bus. Ultrasound found advanced stages of corona at the same location. Comments: A visual sign of the corona was white residue power at the same location of the hot spot. Communication with Dan Ninedorf of Ox Creek Energy Associates Inc. about this unusual hot spot revealed that arcing conditions can be supported within the white power dust of corona. Avoided Cost: Prevented the potential catastrophic loss of the main switchgear responsible for the facilities operations. Page 9

Acknowledgements The author would like to thank the following people instrumental in compiling this paper. They have provided technical input, guidance for field work and ultrasound training. James Hall Ultra-sound Technologies Atlanta, GA Area (770) 517-8747 jim.hall@ultra-soundtech.com www.ultra-soundtech.com Dan Ninedorf - Ox Creek Energy Associates Inc. Montello, WI 1-800-531-6232 cameras@maqs.net www.corona-technology-course.com Technical References Lautenschlager, M., PE., 1998, Corona Is there anything good about it?, NETA World, Fall 1998. www.hvcorp.com Page 10

Priority 1 Case Study-1 Take Out Of Service LOCATION: Substation-5 EQUIPMENT I.D. Breaker Cabinet 13-05-06 SPECIFIC ITEM: B- phase stationary contacts DATE: 12/2/05 TIME: 8:50 A.M. DESCRIPTION OF PROBLEM: Tracking detected on contacts recent failure No load on equipment during survey carbon present from Back side of cabinet showing stationary contacts Front side of cabinet with carbon residue and electrical flash-over on breaker

Priority 1 Case Study-2 Take Out Of Service DATE: 5/27/05 TIME: 11:35 A.M. LOCATION: Substation 17 EQUIPMENT I.D. Substation 17- Feed to ATF XFMR SPECIFIC ITEM: 13kV Load Interrupter Switch DESCRIPTION OF PROBLEM: Tracking conditions detected - No load on equipment during survey 13kV Load Interrupter Cabinet / Carbon tracks on B-phase insulation Carbon tracks on insulation between B- & C-phase fuses

Priority 2 Case Study-3 LOCATION: Substation 14 CORRECT ASAP EQUIPMENT I.D. 13kV / 480V Transformer SPECIFIC ITEM: INCOMMING POWER FEED Cables DATE: 5/26/05 TIME: 10:49 A.M. DESCRIPTION OF PROBLEM: Ultrasound detected presence of corona on feed lines. Non-shielded cable in contact with ground IR image shows no thermal anomaly - Dust / residue on cables from breakdown of insulation

Priority 2 Case Study-4 CORRECT ASAP LOCATION: Outside Substation Area EQUIPMENT I.D. Substation TB - Load Interrupter Cabinet SPECIFIC ITEM: Ceramic Stand-off bushing DATE: 1/10/05 TIME: 10:50 A.M. DESCRIPTION OF PROBLEM: Sustained arcing within corona powder on bushing. 23kV 95.8 F 95 SP01: 79.4 F AR01: 99.6 F 90 85 80 75.2 F Delta T of 20 F degree on bushing hot spot Conductive corona powder / dust on bushing supporting arcing conditions